Cu2O/nitrogen-doped grapheme(NG) nanocomposite material was prepared via a facile one step chemical reduction and characterized by means of X-ray diffraction(XRD) and scanning electron microscopy(SEM). A new electrochemical sensor was then fabricated by coating Cu2O/nitrogen-doped graphene nanocomposite with Nafion on glassy carbon electrode(Cu2O/NG/Nafion/GCE). The electrochemical response of this modified electrode toward ofloxacin was examined by cyclic voltammetry. The results indicate that Cu2O/NG/Nafion composite-modified electrode exhibits higher catalytic activity in the electrochemical oxidation of ofloxacin compared with glassy carbon electrode(GCE), Cu2O/Nafion modified electrode(Cu2O/Nafion/GCE), and N-doped graphene/Nafion modified electrode(NG/Nafion/GCE). Under optimal conditions, the peak current was found to be linearly proportional to the concentration of ofloxacin in the 0.5-27.5 μmol/L and 27.5-280 μmol/L ranges with a lower detection limit of 0.34 μmol/L, higher sensitivity of 39.32 μA·L·mmol-1 and a shorter reaction time of less than 2 s. In addition, Nafion can enhance the stability of the modified electrode and prevent some negative species. Thus the modified electrode exhibits good selectivity and a long working life. The Cu2O/NG/Nafion composite modified electrode shows promising application in electrochemical sensors, biosensors, and other related fields because of its excellent properties.  相似文献   

2.
通过静电纺丝技术合成碳纳米纤维,以循环伏安法在此碳纤维上电聚合乙酸锌制备复合纳米材料作为一种新型的电化学增敏剂,用于修饰玻碳电极,开发了一种基于碳纤维和氧化锌复合材料的新型电化学传感器(ZnO/CNF/GCE)。使用循环伏安法、差分脉冲伏安法等进行电化学催化性能的研究,并优化实验条件。结果表明,与裸电极相比,在pH 5.5磷酸盐缓冲溶液中,ZnO/CNF/GCE修饰电极能使氧氟沙星的峰电流明显提升,线性范围1~200μmol/L,检测限为0.33μmol/L。该ZnO/CNF/GCE修饰电极已用于氧氟沙星滴耳液中氧氟沙星的含量测定。  相似文献   

3.
基于S-Cd和N-Cd的亲和作用,利用一锅法制备了MoS2-掺氮石墨烯(NG)新型纳米复合材料。采用方波溶出伏安法实现了Cd2+的灵敏测定。在最优实验条件下,Cd2+的溶出峰电流与Cd2+的浓度在0.01~20μmol/L范围内呈线性关系(R2=0.996),检出限为2.50 nmol/L。该传感器可用于监测实际样品中Cd2+。  相似文献   

4.
以苹果酸为碳源,磷酸铵提供氮源,采用固态热解法一步合成一种水溶性的、氮掺杂的蓝色荧光碳点(N-CDs)。 所得到的碳点荧光量子产率高达20.7%,形貌近似球形,平均粒径约为3.3 nm。 基于环丙沙星(CIP)对碳点的荧光增强作用,建立了一种CIP的定量检测方法。 最佳实验参数为:碳点浓度为7.5 μg/mL,pH值为5.9,孵化时间为5 min。 在此实验条件下,碳点的荧光强度增加值(ΔF)和CIP的浓度在0.39~40.00 μmol/L范围内呈良好的线性关系,方法的检出限为0.12 μmol/L,相对标准偏差(n=5)为4.2%。 干扰实验结果指出,除了铜离子具有明显的影响外,其它共存物质的干扰可以忽略不计,而铜离子的干扰可通过加入草酸铵来掩蔽。 最后利用所构建的荧光传感器对实际样品中CIP进行检测,回收率在93%~107%之间。 本研究为CIP定量分析提供了一种简单、快速、灵敏度高、选择性好而有效的测定方法。  相似文献   

5.
A simple and rapid electrochemical method is developed for the determination of trace-level norfloxacin, based on the excellent properties of multi-walled carbon nanotubes (MWCNTs). The MWCNTs/Nafion film-coated glassy carbon electrode (GCE) is constructed and the electrochemical behavior of norfloxacin at the electrode is investigated in detail. The results indicate that MWCNTs modified glassy carbon electrode exhibited efficiently electrocatalytic oxidation for norfloxacin (NFX) with relatively high sensitivity, stability and life time. Under conditions of cyclic voltammetry, the current for oxidation of selected analyte is enhanced significantly in comparison to the bare GCE. The electrocatalytic behavior is further exploited as a sensitive detection scheme for the analyte determinations by linear sweep voltammetry (LSV). Under optimized condition in voltammetric method the concentration calibration range and detection limit (S/N=3) are 0.1-100 micromol/L and 5 x 10(-8)mol/L for NFX. The proposed method was successfully applied to NFX determination in tablets. The analytical performance of this sensor has been evaluated for detection of the analyte in urine as a real sample.  相似文献   

