首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To enhance the applicability of the nuclear analytical technique in the field of industry and the environment, the inorganic elemental content of the bottom ash from a municipal solid waste incinerator was determined by instrumental neutron activation analysis. Bottom ash samples were monthly collected from an incinerator located at a metropolitan city in Korea, strained through a 5 mm sieve, dried by an oven and pulverized by an agate mortar. The samples were irradiated at the NAA #1 irradiation hole (thermal neutron flux: 2.92·1013 n·cm−2·s−1) in the HANARO research reactor of the Korea Atomic Energy Research Institute and the irradiated samples were measured by a HP Ge gamma-ray spectrometer. Thirty-three elements including As, Cr, Cu, Fe, Mn, Sb and Zn were analyzed by an absolute method. The quality control was conducted by a simultaneous analysis with NIST standard reference materials. The average concentrations of the major elements such as Ca, Fe, Al, Na, Mg, K and Ti measured in the sample were 19.9%, 4.85%, 3.79%, 2.11%, 1.84%, 1.22% and 1.02%, respectively. In addition, the concentrations of the hazardous metals like Zn, Cu, Cr, Sb and As were 0.77%, 0.31%, 729 mg·kg−1, 116 mg·kg−1 and 22.2 mg·kg−1, respectively.  相似文献   

2.
A simple spectrophotometric method is presented for the determination of tetrakis [methylene (3,5-di-tert-butyl-4-hydroxyhyrocinnamate)] methane (Irganox 1010) in polymeric samples. To a solution of Irganox 1010 in acetone is added concentrated sodium hydroxide solution and then it is shaken for a short time. The 2-phase system produced in the upper phase (acetone) is yellow colored. Absorbance of the colored phase is recorded in a quartz cell at 440 nm. Different parameters such as temperature, time after mixing solutions of Irganox 1010 and sodium hydroxide, and concentration of sodium hydroxide are studied. The linear dynamic range, limit of detection and correlation coefficient (r) are 25–1000 mg·L−1, 10 mg·L−1 and 0.996, respectively. The repeatability of this method is good (n = 6, C = 250 mg·L−1, RSD = 3.26%). Correspondence: Mir Ali Farajzadeh, Department of Analytical Chemistry, Faculty of Chemistry, Tabriz University, Tabriz, Iran  相似文献   

3.
We assessed the ability of netted chain fern (Woodwardia areolata) to uptake U and Th from wetland soils on the U.S. Department of Energy’s Savannah River Site in South Carolina. Netted chain fern had the highest Th and U concentrations of all plants collected from the wetland. Ferns grown in contaminated soil (329 mg·kg−1 Th, 44 mg·kg−1 U) in a greenhouse contained 6.4 mg·kg−1 Th and 5.3 mg·kg−1 U compared with 0.13 mg·kg−1 Th and 0.035 mg·kg−1 U in Bermuda grass (Cynodon dactylon). Netted chain fern has potential for the phytoremediation of soils contaminated with Th and U.  相似文献   

4.
The electrochemical behavior of the ofloxacin–copper complex, Cu(II)L2, at a mercury electrode, and the interaction of DNA with the complex have been investigated. The experiments indicate that the electrode reaction of Cu(II)L2 is an irreversible surface electrochemical reaction and that the reactant is of adsorbed character. In the presence of DNA, the formation of the electrochemically non-active complexes Cu(II)L2-DNA, results in the decrease of the peak current of Cu(II)L2. Based on the electrochemical behavior of the Cu(II)L2 with DNA, binding by electrostatic interaction is suggested and a new method for determining nucleic acid is proposed. Under the optimum conditions, the decrease of the peak current is in proportional to the concentration of nucleic acids in the range from 3 × 10−8 to 3 × 10−6 g · mL−1 for calf thymus DNA, from 1.6 × 10−8 to 9.0 × 10−7 g · mL−1 for fish sperm DNA, and from 3.3 × 10−8 to 5.5 × 10−7 g · mL−1 for yeast RNA. The detection limits are 3.3 × 10−9, 6.7 × 10−9 and 8.0 × 10−9 g · mL−1, respectively. The method exhibits good recovery and high sensitivity in synthetic samples and in real samples.  相似文献   

