首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An inexpensive and effective sample preparation procedure for the determination of three ethylphenolic off-flavours (4-ethylphenol, 4-ethylguaiacol and 4-ethylcathecol) in wine samples is presented. Analytes were in situ acetylated and concentrated using a disposable silicone sorbent (DSS) exposed to the diluted sample. After that, the analytes were recovered with ethyl acetate and determined by gas chromatography with mass spectrometry. The influence of different parameters (volume of acetic anhydride, basic catalyst, ionic strength, sorbent format, sampling mode and extraction time) on the efficiency of derivatization and extraction steps is discussed. Under optimized conditions, 2 mL of wine were diluted with 15 mL of an aqueous solution of potassium bicarbonate (5%, m/v) in a 22 mL vessel, containing 2 g of sodium chloride. The volume of acetic anhydride and the extraction time were set at 90 μL and 2 h, and the extraction was carried out at room temperature (20±2°C). Analytes were concentrated using a silicone disc (5 mm diameter × 0.5 mm thickness) and further desorbed with 0.2 mL of ethyl acetate. The achieved limits of quantification (LOQs), defined as the concentration of each compound providing a signal 10 times higher than the baseline noise, stayed between 5 and 15 ng mL(-1). The method provided a linear response range of up to 5000 ng mL(-1) and relative recoveries from 91% to 116%. The 4-ethylphenol off-flavour was detected in most red wine samples at concentrations of up to 2700 ng mL(-1).  相似文献   

2.
Steroid determination by immunoassays results in significant interferences and inaccurate results. This study describes the development and validation of a new gas chromatographic-mass spectrometric method for the simultaneous quantification of 17alpha-hydroxyprogesterone (17alphaOHP), testosterone (T), dehydroepiandrosterone (DHEA), androstenedione (Delta4-A), cortisol (F) and pregnenolone (Preg) in serum of neonates. Steroids were extracted and purified from 0.5 mL serum using diethyl ether and Extrelut mini NT1 column. The extracts were derivatized with N-methyl-N-trimethylsilyl-trifluoroacetamide (MSTFA)/trimethylsilyl iodide (TMSI)/dithioerythritol (DTE) and the resulting trimethylsilyl derivatives were quantified by gas chromatography-selected ion monitoring-mass spectrometry (GC-SIM-MS). The detection limit for all steroids was lower than 0.1 ng/mL. The limit of quantification was 0.1 ng/mL for all steroids except cortisol which was at 0.25 ng/mL. d3-Testosterone and methyltestosterone served as internal standards. Precision for all compounds at the concentrations of 0.5, 1, 5 and 10 ng/mL (n = 10) in fortified steroid-free serum samples ranged from 0.8% to 16.6%. Accuracy was calculated at the concentrations of 0.5, 1, 5 and 10 ng/mL and ranged from -9.2% to 10.6% (n = 10). Linear calibration equations were obtained for all five steroids (0.125-31.25 ng/mL) and for cortisol (0.125-200 ng/mL). Relative recoveries at concentrations 1.0 and 12.5 ng/mL ranged from 70.5% to 97.5%. Absolute recoveries at the same concentrations ranged from 73.2% to 96.6%. Reference intervals were estimated for infants aged from 9 to 40 days. The proposed steroid profile is suitable for routine analysis and provides meaningful data for samples within normal range as well as those with elevated levels.  相似文献   

3.
A rapid analytical method for the multiresidue determination of several organochlorine and organophosphorus pesticides and polychlorinated biphenyls in human serum samples has been developed. Analytes were isolated by solid-phase extraction using C18 cartridges with subsequent analysis by GC-MS/MS using a glass liner packed with CarboFrit in the GC injection port. Labelled surrogate internal standards (fenitrothion D6, HCB (13)C6, p, p'-DDE D8 and PCB 138 (13)C12) were added to the samples before the extraction and were used for quantitation and for quality control in the analysis of real-world samples. Accuracy and precision were evaluated by using serum samples fortified at two concentration levels for the three families of compounds, with satisfactory results in the majority of cases. The high selectivity and sensitivity of GC-MS/MS allowed low detection limits of 0.05-0.5 ng mL(-1) for most of the analytes investigated. The developed procedure improves other current methodologies for the analysis of pesticides and PCBs in biological fluids, especially as regards to analysis time and simplicity of sample treatment. The method was applied to several serum samples obtained from farmers devoted to citrus crop production. Chlorpyrifos, HCB, p, p'-DDE and the higher chlorinated PCBs (153, 138 and 180) were the most frequently detected compounds.  相似文献   

