首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes the fabrication and use of a biomimetic microfluidic device for the monitoring of a functional porin reconstituted within a miniaturized suspended artificial bilayer lipid membrane (BLM). Such a microfluidic device allows for (1) fluidic and electrical access to both sides of the BLM and (2) reproducible membrane protein insertion and long-term electrical monitoring of its conductance (G(i)), thanks to the miniaturization of the BLM. We demonstrate here for the first time the feasibility to insert a large trans-membrane protein through its β-barrel, and monitor its functional activity for more than 1 hour (limited by buffer evaporation). In this paper, we specifically used our device for the monitoring of OprM, a bacterial efflux channel involved in the multidrug resistance of the bacteria Pseudomonas aeruginosa. Sub-steps of the OprM channel conductance were detected during the electrical recordings within our device, which might be due to oscillations between several structural conformations (sub-states) adopted by the protein, as part of its opening mechanism. This work is a first step towards the establishment of a genuine platform dedicated to the investigation of bacterial proteins under reconstituted conditions, a very promising tool for the screening of new inhibitors against bacterial channels involved in drug resistance.  相似文献   

2.
This communication presents an instrumental development based on the printed circuit board (PCB) technology to integrate electrochemiluminescence (ECL) analysis in microfluidic systems. PCB gold macro- (10 mm2) and micro- (0.09 mm2) electrodes and two ECL microfluidic devices are designed, fabricated and tested via luminol ECL detection. Potential modulation is performed between 0.7 and 0 V vs. Ag/AgCl for luminol oxidation, thus giving rise to on/off ECL responses in the presence of hydrogen peroxide. Synchronous detection is adopted to allow weak ECL signal recovery at a very low signal-to-noise ratio (SNR). The detection limit obtained with the two ECL microfluidic devices is 50 nM and 100 nM H2O2 for macroelectrodes and microelectrodes, respectively.  相似文献   

3.
We use direct femtosecond laser writing to integrate optical waveguides into a commercial fused silica capillary electrophoresis chip. High-quality waveguides crossing the microfluidic channels are fabricated and used to optically address, with high spatial selectivity, their content. Fluorescence from the optically excited volume is efficiently collected at a 90° angle by a high numerical aperture fiber, resulting in a highly compact and portable device. To test the platform we performed electrophoresis and detection of a 23-mer oligonucleotide plug. Our approach is quite powerful because it allows the integration of photonic functionalities, by simple post-processing, into commercial LOCs fabricated with standard techniques. Figure Femtosecond laser written waveguides can selectively excite fluorescence in a microfluidic channel of a commercial lab-on-a-chip. A compact scheme for on-chip detection by laser induced fluorescence is applied to capillary electrophoresis of a 23-mer Cy3-labeled oligonucleotide  相似文献   

4.
A simple pyridinium-based chiral receptor 1 containing l-valine as the chiral source has been designed and synthesized. The receptor 1 fluorometrically recognizes d-lactate over l-lactate in CH3CN with an enantiomeric fluorescence ratio (ef) of 5.32.  相似文献   

5.
C-reactive protein (CRP) was determined in the concentration range 0.01–10 mg L−1 using hot electron induced electrochemiluminescence (HECL) with devices combining both working and counter electrodes and sample confinement on a single chip. The sample area on the electrodes was defined by a hydrophobic ring, which enabled dispensing the reagents and the analyte directly on the electrode. Immunoassay of CRP by HECL using integrated electrodes is a good candidate for a high-sensitivity point-of-care CRP-test, because the concentration range is suitable, miniaturisation of the measurement system has been demonstrated and the assay method with integrated electrodes is easy to use. High-sensitivity CRP tests can be used to monitor the current state of cardiovascular disease and also to predict future cardiovascular problems in apparently healthy people.  相似文献   

6.
7.
Point-of-care testing(POCT) technology is highly desirable for clinical diagnosis, healthcare monitoring,food safety inspection, and environment surveillance, because it enables rapid detection anywhere, anytime, and by anyone. Electrochemiluminescence(ECL) has been widely used in chemo-/bio analysis due to its advantages such as high sensitivity, simplicity, rapidity and easy to control, and is now attracting increasing attention for POCT applications. However, to realize the accurate on-site q...  相似文献   

