首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An array of thermo-actuated poly(N-isopropylacrylamide) (PNIPAAm) multivalves was designed and fabricated to perform volume-based sample injection for microflow injection analysis on a glass microfluidic chip. The PNIPAAm monolithic plug valves were prepared inside the vinylized glass channels by photopolymerization in water-ethanol (1:1) medium using 2-hydroxy-2-methyl propiophenone (Darocure-1173) as the initiator and a photo-mask for micropattern transferring. Experimental conditions for the photopolymerization were studied, and the thermo-responsive behavior of the synthesized monolithic plug valves was investigated. To perform active heating and cooling of the on-chip integrated thermo-actuated valves, micro-Peltier devices were used and operation times of 3-s for opening and 7-s for closing were obtained. In the close status, a 2-mm long monolithic plug valve could endure a pressure of no higher than 0.45 MPa. The volume-based sample and reagent injector was composed of two groups of valves (total valve number of 5) and two loops. When the two groups of valves were alternatively opened and closed via thermo-actuation, the sampling loops were able to be switched between loading and injection position without any mechanical moving parts. Cooperating with syringe pumps, the microfluidic chip with the integrated sample injector has been demonstrated for microflow injection chemiluminescence detection of hydrogen peroxide. For a sampling volume of 6 nL, linear response was observed over the H2O2 concentration range of 0-2 mmol L−1, and a precision of 0.6% (RSD, n = 11) was achieved for a standard H2O2 solution 2 mmol L−1.  相似文献   

2.
PDMS-based multichannel microfluidic chip was designed and fabricated in a simple approach using readily available tools. UV-initiated in situ polymerization of poly(2-hydroxy ethyl methacrylate-co-di(ethylene glycol) diacrylate-co-N,Nʹ-diallyl l -tartardiamide) in an Eppendorf tube was achieved within 40 min. This polymerization process was successfully translated to a microfluidic chip format without any further modifications. Iminodiacetic acid was successfully immobilized on aldehyde functional monoliths via Schiff base reaction and confirmed by FT-IR spectroscopy. Four transition metal ions (Co (II), Zn (II), Ni (II), and Cu (II)) were chelated individually on four IDA-monolith microfluidic chips. The conjoint metal-ion monolith microfluidic chip has displayed high permeability (9.40 × 10–13 m2) and a porosity of 32.8%. This affinity microfluidic chip has pre-fractioned four human plasma proteins (fibrinogen, immunoglobulin, transferrin, and human serum albumin) based on their surface-exposed histidine surface topography. A protein recovery of approximately 95% (Bradford assay data) was achieved. The multimonolith microchip can be reusable even after three protein adsorption-desorption cycles.  相似文献   

3.
A simple microfluidic valve, without any moving parts, is presented that can control solution flow on demand in microchannels of many different materials using a low‐power electric signal. Many independently operating valves can easily be integrated into complex microfluidic systems. The valve consists of a self‐assembled monolayer (SAM) formed on a platinum electrode that is incorporated directly in the microchannel. The normally‐on valve stops the solution flow due to a hydrophobic SAM on the electrode surface. The solution is allowed to pass the valve by applying a potential to the electrode, which removes the SAM due to reductive desorption. The valve operation is highly stable and has switching times of the order of 1 s. The valve is ideal for controlled solution manipulation in integrated micro‐analytical systems and autonomous microfluidic systems.  相似文献   

4.
微流控芯片实验室   总被引:3,自引:0,他引:3  
林炳承  秦建华 《色谱》2005,23(5):456-463
以作者所在课题组近年来的研究工作为基础,就芯片实验室平台建设及相应的以系统生物学为最终目标的功能化研究作一说明,对在分子和细胞层面,甚至是单分子、单细胞水平上实现以规模集成为特征的临床诊断和药物筛选的努力予以特别的关注。  相似文献   