4.
A new gas chromatographic-tandem mass spectrometric method has been developed and validated for the determination of two N-methylcarbamates, carbofuran and carbaryl and their metabolites in applicators' urine specimens. Mild conditions were used for sample preparation based on enzymic hydrolysis and solid-phase extraction using Oasis HLB sorbent cartridges. Amides, phenols and ketones were first converted to volatile derivatives of trifluoroacetic acid anhydride (TFAA) and afterwards were quantitated using tandem mass spectrometry. Linear calibration equations (1-200 ng mL(-1) urine) were obtained from fortified urine samples for all eight compounds, carbaryl, 1-naphthol, 2-naphthol, and carbofuran, 3-hydroxycarbofuran, 7-phenol, carbofuran-3-keto, 3- hydroxycarbofuranphenol. For all compounds, the limit of detection was lower than 0.1 ng mL(-1). Precision for all compounds, at the concentrations of 1, 10 and 100 ng mL(-1) (n = 5) in-fortified urine samples ranged from 0.7% to 18%. Accuracy was calculated at two concentrations 8 and 80 ng mL(-1) (n = 5) and ranged from -8.4% to 8.2%. Relative recoveries at concentrations of 1, 10 and 100 ng mL(-1), ranged from 71% to 116%. The method was successfully applied to five male applicators and 10 non-applicators (including both smokers and non-smokers).  相似文献   

5.
A sensitive and specific method was developed and validated for the determination of mitiglinide in human plasma using liquid chromatographic separation with electrospray ionization tandem mass spectrometric detection. Acidified plasma samples were extracted with ethyl acetate. The chromatographic separation was performed on an Agilent Zorbax Eclipse Plus C(18) column with a mobile phase of methanol-10 mm ammonium acetate solution at a flow rate of 0.3 mL/min. Analytes were detected with an Agilent 6410 Triple qudrupole mass spectrometer equipped with an electrospray ionization source in positive multiple reaction monitoring mode: m/z 316.2 (precursor ion) to 298.2 (product ion) for mitiglinide and m/z 318.2 (precursor ion) to 120.2 (product ion) for the internal standard. This method was validated over a linear range of 0.5-4000 ng/mL for mitiglinide in human plasma. The lower limit of quantification (LLOQ) was 0.5 ng/mL, while a relative standard deviation (RSD) was less than 3.9%. The intra- and inter-run precision (as RSD, %) obtained from three validation runs were all less than 15%. The validated method was successfully used to analyze human plasma samples for application in pharmacokinetic studies.  相似文献   

6.
An improved method for the determination of triclosan (TCS) and methyltriclosan (MTCS) in fish and foodstuff samples is presented. Analytes were simultaneously extracted and purified using the matrix solid-phase dispersion (MSPD) technique, and then selectively determined by gas chromatography with tandem mass spectrometry (GC-MS/MS). Several combinations of dispersants, clean-up co-sorbents and extraction solvents were tested in order to obtain lipid-free extracts and quantitative recoveries for TCS and MTCS. Under optimised conditions, 0.5 g samples were dispersed using 1.5 g of neutral silica in a mortar with a pestle, and transferred to a polypropylene cartridge containing 3 g of silica impregnated with 10% of sulphuric acid (SiO2-H2SO4, 10%, w/w). Analytes were recovered with 10 mL of dichloromethane whereas lipids were oxidized in the layer of acidic silica. The extract was concentrated to dryness and re-constituted with 1 mL of ethyl acetate. Then, a fraction of 0.5 mL was mixed with 50 microL of N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) and injected in the GC-MS/MS system. The developed method provided absolute recoveries between 77 and 120% for different samples spiked at the low ng g(-1) level, quantification limits in the range of 1-2 ng g(-1) and a considerable simplicity in comparison with previously developed sample preparation approaches. Experiments carried out placing sliced food samples in direct contact with TCS-treated kitchenware surfaces showed the capability of the biocide to migrate into foodstuffs.  相似文献   

