首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
Roundup Ready soybean powder has been subjected to different amounts of DNA fragmentation to assess the accuracy of real-time PCR on processed food. Certified reference material (CRM) containing 10 g kg−1 of Roundup Ready soybean (ERM-BF410d) prepared by a dry-mixing processing method was exposed to water at two temperatures, using three different mixing devices, or to baking temperature (250°C) for 30 min. The amount of DNA extracted from the different samples was quantified by fluorimetry. The amount of fragmentation of the extracted DNA was characterised by gel and capillary electrophoresis and the percentage of genetically modified (GM) soybean was determined by a double quantitative real-time PCR method. Measurement of the event GTS 40-3-2 (RUR) was possible in all the treated materials, because small amplicons were amplified. Correct RUR percentages could be measured for intact powders with little or no DNA fragmentation. For samples with a high level of DNA degradation, however, the accuracy of the measurement was found to depend on the method used for DNA extraction. Genomic DNA isolated by use of silica resin resulted in statistically significant overestimation of the amount of GM.  相似文献   

2.
Sample preparation methods used for genetically modified organisms (GMOs) analysis are often time consuming, require extensive manual manipulation, and result in limited amounts of purified protein, which may complicate the detection of low‐abundance GM protein. A robust sample pretreatment method prior to mass spectrometry (MS) detection of the transgenic protein (5‐enolpyruvylshikimate‐3‐phosphate synthase [CP4 EPSPS]) present in Roundup Ready soya is investigated. Liquid chromatography‐multiple reaction monitoring tandem MS (nano LC‐MS/MS‐MRM) was used for the detection and quantification of CP4 EPSPS. Gold nanoparticles (AuNPs) and concanavalin A (Con A)‐immobilized Sepharose 4B were used as selective probes for the separation of the major storage proteins in soybeans. AuNPs that enable the capture of cysteine‐containing proteins were used to reduce the complexity of the crude extract of GM soya. Con A‐sepharose was used for the affinity capture of β‐conglycinin and other glycoproteins of soya prior to enzymatic digestion. The methods enabled the detection of unique peptides of CP4 EPSPS at a level as low as 0.5% of GM soya in MRM mode. Stable‐isotope dimethyl labeling was further applied to the quantification of GM soya. Both probes exhibited high selectivity and efficiency for the affinity capture of storage proteins, leading to the quantitative detection at 0.5% GM soya, which is a level below the current European Union's threshold for food labeling. The square correlation coefficients were greater than 0.99. The approach for sample preparation is very simple without the need for time‐consuming protein prefractionation or separation procedures and thus presents a significant improvement over existing methods for the analysis of the GM soya protein.  相似文献   

3.
The potential of protein fractionation hyphenated to mass spectrometry (MS) to detect and characterize the transgenic protein present in Roundup Ready soya and maize has been investigated. Genetically modified (GM) soya and maize contain the 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS) gene from Agrobacterium tumefaciens CP4, which confers resistance to the herbicide glyphosate. The GM soya and maize proteomes were fractionated by gel filtration, anion-exchange chromatography and sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE) prior to MS. This facilitated detection of a tryptic peptide map of CP4 EPSPS by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS and nanoelectrospray ionization quadrupole time-of-flight (nanoESI-QTOF) MS. Subsequently, sequence information from the CP4 EPSPS tryptic peptides was obtained by nanoESI-QTOF MS/MS. The identification was accomplished in 0.9% GM soya seeds, which is the current EU threshold for food-labeling requirements.  相似文献   

4.
Labelling requirements for genetically modified organisms state that any product, containing or consisting of GMOs or products thereof, above a threshold of 0.9% need to be labelled accordingly. Reviewing projects of the UK Food Standards Agency on determination of GMO percentage in processed products as well as problems with certain series of Roundup Ready soybean certified reference materials, it seems impossible to accurately analyse any product for their GMO content and get the percentage right. The articles discusses analytical problems and pitfalls and shows what can and cannot be enforced.  相似文献   

