共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Harir M Frommberger M Gaspar A Martens D Kettrup A El Azzouzi M Schmitt-Kopplin P 《Analytical and bioanalytical chemistry》2007,389(5):1459-1467
The photodecomposition of imazamox, a herbicide of the imidazolinone family, was investigated in pure water. The main photoproducts
from the photolysis were followed over time by liquid chromatography mass spectrometry and structures were proposed from exact
mass determinations obtained by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. The method
comprised exact mass determination with better than 0.2 ppm mass accuracy and a corresponding structural visualization taking
care of respective isotopes with an adapted van Krevelen diagram that enabled a systematic approach to the characterisation
of the elementary composition of each photoproduct. By taking advantage of the high resolving power of FT-ICR MS to make precise
formula assignments, the derived 2D van Krevelen diagram (O/C; H/C; m/z) enabled one to structurally differentiate the formed photoproducts and to propose a degradation pathway for imazamox.
Figure Overview of applied method to analyse the photolysis process of imazamox herbicide 相似文献
3.
E. van der Heeft Y. J. C. Bolck B. Beumer A. W. J. M. Nijrolder A. A. M. Stolker M. W. F. Nielen 《Journal of the American Society for Mass Spectrometry》2009,20(3):451-463
The applicability of ultra-performance liquid chromatography (UPLC) combined with full-scan accurate mass time-of-flight (TOF)
and Orbitrap mass spectrometry (MS) to the analysis of hormone and veterinary drug residues was evaluated. Extracts from blank
bovine hair were fortified with 14 steroid esters. UPLC-Orbitrap MS performed at a resolving power of 60,000 (FWHM) enabled
the detection and accurate mass measurement (<3 ppm error) of all 14 steroid esters at low ng/g concentration level, despite
the complex matrix background. A 5 ppm mass tolerance window proved to be essential to generate highly selective reconstructed
ion chromatograms (RICs) having reduced background from the hair matrix. UPLC-Orbitrap MS at a lower resolving power of 7500
and UPLC-TOFMS at mass resolving power 10,000 failed both to detect all of the steroid esters in hair extracts owing to the
inability to mass resolve analyte ions from co-eluting isobaric matrix compounds. In a second application, animal feed extracts
were fortified with coccidiostats drugs at levels ranging from 240 to 1900 ng/g. UPLC-Orbitrap MS conducted at a resolving
power of 7500 and 60,000 and UPLC-TOFMS detected all of the analytes at the lowest investigated level. Thanks to the higher
analyte-to-matrix background ratio, the utilization of very narrow mass tolerance windows in the RIC was not required. This
study demonstrates that even when the targeted sample preparation from conventional LC-MS/MS is applied to UPLC with full-scan
accurate mass MS, false compliant (false negative) results can be obtained when the mass resolving power of the MS is insufficient
to separate analyte ions from isobaric co-eluting sample matrix ions. The current trend towards more generic and less selective
sample preparation is expected to aggravate this issue further. 相似文献
4.
Stefanie M?dler 《Journal of the American Society for Mass Spectrometry》2001,12(3):243-244
Editorial
Focus on Fourier transform ion cyclotron resonance mass spectrometry 相似文献5.
Palmblad M Tsybin YO Ramström M Bergquist J Håkansson P 《Rapid communications in mass spectrometry : RCM》2002,16(10):988-992
Liquid separation methods in combination with electrospray mass spectrometry as well as the recently introduced fragmentation method electron capture dissociation (ECD) have become powerful tools in proteomics research. This paper presents the results of the first successful attempts to combine liquid chromatography (LC) and Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) with ECD in the analysis of a mixture of standard peptides and of a bovine serum albumin tryptic digest. A novel electron injection system provided conditions for ECD sufficient to yield extensive sequence information for the most abundant peptides in the mixtures on the time-scale of the chromatographic separation. The results suggest that LC/ECD-FTICRMS can be employed in the characterization of peptides in enzymatic digests of proteins or protein mixtures and identify and localize posttranslational modifications. 相似文献
6.