5.
Zhang-Run Xu  Cui-Hong Liu  Jin Fang 《Talanta》2010,80(3):1088-1093
A novel microfluidic chip integrating an osmosis-based micro-pump was developed and used for perfusion cell culture. The micro-pump includes two sealed chambers, i.e., the inner osmotic reagent chamber and the outer water chamber, sandwiching a semi-permeable membrane. The water in the outer chamber was forced to flow through the membrane into the inner chamber via osmosis, facilitating continuous flow of fluidic zone in the channel. An average flow rate of 0.33 μL min−1 was obtained within 50 h along with a precision of 4.3% RSD (n = 51) by using a 100 mg mL−1 polyvinylpyrrolidone (PVP) solution as the osmotic driving reagent and a flow passage area of 0.98 cm2 of the semi-permeable membrane. The power-free micro-pump has been demonstrated to be pulse-free offering stable flow rates during long-term operation. The present microfluidic chip has been successfully applied for the perfusion culture of human colorectal carcinoma cell by continuously refreshing the culture medium with the osmotic micro-pump. In addition, in situ cell immunostaining was also performed on the microchip by driving all the reagent zones with the integrated micro-pump.  相似文献   

6.
We have developed a new microfluidic chip capable of accurate metering, pneumatic sample injection, and subsequent electrophoretic separation. The pneumatic injection scheme, enabling us to introduce a solution without sampling bias unlike electrokinetic injection, is based upon the hydrophobicity and wettability of channel surfaces. An accurately metered solution of 10 nL could be injected by pneumatic pressure into a hydrophilic separation channel through Y-shaped hydrophobic valves, which consist of polydimethylsiloxane (PDMS) and fluorocarbon (FC) film layers. We demonstrated the successful pneumatic injection of a red ink solution into the separation channel as a proof of the concept. A mixture of fluorescein and dichlorofluorescein (DCF) could be baseline-separated using a single power source in microchip electrophoresis.  相似文献   

7.
Isoelectric focusing (IEF), traditionally accomplished in slab or tube gels, has also been performed extensively in capillary and, more recently, in microchip formats. IEF separations performed in microchips typically use electroosmotic flow (EOF) or chemical treatment to mobilize the focused zones past the detection point. This report describes the development and optimization of a microchip IEF method in a hybrid PDMS-glass device capable of controlling the mobilization of the focused zones past the detector using on-chip diaphragm pumping. The microchip design consisted of a glass fluid layer (separation channels), a PDMS layer and a glass valve layer (pressure connections and valve seats). Pressure mobilization was achieved on-chip using a diaphragm pump consisting of a series of reversible elastomeric valves, where a central diaphragm valve determined the volume of solution displaced while the gate valves on either side imparted directionality. The pumping rate could be adjusted to control the mobilization flow rate by varying the actuation times and pressure applied to the PDMS to actuate the valves. In order to compare the separation obtained using the chip with that obtained in a capillary, a serpentine channel design was used to match the separation length of the capillary, thereby evaluating the effect of diaphragm pumping itself on the overall separation quality. The optimized mIEF method was applied to the separation of labeled amino acids.  相似文献   

8.
We developed a novel microbioassay system equipped with a gradient mixer of two solutions, and we applied the microfluidic system to an anti-cancer agent test using living animal cells on a microchip. A microchannel for the gradient mixing of two solutions and eight other microchannels for cell assay were fabricated on a poly(dimethylsiloxane) substrate using a soft-lithography method. The functions necessary for this bioassay, i.e., cell culturing, chemical stimulation, cell staining, and fluorescence determination, were integrated into the microfluidic chip. Eight gradient concentrations of the fluorescein solution, ranging from 1 to 98 microg/ml, were archived at 0.1 microl/min on a microchip. A stomach cancer cell line was cultured, and a cell viability assay was conducted using 5-Fluorouracil as an anti-cancer agent on the microchip. Cell viability changed according to the estimated concentration of the agent solution. With the microbioassay system, an anti-cancer agent test was conducted using living cells simultaneously in eight individual channels with the gradient concentration of the agent on a microchip.  相似文献   

