首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
A simple and feasible potentiometric immunosensing platform based on enzymatic biocatalytic precipitation technique was designed for the sensitive detection of thyroid-stimulating hormone(TSH;a typical kind of biomarkers for thyroid carcinoma),using horseradish peroxidase(HRP)-loaded liposome for the signal amplification.To construct such an assay system,a sandwich-type immunoreaction was readily carried out on monoclonal anti-TSH capture antibody-coated electrode by using polyclonal antiTSH secondary antibody-conjugated HRP-loaded liposome.Accompanying the formation of sandwichtype immunocomplex,the carried liposome was lysed through the added Triton X-100 to release the entrapped HRP molecules,which catalyzed the oxidation of 4-chloro-1-naphthol to produce an insoluble and uncharged organic precipitation on the electrode surface,thereby causing the change of the local electrical potential.Two labeling protocols with and without the liposome were investigated for detection of target TSH,improved analytical features were achieved with HRP-entrapped liposome.Under optimal conditions,the potentiometric immunosensor had good responses for TSH detection within the linear range of 0.01-30 p IU/mL at a detection limit of 0.0067 p IU/mL.Good reproducibility,high specificity and long-time stability were acquired during the assay procedure.Importantly,a wellmatched accuracy between the potentiometric immunosensor and commercial human TSH ELISA kit was gave for the analysis of human serum samples.  相似文献   

2.
In this paper, we reported a sensitive electrochemical immunosensor coupling protein A/G@magnetic beads and an ALP-based enzymatic-electrochemical reaction on the inkjet printing microchips for the determination of thyroid stimulating hormone.  相似文献   

3.
Lin Z  Wang X  Li ZJ  Ren SQ  Chen GN  Ying XT  Lin JM 《Talanta》2008,75(4):965-972
A highly sensitive "two-site" chemiluminescent immunoassay specific for human thyroid stimulating hormone (TSH) was developed. The signal amplification was achieved via a biotin-streptavidin system (BSAS). The HRP-luminol-H(2)O(2) chemiluminescent system with high sensitivity was chosen as the detection system. Biotinylated anti-TSH monoclonal antibody (MAb) and HRP-labeled streptavidin were first synthesized. Then the signal amplification was achieved through the interaction between the biotinylated anti-TSH MAb and the HRP-streptavidin conjugate. The light intensity developed was in proportion to the TSH present in the samples. The assay showed little cross-reactivity with three other glycoprotein hormones (human chorionic gonadotropin (HCG), luteinizing hormone (LH), follicle stimulating hormone (FSH)) due to the high specificity of the antibody. The working range for human thyroid stimulating hormone was 0.1-40 mU L(-1). Both the intra-assay and inter-assay coefficients of variation were less than 10% for the BSAS based chemiluminescent enzyme immunoassay (CLEIA). The proposed assay had a sensitivity of 0.01 mU L(-1) which was 10-fold higher than the HRP-MAb conjugate based TSH immunoassay. Thus the higher sensitivity facilitated the clinical testing for thyroid states. The effects of several reaction parameters, such as incubation time, temperature, and reaction volume of the method, were also studied. This method has been successfully applied to the evaluation of TSH in human serum. Compared with the commercial enzyme chemiluminescent immunoassay, the correlation was satisfied.  相似文献   

4.
Chai R  Yuan R  Chai Y  Ou C  Cao S  Li X 《Talanta》2008,74(5):1330-1336
Nano-Au and methylene blue (MB) were assembled layer-by-layer (LBL) into films on the glassy carbon electrode modified by thiourea for detection of human chorionic gonadotrophin (HCG). The electrode modification process was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron micrograph (SEM). The factors influencing the performance of the amperometric immunosensor were studied in detail. Tests performed with this immunosensor showed good linearity, the working range for the system was 1.0–100.0 mIU/mL with a detection limit of 0.3 mIU/mL at 3σ. Moreover, the studied immunosensor exhibited high sensitivity and long-term stability. The present work supplied a promising test method for clinical immunoassay.  相似文献   

5.
Kong FY  Xu MT  Xu JJ  Chen HY 《Talanta》2011,85(5):2620-2625
In this paper, gold nanoparticle-thionine-reduced graphene oxide (GNP-THi-GR) nanocomposites were prepared to design a label-free immunosensor for the sensitive detection of carcinoembryonic antigen (CEA). The nanocomposites with good biocompatibility, excellent redox electrochemical activity and large surface area were coated onto the glassy carbon electrode (GCE) surface and then CEA antibody (anti-CEA) was immobilized on the electrode to construct the immunosensor. The morphologies and electrochemistry of the formed nanocomposites were investigated by using scanning electron microscopy (SEM), ultraviolet-visible (UV-vis) spectrometry, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). CV and differential pulse voltammetry (DPV) studies demonstrated that the formation of antibody-antigen complexes decreased the peak current of THi in the GNP-THi-GR nanocomposites. The decreased currents were proportional to the CEA concentration in the range of 10-500 pg/mL with a detection limit of 4 pg/mL. The proposed method was simple, fast and inexpensive for the determination of CEA at very low levels.  相似文献   

