首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
A useful plasma diagnostic is the measurement of electron number density. One way to accomplish such measurements is to determine the contribution to the broadening of a spectral line due to the Stark effect. To simplify and extend such electron density measurements across computer platforms, a program that calculates electron number density from the Stark-broadened hydrogen-beta line has been written for the LabVIEW® environment. This program calculates electron number densities from the field strength that would be exerted on a hydrogen atom immersed in a plasma. Using the new program, the electron number density in a glow discharge is calculated for two different operating conditions. Not surprisingly, the results indicate that to increase the current density in the discharge, the source electrodes must be reduced in surface area. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by one disk with an executable program (written for Apple Macintosh), data and text files including a manual.  相似文献   

2.
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hardcopy text, comprising the main article and an appendix, is accompanied by a disk containing the compiled program, a manual, the source code and tutorial in ASCII format, and data files. The work presented is a result of the need to facilitate collection, calibration, and extraction of data from an echelle spectrometer employing charge coupled array detection (CCD). A computer program, written using Microsoft's BASIC Professional Development System version 7.1 under MS DOS, is explained and demonstrated. Wavelength calibration requires critical spectrometer dimensions, grating counter settings, and the identification of a single spectral line. Calibration accuracies are better than ± 1 pixel across a 576 × 384 pixel array. Extraction of intensity-normalized spectra for all detected orders requires less than 3 min on a 33 MHz 80386 personal computer with an 80387 math coprocessor.  相似文献   

3.
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hard copy text is accompanied by a disk with a demonstration version of the simulation program, libraries of electronic and optical component blocks, simulation models, manual, and other files.Absorbance signals for electrothermal atomization atomic absorption spectroscopy (ETA-AAS) were generated digitally and the effect of various types and sources of noise upon the precision of the absorbance measurement was evaluated by numerical calculation. Peak area measurement, peak height measurement, and matched filtering were used for processing these signals. The performance of these three techniques in the presence of various types of noises and the sensitivity of each to small variation in the atomization conditions was calculated. It is demonstrated that significant improvement in signal-to-noise ratios can be realized by application of appropriate signal processing methods. The results also indicate that one of the principal causes for loss of precision could be the variation in the heating characteristics of the furnace.  相似文献   

4.
This paper is the third part of a series of papers dealing with spectral interferences of rare earth elements (REEs) in inductively coupled plasma atomic emission spectrometry (ICP-AES). The present article shows: (a) the spectral data of europium interferent for 200 pm wide windows centred (±100 pm) about prominent lines of scandium, yttrium and REEs; (b) the database of Q values for line interference (Ql) and Q values for (wing) background interference (Qw); (c) the detection limits measured by using the “true detection limit” criterion as proposed by P.W.J.M. Boumans and J.J.A.M. Vrakking (Spectrochim. Acta Part B, 42 (1987) 819; 43 (1988) 69). Different possibilities for improvement of the true detection limits are discussed: the use of equipment of high resolving power, the application of multicomponent analysis (MCA) techniques and preliminary separation of the matrix component combined with preconcentration of trace REEs. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hard copy text is accompanied by a disk with data and text files. The data files comprise in particular the tabular material of this article in electronic form.  相似文献   

5.
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the SAE homepage at http://www.elsevier.nl/locate/sabe. The archive contains program, data and text files. The hardcopy text describes a program that has been developed to accept data from a compact electronic spectrograph and translate the data into a display on a computer screen. The computer display mimics the view seen through a direct vision spectroscope. Atomic spectra appear as vertical lines of the appropriate color dispersed on a black field. A conventional plot of intensity versus wavelength is simultaneously displayed. The update of the display is sufficiently rapid that the image on the screen is essentially a real-time representation of the light entering the spectrograph. The system was designed for use in conjunction with video projection equipment in demonstrations to large groups of students.  相似文献   