5.
Guo L  Qiu B  Chi Y  Chen G 《Electrophoresis》2008,29(18):3801-3809
In this paper, an ultrasensitive CE-CL detection system coupled with a novel double-on-column coaxial flow detection interface was developed for the detection of PCR products. A reliable procedure based on this system had been demonstrated for qualitative and quantitative analysis of genetically modified organism-the detection of Roundup Ready Soy (RRS) samples was presented as an example. The promoter, terminator, function and two reference genes of RRS were amplified with multiplex PCR simultaneously. After that, the multiplex PCR products were labeled with acridinium ester at the 5'-terminal through an amino modification and then analyzed by the proposed CE-CL system. Reproducibility of analysis times and peak heights for the CE-CL analysis were determined to be better than 0.91 and 3.07% (RSD, n=15), respectively, for three consecutive days. It was shown that this method could accurately and qualitatively detect RRS standards and the simulative samples. The evaluation in terms of quantitative analysis of RRS provided by this new method was confirmed by comparing our assay results with those of the standard real-time quantitative PCR (RT-QPCR) using SYBR Green I dyes. The results showed a good coherence between the two methods. This approach demonstrated the possibility for accurate qualitative and quantitative detection of GM plants in a single run.  相似文献   

6.
For enforcement of the recently introduced labeling threshold for genetically modified organisms (GMOs) in food ingredients, quantitative detection methods such as quantitative competitive (QC-PCR) and real-time PCR are applied by official food control laboratories. The experiences of 3 European food control laboratories in validating such methods were compared to describe realistic performance characteristics of quantitative PCR detection methods. The limit of quantitation (LOQ) of GMO-specific, real-time PCR was experimentally determined to reach 30-50 target molecules, which is close to theoretical prediction. Starting PCR with 200 ng genomic plant DNA, the LOQ depends primarily on the genome size of the target plant and ranges from 0.02% for rice to 0.7% for wheat. The precision of quantitative PCR detection methods, expressed as relative standard deviation (RSD), varied from 10 to 30%. Using Bt176 corn containing test samples and applying Bt176 specific QC-PCR, mean values deviated from true values by -7to 18%, with an average of 2+/-10%. Ruggedness of real-time PCR detection methods was assessed in an interlaboratory study analyzing commercial, homogeneous food samples. Roundup Ready soybean DNA contents were determined in the range of 0.3 to 36%, relative to soybean DNA, with RSDs of about 25%. Taking the precision of quantitative PCR detection methods into account, suitable sample plans and sample sizes for GMO analysis are suggested. Because quantitative GMO detection methods measure GMO contents of samples in relation to reference material (calibrants), high priority must be given to international agreements and standardization on certified reference materials.  相似文献   

7.
A highly sensitive quantitative real-time assay targeted on the 35S promoter of a commercial genetically modified organism (GMO) was characterized (sF/sR primers) and developed for an ABI Prism 7700 Sequence Detection System and TaqMan chemistry. The specificity assessment and performance criteria of sF/sR assay were compared to other P35S-targeted published assays. sF/sR primers amplified a 79 base pair DNA sequence located in a part of P35S that is highly conserved among many caulimovirus strains, i.e., this consensus part of CaMV P35S is likely to be present in many GM events. According to the experimental conditions, the absolute limit of detection for Bt176 corn was estimated between 0.2 and 2 copies of equivalent genome (CEG). The limit of quantification was reached below 0.1% Bt176 content. A Cauliflower Mosaic Virus control (CaMV) qualitative assay targeted on the ORF III of the viral genome was also used as a control (primers 3F/3R) to assess the presence of CaMV in plant-derived products. The specificity of this test was assessed on various CaMV strains, including the Figwort Mosaic Virus (FMV) and solanaceous CaMV strains. Considering the performance of sF/sR quantification test, the highly conserved sequence, and the small size of the amplicon, this assay was tested in a collaborative study in order to be proposed as an international standard.  相似文献   

8.
It is generally assumed that in order to achieve suitable separations of DNA fragments, capillary gel electrophoresis (CGE)-coated capillaries should be used. In this work, a new method is presented that allows to obtain reproducible CGE separations of DNA fragments using bare fused-silica capillaries without any previous coating step. The proposed method only requires: (i) a capillary washing with 0.1 M hydrochloric acid between injections and (ii) a running buffer composed of Tris-phosphate-ethylenediamine tetraacetic acid (EDTA) and 4.5% of 2-hydroxyethyl cellulose (HEC) as sieving polymer. The use of this new CGE procedure gives highly resolved and reproducible separations of DNA fragments ranging from 50 to 750 bp. The separation of these DNA fragments is accomplished in less than 30 min with efficiencies up to 1.7 x 10(6) plates/m. Reproducibility values of migration times (given as %RSD) for the analyzed DNA fragments are better than 1.0% (n = 4) for the same day, 2.2% (n = 16) for four different days, and 2.3% (n = 16) for four different capillaries. The usefulness of this separation method is demonstrated by detecting genetically modified maize and genetically modified soy after DNA amplification by PCR. This new CGE procedure together with LIF as detector provides sensitive analysis of 0.9% of Bt11 maize, Mon810 maize, and Roundup Ready soy in flours with S/ N up to 542. These results demonstrate the usefulness of this procedure to fulfill the European regulation on detection of genetically modified organisms in foods.  相似文献   