6.
A novel electrochemical immunosensor was developed for the determination of the hormone prolactin. The design involved the use of screen-printed carbon electrodes and streptavidin-functionalized magnetic particles. Biotinylated anti-prolactin antibodies were immobilized onto the functionalized magnetic particles and a sandwich-type immunoassay involving prolactin and anti-prolactin antibody labelled with alkaline phosphatase was employed. The resulting bio-conjugate was trapped on the surface of the screen-printed electrode with a small magnet and prolactin quantification was accomplished by differential pulse voltammetry of 1-naphtol formed in the enzyme reaction using 1-naphtyl phosphate as alkaline phosphatase substrate. All variables involved in the preparation of the immunosensor and in the electrochemical detection step were optimized. The calibration plot for prolactin exhibited a linear range between 10 and 2000 ng mL(-1) with a slope value of 7.0 nA mL ng(-1). The limit of detection was 3.74 ng mL(-1). Furthermore, the modified magnetic beads-antiprolactin conjugates showed an excellent stability. The immunosensor exhibited also a high selectivity with respect to other hormones. The analytical usefulness of the immnunosensor was demonstrated by analyzing human sera spiked with prolactin at three different concentration levels.  相似文献   

7.
Epidemiological studies have demonstrated an association between the risk of cardiovascular events and increasing C-reactive protein (CRP) concentration. This paper reports the development of an immunosensor for the assessment of the cardiovascular process using anti-C-reactive protein antibody immobilized onto a gold-printed screen electrode. Positive and negative human sera were successfully evaluated using electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV), and atomic force microscopy (AFM). EIS results show that, after the incubation with positive serum for myocardial infarction, the resistance increased about two times in relation to the negative serum. A linear range from 6.25 to 50 μg mL?1 and detection limit of 0.78 μg mL?1 using DPV were obtained. The immunosensor developed for the CRP detection using gold electrode revealed efficacy and a potential use for the diagnosis and monitoring of the progression of cardiovascular diseases.  相似文献   

8.
A new strategy is described to construct disposable electrochemical immunosensors for the assay of human immunoglobulin. It is based on a carbon paste electrode constructed from chitosan nanoparticles modified with colloidal gold. The stepwise assembly process of the immunosensor was characterized by means of cyclic voltammetry and electrochemical impedance spectroscopy. Assay conditions that were optimized included the amount of chitosan nanoparticles in the preparation of carbon paste electrode, antibody concentration, and the incubation time of the antibody immobilization. Using hexacyanoferrate as a mediator, the current change increased with the concentration of human immunoglobulin G. A linear relationship in the concentration range 0.3 to 120 ng mL?1 was achieved, with a detection limit of 0.1 ng mL?1 (S/N?=?3). The method combines the specificity of the immunological reaction with the sensitivity of the gold colloid amplified electrochemical detection, and it has potential application in clinical immunoassay.  相似文献   

9.
利用石墨烯纳米片层(GS)偶联牛血清白蛋白(BSA)标记的微囊藻毒素(MCLR)(BSA-MCLR)构建了纳米金(Au NPs)为信号探针的电流型免疫传感器。分别用扫描电子显微镜(SEM)、透射电子显微镜(TEM)和紫外-可见吸收光谱对合成纳米材料进行表征;用循环伏安法研究修饰电极表面的电化学特性。通过待测MCLR与固定的BSA-MCLR竞争结合抗体(anti-MCLR),之后恒电位将Au NPs氧化为Au Cl-4,再利用差分脉冲伏安法(DPV)进行阴极电位扫描,还原Au Cl-4为Au,以产生的峰电流值为检测信号,测定MCLR浓度。最佳实验条件下,用免疫传感器测定MCLR的线性范围为0.1~50μg/L,检出限为0.05μg/L。对传感器的重现性、稳定性和选择性进行了考察。相较于酶标探针,以Au NPs为信号探针标记抗体,可使检测过程更经济便捷,稳定性更强,检测效果良好。  相似文献   

