首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Membrane-assisted solvent extraction was applied to the determination of polychlorinated biphenyls (PCBs) in aqueous samples. The apparatus of membrane-assisted solvent extraction consisted of a 20 ml headspace vial which was filled with 15 ml of the aqueous sample. The membrane bag was placed into the vial and the extraction took place in an agitator. After extraction, the analytes were transferred into the inlet of a gas chromatograph by large volume injection. A mass-selective detector was used. The whole procedure was fully automated. The work included optimization of the extraction conditions (stirring rate and extraction time) and the influence of matrix effects like salt addition and the presence of organic solvents was studied. Calibration was performed using injection volumes of 100 and 400 microl. Several parameters like linearity and reproducibility of the procedure were determined. At optimized conditions detection limits in the ng/l range were achieved. The effectiveness of the method towards real samples was tested by analyzing river water, white wine and apple juice.  相似文献   

2.
Eight organophosphorus pesticides (parathion-methyl, fenitrothion, malathion, fenthion, bromophos, bromophos-ethyl, fenamiphos and ethion) in aqueous samples were analysed by means of membrane-assisted solvent extraction. First a 20 ml extraction vial was filled with 15 ml of aqueous sample. Then the membrane bag consisting of nonporous polypropylene was put into the vial and filled with 800 microl of organic solvent. The analytes were separated from the aqueous layer by transporting them through the membrane material into the small amount of solvent. The technique was fully automated and successfully combinable with large volume extraction and GC-MS. To achieve an optimum performance several extraction conditions were investigated. Cyclohexane was chosen as acceptor phase. Then the impact of salt, methanol, pH value, as well as working parameters like stirring rate of the agitator and extraction time, were studied. Moreover, the influence of matrix effects was examined by adding different concentrations of humic acid sodium salt. Detection limits in the ng/l level were achieved using large volume injection with the injecting volume of 100 microl. The recovery values ranged from 47 to 100% and the relative standard deviation for three standard measurements was between 4 and 12% (except for bromophos-ethyl: 22%). The linear dynamic range was between 0.001 and 70 microg/l. The applicability of the method to real samples was tested by spiking the eight organophosphorus pesticides to red wine, white wine and apple juice samples.  相似文献   

3.
A sensitive and automated method is presented for the determination of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter. The procedure includes extraction of PM10-bound PAHs by accelerated solvent extraction (ASE) followed by gel permeation chromatography (GPC) clean-up, and large-volume programmable temperature vaporizer (PTV-LV) injection coupled to GC-MS. The limit of detection (LOD) of the whole method, based on a signal-to-noise ratio (S/N) of 3:1, ranged from 0.26 pg m−3 to 3 pg m−3 when air volumes of 760 m3 are collected.The hexane-acetone mixture (1:1, v/v) gave the best recoveries when ASE parameters were fixed at 125 °C, 1500 psi, and a total time of 10 min. The recoveries for all PAHs tested ranged from 96% to 103%, rates similar to those obtained by the Soxhlet reference method.To improve the sensitivity, 70 μL were injected. The PTV-LV injection settings were optimized using a statistical design of experiments, including a screening 24 full factorial design and a further central composite design. A sensitivity increase from 10 to 50 times was achieved as compared with the conventional 2 μL splitless injection.The method was validated with the standard reference material SRM 1649a and applied to real PM10 samples from the monitoring network of the Regional Valencia Government (Spain).The analytical performance of the method shows that it is appropriate to monitor PAHs levels in ambient air according to European Union Directives. In addition, the method can be used when a high sensitivity is required.  相似文献   

4.
Membrane-assisted solvent extraction (MASE) in combination with large volume injection-gas chromatography-mass spectrometry (LVI-GC-MS) was applied for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. The MASE conditions were optimized for achieving high enrichment of the analytes from aqueous samples, in terms of extraction conditions (shaking speed, extraction temperature and time), extraction solvent and composition (ionic strength, sample pH and presence of organic solvent). Parameters like linearity and reproducibility of the procedure were determined. The extraction efficiency was above 65% for all the analytes and the relative standard deviation (RSD) for five consecutive extractions ranged from 6 to 18%. At optimized conditions detection limits at the ng/L level were achieved. The effectiveness of the method was tested by analyzing real samples, such as river water, apple juice, red wine and milk.  相似文献   