9.
An interlaboratory study was conducted to evaluate a method for determination of the percentage of RoundUp Ready (RR) soya in soya flour using Taqman technology. The method included DNA extraction from the test portion with cetyltrimethylammonium bromide buffer followed by chloroform extraction and Wizard resin cleanup steps. The DNA was then assayed with primer and probe sets specific for lectin as the endogenous control and the RR insert as the target. The percentage of RR soya in the soya fraction of the sample was calculated by using a matrix-matched standard curve. Ten samples of split-level blind duplicates were sent to 22 laboratories in 12 countries worldwide. Test portions contained 0, 0.5, 0.7,1.6, 2, and 3.9% (w/w) RR soya prepared gravimetrically from commercially available RR standard reference materials. Based on the results for test materials, the relative standard deviation for repeatability (RSDr) for the method ranged from 9.3 to 19.3% and, for reproducibility (RSDR), ranged from 20.3 to 33.7%.  相似文献   

10.
Quantitative and qualitative methods based on PCR have been developed for genetically modified organisms (GMO). Interlaboratory studies were previously conducted for GMO quantitative methods; in this study, an interlaboratory study was conducted for a qualitative method for a GM soybean, Roundup Ready soy (RR soy), with primer pairs designed for the quantitative method of RR soy studied previously. Fourteen laboratories in Japan participated. Each participant extracted DNA from 1.0 g each of the soy samples containing 0, 0.05, and 0.10% of RR soy, and performed PCR with primer pairs for an internal control gene (Le1) and RR soy followed by agarose gel electrophoresis. The PCR product amplified in this PCR system for Le1 was detected from all samples. The sensitivity, specificity, and false-negative and false-positive rates of the method were obtained from the results of RR soy detection. False-negative rates at the level of 0.05 and 0.10% of the RR soy samples were 6.0 and 2.3%, respectively, revealing that the LOD of the method was somewhat below 0.10%. The current study demonstrated that the qualitative method would be practical for monitoring the labeling system of GM soy in kernel lots.  相似文献   

11.
The use of droplet-based microfluidics and peptide nucleic acid molecular beacons for the detection of polymerase chain reaction (PCR)-amplified DNA sequences within nanoliter-sized droplets is described in this work. The nanomolar–attomolar detection capabilities of the method were preliminarily tested by targeting two different single-stranded DNA sequences from the genetically modified Roundup Ready soybean and the Olea europaea genomes and detecting the fluorescence generated by peptide nucleic acid molecular beacons with fluorescence microscopy. Furthermore, the detection of 10 nM solutions of PCR amplicon of DNA extracted from leaves of O. europaea L. encapsulated in nanoliter-sized droplets was performed to demonstrate that peptide nucleic acid molecular beacons can discriminate O. europaea L. cultivar species carrying different single-nucleotide polymorphisms.
Figure
The fluorescence generated by peptide nucleic acid molecular beacons allows the detection of 100-200 attomoles of PCR-amplified DNA sequences from solutions encapsulated in nanoliter-sized droplets.  相似文献   

12.
New quantitation methods based on a real-time polymerase chain reaction (PCR) technique were developed for 5 lines of genetically modified (GM) maize, including MON810, Event176, Bt11, T25, and GA21, and a GM soy, Roundup Ready. Oligonucleotide DNA, including specific primers and fluorescent dye-labeled probes, were designed for PCRs. Two plasmids were constructed as reference molecules (RMs) for the detection of GM maize and GM soy. The molecules contain the DNA sequences of a specific region found in each GM line, universal sequences used in various GM lines, such as cauliflower mosaic virus 35S promoter and nopaline synthase terminator, and the endogenous DNA sequences of maize or soy. By using these plasmids, no GM maize and GM soy were required as reference materials for the qualitative and quantitative PCR technique. Test samples containing 0, 0.10, 0.50, 1.0, 5.0, and 10% GM maize or GM soy were quantitated. At the 5.0% level, the bias (mean-true value) ranged from 2.8 to 19.4% and the relative standard deviation was <5.2%. These results show that our method involving the use of these plasmids as RMs is reliable and practical for quantitation of GM maize and GM soy.  相似文献   