Fei Han Yan-ting Li Xin-juan Mao Xiao-shu Zhang Jiao Guan Ai-hua Song Ran Yin 《Analytical and bioanalytical chemistry》2016,408(7):1975-1981
7.
Hau J Stadler R Jenny TA Fay LB 《Rapid communications in mass spectrometry : RCM》2001,15(19):1840-1848
The interpretation of mass spectra is a key process during compound identification, and the combination of tandem mass spectrometry (MS/MS) with high-accuracy mass measurements may deliver crucial information on the identity of a compound. Obtaining accurate mass data of fragment ions in MS/MS reveals the particular problem of mass calibration when a lockmass, which is frequently used to obtain accurate masses in MS, is absent. An alternative technique is to recalibrate the MS/MS spectrum using a reference MS/MS spectrum acquired under the same conditions. We have tested and validated this approach using a hybrid quadrupole/orthogonal acceleration reflectron-type time-of-flight (TOF) mass spectrometer. The results were compared with those obtained under similar conditions on a Fourier transform ion cyclotron resonance (FT-ICR) instrument. We found that the mass accuracy observed with such an "external" recalibration on the TOF instrument in MS/MS is identical to what can be obtained on a similar instrument operating in one-dimensional MS mode using the lockmass technique. However, mass accuracy in both cases is one order of magnitude inferior to that obtained using FTMS, and also inferior to that observed using sector field MS when operated at comparable resolution. Nevertheless, for small (<200 Da) molecules, this mass accuracy was still sufficient to have the "true" elemental composition identified as the first hit in about 70% of all cases. It was possible to elucidate the fragmentation mechanism of eight azaheterocycles containing a pyridine moiety, where the accurate mass data from the TOF instrument allowed distinction between two alternative fragmentation pathways. 相似文献
8.
Palmblad M Bindschedler LV Gibson TM Cramer R 《Rapid communications in mass spectrometry : RCM》2006,20(20):3076-3080
Accurately measured peptide masses can be used for large-scale protein identification from bacterial whole-cell digests as an alternative to tandem mass spectrometry (MS/MS) provided mass measurement errors of a few parts-per-million (ppm) are obtained. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) routinely achieves such mass accuracy either with internal calibration or by regulating the charge in the analyzer cell. We have developed a novel and automated method for internal calibration of liquid chromatography (LC)/FTICR data from whole-cell digests using peptides in the sample identified by concurrent MS/MS together with ambient polydimethylcyclosiloxanes as internal calibrants in the mass spectra. The method reduced mass measurement error from 4.3 +/- 3.7 ppm to 0.3 +/- 2.3 ppm in an E. coli LC/FTICR dataset of 1000 MS and MS/MS spectra and is applicable to all analyses of complex protein digests by FTICRMS. 相似文献
9.
10.
Speir JP Perkins G Berg C Pullen F 《Rapid communications in mass spectrometry : RCM》2000,14(20):1937-1942
Fast gradient high performance liquid chromatography (HPLC) has been combined with a commercially available Fourier transform ion cyclotron resonance (FTICR) mass spectrometer for the routine and high performance analysis of mixtures. With this combination we were able to separate and detect, under high mass accuracy conditions, a six-component drug mixture in less than 5 minutes. The fast gradients described are now possible due to the development of mechanically robust, ultra pure silica packing materials, which allow relatively high flow rates (ca. 1 mL/min for a 2 mm diameter column). For the six compounds present in the model mixture, relative mass errors of less than 1 ppm were obtained (based on an external calibration) providing sufficient mass accuracy to make unequivocal assignments of empirical formulae. Preliminary results of fast gradient HPLC/FTICR-MS/MS are also shown for the same six-component mixture. Copyright 2000 John Wiley & Sons, Ltd. 相似文献
11.