7.
A trace analytical method based on high performance liquid chromatography coupled to quadrupole time-of-flight high resolution mass spectrometry was developed for simultaneous determination of perfluoroalkyl phosphonates (PFPAs, carbon chain lengths C6,8,10), perfluoroalkyl carboxylates (PFCAs, C5-12), and perfluoroalkyl sulfonates (PFSAs, C4,6,8,10) in drinking water (tap water). Analytes were enriched on a mixed mode co-polymeric sorbent (C8+quaternary amine) using solid phase extraction. Chromatographic separation was achieved on a Zorbax Extend C18 reversed phase column using a mobile phase gradient consisting of water, methanol, and acetonitrile containing 2mM ammonium acetate and 5 mM 1-methyl piperidine. The mass spectrometer was operated in electrospray negative ion mode. Use of 1-methyl piperidine in the mobile phase resulted in a significant increase in instrument sensitivity for PFPAs through improved chromatographic resolution, background suppression, and increased ionization efficiency. Method detection limits for extraction of 500 mL tap water were in the ranges of 0.095-0.17 ng/L, 0.027-0.17 ng/L, and 0.014-0.052 ng/L for PFPAs, PFCAs, and PFSAs, respectively. Whole method recoveries at a spiking level of 0.5 ng/L to 500 mL HPLC grade water were 40-56%, 56-97%, and 55-77% for PFPAs, PFCAs, and PFSAs, respectively. A matrix effect (signal enhancement) was observed in the detection of PFPAs in tap water extracts, leading to calculated recoveries of 249-297% at a 0.5 ng/L spiking level. This effect resulted in an additional improvement of method sensitivity for PFPAs. To compensate for the matrix effect, PFPAs in tap water were quantified using matrix-matched and extracted calibration standards. The method was successfully applied to the analysis of drinking water collected from six European countries. PFPAs were not detected except for perfluorooctyl phosphonate (PFOPA) at close to the detection limit of 0.095 ng/L in two water samples from Amsterdam, the Netherlands. Highest levels were found for perfluorobutane sulfonate (PFBS, 18.8 ng/L) and perfluorooctanoate (PFOA, 8.6 ng/L) in samples from Amsterdam as well as for perfluorooctane sulfonate (PFOS, 8.8 ng/L) in tap water from Stockholm, Sweden.  相似文献   

8.
A rapid, simple, sensitive and specific LC‐MS/MS method has been developed and validated for the simultaneous estimation of atorvastatin (ATO), amlodipine (AML), ramipril (RAM) and benazepril (BEN) using nevirapine as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple‐reaction monitoring mode using electrospray ionization. Analytes and IS were extracted from plasma by simple liquid–liquid extraction technique using ethyl acetate. The reconstituted samples were chromatographed on C18 column by pumping 0.1% formic acid–acetonitrile (15:85, v/v) at a flow rate of 1 mL/min. A detailed validation of the method was performed as per the FDA guidelines and the standard curves were found to be linear in the range of 0.26–210 ng/mL for ATO; 0.05–20.5 ng/mL for AML; 0.25–208 ng/mL for RAM and 0.74–607 ng/mL for BEN with mean correlation coefficient of ≥0.99 for each analyte. The intra‐day and inter‐day precision and accuracy results were well with in the acceptable limits. A run time of 2.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The developed assay method was successfully applied to a pharmacokinetic study in human male volunteers. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
A liquid chromatography/mass spectrometry method for simultaneous determination of paracetamol and dextropropoxyphene in human plasma is described. Paracetamol and dextropropoxyphene, together with their internal standards (tolbutamide and pyrroliphene), were extracted from 0.5 mL of plasma using solid-phase extraction. The chromatography was performed using a Thermo Hypersil APS-2 Amino column (250 mm x 4.6 mm, 5 microm) with a mobile phase consisting of acetonitrile and 0.4% glacial acetic acid in water (20:80). The total run time was 6 min for each sample. The triple-quadrupole mass spectrometer was operated in both positive (for detection of dextropropoxyphene and its IS pyrroliphene) and negative (for detection of paracetamol and its IS tolbutamide) modes using a polarity-switching technique. Multiple reaction monitoring was used for quantification. The method was linear over the concentration range of 0.1-20 microg/mL for paracetamol and 0.5-80 ng/mL for dextropropoxyphene. The intra- and inter-day precision were less than 10%, and the accuracy ranged from 92.2-110.9%. The lower limits of quantification were 0.1 microg/mL for paracetamol and 0.5 ng/mL for dextropropoxyphene. The present method provides a robust, fast and sensitive analytical tool for both paracetamol and dextropropoxyphene, and has been successfully applied to a clinical bioequivalence study in 14 subjects.  相似文献   

