首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The procedure for calculating linear temperature programmed indices as described in part 1 has been evaluated using five different nonpolar columns, with OV-1 as the stationary phase. For fourty-three different solutes covering five different classes of components, including n-alkanes and alkyl-aromatic compounds, both isothermal and temperature programmed indices were determined. The isothermal information was used to calculate temperature programmed indices. For several linear programmed conditions accuracies better than 0.51T-units were usually obtained. The results are compared with published procedures. It is demonstrated that isothermal retention information obtained on one column can be transferred to another column with the same stationary phase but different column dimensions and/or phase ratio. The temperature programmed indices calculated in this way also have an accuracy better than 0.51T-u. The temperature accuracy and precision of the GC-instrumentation used was of the order of 0.1°C. All calculations can be run with a Basic-programmed microcomputer.  相似文献   

2.
Direct conversion of isothermal to temperature programmed indices is not possible. In this work it is shown that linear temperature programmed retention indices can only be calculated from isothermal retention data if the temperature dependence of both the distribution coefficients and the column dead time are taken into account. Procedures are described which allow calculation of retention temperatures and from these, accurate programmed retention indices. Within certain limits the initial oven temperature and programming rate can be chosen freely. The prerequisite for this calculation is the availability of reliable isothermal retention data (retention times, retention factors, relative retention times, or retention indices) at two different temperatures for one column. The use of compiled isothermal retention indices at two different temperatures for the calculation of retention temperatures and thus temperature programmed indices is demonstrated. For the column for which programmed retention indices have to be determined, the isothermal retention times of the n-alkanes and the column dead time as a function of temperature have to be known in addition to the compiled data for a given stationary phase. Once the programmed retention indices have been calculated for a given column the concept allows the calculation of temperature programmed indices for columns with different specifications. The characteristics which can be varied are: column length, column inner diameter, phase-ratio, initial oven temperature, and programming rate.  相似文献   

3.
Conversion of Kováts retention indices on a given stationary phase into the thermodynamic parameters of compounds on a given column leads to a simplified method for retention simulation in isothermal, linear, and multi-ramp temperature programmed capillary gas chromatography. The influence of numerical methods used in the computation, the temperature coefficient of Kováts indices, and the experimental factors such as isothermal temperatures selected in the measurement of n-alkanes, column characterization and sample overloading, on the reproducibility and accuracy of simulation were discussed and examined. When the column used is properly characterized, the error between the simulated values and the experimental data is within ± 0.5 index unit or less than ± 1% of retention time.  相似文献   

4.
The scope of the principal techniques employed for the analysis of hydrocarbon mixtures is discussed, with emphasis on the analysis of one and two ring aromatic compounds by single column capillary gas chromatography. The paper considers both the column and the selection of the temperature regime (isothermal and temperature programmed). Much space is devoted to the characterization of the compounds by means of retention data.  相似文献   

5.
The retention times of selected compounds in temperature programmed gas chromatography were predicted using a two-parameter model, on the basis of thermodynamic data obtained from isothermal runs on seven capillary columns, primarily substituted with 5% diphenylsiloxane. The scope for using thermodynamic data obtained from isothermal runs on one column to optimize separation on a different column or a different instrument setup was investigated. Additionally, the predictive utility of thermodynamic data obtained using a DB-5 column that had been in use for three years was compared to that of a new column of the same model. It was found that satisfactory separation could be achieved on one capillary column or instrument setup on the basis of thermodynamic data obtained using a different column or instrument set-up.  相似文献   

6.
A live retention database for compound identification in isothermal and any step temperature programmed capillary gas chromatography has been developed. The database utilizes the Kovats retention indices of compounds on a given stationary phase and the retention time of n-alkanes measured at isothermal conditions on the column to be used, together with the programming parameters. Identification is performed by search operation that compares the calculated results with the retention values of unknown peaks. Cross-reference of the search results of different operating conditions is performed automatically by the database in order to increase the reliability of the identification. The error of the database conversion is ≤± 0.5 index unit, or ≤± 1% on retention time. This paper describes the principle and the structure of the database in detail. The experimental results for different calsses of compounds tested at divers operating conditions will be presented in Part Ⅱ.  相似文献   

7.
A definition for an absolute retention index is given. This index is independent of whether the process is isothermal or temperature programmed. The relation between this index and Kovats's index is discussed. General equations are derived for the retention times of homologous series, from which the position of the air peak or missing members can be determined. Methods used in the literature for air peak determination are improved and extended to other cases of interest. The retention index in temperature programmed chromatography is reexamined in the light of recent publications on temperature programming.  相似文献   