5.
The sorption behavior of Sn(II) onto Haro river sand has been examined with respect to nature of electrolyte, agitation time, dosage of sorbent and concentration of sorbate. Maximum sorption (95.5%) has been achieved from 0.034M hydrochloric acid solution after equilibrating sorbate (2·10−5M) and sorbent (50 mg) for 120 minutes at aV/W ratio of 90 cm3·g−1. The kinetic data have been subjected to Morris-Weber and Lagergren equations. The kinetics of sorption proceeds a two stage process consisting of a relatively slow initial uptake followed by a much rapid increase in the sorption. The rate constant of intraparticle transport, Kd, comes out to be 8.75·10−8 mol·g−1·min−1/2 and the first order rate constant for sorption is 0.0416 min−1. The sorption data of Sn(II) onto Haro river sand followed Langmuir, Freundlich and Dubinin-Radushkevich (D-R) type isotherms. The Langmuir constant,Q, related to sorption capacity and,b, related to sorption energy are computed to be 10.6±1.1 μmol·g−1 and 1123±137 dm3·mol−1, respectively. The D-R isotherm yields the values ofC m=348±151 μmol·g−1 and β=−0.01044±0.0008 mol2·kJ−2 and ofE=6.9±0.3 kJ·mol−1. In all three isotherms correlation factor (γ) is ≥0.99. The influence of common anions and cations on the sorption has been investigated. Zn(II), Mg(II), oxalate, Pb(II), Mn(II) and tartrate reduce the sorption significantly whereas Fe(II) causes substantial increase in the sorption. It is essential that all ions causing a decrease in the sorption of Sn(II) must be absent from the sorptive solution otherwise low sorption yields would result.  相似文献   

6.
Four pyridinecarboxamide iron dicyanide building blocks and one Mn(III) compound have been employed to assemble cyanide-bridged heterometallic complexes, resulting in a series of trinuclear cyanide-bridged FeIII–MnII complexes: {[Mn(DMF)2 (MeOH)2][Fe(bpb)(CN)2]2}·2DMF (1), {[Mn(MeOH)4][Fe(bpmb)(CN)2]2}·2MeOH·2H2O (2), {[Mn(MeOH)4][Fe(bpdmb)(CN)2]2}·2MeOH·2H2O (3) and {[Mn(MeOH)4][Fe(bpClb)(CN)2]2}·4MeOH (4) (bpb2− = 1,2-bis(pyridine-2-carboxamido)benzenate, bpmb2− = 1,2-bis(pyridine-2-carboxamido)-4-methyl-benzenate, bpdmb2− = 1,2-bis(pyridine-2-carboxamido)-4,5-dimethyl-benzenate, bpClb2− = 1,2-bis(pyridine-2-carboxamido)-4-chloro-benzenate). Single-crystal X-ray diffraction analysis shows their similar sandwich-like structures, in which the two cyanide-containing building blocks act as monodentate ligands through one of their two cyanide groups to coordinate the Mn(II) center. Investigation of the magnetic properties of these complexes reveals antiferromagnetic coupling between the neighboring Fe(III) and Mn(II) centers through the bridging cyanide group. A best fit to the magnetic susceptibilities of complexes 1 and 3 gave the magnetic coupling constants J = −1.59(2) and −1.32(4) cm−1, respectively.  相似文献   

7.
Summary A rapid and accurate HPLC method is described for the simultaneous determination of acetaminophen, dextromethorphen hydrobromide and pseudoephedrine hydrochloride in a new cold formulation. Chromatographic separation of the three pharmaceuticals was performed on a Hypersil CN column (150×5.0 mm, 5 μm) with a mobile phase mixture of an ion-pairing solution, methanol and acetonitrile (25:57:18, v/v), at a flow rate of 1.0 mL min−1, with detection at 220 nm. Separation was complete in less than 10 min. The method was validated for linearity, accuracy, precision, limit of quantitation and robustness. Linearity, accuracy, and precision were found to be acceptable over the ranges of 2.06∼20.6 μg·mL−1 for acetaminophen, 0.202∼2.02 mg·mL−1 for pseudoephedrine hydrochloride and 0.042∼1.06 mg·mL−1 for dextromethorphen hydrobromide.  相似文献   

8.
A highly precise and accurate method for the determination of minor amounts of iron by substoichiometric isotope dilution analysis is described. The constant amount of Fe(III) is substoichiometrically extracted with 2·10−4M oxine in chloroform from the aqueous phase of pH 9.2–10.0 containing 6·10−3M tartrate. The interfering ions such as Mn(II), Co(II), Ni(II), Cu(II), and Zn(II), can be removed by the preliminary extraction of Fe(III) from 7.5M hydrochloric acid solutions into isopropyl ether. The present method has been applied to the determination of iron in biological standard reference materials, i.e., the NBS Spinach (SRM-1570) and the NIES Pepperbush (SRM No. 1), and the results obtained are 548±9 ppm (NBS certified value: 550±20 ppm) and 193±4 ppm, respectively.  相似文献   