10.
A simple and sensitive GC-EI-MS method using solvent extraction and evaporation was developed for the determination of olanzapine concentrations in plasma samples. Because olanzapine and promazine, which was used as the internal standard (IS), are nitrogenous bases, they can adsorb to the weakly acidic silanol groups on the surfaces of glass centrifuge tubes during solvent extraction and evaporation. Silylation of the glass tubes, addition of triethylamine (TEA), and use of a sample solution with a basic pH could prevent adsorption loss. The extraction method involved mixing plasma (500 μL) in a silylated glass tube with a promazine solution (2 μg/mL, 25 μL) in methanol containing 1% TEA. After addition of aqueous sodium carbonate (0.5 mol/L, pH 11.1, 1 mL) and extraction into 3 mL of dichloromethane/n-hexane (1:1, v/v) containing 1% TEA, the organic phase was evaporated to dryness in a silylated glass tube. The residue was dissolved in ethyl acetate containing 1% TEA (50 μL). For GC-EI-MS analysis, the calibration curves of olanzapine in human plasma were linear from 0.5 to 100 ng/mL. Intra- and interday precisions in plasma were both less than 7.36% (coefficient of variation), and the accuracy was between 94.6 and 110% for solutions with concentrations greater than 0.5 ng/mL. The limit of quantification was 0.5 ng/mL in plasma. The assay was applied to therapeutic drug monitoring in samples from three schizophrenic patients.  相似文献   

11.
A rapid and sensitive reversed-phase high performance liquid chromatographic method has been developed for the determination of metoclopramide in serum. The assay was performed after single extraction with ethyl ether using methyl parahydroxybenzoate as internal standard. Chromatographic separations were performed on C(18) stationary phase with a mobile phase composed of methanol-phosphate buffer pH 3 (30:70 v/v). Analytes were detected electrochemically. The quantification limit for metoclopramide in serum was 2 ng mL(-1). Linearity of the method was confirmed in the range of 5-120 ng mL(-1) (correlation coefficient 0.9998). Within-day relative standard deviations (RSDs) ranged from 0.3 to 5.5% and between-day RSDs from 0.8 to 6.0%. The analytical method was successfully applied for the determination of pharmacokinetic parameters after ingestion of 10 mg dose of metoclopramide. Studies were performed on 18 healthy volunteers of both sexes.  相似文献   

12.
A simple, rapid and sensitive LC‐UV method was developed and validated for the determination of paclitaxel (PTX) in rabbit plasma and tissues. A 2 mL aliquot of acetonitrile and 10 μL ammonium acetate (pH 5.0, 6 m ) as extraction agents were used to markedly increase the extraction recoveries and greatly reduce the endogenous substances. The separation was achieved on a C18 column at 30 °C using an acetonitrile–ammonium acetate buffer (pH 5.0, 0.02 m ; 55:45, v/v) at a flow rate of 1.0 mL/min; UV detection was used at 227 nm. Good linearity was obtained between 0.025 and 10,000 µg/mL for plasma and between 0.025–200,000 µg/g for tissue samples (r > 0.999). The limit of detection was 6 ng/mL in plasma, 8 ng/g in heart and 12.5 ng/g in other tissues. The limit of quantitation was 25 ng/mL in plasma and heart, 125 ng/g in other tissues. The intra‐ and inter‐day assays of precision and accuracy for all bio‐samples ranged from 1.38 to 9.60% and from 83.6 to 114.5%, respectively. The extraction recoveries ranged from 70.1 to 109.5%. Samples were stable during three freeze–thaw cycles or stored in a freezer at ?20 °C for 30 days. The assay method was successfully applied to a study of the pharmacokinetics and tissue distribution of novel PTX lung targeting liposomes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
A method for the determination of trace amounts of off-flavor compounds including 2-methylisoborneol, geosmin and 2,4,6-trichloroanisole in drinking water was developed using the stir bar sorptive extraction technique followed by thermal desorption-GC-MS analysis. The extraction conditions such as extraction mode, salt addition, extraction temperature, sample volume and extraction time were examined. Water samples (20, 40 and 60 ml) were extracted for 60-240 min at room temperature (25 degrees C) using stir bars with a length of 10 mm and coated with a 500 microm layer of polydimethylsiloxane. The extract was analyzed by thermal desorption-GC-MS in the selected ion monitoring mode. The method showed good linearity over the concentration range from 0.1 or 0.2 or 0.5 to 100 ng l(-1) for all the target analytes, and the correlation coefficients were greater than 0.9987. The detection limits ranged from 0.022 to 0.16 ng l(-1). The recoveries (89-109%) and precision (RSD: 0.80-3.7%) of the method were examined by analyzing raw water and tap water samples fortified at the 1 ng l(-1) level. The method was successfully applied to low-level samples (raw water and tap water).  相似文献   