5.
Stir‐bar sorptive extraction and liquid desorption followed by large volume injection‐gas chromatography coupled to mass spectrometry under selected ion monitoring mode acquisition (SBSE‐LD/LVI‐GC‐MS(SIM)) was applied for the determination of six benzotriazole UV stabilizers (Tinuvin P, Allyl‐bzt, Tinuvin 320, Tinuvin 326, Tinuvin 327 and Tinuvin 328) in wastewater matrices. Parameters affecting the performance of extraction and desorption steps were thoroughly evaluated using uni‐ and multivariate optimization strategies, based on the use of experimental factorial designs. Assays performed with stir bars, coated with 24 μL of polydimethylsiloxane, on 25 mL of ultra‐pure water samples spiked at the 0.5 ng/mL level, yielded recoveries ranging from 47.9±1.4% (Tinuvin P) to 103.1±3.6% (Tinuvin 326), under optimized experimental conditions. When applied to complex matrices (e.g. wastewater), the methodology showed also excellent linear dynamic ranges (0.02–10.00 ng/mL) for the six benzotriazole UV stabilizers studied with correlation coefficients higher than 0.9970, limits of quantification in between 0.004 and 0.015 ng/mL, suitable repeatability (RSD<12.7%) and reproducibility (RSD<4.5%). The application of the proposed methodology to urban sewage waters from Spain and Portugal wastewater plants revealed the presence of low contents of some benzotriazole UV stabilizers.  相似文献   

6.
Stir bar sorptive extraction and liquid desorption followed by large volume injection coupled to gas chromatography-quadrupole mass spectrometry (SBSE-LD/LVI-GC-qMS) had been applied for the determination of volatiles in wines. The methodology was optimised in terms of extraction time and influence of ethanol in the matrix; LD conditions, and instrumental settings. The optimisation was carried out by using 10 standards representative of the main chemical families of wine, i.e. guaiazulene, E,E-farnesol, β-ionone, geranylacetone, ethyl decanoate, β-citronellol, 2-phenylethanol, linalool, hexyl acetate and hexanol. The methodology shows good linearity over the concentration range tested, with correlation coefficients higher than 0.9821, a good reproducibility was attained (8.9-17.8%), and low detection limits were achieved for nine volatile compounds (0.05-9.09 μg L−1), with the exception of 2-phenylethanol due to low recovery by SBSE. The analytical ability of the SBSE-LD/LVI-GC-qMS methodology was tested in real matrices, such as sparkling and table wines using analytical curves prepared by using the 10 standards where each one was applied to quantify the structurally related compounds. This methodology allowed, in a single run, the quantification of 67 wine volatiles at levels lower than their respective olfactory thresholds. The proposed methodology demonstrated to be easy to work-up, reliable, sensitive and with low sample requirement to monitor the volatile fraction of wine.  相似文献   

7.
The on-line coupling of a liquid-liquid extraction system with capillary gas chromatography using atomic emission detection (GC-AED) has been studied. The required large volumes of about 100 μl of an iso-octane solution can be introduced into the GC-AED system by using the AED solvent vent and a solvent vapor exit in front of the capillary analytical column. Test solutions containing several pesticides were detected using the carbon, chlorine, nitrogen and sulfur channels. Analyte detectability (in concentration units) was improved significantly and low concentractions of the test compounds could be determined (1–5 ng/ml). Aqueous samples were on-line extracted and analyzed. The precision of the large-volume injection itself as well as the total extraction-GC-AED system was satisfactory (RSD of ca. 2 and 4%, respectively). As a real-life application, several ground water samples were screened.  相似文献   