9.
A novel microfluidic DNA extraction protocol based on integrated diaphragm microvalves/pumps and silica-deposited open-channel columns was developed specifically for automated and parallel DNA solid-phase extraction (SPE). The method uses microfluidic chips with a sandwiched structure containing three layers, which are the upper fluidic layer with surface-deposited silica on glass open channels as the extraction phase, the lower actuation layer with valve actuation channels on a glass wafer, and the middle poly(dimethylsiloxane) (PDMS) membrane for reversible bonding of the two glass substrates. These two glass substrates can be reused after thoroughly cleaning and the PDMS membrane can be replaced conveniently, which could effectively decrease the time and cost of chip manufacturing. The normally closed microvalves/pumps were used to automatically control all processes of the on-chip DNA SPE without cross-contamination and leakage, enabling the processing of multiple samples in parallel without changing the microvalve control module. Using the microchip device with integrated microvalves/pumps, automated, programmable, and simultaneous λ-DNA extractions from different samples could be attained, even from complex solutions such as human blood, and the silica-deposited open-channel columns could be reused stably and reliably. Results have demonstrated that most of the eluted λ-DNA was recovered in the second 2 µL of elution buffer with high-purity suitable for successful polymerase chain reaction amplification, making it possible for further integration into microfluidic devices for fully functional and high-throughput genetic analysis.  相似文献   

10.
We developed an integrated microfluidic chip for long-term culture of isolated single cells. This polydimethylsiloxane (PDMS) based device could accurately seed each single cell into different culture chambers, and isolate one chamber from each other with monolithically integrated pneumatic valves. We optimized the culture conditions, including the frequency of medium replacement and the introduction of conditioned medium, to keep the single cells alive for 4 days. We cultured a few hundred cells in a separated chamber on the same chip to continuously supply the conditioned medium into the culture chambers for single cells. This approach greatly facilitated the growth of single cells, and created a suitable microenvironment for observing cells’ autonomous process in situ without the interference of other adjacent cells. This single cell colony assay is expandable to higher throughput, fitting the needs in the studies of drug screening and stem cell differentiation.  相似文献   

11.
This paper presents the first systematic engineering study of the impact of chemical formulation and surface functionalization on the performace of free-standing microfluidic polymer elements used for high-pressure fluid control in glass microsystems. System design, chemical wet-etch processes, and laser-induced polymerization techniques are described, and parametric studies illustrate the effects of polymer formulation, glass surface modification, and geometric constraints on system performance parameters. In particular, this study shows that highly crosslinked and fluorinated polymers can overcome deficiencies in previously-reported microvalve architectures, particularly limited solvent compatibility. Substrate surface modification is shown effective in reducing the friction of the polymer-glass interface and thereby facilitating valve actuation. A microchip one-way valve constructed using this architecture shows a 2 x 10(8) ratio of forward and backward flow rates at 7 MPa. This valve architecture is integrated on chip with minimal dead volumes (70 pl), and should be applicable to systems (including chromatography and chemical synthesis devices) requiring high pressures and solvents of varying polarity.  相似文献   

12.
A sensitive enzyme-linked immunosorbent assay system has been constructed on microfluidic chips. The antibodies (anti-IgG) were encapsulated within the network of Al2O3 sol–gel in the microfluidic channels after the (BMA)x-(MAOPTMS)y copolymer modification. The alumina gel-derived microchannel surface can preserve the bioactivity of antibodies and resist nonspecific adsorption. After the immunoreaction of the antibodies, antigen, and alkaline phosphatase-labeled antibodies, a substrate solution containing 4-aminophenyl phosphate was introduced to the microchannels for end-column electrochemical detection. The microchip immunosensor showed a low detection limit (1 pg mL−1), and broad linear response range (1–500 pg mL−1). The results indicate that this method with high sensitivity and fast response has great potential for clinical and environmental analysis.  相似文献   