8.
A method was developed to calculate the second dimension retention index of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC/TOF-MS) data using n-alkanes as reference compounds. The retention times of the C(7)-C(31) alkanes acquired during 24 isothermal experiments cover the 0-6s retention time area in the second dimension retention time space, which makes it possible to calculate the retention indices of target compounds from the corresponding retention time values without the extension of the retention space of the reference compounds. An empirical function was proposed to show the relationship among the second dimension retention time, the temperature of the second dimension column, and the carbon number of the n-alkanes. The proposed function is able to extend the second dimension retention time beyond the reference n-alkanes by increasing the carbon number. The extension of carbon numbers in reference n-alkanes up to two more carbon atoms introduces <10 retention index units (iu) of deviation. The effectiveness of using the proposed method was demonstrated by analyzing a mixture of compound standards in temperature programmed experiments using 6 different initial column temperatures. The standard deviation of the calculated retention index values of the compound standards fluctuated from 1 to 12 iu with a mean standard deviation of 5 iu.  相似文献   

9.
A systematic approach was utilized to deduce the relation between the programmed and isothermal retention indices in chromatography. The relation was given in the form of a chart from which the equivalent isothermal temperature Te is plotted vs ΔT′ with IP as the parameter. ΔT′ is a function of both the inlet and outlet temperatures during the temperature programmed run and Te is the temperature at which the isothermal index is equal to the programmed index IP.  相似文献   

10.
Retention times in linear temperature programmed gas chromatography on narrow bore and megabore capillary columns have been calculated from experimental retention times measured at three isothermal temperatures: an iterative procedure performed by BASIC programs was used to obtain the values of the constants enabling the calculation of the programmed temperature retention times. Different methods of calculation have been compared.  相似文献   

11.
A method for the prediction of the retention time and the resolution of chromatographic peaks in different experimental conditions by starting from few experimental data measured in isothermal and isobaric analyses was published previously. In this paper, the same mathematical model was implemented for calculating the retention times and the column efficiency in programmed pressure runs. Some models originated from the Golay equation and reported in the literature are compared, and a new modified equation for the calculation of the peak width at half height is proposed. The procedure for the prediction of the retention time and the peak width at half height at programmed pressure of the carrier gas and different column temperature and linear gradient by using retention data of different compounds obtained in few isobaric runs is described. The prediction of the retention time and the separation efficiency of compounds with different polarity gave good results for the programmed pressure runs with linear gradient. The effect of the variation of the initial parameters of the experimental analyses and of the mathematical model on the accuracy of the prediction has been evaluated.  相似文献   

12.
Systems formed by serial connection of capillary columns of different polarity were studied with methods previously used to predict the behavior of linked capillary columns under isothermal conditions and to obtain programmed temperature gas chromatography (PTGC) retention times of the individual columns starting from isothermal data. The two calculation methods were simultaneously applied in order to predict PTGC retention times of the series system starting from isothermal data obtained on the two individual columns. Experimental retention values measured using different temperature programs on the individual columns and on the series systems were found to agree with those calculated.  相似文献   

13.
In this work, the effect of temperature in isothermal and programmed modes on several chromatographic parameters such as retention factor, selectivity, resolution and plate number has been discussed. A critical comparison of isocratic/isothermal, gradient/isothermal and isocratic/program temperature modes has been made. Two representative families of pesticides have been selected for this study. One includes ionisable chlorophenoxy acids and two of their esters, some of which show similar polarities. The other one contains several weakly polar carbamates. Analysis was carried out using a reversed-phase capillary high-performance liquid chromatography (HPLC) system and focusing technique with UV or diode array detection (DAD).  相似文献   

14.
The efficiency of capillary columns in programmed temperature analysis can be evaluated by calculation of the separation number (“Trennzahl”). A procedure for the prediction of this parameter at various initial temperatures, carrier gas pressures and heating rates, by using as the starting data the retention times and the peak widths obtained in some isobaric and isothermal runs is described. An equation is proposed that permits to obtain the values of the peak width at half height in any isothermal and linearly programmed temperature gas chromatographic run and therefore to calculate the separation number value. The effect on this parameter of the column polarity was investigated by using polar and non-polar compounds (n-alkanes and 1-alcohols).  相似文献   

15.
A correlation was established between the absolute and relative retention parameters of various compounds under different conditions of chromatographic analysis (isothermal and temperature programming conditions in gas chromatography or isocratic and gradient elution in high-performance liquid chromatography). This correlation is described by the linear regression equations t R (II) = = at R (I) + b with a high degree of accuracy. This property of chromatographic retention parameters allowed us not only to recalculate the values of these parameters determined under different conditions, but also to propose an algorithm for the simultaneous identification of a few components in complex mixtures with the use of published data on retention parameters found under other conditions (even presented as the drawings of chromatograms).  相似文献   