14.
A highly sensitive and selective ultra‐performance liquid chromatography–tandem mass spectrometry method is described for the simultaneous determination of nomegestrol acetate (NOMAC), a highly selective progestogen, and estradiol (E2), a natural estrogen in human plasma. NOMAC was obtained from plasma by solid‐phase extraction, while E2 was first separated by liquid–liquid extraction with methyl tert‐butyl ether followed by derivatization with dansyl chloride. Deuterated internal standards, NOMAC‐d5 and E2‐d4 were used for better control of extraction conditions and ionization efficiency. The assay recovery of the analytes was within 90–99%. The analytes were separated on UPLC BEH C18 (50 × 2.1 mm, 1.7 μm) column using a mobile phase comprising of acetonitrile and 3.0 mm ammonium trifluoroacetate in water (80:20, v/v) with a resolution factor (Rs) of 3.21. The calibration curves were linear from 0.01 to 10.0 ng/mL for NOMAC and from 1.00 to 1000 pg/mL for E2, respectively. The intra‐ and inter‐batch precision was ≤5.8% and the accuracy of quality control samples ranged from 96.7 to 103.4% for both analytes. The practical applicability of the method is demonstrated by analyzing samples from 18 healthy postmenopausal women after oral administration of 2.5 mg nomegestrol acetate and 1.5 mg estradiol film‐coated tablets under fasting.  相似文献   

15.
A liquid chromatographic-mass spectrometry (LC/MS) assay method was developed for the determination of amiodarone and desethylamiodarone in rat specimens. Analytes were extracted using liquid-liquid extraction in hexane. The LC/MS system consisted of a Waters Micromass ZQtrade mark 4000 spectrometer with an autosampler and pump. A C(18) 3.5 microm (2.1 x 50 mm) column heated to 45 degrees C was used for separation. The mobile phase consisted of methanol and 0.2% aqueous formic acid pumped at 0.2 mL/min as a linear gradient. Components eluted within 12 min. The concentrations of ethopropazine (internal standard), desethylamiodarone and amiodarone were monitored for m/z of 313.10, combination of 546.9 and 617.73, and 645.83, respectively. In plasma (0.1 mL), linearity was achieved between the peak area ratios and concentrations over the range of 2.5-1000 ng/mL for both amiodarone and desethylamiodarone (r(2) > 0.999). The intraday and interday CV were equal or less than 18%, and mean error was <12%. Similarly, in homogenates containing 0.1 g of rat tissue, linearity was observed in standards ranging from 5 to 5000 ng/g. The method was successfully used to measure tissue and plasma concentrations of drug. The validated lower limit of quantitation was 2.5 ng/mL for drug and metabolite, based on 0.1 mL of plasma.  相似文献   

16.
A low solvent consumption method for the determination of eight ultraviolet (UV) filters, displaying low to medium polarities, in freeze-dried samples of marine bivalves and fish is proposed. Matrix solid-phase dispersion (MSPD) and gas chromatography with mass spectrometry (GC-MS) were used as sample preparation and determination techniques, respectively. This work describes the influence of several parameters (type and amount of dispersant and clean-up sorbents, as well as elution solvent) on the yield and the selectivity of the MSPD extraction. Under optimized conditions, samples (0.5?g) were ground with 2?g of Florisil in a mortar with a pestle and transferred into a polypropylene syringe, which contained 1?g of C18 as clean-up sorbent. Analytes were eluted with 5?mL of acetonitrile. This extract was concentrated to dryness, re-constituted with 1?mL of ethyl acetate and injected in the GC-MS system without any further clean-up. The global average recoveries, measured for three different biota samples, spiked at three different levels (between 50 and 1000?ng?g?1), ranged from 80% to 101% with associated standard deviations below 10%. The inter-day precision of the method varied from 4% to 15% and the achieved LOQs (defined for a signal to noise ratio of 10) ranged from 4 to 28?ng?g?1, referred to the freeze-dried matrix. Octocrylene (OCR) was found in some samples of fish and mussels at concentrations between 15 and 20?ng?g?1, referred to dry mass.  相似文献   