6.
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hardcopy text, comprising the main article and one appendix, is accompanied by two installation diskettes with the software package and data files. The main article discusses the chemometric aspects of the package and explains its purpose.The IDAS software package combines three cluster analysis methods (hierarchical, non-hierarchical and fuzzy) and runs under MS Windows. Modified algorithms for non-hierarchical and fuzzy clusterings are described. The interpretation of the clustering results is facilitated by the extensive use of different types of graph. New approaches to the graphical representation of the results of fuzzy clustering are proposed.Two data sets, the Iris data by Fisher and a data set on the chemical composition of tea, are used to demonstrate the capabilities of the software.  相似文献   

7.
This paper is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta, Part B (SAB). This hardcopy text, comprising the main body and an appendix, is accompanied by a disk with programs, data files and a brief manual. The main body discusses purpose, design principle and usage of the computer software for the inductively coupled plasma atomic emission spectrometry (ICP-AES) expert system. The appendix provides a brief instruction on the manipulation of the demonstration program and relevant information on accessing the diskette.The computer software of the expert system has been developed in C++ language to simulate spectra and to select analytical lines in ICP-AES. This expert system is based on a comprehensive model of non-LTE ICP-AES, which includes expertise in plasma discharges, analyte ionization and excitation, and spectral-line shapes. The system also provides several databases in which essential elemental and spectral data are stored. A logic reasoning engine is utilized for selection of the best analytical line with a main criterion of minimizing the true detection limit. The system is user-friendly with pop-up menus, an editor for database operation, and a graphic interface for the display of simulated spectra. The system can simulate spectra and predict spectral interferences with good accuracy.  相似文献   

8.
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the SAE homepage at http://www.elsevier.nl/locate/sabe. The archive contains data files and text files. The present article is the fourth part of a series of papers discussing the spectral interferences of rare earth elements (REEs) in inductively coupled plasma atomic emission spectrometry (ICP-AES). The spectral interferences for 200-pm wide windows centred (±100 pm) around the prominent lines of the analytes, due to matrix lines and oxide radicals (LuO or YO) that emit band spectra depending on the excitation temperature (Texc.) in ICP were investigated. The main result is that for Texc.=7200 K, LuO and YO band components can be eliminated so that prominent analysis lines of La, Ce, Pr, Nd, Eu and Sm were observed on a smooth background. Texc..=7200 K was chosen as the optimal excitation temperature in the determination of traces of REEs in Lu2O3 and Y2O3, respectively. The quantification of the interferences in terms of Q-value was used in accordance with Boumans and Vrakking [Spectrochimica Acta Part B 42 (1987) 819; 43 (1188) 69]. The “best” analysis lines are free of line interferences and negligibly influenced by wing interferences and Lu2O3 and Y2O3 as matrices do not raise the real detection limits.  相似文献   

9.
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the CD-ROM accompanying this issue. The archive contains video clips. The main article discusses the scientific aspects of the subject and explains the purpose of the video files. Short, 15–30 s, digital video clips are easily controllable at the computer keyboard, which gives a speaker the ability to show fine details through the use of slow motion. Also, they are easily accessed from the computer hard drive for rapid extemporaneous presentation. In addition, they are easily transferred to the Internet for dissemination. From a pedagogical point of view, the act of making a video clip by a student allows for development of powers of observation, while the availability of the technology to make digital video clips gives a teacher the flexibility to demonstrate scientific concepts that would otherwise have to be done as ‘live’ demonstrations, with all the likely attendant misadventures. Our experience with digital video clips has been through their use in computer-based presentations by undergraduate and graduate students in analytical chemistry classes, and by high school and middle school teachers and their students in a variety of science and non-science classes. In physics teaching laboratories, we have used the hardware to capture digital video clips of dynamic processes, such as projectiles and pendulums, for later mathematical analysis.  相似文献   