16.
In the present work it is shown that the linear elution strength (LES) model which was adapted from temperature-programming gas chromatography (GC) can also be employed to predict retention times for segmented-temperature gradients based on temperature-gradient input data in liquid chromatography (LC) with high accuracy. The LES model assumes that retention times for isothermal separations can be predicted based on two temperature gradients and is employed to calculate the retention factor of an analyte when changing the start temperature of the temperature gradient. In this study it was investigated whether this approach can also be employed in LC. It was shown that this approximation cannot be transferred to temperature-programmed LC where a temperature range from 60°C up to 180°C is investigated. Major relative errors up to 169.6% were observed for isothermal retention factor predictions. In order to predict retention times for temperature gradients with different start temperatures in LC, another relationship is required to describe the influence of temperature on retention. Therefore, retention times for isothermal separations based on isothermal input runs were predicted using a plot of the natural logarithm of the retention factor vs. the inverse temperature and a plot of the natural logarithm of the retention factor vs. temperature. It could be shown that a plot of lnk vs. T yields more reliable isothermal/isocratic retention time predictions than a plot of lnk vs. 1/T which is usually employed. Hence, in order to predict retention times for temperature-gradients with different start temperatures in LC, two temperature gradient and two isothermal measurements have been employed. In this case, retention times can be predicted with a maximal relative error of 5.5% (average relative error: 2.9%). In comparison, if the start temperature of the simulated temperature gradient is equal to the start temperature of the input data, only two temperature-gradient measurements are required. Under these conditions, retention times can be predicted with a maximal relative error of 4.3% (average relative error: 2.2%). As an example, the systematic method development for an isothermal as well as a temperature gradient separation of selected sulfonamides by means of the adapted LES model is demonstrated using a pure water mobile phase. Both methods are compared and it is shown that the temperature-gradient separation provides some advantages over the isothermal separation in terms of limits of detection and analysis time.  相似文献   

17.
The synergy of combining fast temperature programming capability and adsorption chromatography using fused silica based porous layer open tubular columns to achieve high throughput chromatography for the separation of volatile compounds is presented. A gas chromatograph with built‐in fast temperature programming capability and having a fast cool down rate was used as a platform. When these performance features were combined with the high degree of selectivity and strong retention characteristic of porous layer open tubular column technology, volatile compounds such as light hydrocarbons of up to C7, primary alcohols, and mercaptans can be well separated and analyzed in a matter of minutes. This analytical approach substantially improves sample throughput by at least a factor of ten times when compared to published methodologies. In addition, the use of porous layer open tubular columns advantageously eliminates the need for costly and time‐consuming cryogenic gas chromatography required for the separation of highly volatile compounds by partition chromatography with wall coated open tubular column technology. Relative standard deviations of retention time for model compounds such as alkanes from methane to hexane were found to be less than 0.3% (n = 10) and less than 0.5% for area counts for the compounds tested at two levels of concentration by manual injection, namely, 10 and 1000 ppm v/v (n = 10). Difficult separations were accomplished in one single analysis in less than 2 min such as the characterization of 17 components in cracked gas containing alkanes, alkenes, dienes, branched hydrocarbons, and cyclic hydrocarbons.  相似文献   

18.
Quantitative correlations between physicochemical parameters and structure of various solutes and their gas chromatographic behavior were investigated in order to predict the retention values. The identification of unknown samples in gas chromatographic routine analysis of environmental samples is enhanced by the use of these correlations in conjuction with other chromatographic methods and with mass spectrometry. The boiling points of many compounds are easily found in literature and therefore their correlation with retention values obtained in isothermal or programmed temperature analysis permit restriction of the choice of names of unknown compound to within a narrow range. The correlation between the boiling points and the retention times of chloro- and bromo-benzenes and of some chloro- and nitro- substituted phenols was investigated on non-polar capillary columns and permitted the tentative identification of many compounds belonging to these homologous series.  相似文献   

19.
In this paper, partition coefficients (distribution constants) of 14 organic compounds of environmental importance (frequently determined in indoor air) between the gas and liquid phase (polydimethylsiloxane, PDMS) are presented, determined by two gas chromatographic methods: isothermal elution and temperature programmed elution using the LTPRI (linear temperature programme retention index) approach. We examined applicability of this approach to polar compounds. We took efforts to ensure best possible accuracy and trace the possible sources of error. Precision was estimated by reproducing the results using four chromatographic columns differing in diameter and stationary phase coating thickness. We consider some factors influencing the determination of thermodynamic quantities by gas chromatography and suggest some improvements.  相似文献   

20.
Temperature-programmed retention indices for eleven cyclic organic peroxides were determined by gas chromatography on slightly polar 5% biphenyl 95% dimethylpolysiloxane columns (DB-5 and Rtx-5MS) at three heating rates (5, 10, and 20° min−1) from 60 to 300°C, using different chromatographs. Cyclic organic diperoxides and triperoxides had nearly constant retention indices when different heating rates and a short isothermal hold time (5 min) before the programmed increase in temperature were used. The usefulness of temperature-programmed retention indices was shown by using the data to predict the retention times and structures of unknown diperoxides or triperoxides derived from ketones. This is the first step in the identification of unknown cyclic organic peroxides, a process would otherwise require the availability of reference compounds. Revised: 7 and 17 November 2005  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号