9.
A method has been worked out of multi-elemental instrumental neutron-activation analysis INAA of small weights some mg of monomineral fractions of sulfide minerals pyrites, galenites, chalcopyrites, arsenopyrites, bornites, chalcosines and quartzes. The samples were irradiated in a nuclear reactor under a flux of 1.3·1013 n·cm−2·s−1. For measuring the gamma radiation of the exposed samples Ge(Li) gamma-spectrometers with semiconductor detectors were used. Determined in sulfide monofractions were the elements: Co, Sc, Ag, Se, Sb, Cr, Fe, Zr; rare-earth elements: Ce, Sm, Eu and others at content levels of 10−1−10−4%. In quartzes they were: Mn, Na, Sb, Cr, Sc, Fe, Co at content levels of 10−5−10−7% and Au to n×10−9%. A special method has been worked out for the determination of In in sulfides with the irradiation of samples in a cadmium screen. An example is cited of using the method for studying some peculiar features of the genetics of copper pyrite deposits. The data on the distribution of admixture elements in sulfide monofractions produced in this work made it possible to conclude that the oreformation in the deposits has a stage-by-stage character.  相似文献   

10.
A convenient and sensitive method for determination of sulfanilamide (SNA) was described based on the Mn(II)-catalyzed oscillating chemical reaction. Under optimum conditions, a linear relationship existed between the changes of oscillating period or amplitude and the negative of logarithm of SNA concentration in the range of 4.27 × 10−8 mol ·L−1 ∼ 7.41 × 10−6 mol ·L−1 (RSD, 0.85%) and 9.33 × 10−8 mol ·L−1 ∼ 3.02 × 10−6 mol ·L1 (RSD, 1.08%), respectively. The lower limit of detection was found to be 2.69 × 10−8 mol ·L−1 and 6.03 × 10−8 mol ·L−1, respectively.   相似文献   

11.
(E)-3-(2-chlorophenyl)-1-(2,4-dichlorophenyl) prop-2-en-1-one was prepared from 2-chlorobenzaldehyde followed by cyclization with hydrazine monohydrate. Eight new 3-(2,4-Di-chlorophenyl)-5-(2-chlorophenyl)-4,5-dihydro-N-acylpyrazole derivatives were synthesized and characterized by elemental analysis, IR and 1H NMR spectroscopy. The experimental results show that the inhibition ratio of compounds 3f towards H. Oryzae and P. oryzae at 50 mg·L−1 is 55.2% and 57.1%, respectively. The inhibition ratio of compounds 3g towards H. Oryzae, P. oryza, S. Sclerotiorum at 50 mg·L−1 is 53.3%, 60.0%, 50.4% respectively. __________ Translated from Chinese Journal of Applied Chemistry, 2007, 27(7): 835–837  相似文献   

12.
A flow injection method is described for the determination of iron in fresh water based on potassium permanganate chemiluminescence detection via oxidation of formaldehyde in aqueous hydrochloric acid. Total iron concentrations are determined after reducing Fe(III) to Fe(II) using hydroxylamine hydrochloride. The detection limit (three standard deviations of blank) is 1.0 nM, with a sample throughput of 120 h−1. The calibration graph was linear over the range (2–10) × 10−7 M (r 2 = 0.9985) with relative standard deviations (n = 5) in the range 1.0–2.3%. The effect of interfering cations (Ca(II), Mg(II), Zn(II), Ni(II), Co(II), Fe(III), Mn(II), Pb(II), and Cu(II)) and common anions (Cl, SO 4 2− , PO 4 3− , NO 3 , NO 2 , I, F, and SO 3 2− ) was studied at their maximum admissible concentrations in fresh water. The method was applied to fresh-water samples from the Quetta Valley, and the results obtained (0.04 ± 0.001–0.11 ± 0.01 mg/L Fe(II)) were in reasonable agreement with those obtained using the spectrophotometric reference method (0.05 ± 0.01–0.12 ± 0.02 mg/L Fe(II)). The text was submitted by the authors in English.  相似文献   