10.
A program that simulates and displays the level populations of atomic systems exposed to dual-wavelength (i.e. two-colour) pulsed laser excitation in highly collisional media (such as flames and plasmas) has been developed. The program is based upon a previously published fully time-dependent density-matrix model that describes step-wise excitations of atoms with degenerate states under collision-dominated conditions, and which thus goes beyond the rate-equations formalism. This model can predict such phenomena as Rabi flopping and a.c.-Stark splitting, shifting and broadening. The program can be used as a prediction tool for laser-enhanced ionization, laser-induced fluorescence, fluorescence dip spectroscopy and other two-colour laser-based spectroscopic experiments. The program provides the user with a flexible four-level atomic system, configurable as a one- or two-step excitation ladder, along with an ionization continuum and non-laser-connected level(s) that may act as trap(s) or metastable level(s). Parameters such as level degeneracy, collisional rates and laser pulse widths, shapes, wavelengths, intensities and bandwidths are accessible to the user. The program can display both the time development of the level populations and also level populations versus laser wavelength. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by a disk containing the program DensMat, an associated on-line help file and manual, an installation program, and data files pertaining to the examples illustrated in this article. The program runs under Windows 3.1 on an IBM-compatible computer.  相似文献   

11.
This paper deals with spectral interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES) encountered with environmental materials. These samples normally contain high concentrations of aluminium, calcium, magnesium, iron, titanium, potassium and sodium. The investigations cover: (a) spectral data for Al, Ca, Mg, Fe, Ti, K and Na as interferents for 200 pm wide windows centred (±100 pm) around the prominent lines of As, B, Ba, Be, Cd, Cr, Cu, Hg, Mn, P, Pb, Sb, Se, Sn, Tl, U and Zn; (b) a data base of Q-values for line interference [QIja)] and Q-values for wing background interference [QWj(Δλa)] for two values of the excitation temperature 6200 K and 7200 K. The lines free or negligibly influenced by line interference were selected for analyte determination. Q-values were used for calculation of correction factors under a spectral line without the measurement of a reference blank at the wavelength of the prominent analysis lines. The accuracy of ICP-AES with the Q-concept as a basic methodology is checked by the analysis of a certified reference material IAEA/Sediment SD-N-1/2/. The precision of the method is characterised by an RSD of 0.6–1.7%. Extraction of trace elements soluble in aqua regia was used as a decomposition method. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta, Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the SAE homepage at http://www.elsevier.nl/locate/sabe. The archive contains the tabular material of this article in electronic form.  相似文献   

12.
This paper is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta, Part B (SAB). This hardcopy text, comprising the main body and an appendix, is accompanied by a disk with programs, data files and a brief manual. The main body discusses purpose, design principle and usage of the computer software for modelling the evaporation behaviour of particles in inductively coupled plasma atomic emission spectrometry (ICP-AES). Computer software has been developed in FORTRAN 77 language in order to simulate the evaporation behaviour of particles of refractory materials such as encountered in the analysis of advanced ceramic powders by slurry nebulization inductively coupled argon plasma atomic spectrometry. The program simulates the evaporation of single particles in the inductively coupled plasma and also enable it to calculate on the base of a given particle size distribution the evaporation behaviour of all the particles contained in a sample. In a so-called “intensity concept”, the intensity is calculated as a function of the observation height in order to determine recovery rates for slurries compared with aqueous solutions. This yields a quick insight whether a calibration with aqueous solutions can be used for analysis of slurries of a given powder by slurry nebulization ICP-AES and also is a help in determining the optimal parameters for analyses of powders by means of slurry nebulization ICP-AES.Applications for the evaporation of Al2O3 and SiC powders document the usefulness of the model for the case of a 1.5 kW argon ICP of which the temperature at 8 mm above the load coil has been determined to be 6100 K. The model predicts the maximum particle size for SiC and Al2O3 that can be transported (10–15 μm) and evaporated for a given efficiency under given experimental conditions. For both Al2O3 and SiC, two ceramic powders of different grain size were investigated. The median particle sizes cover the range typical of ceramic powders. Investigations were made for SiC A 10 (median particle size 2.2 μm), SiC F1200 (4.3 μm) and Al2O3 AKP 30 (< 1.9 μm) and Al2O3 Cilas 715 (3.0 μm), respectively, in which particles with diameters of up to 23 μm still are found.  相似文献   