8.
《中国化学快报》2023,34(3):107573
In this paper, we designed a three-dimensional cell co-cultured microfluidic chip, which generated interstitial flow and oxygen gradient to simulate the complex tumor microenvironment. It consisted of five parallel cell culture channels and one hypoxic channel. These channels were constructed for the culture of mouse liver tumor cells (Hepa1-6), mouse liver stellate cells (JS-1), the simulation of extracellular matrix, complex biochemical factors (hypoxia and interstitial flow), and the supply of cellular nutrients. The 3D-interstitial flow-hypoxia model was used to study the behavior of JS-1 cells under the effect of tumor microenvironment (TME). The results showed that by co-cultured with Hepa1-6 cells, hypoxia of Hepa1-6 cells, and adding TGF-β1 by interstitial flow, the migration of JS-1 cells could be promoted. Similarly, activated JS-1 cells could led to the epithelial-mesenchymal transformation in co-cultured Hepa1-6 cells, which secreted more TGF-β1.  相似文献   

9.
10.
Hong JW  Chung KH  Yoon HC 《The Analyst》2008,133(4):499-504
An application of a novel polymer microfluidic chip for sample exchange via natural capillary forces for immuno-analysis is described. The microfluidic device was designed to achieve sample replacement by capillary force only, which would therefore be suitable for point-of-care-testing. Complete and automatic replacement of the sample in the reaction chamber with another one makes the chip able to mimic affinity chromatography and immunoassay processes. The microfluidic chip was made using polymer replication techniques, which were suitable for fast and cheap fabrication. Micrometre-sized polystyrene beads were used for the functionalization of biomolecules. Dinitrophenyl (DNP) and anti-DNP antibody coordination was employed on the chip for fluorescence analysis. DNP was immobilized on the polymer beads via a pre-adsorbed dendrimer layer and the beads were placed in the reaction chamber. Fluorescein tagged anti-DNP was successfully observed by a fluorescence microscope after the completion of the entire flow sequence. A calibration curve was registered based on the anti-DNP concentration. A multiplex sensing was accomplished by adding biotin/streptavidin coordination to the system. DNP and biotin conjugated beads were placed in the reaction chamber in an ordered fashion and biospecific bindings of anti-DNP antibody and streptavidin were observed at their expected sites. A ratiometric analysis was carried out with different concentration ratios of anti-DNP/streptavidin. The microfluidic chip described in this work could be applied to various biological and chemical analyses using integrated washing steps or fluid replacement steps with minimum sample handling.  相似文献   

11.
Efforts to improve the in vitro embryo production process in pigs have included modifying culture medium and number of spermatozoa inseminated in order to reduce the incidence of polyspermy. Polyspermy is a pathological condition which results in aberrant embryonic development. The microchannels are designed to more closely mimic the function of the oviduct and create a flow pattern of spermatozoa past the oocytes similar to the pattern in the oviduct. In vitro fertilization of porcine oocytes in the microchannels has produced a higher incidence of monospermic penetration (p<0.05) as compared to the oocytes fertilized in the traditional microdrop system with comparable penetration and male pronucleus formation rates. Additionally, cleavage rates of the embryos as well as development to the blastocyst stage are similar. Here we demonstrate that the biomimetic microchannel in vitro fertilization system can reduce polyspermy and, therefore, increase the number of potentially viable embryos without reducing the overall in vitro production efficiency.  相似文献   

12.
Polymerization reactions are based on complex processes that are somewhat difficult to predict via mathematical models, especially without experimental data. A method to investigate the cure of epoxies via in-situ Raman spectroscopy has been developed.Differential Scanning Calorimetry (DSC) is the industry-standard method for determining the cure of a polymer, but it is a labor-intensive method that is also fairly slow. Raman spectroscopy was used to monitor the cure chemistry of DGEBA (Diglycidyl Ether of Bisphenol A) and to observe in-situ the evolution of the reticulation.  相似文献   