6.
Phenylethanolamine A (PEA), a β‐agonist, was found to be illegally used as a growth promoter in pigs last year, causing Chinese government's great attention. Here, a sensitive electrochemical method was developed for detecting PEA by immobilization of gold nanoparticles (AuNPs), multiwalled carbon nanotubes (MWCNTs) and Nafion on the surface of a glassy carbon electrode (GCE). The Nafion/MWCNTs/AuNPs film was characterized by scanning electronic micrographs (SEM) and electrochemical impedance spectroscopy (EIS). The electrochemical behaviors of PEA at the modified GCE were investigated in detail. The synergetic effects of AuNPs, MWCNTs and Nafion amplify the electrochemical reduction signal of PEA, and result in high sensitivity for PEA determination. Under the optimal conditions, the electrochemical sensor shows a wide linear range of 0.01 to 10 (mol/L with a detection limit of 0.005 µmol/L. Moreover, the fabricated sensor presents high selectivity and long‐term stability, which paves a new way for simple, rapid, sensitive detection of PEA.  相似文献   

7.
Wang F  Zhou J  Liu Y  Wu S  Song G  Ye B 《The Analyst》2011,136(19):3943-3949
An electrochemical sensor, based on a graphene oxide (GO)-Nafion composite film modified glassy carbon electrode (GCE), was developed and used for detection of trace amounts of colchicine. Owing to the large surface area, good conductivity of GO and good affinity of Nafion, the sensor exhibited excellent electrocatalytic activity for the oxidation of colchicine, displaying a wide linear response from 5.0 × 10(-8) to 2.0 × 10(-5) mol L(-1) and a low detection limit of 1.5 × 10(-8) mol L(-1) in 0.1 mol L(-1) H(2)SO(4) solution. And this modified electrode exhibited a superior immunity from epinephrine, dopamine and ascorbic acid interference. The method was also applied successfully to detect colchicine in medicinal tablets.  相似文献   

8.
A novel electrochemical sensor was fabricated by electrodeposition of gold nanoparticles on a poly(L-methionine) (PMT)-modified glassy carbon electrode (GCE) to form a nano-Au/PMT composite-modified GCE (nano-Au/PMT/GCE). Scanning electron microscopy and electrochemical techniques were used to characterize the composite electrode. The modified electrode exhibited considerable electrocatalytic activity towards the oxidation of dopamine (DA) and uric acid (UA) in phosphate buffer solution (pH = 7.00). Differential pulse voltammetry revealed that the electrocatalytic oxidation currents of DA and UA were linearly related to concentration over the range of 5.0×10-8 to 10-6 mol/L for DA and 7.0×10-8 to 10-6 mol/L for UA. The detection limits were 3.7×10-8 mol/L for DA and 4.5×10-8 mol/L for UA at a signal-to-noise ratio of 3. According to our experimental results, nano-Au/PMT/GCE can be used as a sensitive and selective sensor for simultaneous determination of DA and UA.  相似文献   

9.
运用循环伏安法与线性扫描伏安法研究了阿奇霉素在多壁碳纳米管修饰玻碳电极上的电化学行为,建立了一种直接测定阿奇霉素的电化学分析方法。结果表明,与裸玻碳电极相比,多壁碳纳米管修饰电极能显著提高阿奇霉素的氧化峰电流,阿奇霉素的电极过程完全不可逆,存在典型的吸附特性。在优化的实验条件下,氧化峰电流与阿奇霉素浓度在3.0×10-7~2.5×10-5 mol/L和2.5×10-5~5.0×10-4 mol/L范围内呈现良好的线性关系,检出限为1.0×10-7 mol/L。  相似文献   

10.
An electrochemical sensor for doxycycline hyclate(DC)detection with high sensitivity and good selectivity is reported.The sensor was fabricated by electro-polymerization of molecularly imprinted polymers(MIPs)in the presence of DC onto multi-walled carbon nanotubes modified glassy carbon electrode(MWCNTs/GCE).The MWCNTs can significantly increase the current response of the sensor,leading to enhanced sensitivity.The MIPs provide selective recognition sites for DC detection.The experimental parameters,such as the polymer monomer concentration,supporting electrolyte pH,the time for electro-polymerization and the incubation time of the sensor with DC were optimized.Under optimized experimental conditions,the sensor displayed a linear range of 0.05μmol/L-0.5μmol/L towards DC detection,with the detection limit of 1.3×10^-2μmol/L.The sensor was successfully applied for recovery test of DC in human serum samples.  相似文献   