13.
Certified reference materials (CRMs) are an essenIial tool in the quality assurance of analytical measurements. They are produced, certified, and used in accordance with relevant ISO (International Organization for Standardization) and BCR (Community Bureau of Reference) guidelines. The Institute for Reference Materials and Measurements (IRMM; Geel, Belgium) has produced the first powdery genetically modified organism (GMO) CRMs in cooperation with the Institute for Health and Consumer Protection (Ispra, Italy). Until now, different weight percentages in the range of 0-5% for 4 GMOs in Europe were produced and certified: Bt (Bacillus thuringiensis)-11 and Bt-176 maize, Roundup Ready soybean, and MON810 maize. Bt-11 and Bt-176 maize and Roundup Ready soybean were produced by IRMM on behalf of Fluka Chemie AG (Buchs, Switzerland). Characterization of used base material is the first step in production and is especially important for GMO CRMs. The production of powdery GMO CRMs and methods used for production control are described. Thorough control of homogeneity and stability are essential for certification of reference materials and ensure validity of the certificate for each bottle of a batch throughout a defined shelf-life. Because production of reference materials and their maintenance are very labor- and cost-intensive tasks, the usefulness of new types of GMO CRMs must be estimated carefully.  相似文献   

14.
State of the art and limitations of quantitative polymerase chain reaction   总被引:8,自引:0,他引:8  
Consequential to the implementation of European Commission (EC) Regulation 1139/98, EC Regulation 49/2000, and EC Regulation 50/2000 has been the need to measure accurately the levels of the genetically modified (GM) species Roundup Ready Soya and Bt 176 Maize that are present in food. Analytical methods to detect and quantitate these transgenic species have received much attention particularly with respect to the deminimus threshold of 1% for their presence in materials derived from non-GM identity-preserved (IP) supplies. The relative advantages and limitations of threshold analysis by double-competitive polymerase chain reaction (PCR) and quantitative real-time PCR are discussed in their application to the quantitative analysis of processed foods. Consideration is also given to other factors involved in the analyses that affect the performance of quantitative procedures, and to the many uncertainties involved in the precision of a reported analytical result.  相似文献   

15.
Several techniques have been developed for detection and quantification of genetically modified organisms, but quantitative real-time PCR is by far the most popular approach. Among the most commonly used real-time PCR chemistries are TaqMan probes and SYBR green, but many other detection chemistries have also been developed. Because their performance has never been compared systematically, here we present an extensive evaluation of some promising chemistries: sequence-unspecific DNA labeling dyes (SYBR green), primer-based technologies (AmpliFluor, Plexor, Lux primers), and techniques involving double-labeled probes, comprising hybridization (molecular beacon) and hydrolysis (TaqMan, CPT, LNA, and MGB) probes, based on recently published experimental data. For each of the detection chemistries assays were included targeting selected loci. Real-time PCR chemistries were subsequently compared for their efficiency in PCR amplification and limits of detection and quantification. The overall applicability of the chemistries was evaluated, adding practicability and cost issues to the performance characteristics. None of the chemistries seemed to be significantly better than any other, but certain features favor LNA and MGB technology as good alternatives to TaqMan in quantification assays. SYBR green and molecular beacon assays can perform equally well but may need more optimization prior to use.  相似文献   

16.
Here we report an electrochemical biosensor that would allow for simple and rapid analysis of nucleic acids in combination with nuclease activity on nucleic acids and electroactive bionanoparticles. The detection of single-nucleotide polymorphisms (SNPs) using PNA probes takes advantage of the significant structural and physicochemical differences between the full hybrids and SNPs in PNA/DNA and DNA/DNA duplexes. Ferrocene-conjugated chitosan nanoparticles (Chi-Fc) were used as the electroactive indicator of hybridization. Chi-Fc had no affinity towards the neutral PNA probe immobilized on a gold electrode (AuE) surface. When the PNA probe on the electrode surface hybridized with a full-complementary target DNA, Chi-Fc electrostatically attached to the negatively-charged phosphate backbone of DNA on the surface and gave rise to a high electrochemical oxidation signal from ferrocene at ∼0.30 V. Exposing the surface to a single-stranded DNA specific nuclease, Nuclease S1, was found to be very effective for removing the nonspecifically adsorbed SNP DNA. An SNP in the target DNA to PNA made it susceptible to the enzymatic digestion. After the enzymatic digestion and subsequent exposure to Chi-Fc, the presence of SNPs was determined by monitoring the changes in the electrical current response of Chi-Fc. The method provided a detection limit of 1 fM (S/N = 3) for the target DNA oligonucleotide. Additionally, asymmetric PCR was employed to detect the presence of genetically modified organism (GMO) in standard Roundup Ready soybean samples. PNA-mediated PCR amplification of real DNA samples was performed to detect SNPs related to alcolohol dehydrogenase (ALDH). Chitosan nanoparticles are promising biometarials for various analytical and pharmaceutical applications. Figure The electrochemical method for SNP detection using PNA probes and chitosan nanoparticles takes advantage of the significant structural and physicochemical differences between PNA/DNA and DNA/DNA duplexes. Single-stranded DNA specific enzymes selectively choose these SNP sites and hydrolyze the DNA molecules on gold electrode (AuE) surface. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