13.
Chemical compositions of spherules separated from deep sea sediment dredged off Hawaiian islands and from Antarctic ice were measured by instrumental neutron activation analysis (INAA) using Kyoto University Reactor (KUR). Iron, cobalt, nickel, iridium, scandium and manganese contents in those spherules were determined to be 19.3–97.7%, 23–4370 mg·kg−1, 0.08–7.04%, 0.84–35.4 mg·kg−1, 1.4–44.3 mg·kg−1 and 93.4 mg·kg−1–7.2 %, respectively, and compared with each other. Particularly, iridium was detected in seven spherules among fourteen from Hawaii, but only one spherule among twenty-two from Antarctic, and those spherules turned out to be extraterrestrial in origin. However, it was shown that there was little difference in characteristics of elemental contents between both kinds of spherules, except for Ir-detected spherules.  相似文献   

14.
 Squaric acid (1,2-dihydroxy-3,4-diketo-cyclobutene) is used in a specific reaction with Fe(III) for the spectrophotometric determination of Fe(III) and total iron content. The optimization of the experimental parameters leads to the establishment of a simple, fast and accurate analytical method. The analytical procedure includes mixing ammonium squarate (40 mM), prepared in a phthalate buffer solution of pH 2.7, with the sample and measuring the absorbance at 515 nm. The molar absorptivity of the colored product is 3.95×103 L·mol−1·cm−1, at 515 nm. Calibration graphs for Fe(III) are rectilinear for 0.5–20 mgL−1, with a detection limit of 0.3 mgL−1 and r.s.d. not exceeding 2.5%, for five replicates of a 3.0 mgL−1 standard solution. The method has been successfully applied to the determination of iron (III) and the total iron content after quantitative oxidation of iron (II). The results for several analyzed samples when compared with those acquired by using the FAAS technique, were found to be in satisfactory agreement. Author for correspondence: University of Ioannina, Department of Chemistry, Laboratory of Analytical Chemistry, Ioannina 451 10, Greece. E-mail: panavelt@cc.uoi.gr Received July 27, 2002; accepted December 20, 2002 Published online April 11, 2003  相似文献   

15.
The reaction of mercury(II) with 3-(2,4-dihydroxyphen-1-ylazo)-1,2,4-triazole (HL1), 3-(2-hydroxy-5-methylphen-1-ylazo)-1,2,4-triazole (HL2), 3-(2-hydroxy-5-ethoxycarbonylphen-1-ylazo)-1,2,4-triazole (HL3), 3-(2-hydroxy-5-acetylphen-1-ylazo)-1,2,4-triazole (HL4), 3-(2-hydroxy-5-formylphen-1-ylazo)-1,2,4-triazole (HL5), and 3-(2-hydroxy-5-bromophen-1-ylazo)-1,2,4-triazole (HL6) was studied. A new, direct, and simple procedure was suggested for the spectrophotometric determination of mercury(II) based on its complexation reaction with HL1-HL6. The best reagent was found to be HL3 due to its high sensitivity and selectivity. In aqueous media of pH 9.0 containing 40 vol. % of methanol, Hg(II) reacts with HL3 to form a 1:2 (Hg(II) · HL3) complex having a sensitive absorption peak at 490 nm with the molar extinction coefficient of 3.31 × 104 L mol−1 cm−1 using 4 × 10−4 M of the reagent. Beer’s law is obeyed over the range from 0.00 μg mL−1 to 12.04 μg mL−1 of mercury(II). The proposed method was applied in the determination of mercury(II) in tap water, seawater and synthetic seawater samples, without the need of prior treatment, with satisfactory results.  相似文献   

16.
During this work the determination of uranium in the range of μg·L−1 to tens of μg·L−1 was done by alpha-spectrometry after electroplating the aliquots of water sample using (NH4)2SO4 as an electrolyte. In general, the determination of uranium by alpha-spectrometry needs its separation from other transuranics specially thorium. The process described here does not involve any sample digestion and radiochemical separation of uranium from other transuranics. In this method an aliquot (1 to 3 mL) of the sample was dried and dissolve in (NH4)2SO4 and thereafter the sample was electroplated on a stainless steel (SS) planchet by using an electrochemical cell of special design. The proposed techniques have a distinct advantage over the determination of uranium by adsorptive stripping voltammetry (AdSV) in which uranium-chloranilic (2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone) acid complex was used for concentrating the uranium from the solution. Since in the case of AdSv, the determination of uranium was not possible for samples having dissolved organic carbon (DOC) more than 15 mg·L−1 and Cl concentration is in the range of 40,000 μ·g−1. In the case of spike experiments with 232U the recovery was observed in the range of 90–95% in aqueous medium having higher concentration of Cl and DOC as indicated above.  相似文献   