10.
A novel potentiometric immunosensor for detection of hepatitis B surface antigen (HBsAg) has been developed by means of self-assembly (SA) and opposite-charged adsorption (OCA) techniques to immobilize hepatitis B surface antibody (HBsAb) on a platinum electrode. A cleaned platinum electrode was first pretreated in the presence of 10% HNO3 and 2.5% K2CrO4 solution and held at -1.5 V (vs SCE) for 1 min to make it negatively charged and then immersed in a mixing solution containing hepatitis B surface antibody, colloidal gold (Au), and polyvinyl butyral (PVB). Finally, HBsAb was successfully immobilized onto the surface of the negatively charged platinum electrode modified nanosized gold and PVB sol-gel matrixes. The modified procedure was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The immobilized hepatitis B surface antibody exhibited direct electrochemical behavior toward hepatitis B surface antigen (HBsAg). The performance and factors influencing the performance of the resulting immunosensor were studied in detail. More than 95.7% of the results of the human serum samples obtained by this method were in agreement with those obtained by enzyme-linked immunosorbent assays (ELISAs). The resulting immunosensor exhibited fast potentiometric response (<3 min) to HBsAg. The detection limit of the immunosensor was 2.3 ng.mL(-1), and the linear range was from 8 to 1280 ng.mL(-1). Moreover, the studied immunosensor exhibited high sensitivity, good reproducibility, and long-term stability (>6 months).  相似文献   

11.
A novel amperometric immunosensor based on L ‐cysteine/nanosized Prussian blue bilayer films ({NPB/L ‐cys}2) and gold nanoparticles (nano‐Au) was fabricated for determination of human chorionic gonadotrophin (HCG). First, L ‐cys and NPB was self‐assembled by layer‐by‐layer (LBL) technology to form {NPB/L ‐cys}2 bilayer films on the gold electrode. Subsequently, nano‐Au layer was immobilized on the {NPB/L ‐cys}2 bilayer films by electrodepositing gold chloride tetrahydrate and then anti‐HCG was assembly on the nano‐Au layer. Finally hemoglobin (Hb) was employed to block sites against nonspecific binding. With the electrocatalytic ability of Hb and NPB for the reduction of H2O2, the current signal of the antigen‐antibody reaction was amplified and the enhanced sensitivity was achieved. In this study, the assembly process and performance of the immunosensor were characterized by cyclic voltammetry (CV) and the morphology was researched by scanning electron microscopy (SEM). The immunosensor performed a high sensitivity and a wide linear response to HCG in two ranges from 0.5 to 10 mIU/mL and from 10 to 200 mIU/mL with a relatively low detection limit of 0.2 mIU/mL at 3 times the background noise, as well as good stability and long‐term life.  相似文献   

12.
A novel and highly sensitive electrochemical immunosensor was developed for the detection of protein biomarker tumor necrosis factor‐alpha (TNF‐α) based on immobilization of TNF‐α‐antibody (anti‐TNF‐α) onto robust nanocomposite containing gold nanoparticles (AuNP), multiwalled carbon nanotubes (MWCNTs) and ionic liquid (1‐buthyl‐3‐methylimidazolium bis (trifluoromethyl sulfonyl)imide). Functionalized MWCNT‐gold nanoparticle was produced by one‐step synthesis based on the direct redox reaction. The electrochemical properties of nanocomposite were characterized by electrochemical impedance spectroscopy and cyclic voltammetry. The anti‐TNF‐α was immobilized or entrapped in the nanocomposite and used in a sandwich type complex immunoassay with anti‐TNF‐α labeled with horseradish peroxidase as secondary antibody. Under optimum conditions, the immunosensor could detect TNF‐α in a linear range from 6.0 to 100 pg mL?1 with a low detection limit of 2.0 pg mL?1. The simple fabrication method, high sensitivity, good reproducibility, stability, as well as acceptable accuracy for TNF‐α detection in human serum samples are the main advantages of this immunosensor, which might have broad applications in protein diagnostics and bioassay.  相似文献   

13.
四乙氧基硅在HCl催化下水解形成硅溶胶。将硅溶胶与河虾抗体混合均匀后,涂于玻碳电极表面制备得非标记型河虾抗体免疫传感器。采用Fe(CN)63-/4-的磷酸盐缓冲溶液(pH 6.5)为测试底液,研究此传感器在免疫反应中的循环伏安和交流阻抗特性。结果显示免疫反应后传感器的循环伏安图上未出现新的氧化-还原峰,表明该免疫反应属于非氧化还原过程。采用交流阻抗监测电极表面,发现传感器阻抗值随虾过敏原浓度的增加而增大。对交流阻抗图进行分析,结果表明电极表面的免疫反应是一个受电子转移控制的过程。当虾过敏原浓度在0~10 ng/mL之间,电极表面电子转移阻抗的增加值与虾过敏原浓度呈线性关系,检出限为0.1 ng/mL(S/N=3)。该方法已成功应用于河虾制品中过敏原的测定。  相似文献   