13.
Microfluidic chips combined with surface-enhanced Raman spectroscopy (SERS) offer an outstanding platform for rapid and high-sensitivity chemical analysis. However, it is nontrivial to conveniently form nanoparticle aggregrates (as SERS-active spots for SERS detection) in microchannels in a well-controlled manner. Here, we present a rapid, highly sensitive and label-free analytical technique for determining bovine serum albumin (BSA) on a poly(dimethylsiloxane) (PDMS) microfluidic chip using SERS. A modified PDMS pneumatic valve and nanopost arrays at the bottom of the fluidic microchannel are used for reversibly trapping gold nanoparticles to form gold aggregates, creating SERS-active spots for Raman detection. We fabricated a chip that consisted of a T-shaped fluidic channel and two modified pneumatic valves, which was suitable for fast loading of samples. Quantitative analysis of BSA is demonstrated with the measured peak intensity at 1,615 cm−1 in the surface-enhanced Raman spectra. With our microfluidic chip, the detection limit of Raman can reach as low as the picomolar level, comparable to that of normal mass spectrometry.  相似文献   

14.
We describe a programmable microfluidic system with onboard pumps and valves that has the ability to process reaction volumes in the sub-microlitre to hundred microlitre range. The flexibility of the architecture is demonstrated with a commercial molecular biology protocol for mRNA amplification, implemented without significant modification. The performance of the microchip system is compared to conventional bench processing at each stage of the multistep protocol, and DNA microarrays are used to assess the quality and performance of bench- and microchip-amplified RNA. The results show that the microchip system reactions are similar to bench control reactions at each step, and that the microchip- and bench-derived amplified RNAs are virtually indistinguishable in differential microarray analyses.  相似文献   

15.
The coulometric efficiency (Ceff) of an amperometric detector integrated on PDMS/glass capillary electrophoresis microfluidic device (microchip) has been enhanced by in-channel electrochemical modification. In-channel electrochemical deposition of gold particles was performed in order to vertically increase the surface area of the Au sensing microelectrode. The roughness of the electrodes was characterized using scanning electron microscopy and profilometric analysis. The degree of electrode modification was also characterized by roughness factor determination. Separation processes including detection potential was optimized and the analytical performance of the microchip was tested using a mixture of dopamine (DA) and catechol (CA). The modified electrochemical detector provided well-resolved separation of DA and CA in less than 60 s with enhanced sensitivity; no peak broadening was observed. The limit of detection using in-channel modification of working electrode for DA and CA are 60 and 110 nM, respectively. Thus, in-channel electrochemical deposition of metallic particles should be used to enhance the Ceff of integrated amperometric detection of analytes with good redox properties in order to obtain lower LODs.  相似文献   

16.
《Electrophoresis》2017,38(13-14):1743-1754
Integration in microfluidics is important for achieving automation. Sample preconcentration integrated with separation in a microfluidic setup can have a substantial impact on rapid analysis of low‐abundance disease biomarkers. Here, we have developed a microfluidic device that uses pH‐mediated solid‐phase extraction (SPE) for the enrichment and elution of preterm birth (PTB) biomarkers. Furthermore, this SPE module was integrated with microchip electrophoresis for combined enrichment and separation of multiple analytes, including a PTB peptide biomarker (P1). A reversed‐phase octyl methacrylate monolith was polymerized as the SPE medium in polyethylene glycol diacrylate modified cyclic olefin copolymer microfluidic channels. Eluent for pH‐mediated SPE of PTB biomarkers on the monolith was optimized using different pH values and ionic concentrations. Nearly 50‐fold enrichment was observed in single channel SPE devices for a low nanomolar solution of P1, with great elution time reproducibility (<7% RSD). The monolith binding capacity was determined to be 400 pg (0.2 pmol). A mixture of a model peptide (FA) and a PTB biomarker (P1) was extracted, eluted, injected, and then separated by microchip electrophoresis in our integrated device with ∼15‐fold enrichment. This device shows important progress towards an integrated electrokinetically operated platform for preconcentration and separation of biomarkers.  相似文献   