11.
An electrochemical sensor based on self-made nano-porous pseudo carbon paste electrode (nano-PPCPE) has been successfully developed, and used to detect Cd2+ and Pb2+. The results showed that the electrodes can quantitatively detect trace Cd2+ and Pb2+, and with satisfied limit of detection, which has great significance in electrochemical analysis and detection.  相似文献   

12.
A multi-wall carbon nanotubes (MWNTs)-Nafion film-coated glassy carbon electrode (GCE) was fabricated and the electrochemical behavior of ofloxacin on the MWNTs-Nafion film-coated GCE were investigated by cyclic voltammetry (CV), linear sweep voltammetry (LSV) and electrochemical impedance spectroscopy (EIS). The oxidation peak current of ofloxacin increased significantly on the MWNTs-Nafion film modified GCE compared with that using a bare GCE. This nano-structured film electrode exhibited excellent enhancement effects on the electrochemical oxidation of ofloxacin. A well-defined oxidation peak attributed to ofloxacin was observed at 0.97 V and was applied to the determination of ofloxacin. The oxidation peak current was proportional to ofloxacin concentration in the ranges 1.0 × 10−8 to 1.0 × 10−6 mol/L and 1.0 × 10−6 to 2.0 × 10−5 mol/L. A detection limit of 8.0 × 10−9 mol/L was obtained for 400 s accumulation at open circuit (S/N = 3). This method for the detection of ofloxacin in human urine was satisfactory. __________ Translated from Chinese Journal of Applied Chemistry, 2007, 24(5): 540–545 [译自: 应用化学]  相似文献   

13.
Journal of Solid State Electrochemistry - A novel electrochemical sensor for paraquat (PQ) detection based on molecularly imprinted polymer (MIP) membranes on a glassy carbon electrode (GCE)...  相似文献   

14.
Carbon dots(CDs) with multi-color emissive properties and a high photoluminescent quantum yield(PLQY) have attracted great attention recently due to their potential applications in chemical,environmental,biological and photo-electronic fields.Solvent-dependent effect in photoluminescence provides a facial and effective approach to tune the emission of CDs.In this study,green emissive nitrogen-doped carbon dots(N-CDs) are synthesized from p-hydroquinone and ethylenediamine through a simple hydrothermal method.The as-prepared N-CDs possess a robust excitation-independent green luminescence and a high PLQY of up to 15.9%.Further spectroscopic characterization indicates that the high PLQY is achieved by the balance of nitrogen doping states and the surface passivation extent in CDs.The N-CDs also exhibit solvent-dependent multi-color emissive property and distinct PLQY in different solvents(the maximum can reach up to 25.3%).Furthermore,the as-prepared N-CDs are applied as fluorescence probes to detect acetone and H2O2 in water.This method has exhibited a low detection limit of acetone(less than 0.1 %) and a quick and linear response to the H_2O_2 with the concentration from 0 to 120 μmol/L.This work broadens the knowledge of applying CDs as probes in the bio and chemical sensing fields.  相似文献   

15.
 A promising electrochemical sensor was fabricated by electrodeposition of Pd nanoparticles (PdNPs) on poly(thiophene-3-acetic acid) (PTAA)-modified glassy carbon electrode (GCE), forming a PdNPs/PTAA composites-modified GCE (PdNPs/PTAA/GCE). Scanning electron microscope (SEM) and electrochemical techniques were used for the characterization of these composites. It was found that the PdNPs/PTAA layer was very uniform. Electrochemical experiments showed that this proposed PdNPs/PTAA composites-modified electrode exhibited excellent electrocatalytic activity towards the oxidation of hydrazine. Under the optimum conditions, the proposed sensor can be applied to the quantification of hydrazine with a wide linear range from 8.0?10-9 mol/L to 1.0?10-5 mol/L with a low detection limit of 2.67?10-9 mol/L. The experiment results also showed that the sensor exhibited good reproducibility and long-term stability, as well as high selectivity with no interference from other potential competing species.  相似文献   

16.
历洋  李锦州  庞筱喆 《应用化学》2013,30(5):578-583
制备了一种新型电化学传感器--聚2,2-联吡啶(Pbpy)/1-苯基-3-甲基-4-(α-呋喃甲酰基)-5-吡唑啉酮(HPM-α-FP)/玻碳(GC)复合膜修饰电极。 运用循环伏安法和脉冲伏安法研究了药物分子黄嘌呤(XN)的电化学行为及反应机理。 与裸GCE和Pbpy/GCE电极相比,复合修饰电极Pbpy/HPM-α-FP/GCE测定XN的氧化峰电流和检测灵敏度均有显著提高,表明聚2,2-联吡啶与酰基吡唑啉酮产生了协同增效作用。 当pH=8,扫速为100 mV/s的条件下,氧化峰电流与黄嘌呤浓度在6×10-7~1×10-5 mol/L和1×10-5~1×10-4 mol/L之间均呈现良好的线性关系,检出限为1×10-8 mol/L。 该修饰电极可用于共存尿酸(UA)、抗坏血酸(AA)体系及实际样品的黄嘌呤含量测定。  相似文献   