13.
The possibility that no nearly-free rotors exist in the low-temperature phase II of solid CH4, as proposed in a paper that recently appeared in Spectrochimica Acta Part A [1], is discussed.  相似文献   

14.
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), a section of Spectrochimica Acta, Part B (SAB). The hardcopy text is accompanied by an electronic archive, stored on the SAE homepage at http://www.elsevier.nl/locate/sabe. The archive contains data, index and program files. The main article discusses the bibliographical purpose of the program and data files. A collective index for Spectrochimica Acta for volumes since it was split into Parts A and B, and continuing through 1991 for SAA and 1997 for SAB, is presented in DBF format, along with rudimentary data entry and access software.  相似文献   

15.
After an accidental, deliberate, or weather-related dispersion of chemicals (dispersive event), rapid determination of elemental compositions of ions in mass spectra is essential for tentatively identifying compounds. A direct analysis in real time (DART)ion source interfaced to a JEOL AccuTOFmass spectrometer provided exact masses accurate to within 2 mDa for most ions in full scan mass spectra and relative isotopic abundances (RIAs) accurate to within 15-20% for abundant isotopic ions. To speed determination of the correct composition for precursor ions and most product ions and neutral losses, a three-part software suite was developed. Starting with text files of m/z ratios and their ion abundances from mass spectra acquired at low, moderate, and high collision energies, the ion extraction program (IEP) compiled lists for the most abundant monoisotopic ions of their exact masses and the RIAs of the +1 and +2 isotopic peaks when abundance thresholds were met; precursor ions; and higher-mass, precursor-related species. The ion correlation program (ICP) determined if a precursor ion composition could yield a product ion and corresponding neutral loss compositions for each product ion in turn. The input and output program (IOP) provided the ICP with each precursor ion:product ion pair for multiple sets of error limits and prepared correlation lists for single or multiple precursor ions. The software determined the correct precursor ion compositions for 21 individual standards and for three- and seven-component mixtures. Partial deconvolution of composite mass spectra was achieved based on exact masses and RIAs, rather than on chromatography.  相似文献   

16.
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). Accompanying this hard copy text is a disk containing the program, source flies, data files and a brief manual along with a few programming notes. The main article discusses the purpose of this work, and the Appendix provides brief instruction on the use of the program, manipulation of the data, and source code. An automatic file selection system for the control of a rapid scanning spectrometer performing atomic emission spectrometry has been developed using the PROLOG language. The system can be “taught” the elemental composition of a given sample type. It uses this information (when available) to generate a linear search strategy which minimizes the number of lines that need to be measured. The rules used by the system can be observed during system operation to allow a trace of the logic. Reading of the initial data base takes no more than 6 s and then decisions are made in less than 1 s per line.  相似文献   

17.
A graphically-oriented data base of spectral interferences dut occur in inductively coupled plasma-mais spectrometry and glow discharge-mass spectrometry has been developed. The program is called “MS Interview” and runs on a Macintosh computer. The program allows one to specify which technique (ICP or GD) the various interferences will be presented for, and for the case of the ICP, the acid matrix background. Bated on these parameters the program provides a listing of interferences broken down into the following categories: Isobarics, Oxides, Doubly Charged Species, Background Dependent, and Matrix Dependent. For the glow discharge case there are two additional categories: Argides and Dimers. Interference information is provided for all masses of all elements and is easily accessed via mouse operations from a periodic table window and element mass spectral windows. The program is expandable to include other ion sources and interferences can be added or deleted as required by the user. Finally, the program also includes a small library of typical background spectra that can be displayed and manipulated. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta B (SAB). The hardcopy text is accompanied by a disk containing the program MS Interview, a manual, a reference list, and a bar graph format mass spectral library of the elements.  相似文献   

18.
This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta B (SAB). The hardcopy text, comprising the main article and an appendix, is accompanied by a diskette with a program, data files, and a manual. The text details the purpose of the work, with emphasis on the spectroscopic aspects, and the appendix provides the essential information for accessing the diskette and using program and data. Additional tutorial guidance is provided by the manual.