13.
We report enhanced sample confinement on microfluidic devices using a combination of electrokinetic flow from adjacent control channels and electric field shaping with an array of channels perpendicular to the sample stream. The basic device design consisted of a single first dimension (1D) channel, intersecting an array of 32 or 96 parallel second dimension (2D) channels. To minimize sample dispersion and leakage into the parallel channels as the sample traversed the sample transfer region, control channels were placed to the left and right of the 1D and waste channels. The electrokinetic flow from the control channels confined the sample stream and acted as a buffer between the sample stream and the 2D channels. To further enhance sample confinement, the electric field was shaped parallel to the sample stream by placing the channel array in close proximity to the sample transfer region. Using COMSOL Multiphysics, initial work focused on simulating the electric fields and fluid flows in various device geometries, and the results guided device design. Following the design phase, we fabricated devices with 40, 80, and 120 microm wide control channels and evaluated the sample stream width as a function of the electric field strength ratio in the control and 1D channels (E(C)/E(1D)). For the 32 channel design, the 40 and 80 microm wide control channels produced the most effective sample confinement with stream widths as narrow as 75 microm, and for the 96 channel design, all three control channel widths generated comparable sample stream widths. Comparison of the 32 and 96 channel designs showed sample confinement scaled easily with the length of the sample transfer region.  相似文献   

14.
In-situ monitoring of pesticide residues during crop growth or/and in related products is of great significance in avoiding the abuse of pesticides but remains challenging thus far. In this report, we proposed a background-free surface-enhanced Raman spectroscopy(bf-SERS) platform to non-destructively track the nitrile-bearing pesticide residues in soybean leaves with high sensitivity and selectivity. The outstanding feature of the assay stems from the dramatic Raman enhancement effect of the 50...  相似文献   

15.
A series of semicrystalline block copolymers (BCPs), poly(4-vinylpyridine)-block-poly(ε-caprolactone) (P4VP-PCL), with lamellar phases have been synthesized. P4VP-PCL BCP thin films with large-scale, oriented lamellar microdomains were obtained by rimming coating process followed by oscillated shearing using a homemade shear device. Owing to the vitrified P4VP microdomains and strongly segregated microphase separation, specific PCL crystalline chain orientation can be formed from the growth of anisotropic PCL crystallites under confinement so as to uniformly increase the birefringence of the BCP thin films. The enhanced birefringence corresponds well with the increase of PCL crystallinity. Consequently, the birefringence of the P4VP-PCL thin-films can be fine-tuned by PCL crystallization. The variation on the birefringence of the BCP thin films attributed to crystallization and melting is a reversible process with respect to temperature. The BCP thin films can thus be used as temperature-stimulated materials with controllable birefringence via crystallization kinetics.  相似文献   

16.
Gac SL  Zwaan E  van den Berg A  Ohl CD 《Lab on a chip》2007,7(12):1666-1672
We report here the sonoporation of HL60 (human promyelocytic leukemia) suspension cells in a microfluidic confinement using a single laser-induced cavitation bubble. Cavitation bubbles can induce membrane poration of cells located in their close vicinity. Membrane integrity of suspension cells placed in a microfluidic chamber is probed through either the calcein release out of calcein-loaded cells or the uptake of trypan blue. Cells that are located farther away than four times Rmax (maximum bubble radius) from the cavitation bubble center remain fully unaffected, while cells closer than 0.75 Rmax become porated with a probability of >75%. These results enable us to define a distance of 0.75 Rmax as a critical interaction distance of the cavitation bubble with HL60 suspension cells. These experiments suggest that flow-induced poration of suspension cells is applicable in lab-on-a-chip systems, and this might be an interesting alternative to electroporation.  相似文献   