14.
将抗体结合蛋白A和交联剂联硫基二(琥珀酰亚胺丙酸盐)(DTSP)组成的骨架修饰到电极表面,再将单克隆雌二醇抗体与骨架中的蛋白A相结合,制备出电化学免疫传感器.利用样品雌二醇与辣根过氧化酶所标记的雌二醇同传感器表面抗体的竞争性结合,将该传感器用于测定溶液中样品雌二醇的浓度;利用方波伏安法监测电化学还原辣根过氧化酶催化产生的苯醌分子的电流,以还原电流为纵坐标,以雌二醇浓度为横坐标绘制标准曲线.结果表明,雌二醇浓度在50~1 500ng.L-1范围内与方波伏安还原电流呈良好的线性关系,灵敏度为0.51μA.ng-1.L,检测限为50ng.L-1.所制备的免疫传感器良好的分析性能得益于蛋白A和DTSP所组成的骨架,该骨架能够增加免疫分子组分在电极表面的修饰量,并能够控制抗体在电极上的结合方位,使其抗原结合位点朝向电极外端,减少结合空间阻碍.  相似文献   

15.
《Electroanalysis》2005,17(2):155-161
A highly sensitive immunosensor based on immobilization of hepatitis B surface antibody (HBsAb) on platinum electrode (Pt) modified silver colloids and polyvinyl butyral (PVB) as matrixes has been developed for potentiometric immunoanalysis to detect hepatitis B surface antigen (HBsAg) in this study. HBsAb molecules were immobilized successfully on nanometer‐sized silver colloid particles associated with polyvinyl butyral on a platinum electrode surface. The modification procedure was electrochemically monitored by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The HBsAb‐silver‐PVB‐modified electrode exhibited direct electrochemical behavior toward HBsAg. The factors influencing the performance of the resulting immunosensor were studied in detail. More than 94.7% of the results of human serum samples obtained by this method were in agreement with those obtained by enzyme‐linked immunosorbent assays (ELISAs). The resulting immunosensor exhibited a sigmoid curve with log HBsAg concentration, high sensitivity (39.8 mV/decade), wide linear range from 16.0 to 800 ng mL?1 with a detection limit of 3.6 ng mL?1, fast potentiometric response (<3 min) and long‐term stability (>4 months). The response mechanism of the immunosensors was also studied with AC impedance techniques.  相似文献   

16.
《Electroanalysis》2018,30(1):31-37
The electrochemical detection of alpha‐feto protein based on novel gold nanoparticles‐ poly(propylene imine) dendrimer platform is reported. The platform was prepared by co‐electrodeposition of gold nanoparticles and generation 3 poly (propylene imine) dendrimer on a glassy carbon electrode. Each modifying step was characterised by cyclic voltammetry and electrochemical impedance spectroscopy. The electrochemical measurements showed that the platform was stable, conducting and exhibited reversible electrochemistry. Results obtained from the electrochemical impedance spectroscopy interrogation in [Fe(CN)63−/4−] redox probe showed a marked reduction in charge transfer resistance (Rct) after each modification step. The immunosensor was prepared by immobilisation of a probe anti‐alpha feto protein (AFP) on the platform for 3 hrs at 35 °C followed by blocking the surface with bovine serum albumin to minimise non‐specific binding. The prepared immunosensor was used to detect AFP over a wide concentration range from 0.005 to 500 ng/mL and detection limits of 0.0022 and 0.00185 ng/mL were obtained for SWV and EIS measurements respectively. The immunosensor gave good stability over a period of fourteen days when stored at 4 °C.  相似文献   

17.
采用溶剂热法, 通过有机单体合成了一种亚胺键连接的共价有机框架材料(COF-LZU1); 在常温常压条件下, 通过后合成的方法将贵金属钯(Ⅱ)引入到COF材料中, 合成了复合材料Pd/COF-LZU1, 该材料具有优良的催化性能. 利用Pd/COF-LZU1多孔复合材料将C-反应蛋白(CRP)抗体(anti-CRP)固定在玻碳电极表面, 构建了一种非标记型CRP免疫传感器. 当抗体与抗原发生免疫反应时, 形成的免疫复合物会阻碍电化学探针[Fe(CN)6]4-/3-的电子传递, 降低其响应电流, 从而实现CRP的快速检测. 采用交流阻抗和差示脉冲伏安法(DPV)考察了免疫传感器的电化学特性, 同时考察了测试底液的pH值、 抗原培育时间和抗体固定浓度等实验条件对传感器性能的影响. 在最优的实验条件下, 采用DPV法对CRP进行检测的线性范围为5~180 ng/mL, 检出限为1.66 ng/mL, 线性相关系数为0.992.  相似文献   