8.
A 3-step analytical procedure was developed and optimized for the simultaneous determination of 6 phenols (phenol, o-, m-, p-cresol, catechol and resorcinol) and 19 chlorophenols (all mono-, di-, tri-, and tetrachlorophenol isomers and pentachlorophenol) from environmental water samples. The analytical scheme consists of (1) solid-phase extraction (SPE) carried out on hypercrosslinked styrene-divinylbenzene (Isolute ENV+) cartridge; (2) derivatization with trimethylsilyl-N,N-dimethylcarbamate (TMSDMC); (3) analysis of the derivatives with capillary gas chromatography-mass spectrometry, in the selective ion monitoring mode. Ethyl acetate, ethyl acetate/acetic acid (5 v/v%) mixture, dichloromethane and acetonitrile were compared as to their ability to elute the phenols and chlorophenols from the ENV + sorbent in the smallest solvent volume possible. The optimized extraction step uses a minimal amount of organic solvent (4 mL ethyl acetate). Derivatization of the phenols and chlorophenols with TMSDMC was studied with respect to conversion, reagent excess, medium, temperature and the stability of the trimethylsilyl derivatives. If the reagent is applied in sufficient excess, the reaction takes place instantaneously at room temperature, and the derivatives remain stable for 24 h, making the procedure simple, fast and convenient. The overall method gave detection limits of 0.05-100 ng/L for all compounds except resorcinol which could not be retained on the SPE cartridge. The complete optimized analytical scheme was applied to ground water and river water samples collected in Hungary.  相似文献   

9.
This study describes an SPE coupled with large volume injection (LVI) analytical method for the analysis of organochlorine pesticides, BHC (alpha, beta, delta), aldrin, endosulfan (alpha, beta), endrin, dieldrin, and DDT, from aqueous samples. Determination was carried out by GC with MS. The LODs of organochlorine pesticides were determined at 10 ng/L concentration levels, and the results show that SPE-LVI-GC/MS has the potential to accurately determine organochlorine pesticides in water, as it avoids analyte classes in the various steps of a typical extraction procedure.  相似文献   

10.
A method combining accelerated solvent extraction with dispersive liquid–liquid microextraction was developed for the first time as a sample pretreatment for the rapid analysis of phenols (including phenol, m‐cresol, 2,4‐dichlorophenol, and 2,4,6‐trichlorophenol) in soil samples. In the accelerated solvent extraction procedure, water was used as an extraction solvent, and phenols were extracted from soil samples into water. The dispersive liquid–liquid microextraction technique was then performed on the obtained aqueous solution. Important accelerated solvent extraction and dispersive liquid–liquid microextraction parameters were investigated and optimized. Under optimized conditions, the new method provided wide linearity (6.1–3080 ng/g), low limits of detection (0.06–1.83 ng/g), and excellent reproducibility (<10%) for phenols. Four real soil samples were analyzed by the proposed method to assess its applicability. Experimental results showed that the soil samples were free of our target compounds, and average recoveries were in the range of 87.9–110%. These findings indicate that accelerated solvent extraction with dispersive liquid–liquid microextraction as a sample pretreatment procedure coupled with gas chromatography and mass spectrometry is an excellent method for the rapid analysis of trace levels of phenols in environmental soil samples.  相似文献   

11.
A fully automated protocol consisting of microextraction by packed sorbents (MEPS) coupled with large volume injection-in-port-derivatization-gas chromatography–mass spectrometry (LVI-derivatization-GC–MS) was developed to determine endocrine disrupting compounds (EDCs) such as alkylphenols, bisphenol A, and natural and synthetic hormons in river and waste water samples. During method optimization, the extraction parameters as ion strength of the water sample, the MEPS extraction regime, the volume of organic solvent used for the elution/injection step, the type of elution solvents and the selectivity of the sorbents were studied. For optimum in-port-derivatization, 10 μL of the derivatization reagent N,O-bis(trimethylsilyl)triufloroacetamide with 1% of trimethylchlorosilane (BSTFA + 1% TMCS) was used. 17β-Estradiol-molecularly imprinted polymer (MIP) and silica gel (modified with C-18) sorbents were examined for the enrichment of the target analytes from water samples and the obtained results revealed the high selectivity of the MIP material for extraction of substances with estrogen-like structures. Recovery values for most of the analytes ranged from 75 to 109% for the C18 sorbent and from 81 to 103% for the MIP material except for equilin (on C18 with only 57–66% recovery). Precision (n = 4) of the entire analysis protocol ranged between 4% and 22% with both sorbents. Limits of detection (LODs) were at the low ng L−1 level (0.02–87, C18 and 1.3–22, MIP) for the target analytes.  相似文献   