17.
A systematic non-destructive determination of eighteen trace elements (F, Na, Cl, Sc, Mn, Zn, Br, Sr, I, Ba, La, Ce, Sm, Eu, Tb, Yb, Th and U) in carbonate samples by thermal neutron activation analysis was developed. Three 0.2–0.5g samples were irradiated for 15 sec (in the case of determination of F), for 3 min (in the case of Na, Cl, Mn, Sr and I) and for 60 hrs (in the case of Sc, Zn, Br, Ba, La, Ce, Sm, Eu, Tb, Yb, Th and U) in the TRIGA MARK II Reactor at a thermal neutron flux of 5·1011 n·cm−2·sec−1 (15 sec and 3 min irradiation) and 1.5·1012n·cm−2·sec−1 (60 hrs irradiation), respectively. According to the half life of the nuclides formed, the activities were measured with a Ge(Li) spectrometer as follows,20F∶15 sec counting after 20–25 sec cooling,24Na,38Cl,56Mn,87mSr and128I∶600 sec couting after 30–120 min cooling,82Br,140La,153Sm,175Yb and239Np (daughter of239U)∶3000 sec counting after 1 week cooling,46Sc,65Zn,131Ba,141Ce,152Eu,160Tb and233Pa (daughter of233Th)∶5000 sec counting after 1 month cooling. The errors due to the fluctuation of the neutron flux and the counting geometry were minimized by the use of calcium determined previously with EDTA-titration as an internal standard. The interferences from24Mg(n, p)24Na and235U(n, fission) reactions were corrected by the activities produced by the reactions in unit weight of magnesium and uranium, and their concentrations in samples measured experimentally. The data of Na, Mn, Zn and Sr were compared with the results obtained by atomic absorption analysis.  相似文献   

18.
The development of a spectrophotometric method for the determination of hydrogen peroxide in uranyl nitrate solutions is reported. The method involves the measurement of the absorbance at 520 nm of a vanadyl peroxide species. This species was formed by the addition of a reagent consisting of vanadium (V) (50 mmol·dm−3) in dilute sulphuric acid (2 mol·dm−3 H2SO4). This reagent, after dilution, was also used as an extractant for organic phase samples. The method is simple and robust and tolerant of nitric acid and U(VI). Specificity and accuracy were improved by the application of solid phase extraction techniques to remove entrained organic solvents and Pu(IV). Reverse phase solid phase extraction was used to clean-up aqueous samples or extracts which were contaminated with entrained solvent. A solid phase extraction system based upon an extraction chromatography system was used to remove Pu(IV). Detection limits of 26 μmol·dm−3 (0.88 μg·cm−3) or 7 μmol·dm−3 (0.24 μg·cm−3) for, respectively, a 1 and 4 cm path length cell were obtained. Precisions of RSD=1.4% and 19.5% were obtained at the extremes of the calibration curve (5 mmol·dm−3 and 50 μmol·dm−3 H2O2, 1 cm cell). The introduction of the extraction and clean-up stages had a negligible effect upon the precision of the determination. The stability of an organic phase sample was tested and no loss of analyte could be discerned over a period of at least 5 days. The presence of trace levels of reductants interfered with the determination, e.g., hydrazine (<2 mmol·dm−3), but this effect was ameliorated by increasing the concentration of the colormetric reagent.  相似文献   

19.
The Fe(III) uptake from aqueous solutions by natural and chemically modified zeolites was investigated using a gradual radioexchange method and AAS technique. The leachability of Fe(III) from loaded zeolites was studied too. The Fe-uptake reached the value of 60 mg·g−1 for the zeolite chemically treated with 6 mol·l−1 solution of NaOH and it is more than twelve times higher than that of the raw zeolite. The leachability of the loaded zeolite samples in water and alkaline solution was up 5%. The leachability of the same zeolites in acid solution depended on the concentration of modifying solution. The leachability at pH=2.6 in the range 2–20% at pH=1.9 was many times higher. The results of the radioexchange and AAS methods were compared.  相似文献   

20.
A combined method involving electrochemical oxidation of iodide to iodate at a platinum electrode followed by extraction in CCl4 of ionic associates of iodine-iodide complexes with brilliant green, formed in excess of iodide, was developed for the spectrophotometric quantification of iodide. The slope of the calibration curve yields a molar extinction coefficient of ɛ = 3·105 L mol−1cm−1. This method can be used for the quantification of iodide in the concentration range of 3·10−7 − 3·10−6 mol L−1 with a detection limit of 5·10−8 mol L−1. The interfering effect of other ions on the determination of the iodide concentration was also investigated. The method was successfully applied for the determination of iodide in real samples of NaCl and spring water. Relative standard deviation is 1–2%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号