17.
Recently, sophisticated fluidic circuits with hundreds of independent valves have been built by using multi-layer soft-lithography to mold elastomers. However, this shrinking of microfluidic circuits has not been matched by a corresponding miniaturization of the actuation and interfacing elements that control the circuits; while the fluidic circuits are small ( approximately 10-100 micron wide channels), the Medusa's head-like interface, consisting of external pneumatic solenoids and tubing or mechanical pins to control each independent valve, is larger by one to four orders of magnitude (approximately mm to cm). Consequently, the dream of using large scale integration in microfluidics for portable, high throughput applications has been stymied. By combining multi-layer soft-lithography with shape memory alloys (SMA), we demonstrate electronically activated microfluidic components such as valves, pumps, latches and multiplexers, that are assembled on printed circuit boards (PCBs). Thus, high density, electronically controlled microfluidic chips can be integrated alongside standard opto-electronic components on a PCB. Furthermore, we introduce the idea of microfluidic states, which are combinations of valve states, and analogous to instruction sets of integrated circuit (IC) microprocessors. Microfluidic states may be represented in hardware or software, and we propose a control architecture that results in logarithmic reduction of external control lines. These developments bring us closer to building microfluidic circuits that resemble electronic ICs both physically, as well as in their abstract model.  相似文献   

18.
This paper reports a prototype for a standard connector between a microfluidic chip and the macro world. This prototype demonstrate a fully functioning socket for a microchip to access the outside world by means of fluids, data signals and energy supply. It supports up to 10 channels for the input and output of liquids or gases, as well as compressed air or vacuum lines for pneumatic power lines. The socket has built-in valves for each flow channel. It also contains 28 pins for the connection of electrical signals and power. Built-in valves make it possible to control the flow in each channel independently. A chip ( 11.0 x 11.0 x 0.9 mm) can be mounted into or dismounted from the socket with one touch. The fluidic connectors of the socket are designed to contact vertically on the top of chip. And the electrical connectors (the spring array) of that physically support the chip and contact lead pads at the bottom of chip. No adhesives or solders are used at any contact points. The pressure limit for the connection of working fluids was 0.2 MPa and the current limit for the electrical connections was 1 A. This socket supports both serial and parallel processing applications. It exhibits great potential for developing microfluidic systems efficiently.  相似文献   

19.
A PDMS‐based microfluidic system for online coupling of microdialysis sampling to microchip electrophoresis with fluorescence detection for in vivo analysis of amino acid neurotransmitters using naphthalene‐2,3‐dicarboxaldehyde and sodium cyanide as the derivatization reagents is described. Fabricating chips from PDMS rather than glass was found to be simpler and more reproducible, especially for chips with complex designs. The microchip incorporated a 20‐cm serpentine channel in which sample plugs were introduced using a “simple” injection scheme; this made fluid handling and injection on‐chip easier for the online system compared with gated or valve‐based injection. The microchip was evaluated offline for the analysis of amino acid standards and rat brain microdialysis samples. Next, precolumn derivatization was incorporated into the chip and in vivo online microdialysis‐microchip electrophoresis studies were performed. The system was employed for the continuous monitoring of amino acid neurotransmitters in the extracellular fluid of the brain of an anesthetized rat. Fluorescein was dosed intravenously and monitored simultaneously online as a marker of in vivo blood–brain barrier permeability. The microdialysis‐microchip electrophoresis system described here will be employed in the future for simultaneous monitoring of changes in blood–brain barrier permeability and levels of amino acid neurotransmitters in the rat stroke model.  相似文献   

20.
Well-defined water-dispersible polyaniline (PANI) nanoparticles were synthesized by in situ chemical oxidative polymerization of aniline in the presence of an amphiphilic P(AMPS-co-VM) copolymer micelle. P(AMPS-co-VM) copolymer was prepared by the free radical polymerization of 7-(4-vinylbenzyloxyl)-4-methyl-coumarin (VM) and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) which can self-assemble into micelles in aqueous solution. Here, P(AMPS-co-VM) copolymer micelle is used not only as soft template but also as acid dopant in our reaction system. The structure, size, and morphology of PANI nanoparticles were characterized by various experimental techniques. It is found that the morphology and the size of the PANI nanoparticles strongly depend on the molecular characteristics of the P(AMPS-co-VM) copolymer. The synthesized PANI nanoparticles behaved as particulate emulsifier for the stabilization of oil-in-water emulsions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号