12.
An injector liner packed with a plug of glass wool is compared with a laminar and a mini laminar liner for large volume (20-50 microL) splitless injection with concurrent solvent recondensation (CSR-LV splitless injection). Videos from experiments with perylene solutions injected into imitation injectors show that glass wool perfectly arrested the sample liquid and kept it in place until the solvent had evaporated. The sample must be transferred from the needle to the glass wool as a band, avoiding 'thermospraying' by partial solvent evaporation inside the needle. The liquid contacted the liner wall when the band was directed towards it, but from there it was largely diverted to the glass wool. In the laminar liners, part of the liquid remained and evaporated at the entrance of the obstacle, while the other proceeded to the center cavity. Vapors formed in the center cavity drove liquid from the entrance of the obstacle upwards, but the importance of such problems could not be verified in the real injector. Some liquid split into small droplets broke through the obstacle and entered the column. Breakthrough through the laminar liners was confirmed by a chromatographic experiment. An improved design of a laminar liner for large volume injection is discussed as a promising alternative if glass wool causes problems originating from insufficient inertness.  相似文献   

13.
Large volume injection-programmable temperature vaporization-gas chromatography-mass spectrometry (LVI-PTV-GC-MS) was optimized for the determination of estrone (E1), 17β-estradiol (E2), 17α-ethynyl estradiol (EE2), mestranol (MeEE2) and estriol (E3) for their determination in environmental samples (estuarine water, wastewater, fish bile and fish homogenate) after derivatization with 25 μL (BSTFA+1% TMCS) and 125 μL of pyridine. Experimental designs such as Plackett-Burman (PBD) and central composite designs (CCDs) were used to optimize the LVI-PTV variables (cryo-focusing temperature, vent time, vent flow, vent pressure, injection volume, purge flow to split vent, splitless time and injection speed). Optimized conditions were as follows: 45 μL of n-hexane extract are injected at 60°C and 6 μL/s with a vent flow and a vent pressure of 50 mL/min and 7.7 psi, respectively, during 5 min; then the split valve is closed for 1.5 min and afterwards the injector is cleaned at 100 mL/min before the next injection. The method was applied to the determination of estrogenic compounds in environmental samples such as estuarine water, wastewater, and fish homogenate and bile. Limits of detection (0.04-0.15 ng/L for water samples, 0.04-0.67 ng/g for fish bile and 0.1-7.5 ng for fish homogenate) obtained were approx. ten times lower than those obtained by means of a common split/splitless inlet.  相似文献   

14.
Persistent organic pollutants remain a serious threat to many food-chain systems. New pollutants continue to emerge. The present study has created novel extraction vessels which are compatible with readily available commercial instrumentation to validate the analysis of one class of persistent organic pollutants, polychlorinated biphenyls (PCBs), in avian blood. The volumes used can be reasonably sampled without sacrificing individuals, or comprising breeding or migratorial success. The procedure consists of the pressurized solvent extraction (PSE) of analytes in a novel PSE extraction vessel. The new extraction cell contains a 38-cm long, coiled, re-packable, in situ clean-up column. Lipid elimination, using Florisil, occurs within the coiled region of the extraction vessel, eliminating the requirement for post extraction clean-up. For development, 0.2 g samples of chicken whole blood have been used. Extract volumes are reduced from (30 to 10) cm3, compared to unmodified systems. The new PSE vessel with its integrated clean-up method showed satisfactory performance for the analysis of ten environmentally relevant PCB congeners in chicken whole blood samples with recoveries in the range of (70-130)%. Detection limits using gas chromatography coupled with large volume injection ion-trap mass spectrometry (GC-LVI-ITMS-MS) were in the range of (0.05-0.5) ng g−1. The relative standard deviations for all congeners investigated were better than 5%. This is the first PSE validation to have been conducted on unaltered whole blood samples.  相似文献   