17.
A simple and effective extraction method based on matrix solid-phase dispersion (MSPD) was developed to determine dimethoate, malathion, lufenuron, carbofuran, 3-hydroxycarbofuran, thiabendazole, difenoconazole and trichlorfon in coconut pulp using gas chromatography-mass spectrometry with selected ion monitoring (GC/MS, SIM). Different parameters of the method were evaluated, such as type of solid-phase (C(18), alumina, silica-gel and Florisil), the amount of solid-phase and eluent (dichloromethane, acetone, ethyl acetate, acetonitrile, n-hexane and n-hexane:ethyl acetate (1:1, v/v)). The best results were obtained using 0.5 g of coconut pulp, 1.0 g of C(18) as dispersant sorbent, 1.0 g of Florisil as clean-up sorbent and acetonitrile saturated with n-hexane as eluting solvent. The method was validated using coconut pulp samples fortified with pesticides at different concentration levels (0.25-1.0 mg kg(-1)). Average recoveries (four replicates) ranged from 70.1% to 98.7%, with relative standard deviations between 2.7% and 14.7%, except for lufenuron and difenoconazole, for which recoveries were 47.2% and 48.2%, respectively. Detection and quantification limits for coconut pulp ranged from 0.02 to 0.17 mg kg(-1) and from 0.15 to 0.25 mg kg(-1), respectively.  相似文献   

18.
A simplified sample preparation method, based on the matrix solid-phase dispersion technique, is proposed for the sensitive determination of 15 organic fungicides in vineyard soils by gas chromatography-mass spectrometry (GC-MS). Under final working conditions, sieved samples (0.5 g) were blended and dispersed with 2 g of C18 and transferred to a polypropylene syringe containing 1 g of diatomaceous earth. Analytes were recovered using 10 mL of ethyl acetate, this extract was concentrated to 1 mL and fungicides determined by GC-MS, without additional cleanup. The method provided recoveries in the range from 74 to 122% for soils with total carbon contents up to 5.5% and it allowed the use of external standard as quantification technique. Inter-day precision, given as relative standard deviations, stayed between 3 and 13%, and the limits of quantification were comprised between 0.6 and 15 ng g(-1). Several fungicides were found in the top layer of vineyard soils with the highest detection frequency and maximum concentration corresponding to iprovalicarb. Some real samples were also submitted to pressurized liquid extraction. Measured concentrations were in excellent agreement with those obtained by matrix solid-phase dispersion, which reinforces the accuracy of the latter methodology.  相似文献   

19.
A method using liquid chromatography-tandem mass spectrometry has been developed for determination of trace levels of tetracycline antibiotics in ground water and confined animal feeding operation waste water. Oxytetracycline (OTC), tetracycline (TC), and chlortetracycline (CTC) were extracted from water samples using both polymeric and C18 extraction cartridges. The addition of a buffer containing potassium phosphate and citric acid improved tetracycline recoveries in lagoon water. Method detection limits determined in reagent water fortified with 1 microg l(-1) OTC, TC, and CTC were 0.21, 0.20, and 0.28 microg l(-1). Method detection limits in lagoon water samples fortified at 20 microg l(-1) for OTC, TC, and CTC were 3.6, 3.1, and 3.8 microg l(-1). Variability in recovery from laboratory fortified blanks ranged from 86 to 110% during routine analysis.  相似文献   

20.
建立了同时测定牛奶中克伦特罗、氯霉素和己烯雌酚残留量的同位素稀释超高效液相色谱-串联质谱(UPLC-MS/MS)分析方法.牛奶样品无需蛋白沉淀,直接经HLB小柱净化及水和正己烷淋洗,由乙酸乙酯洗脱后进行分析.采用Acquity UPLC(○R)BEH C18色谱柱进行分离,以乙酸铵溶液-乙腈作为流动相进行梯度洗脱,MR...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号