Maria A. van Agthoven Marc-André Delsuc Geoffrey Bodenhausen Christian Rolando 《Analytical and bioanalytical chemistry》2013,405(1):51-61
Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) achieves high resolution and mass accuracy, allowing the identification of the raw chemical formulae of ions in complex samples. Using ion isolation and fragmentation (MS/MS), we can obtain more structural information, but MS/MS is time- and sample-consuming because each ion must be isolated before fragmentation. In 1987, Pfändler et al. proposed an experiment for 2D FT-ICR MS in order to fragment ions without isolating them and to visualize the fragmentations of complex samples in a single 2D mass spectrum, like 2D NMR spectroscopy. Because of limitations of electronics and computers, few studies have been conducted with this technique. The improvement of modern computers and the use of digital electronics for FT-ICR hardware now make it possible to acquire 2D mass spectra over a broad mass range. The original experiments used in-cell collision-induced dissociation, which caused a loss of resolution. Gas-free fragmentation modes such as infrared multiphoton dissociation and electron capture dissociation allow one to measure high-resolution 2D mass spectra. Consequently, there is renewed interest to develop 2D FT-ICR MS into an efficient analytical method. Improvements introduced in 2D NMR spectroscopy can also be transposed to 2D FT-ICR MS. We describe the history of 2D FT-ICR MS, introduce recent improvements, and present analytical applications to map the fragmentation of peptides. Finally, we provide a glossary which defines a few keywords for the 2D FT-ICR MS field. 相似文献
12.
Goodwin RJ Pitt AR Harrison D Weidt SK Langridge-Smith PR Barrett MP Logan Mackay C 《Rapid communications in mass spectrometry : RCM》2011,25(7):969-972
Mass spectrometry imaging (MSI) is a powerful tool in metabolomics and proteomics for the spatial localization and identification of pharmaceuticals, metabolites, lipids, peptides and proteins in biological tissues. However, sample preparation remains a crucial variable in obtaining the most accurate distributions. Common washing steps used to remove salts, and solvent-based matrix application, allow analyte spreading to occur. Solvent-free matrix applications can reduce this risk, but increase the possibility of ionisation bias due to matrix adhesion to tissue sections. We report here the use of matrix-free MSI using laser desorption ionisation performed on a 12 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. We used unprocessed tissue with no post-processing following thaw-mounting on matrix-assisted laser desorption ionisation (MALDI) indium-tin oxide (ITO) target plates. The identification and distribution of a range of phospholipids in mouse brain and kidney sections are presented and compared with previously published MALDI time-of-flight (TOF) MSI distributions. 相似文献
13.
石油是一种复杂体系,研究石油分子组成是分析化学领域的经典难题.近年来,傅里叶变换离子回旋共振质谱技术(Fourier transform ion cyclotron resonance mass spectrometry,FT-ICR MS)的发展,为从分子水平认识石油组成提供了机会,引起了石油化学界的高度关注,并被期待能在石油、石化领域的相关研究中实现重大突破.本文从质谱分辨率和电离技术方面介绍了石油样品的分析需求,总结了近几年基于FT-ICR MS技术对石油分子组成的研究进展,分析了其在应用中存在的关键技术问题及下一步研究方向,并对FT-ICR MS的发展前景给予展望. 相似文献
14.
Ivan A. Boldin Eugene N. Nikolaev 《Rapid communications in mass spectrometry : RCM》2009,23(19):3213-3219
Peak coalescence, i.e. the merging of two close peaks in a Fourier transform ion cyclotron resonance (FTICR) mass spectrum at a high number of ions, plays an important role in various FTICR experiments. In order to describe the coalescence phenomenon we would like to propose a new theory of motion for ion clouds with close mass‐to‐charge ratios, driven by a uniform magnetic field and Coulomb interactions between the clouds. We describe the motion of the ion clouds in terms of their averaged drift motion in crossed magnetic and electric fields. The ion clouds are considered to be of constant size and their motion is studied in two dimensions. The theory deals with the first‐order approximation of the equations of motion in relation to dm/m, where dm is the mass difference and m is the mass of a single ion. The analysis was done for an arbitrary inter‐cloud interaction potential, which makes it possible to analyze finite‐size ion clouds of any shape. The final analytical expression for the condition of the onset of coalescence is found for the case of uniformly charged spheres. An algorithm for finding this condition for an arbitrary interaction potential is proposed. The critical number of ions for the peak coalescence to take place is shown to depend quadratically on the magnetic field strength and to be proportional to the cyclotron radius and inversely proportional to the ion masses. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
15.