15.
Li P  Zhang X  Hu B 《Journal of chromatography. A》2011,1218(52):9414-9421
In this paper, a novel sample pretreatment technique termed phase transfer based liquid-liquid-liquid microextraction (PT-LLLME) was proposed for the simultaneous extraction of inorganic and organic mercury species. In PT-LLLME, an intermediate solvent (acetonitrile) was added into the donor phase to improve the contacting between target mercury species and complexing reagent. Meanwhile, a membrane supported (MS)-LLLME unit was designed to realize the PT-LLLME procedure. By using nylon membrane as supporting carrier, larger than 50 μL of acceptor solution could be hung up. Following PT/MS-LLLME, the acceptor solutions were directly analyzed by large volume sample stacking capillary electrophoresis/ultraviolet detection (LVSS-CE/UV). Accordingly, a new method of PT/MS-LLLME combined with LVSS-CE/UV was developed for the simultaneous speciation of inorganic and organic mercury species. Parameters affecting the extraction efficiency of PT/MS-LLLME were investigated in details. Under the optimized conditions, enrichment factors (EFs) ranging from 160- to 478-fold were obtained for the extraction of target mercury species by PT/MS-LLLME. By combining PT/MS-LLLME with LVSS-CE/UV, EFs were magnified up to 12,138-fold and the limits of detection (at a signal-to-noise ratio of 3) were at sub ppb level. The established approach of PT/MS-LLLME-LVSS-CE/UV was successfully applied to simultaneous determination of inorganic and organic mercury species in biological samples and environmental water samples.  相似文献   

16.
《Comptes Rendus Chimie》2016,19(6):707-717
Using water as a green solvent with a variable geometry makes use of physical and chemical phenomena that are fundamentally different from those applied in conventional extraction techniques such as hydro-distillation, steam distillation or solvent extraction. Advantages and drawbacks of using water as a solvent with different physical and chemical states have been compared. A total of ten extraction techniques: hydro-distillation (HD), steam distillation (SD), turbo-hydro-distillation (THD), salt-hydro-distillation (NaCL-HD), enzyme-hydro-distillation (Enzyme-HD), micelle-hydro-distillation (Micelle-HD), ultrasound-hydro-distillation (US-HD) or subcritical water-hydro-distillation (SW-HD), solvent-free microwave extraction (SFME) and microwave steam distillation (MSD) were used to extract the essential oil from lavender (Lavandula L.) and their results were compared. The quantity was measured by the yield of essential oil and the quality was evaluated using the oil composition especially the content of linalyl acetate, linalool and terpin-4-ol compared with the corresponding control sample: Hydro-distillation. For environmentally friendly of the process: extraction time, total energy consumption and CO2 emission were considered and compared with conventional hydro-distillation. The mechanism explaining the linalyl acetate degradation has been resolved by using COSMO-RS software. Based on the present experimental conditions, it is recommended that lavender oil may be produced preferably by steam distillation assisted by microwave extraction to reduce the by-product formation by various chemical reactions and to get better oil recoveries.  相似文献   

17.
18.
Microwave-assisted extraction (MAE) of nonylphenols (NP), nonylphenol mono- and diethoxylates (NP1EO and NP2EO, respectively) and phthalate esters was optimised using an experimental design approach. A D-optimal mixture design was used to optimise the pressure inside the extraction vessel (110-207 kPa), the extraction time (5-25 min) and the extraction solvent (methanol, acetone or n-hexane) or the solvent mixture for the microwave-assisted extraction. Percentage of microwave power (80%) and solvent volume (15 ml) were fixed in all the experiments. As a consequence, the optimum extraction of these compounds was carried out at an intermediate pressure (159 kPa) with pure methanol and during 15 min. Moreover, solid phase extraction was also optimised for the clean-up of the extracts and C-18, LiChrolut® and Oasis® cartridges were studied in order to obtain the best recoveries of the compounds of interest. The highest recoveries were obtained with LiChrolut® cartridges after the elution with ethyl acetate. The cleaned extracts were analysed in a gas chromatograph with mass spectrometric detection and in a liquid chromatograph with diode array and fluorescence detection (HPLC-DAD-UV-FLD). The same sediment was also extracted twice in order to check that an exhaustive extraction of the analytes had occurred. Finally, the optimised extraction method was compared with pressurised solvent extraction (PSE), using an estuarine sediment sample.  相似文献   

19.
20.
An extraction-anodic adsorptive stripping voltammetric procedure using microwave-assisted solvent extraction and a gold ultramicroelectrode was developed for determining the pesticide ametryn in soil samples. The method is based on the use of acetonitrile as extraction solvent and on controlled adsorptive accumulation of the herbicide at the potential of 0.50 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 3.3). Soil sample extracts were analysed directly after drying and redissolution with the supporting electrolyte but without other pre-treatment. The limit of detection obtained for a 10 s collection time was 0.021 g g–1. Recovery experiments for the global procedure, at the 0.500 g g–1 level, gave satisfactory mean and standard deviation results which were comparable to those obtained by HPLC with UV detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号