18.
《Electroanalysis》2018,30(2):353-360
A label‐free electrochemical immunosensor based on the liquid crystal (E)‐1‐decyl‐4‐[(4‐decyloxyphenyl)diazenyl]pyridinium bromide (Br−Py), together with heparin‐stabilized gold nanoparticles (AuNP‐Hep) and Nafion is proposed for the determination of prostate‐specific antigen (PSA). The Br−Py liquid crystal presented redox properties and good film‐forming abilities on the electrode surface, and thus it is a suitable alternative as a redox probe for a label‐free electrochemical immunosensor, which could simplify the analysis methodology. The stepwise construction of the immunosensor and the incubation process (immunocomplex formation) were characterized by voltammetry and electrochemical impedance spectroscopy. The proposed immunosensor could directly detect PSA concentrations in the incubation samples, based on the suppression of the Br−Py redox peak (‘base peak’) current. After optimization, the immunosensor exhibited a linear response to PSA concentrations in the range of 0.1 to 50 ng mL−1, with a calculated detection limit of 0.08 ng mL−1. The reproducibility (coefficient of variance less than 3.0 %), selectivity and accuracy of the methodology were adequate. The immunosensor was satisfactorily applied in the quantification of PSA in human blood plasma samples.  相似文献   

19.
In the present study, we developed a novel label‐free capacitance impedimetric immunosensor based on the immobilization of the human monoclonal antibody anti‐interleukin‐10 (anti‐IL‐10 mAb) onto polypyrrole (PPy)‐modified silicon nitride (Si3N4) substrates. The immunosensor was used for the detection of the recombinant interleukin‐10 antigen (rh IL‐10) that may be secreted in patients at the early stage of inflammation. The immunosensor was created by chemical deposition of PPy conducting layer on pyrrole?silane (SPy)‐treated Si/SiO2/Si3N4 substrates (Si/SiO2/Si3N4?SPy), followed by anti‐IL‐10 mAb immobilization through carboxyl‐functionalized diazonium (CMA) protocol and carbodiimide chemistry. The surface characterization and the biofunctionalization steps were characterized by SEM, FTIR and cyclic voltammetry (CV) while the detection process was carried out by using electrochemical impedance spectroscopy (EIS) analyses. The created immunosensor showed two linear fittings (R2=0.999) for the detection of rh IL‐10 within the concentration range from 1–50 pg/mL. It exhibited high sensitivity (0.1128 (pg/mL)?1) with a very low limit of detection (LOD)=0.347 pg/mL, more particularly, at the low concentration range (1–10 pg/mL). Thus, this developed polypyrrole‐based immunosensor represents a promising strategy for creation of miniaturized label‐free, fast and highly sensitive biosensors for diagnosis of inflammation biomarkers at very low concentrations with reduced cost.  相似文献   

20.
Accurate detection of cancer antigen 72-4 (CA72-4), a tumor-associated glycoprotein, is of great significance for gastric cancer diagnosis and immunotherapy monitoring. Modification of noble metal nanoparticles on transition metal dichalcogenides can significantly enhance functions, such as electron transport. Molybdenum disulfide gold nanoparticles nanocomposites (MoS2-Au NPs) were prepared in this study and a series of characterization studies were carried out. In addition, a label-free, highly sensitive electrochemical immunosensor molybdenum disulfide -Au nanoparticles/Glassy carbon electrode (MoS2-Au NPs/GCE) was also prepared and used for the detection of CA72-4. The electrochemical performance of the immunosensor was characterized by electrochemical techniques, such as cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The results indicated that better MoS2-Au NPs nanomaterials have been synthesized, and the prepared electrochemical immunosensor, MoS2-Au NPs/GCE, showed excellent electrochemical performance. The sensor exhibited high detection sensitivity under optimal conditions, including an incubation time of 30 min, an incubation temperature of 25 °C, and a pH of 7.0. The electrochemical immunosensor also had a low detection limit of 2.0 × 10?5 U/mL (S/N = 3) in a concentration range of 0.001–200 U/mL, with good selectivity, stability, and repeatability. In conclusion, this study provided a theoretical basis for the highly sensitive detection of tumor markers in clinical biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号