Lars Müller Marc‐Christopher Reinnig Heiko Hayen Thorsten Hoffmann 《Rapid communications in mass spectrometry : RCM》2009,23(7):971-979
The components of secondary organic aerosols (SOAs) generated from the gas‐phase ozonolysis of two C10H16‐terpenes (α‐pinene; sabinene) and a cyclic C6H10 alkene (cyclohexene) were characterized by the use of a Fourier transform ion cyclotron mass spectrometer equipped with an electrospray ionization source operated in the negative ion mode. Reversed‐phase high‐performance liquid chromatography was used to achieve chromatographic separation of highly oxidized organic compounds. In addition to the well‐known group of low molecular weight oxidation products (monomers; e.g. dicarboxylic acids), higher molecular weight compounds (dimers) were also detected and their exact elemental compositions were determined. In order to provide additional information for the structural elucidation of these compounds, collision‐induced dissociation was applied. Based on the MS/MS spectra, two higher molecular weight products are proposed to be an ester and a peroxide. Molecular formulae calculated from the exact masses show that the SOA‐compounds are heavily oxidized and this information creates the background to a discussion of potential reaction pathways for the formation of higher molecular weight compounds. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
16.
Fei Han Yan-ting Li Xin-juan Mao Xiao-shu Zhang Jiao Guan Ai-hua Song Ran Yin 《Analytical and bioanalytical chemistry》2016,408(7):1983-1983
17.
Greig MJ Bolaños B Quenzer T Bylund JM 《Rapid communications in mass spectrometry : RCM》2003,17(24):2763-2768
Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) was coupled with atmospheric pressure photoionization (APPI) for the first time and used for the analysis of several corticosteroids.1 The analytes showed excellent response using APPI when compared with both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). APPI has the advantage of requiring less heat for desolvation, resulting in less thermal degradation of the analytes and higher signal-to-noise than APCI. In terms of ultimate sensitivity, APPI is more efficient than either ESI or APCI for the analysis of corticosteroids. With some compounds, the high-resolution capability of FTICRMS was necessary to obtain an accurate mass due to contributions of the M(+.) (13)C isotope in the [M+H](+) ion peak. 相似文献
18.
19.
Leinweber FC Schmid DG Lubda D Wiesmüller KH Jung G Tallarek U 《Rapid communications in mass spectrometry : RCM》2003,17(11):1180-1188
Capillary liquid chromatography based on particulate and monolithic stationary phases was used to screen complex peptide libraries by fast gradient elution coupled on-line to electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS). A slightly modified commercial electrospray interface consisting of a fused-silica transfer capillary and low dead volume stainless steel union at which the electrospray voltage was grounded enabled the effluent of all the capillary columns to be directly sprayed into the mass spectrometer. Stable electrospray conditions were generated over a wide range of mobile phase compositions, alleviating the need for a tapered end of the spray capillary, pneumatic assistance or preheated nebulizer gas. Since the identification of complex samples containing numerous isobaric substances is facilitated by chromatographic separation prior to mass spectrometry, stationary phase materials have been employed which offer a fast, efficient elution and, due to the complexity of samples, a high loading capacity. Silica-based monolithic capillary columns combine these three characteristics in a unique manner due to a tailored adjustment of both macro- and mesopore sizes in the highly porous silica structure. As we demonstrate by a comparative study of the silica-based monolithic and packed capillaries for LC/MS analysis of complex peptide libraries, silica monoliths show superior performance over packed beds of small-diameter particles with respect to analysis time and separation efficiency. Libraries with more than 1000 different peptides could be screened in less than 20 min. 相似文献