The program primarily concerns the simulation of the spectra of rare earth elements (REE) as interferents in 80-pm wide spectral windows centred about the wavelengths of 26 prominent lines of Ce, La, Nd, Pr, and Sm. The program essentially covers the model described in Spectrochim. Acta 43B, 1365 (1988) and the database is identical to the experimental database published in Spectrochim. Acta 44B, 31 (1989). Accordingly, the data are for an inductively coupled plasma (ICP). The program enables the user to simulate spectra with the spectral bandwidth as an optional variable. The user may then generate spectra of both single REEs, without or with analyte, and mixtures of REEs of any composition, also without or with analyte, whereby for spectra with analyte the display includes the blank spectrum. Displays are accompanied by legends providing a set of essential numerical data. In addition, particular program options allow the generation of numerical data only, one of them being the calculation of true detection limits. This option permits it to perform, within the limited scope of the database, line selection for complex REE samples in a rational way.

The program operates, in principle, with the default values of the ICP Doppler temperature (6800 K) and “average” ICP a-parameter of the Voigt profile (0.5), but these values may be optionally modified. Similarly, the user may add new data files to the base and thus also apply the program for other purposes and outside the REE environment, such as model studies in general, and for learning or teaching, as explained in the manual on the diskette. The tutorial part of this manual provides the user not only with elementary instructions for using the program as a practical tool, but also incorporates a variety of instructive examples, including a brief “course” on spectral line profiles and spectral interferences.  相似文献   


19.
This paper is the second part of a series of papers dealing with mutual spectral interferences of rare earth elements (REEs) in inductively coupled plasma atomic emission spectrometry (ICP-AES). The present article covers: (a) the spectral data of praseodymium and samarium interferents for 200 pm wide windows centred (± 100 pm) about prominent lines of scandium, yttrium and REEs; (b) the data base of Q values for line interference (Q1) and Q values for (wing) background interference (Qw); and (c) the detection limits measured by using the “true detection limit” criterion as proposed by Boumans and vrakking [Spectrochim. Acta 42B, 819 (1987); 43B, 69 (1988)]. The lines with the lowest values of true detection limits for praseodymium and samarium matrices were chosen for analysis. This article is an electronic publication in Spectrochimica Acta Electronica (SAE), the electronic section of Spectrochimica Acta Part B (SAB). The hardcopy text is accompanied by a disk with data and text files. The data files comprise in particular the tabular material of this article in electronic form.  相似文献   

20.
One of the major problems involved in the direct analysis of solid samples by electrothermal atomic absorption spectrometry (ETAAS) lies in the calibration step because non-spectral interference effects are often pronounced. Three standardization techniques have been described and used in solid sampling-ETAAS: (i) standard additions method; (ii) calibration relative to a certified reference material; and (iii) calibration curve technique. However, an adequate statistical evaluation of the uncertainty in the analyte concentration in the solid sample is most frequently neglected, and reported errors may be seriously underestimated. This can be attributed directly to the complexity of the statistical expressions required to accurately account for errors in each of the calibration techniques mentioned above, and the general lack of relevant reference literature. The object of this work has been to develop a computer package which will perform the necessary statistical analyses of solid sampling-ETAAS data; the result is the program “SOLIDS” described here in the form of an electronic publication in Spectrochimica Acta Electronica, the electronic section of Spectrochimica Acta Part B. The program could also be useful in other analytical fields where similar calibration methods are used. The hard copy text, outlining the calibration models and their associated errors, is accompanied by a diskette containing the program, some data files, and a manual. Use of the program is exemplified in the text, with some of the data files discussed included on the diskette which, together with the manual, should enable the reader to become familiarized with the operation of the program, and the results generated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号