17.
基于羧基化多壁碳纳米管修饰的玻碳电极(CMWCNTs/GCE),构建了一种灵敏检测氨基脲(SEM)的电化学传感器.采用傅里叶变换红外光谱、透射电子显微镜、电化学阻抗谱对修饰材料进行表征.结果表明,羧基化的多壁碳纳米管出现羧基碳氧双键的红外特征峰,管径明显减小,长度变短,电化学阻抗值显著减小.在1 mol/L HAc-NaAc缓冲液中,利用循环伏安法和时间-电流曲线研究了SEM在CMWCNTs修饰电极上的电化学行为.SEM在修饰电极上呈现不可逆的氧化峰.与裸电极相比,氧化峰电流明显增大.在最佳实验条件(pH 7.0,扫描速度为0.1 V/s)下,测得SEM在5.00×10-6~1.09×10-3mol/L浓度范围内与氧化峰电流呈线性关系,线性方程为IP(μA)=-0.472+0.0599C(μmol/L),相关系数r=0.997,检出限为1.88×10-7 mol/L(S/N=3).在实际猪肝样品检测中加标回收率为92.8%~98.0%.  相似文献   

18.
In this paper, a novel and convenient electrochemical sensor for detection of methimazole (MMI) by differential pulse voltammetry is presented. This sensor was fabricated by dripping well-dispersed MWCNTs onto glassy carbon electrode (GCE) surface, and then poly-l-Arg (P-L-Arg) film was deposited on the electrode. Finally, Cu nanoparticles (CuNPs) were electrochemically deposited on the resulting film by using cyclic voltammetry to prepare CuNPs-P-L-Arg/MWCNTs/GCE. The surface morphology of the electrodes has been studied by scanning electron microscopy. Studies reveal that the irreversible oxidation of MMI was highly facile on CuNPs-P-L-Arg/MWCNTs/GCE. The dynamic detection range of this sensor to MMI was 5.2–50 µM, with the detection limit of 2 µM. A new voltammetric method for determination of MMI was erected and shows good sensitivity and selectivity, very easy surface update and good stability. The analytical application of the modified electrode is demonstrated by determining MMI in biological fluids (serum).  相似文献   

19.
《中国化学快报》2023,34(1):107299
Boron/nitrogen-co-doped carbon (BCN) nanosheets decorated with Fe2O3 nanocrystals (Fe2O3–BCN) were cast on a glassy carbon electrode (GCE) and applied as an electrochemical sensor to effectively detect paraquat (PQ), a toxic herbicide, in aqueous environments. A linear experiment performed using square wave voltammetry (SWV) under optimized experimental conditions produced a decent linear relationship and a low detection limit (LOD) of 2.74 nmol/L (S/N = 3). Repeatability, reproducibility, stability, and interference experiments confirmed that the Fe2O3–BCN/GCE system exhibited decent electrochemical sensing performance for PQ molecules. Notably, the designed sensor showed high selectivity and a decent linear relationship with PQ concentration in natural water samples. To the best of our knowledge, this is the first study on the preparation of Fe2O3–BCN nanosheets for PQ detection. The proposed sensor can be employed as an effective alternative tool for distinguishing and processing PQ.  相似文献   

20.
《中国化学快报》2019,30(12):2211-2215
An electrochemical sensor based on self-made nano-porous pseudo carbon paste electrode (nano-PPCPE) has been successfully developed, and used to detect Cd2+ and Pb2+. The experimental results showed that the electrochemical performance of nanoPPCPE is evidently better than both glassy carbon electrode (GCE) and pure carbon paste electrode (CPE). Then the prepared nano-PPCPE was applied to detect Cd2+ and Pb2+ in standard solution, the results showed that the electrodes can quantitatively detect trace Cd2+ and Pb2+, which has great significance in electrochemical analysis and detection. The linear ranges between the target ions concentration and the DPASV current were from 0.1–3.0 μmol/L, 0.05–4.0 μmol/L for Cd2+ and Pb2+, respectively. And the detection limits were 0.0780 μmol/L and 0.0292 μmol/L, respectively. Moreover, the preparation of the nano-PPCPE is cheap, simple and has important practical value.  相似文献   