17.
The processes occurring during the early stages of the formation of crystalline solids are not well understood thus preventing the rational synthesis of new solids. The investigation of the structure-forming processes is an enormous challenge for both analytical and theoretical methods because very small particles or aggregates with different chemical composition and different sizes must be probed, both before and during nucleation. Furthermore, these precursors are present in a complex and dynamic equilibrium. This Review gives a survey of the in-situ methods available for the study of the early stages of crystallization of solids and how they can help in the synthesis of metastable polymorphs, of transient intermediates, and/or precursors displaying new or improved properties. Examples of actual research demonstrate the necessity and potentials but also the limitations of in-situ monitoring of the formation of crystalline solids.  相似文献   

18.
Haghighi B  Bozorgzadeh S 《Talanta》2011,85(4):2189-2193
ZnO nanoparticles (nanoZnO) were decorated on multiwalled carbon nanotubes (MWCNTs) and then the prepared nano-hybrids, nanoZnO-MWCNTs, were immobilized on the surface of a glassy carbon electrode (GCE) to fabricate nanoZnO-MWCNTs modified GCE. The prepared electrode, GCE/nanoZnO-MWCNTs, showed excellent electrocatalytic activity towards luminol electrochemiluminescence (ECL) reaction. The electrode was then further modified with lactate oxidase and Nafion to fabricate a highly sensitive ECL lactate biosensor. Two linear dynamic ranges of 0.01-10 μmol L−1 and 10-200 μmol L−1 were obtained for lactate with the correlation coefficient better than 0.9996. The detection limit (S/N = 3) was 4 nmol L−1 lactate. The relative standard deviation for repetitive measurements (n = 6) of 10 μmol L−1 lactate was 1.5%. The fabrication reproducibility for five biosensors prepared and used in different days was 7.4%. The proposed ECL lactate biosensor was used for determination of lactate in human blood plasma samples with satisfactory results.  相似文献   

19.
《中国化学快报》2023,34(3):107384
Perovskite quantum dots (PQDs) possess remarkable optical properties, such as tunable photoluminescence (PL) emission spectra, narrow full width at half maximum (FWHM) and high PL quantum yield (QY), endowing the PQDs great application prospects. However, the inherent structural instability of PQDs has seriously hindered the application of PQDs in various photoelectric devices. In this work, a microfluidic electrospinning method was used to fabricate color-tunable fluorescent formamidinium lead halogen (FAPbX3, X = Cl, Br, I) PQDs/polymer core-shell nanofiber films. The core-shell spinning nanofiber not only supplies the interspace for the in-situ formation of PQDs, but also significantly reduces the permeability of moisture and oxygen in the air, which greatly improves the stability of PQDs. After adjusting the composition of precursors, the blue-emissive polystyrene (core) and polymethyl methacrylate (shell) coated FAPbCl3 QDs (abbreviated as PS/FAPbCl3/PMMA, hereinafter), green-emissive PS/FAPbBr3/PMMA and red-emissive PS/FAPbI3/PMMA nanofiber films were fabricated with the highest PL QY of 82.3%. Moreover, the PS/FAPbBr3/PMMA nanofiber film exhibits great PL stability under blue light irradiation, long-term storage in the air and water resistance test. Finally, the green- and red-emissive nanofiber films were directly applied as light conversion films to fabricate wide-color-gamut display with the color gamut of 125%, indicating their tremendous potentials in optoelectronic applications.  相似文献   

20.
The dewetting behavior of thin polystyrene (PS) film has been investigated by placing an upper plate with a ca. 140 nm gap from the underlying substrate with the spin-coated thin polymer films. Three different kinds of dewetting behaviors of thin PS film have been observed after annealing according to the relative position of the PS film to the upper plate. Since the upper plate is smaller than the underlying substrate, a part of the polymer film is not covered by the plate. In this region (I), thin PS film dewetting occurs in a conventional manner, as previously reported. While in the region covered by the upper plate (III), the PS film exhibits unusual dewetted patterns. Meanwhile, in the area right under the edge of the plate (II) (i.e., the area between region I and region III), highly ordered arrays of PS droplets are formed. Formation mechanisms of different dewetted patterns are discussed in detail. This study may offer an effective way to improve the understanding of various dewetting behaviors and facilitate the ongoing exploration of utilizing dewetting as a patterning technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号