17.
The authors describe an SPR sensor chip coated with gold nanoparticles (AuNPs) that enables highly sensitive determination of genetically modified (GM) crops. Detection is based on localized surface plasmon resonance (LSPR) with its known sensitivity to even minute changes in refractive index. The device consists of a halogen light source, a light detector, and a cuvette cell that contains a sensor chip coated with AuNPs. It is operated in the transmission mode of the optical path to enhance the plasmonic signal. The sample solution containing target DNA (e.g. from the GM crop) is introduced into the cuvette with the sensor chip whose surface was functionalized with a capture DNA. Following a 30-min hybridization, the changes of the signal are recorded at 540 nm. The chip responds to target DNA in the 1 to 100 nM concentration range and has a 1 nM detection limit. Features of this sensor chip include a short reaction time, ease of handling, and portability, and this enables on-site detection and in-situ testing.
Graphical abstract A localized surface plasmon resonance (LSPR)-based nanoplasmonic spectroscopic device enabling a highly sensitive biosensor is developed for the detection of genetically modified (GM) DNA founded in Roundup Ready (RR) soybean.
  相似文献   

18.
Novel analytical methods based on real-time quantitative polymerase chain reactions by use of new reference molecules were validated in interlaboratory studies for the quantitation of genetically modified (GM) maize and soy. More than 13 laboratories from Japan, Korea, and the United States participated in the studies. The interlaboratory studies included 2 separate stages: (1) measurement tests of coefficient values, the ratio of recombinant DNA (r-DNA) sequence, and endogenous DNA sequence in the seeds of GM maize and GM soy; and (2) blind tests with 6 pairs of maize and soy samples, including different levels of GM maize or GM soy. Test results showed that the methods are applicable to the specific quantitation of the 5 lines of GM maize and one line of GM soy. After statistical treatment to remove outliers, the repeatability and reproducibility of these methods at a level of 5.0% were <13.7 and 15.9%, respectively. The quantitation limits of the methods were 0.50% for Bt11, T25, and MON810, and 0.10% for GA21, Event176, and Roundup Ready soy. The results of blind tests showed that the numerical information obtained from these methods will contribute to practical analyses for labeling systems of GM crops.  相似文献   

19.
Genetically modified carnation (Dianthus caryophyllus L.) Moonshade was approved for planting and commercialization in several countries from 2004. Developing methods for analyzing Moonshade is necessary for implementing genetically modified organism labeling regulations. In this study, the 5'-transgene integration sequence was isolated using thermal asymmetric interlaced (TAIL)-PCR. Based upon the 5'-transgene integration sequence, conventional and TaqMan real-time PCR assays were established. The relative limit of detection for the conventional PCR assay was 0.05 % for Moonshade using 100 ng total carnation genomic DNA, corresponding to approximately 79 copies of the carnation haploid genome, and the limits of detection and quantification of the TaqMan real-time PCR assay were estimated to be 51 and 254 copies of haploid carnation genomic DNA, respectively. These results are useful for identifying and quantifying Moonshade and its derivatives.  相似文献   

20.
The detection of genetically modified (GM) materials in food and feed products is a complex multi-step analytical process invoking screening, identification, and often quantification of the genetically modified organisms (GMO) present in a sample. “Combinatory qPCR SYBR®Green screening” (CoSYPS) is a matrix-based approach for determining the presence of GM plant materials in products. The CoSYPS decision-support system (DSS) interprets the analytical results of SYBR®GREEN qPCR analysis based on four values: the C t- and T m values and the LOD and LOQ for each method. A theoretical explanation of the different concepts applied in CoSYPS analysis is given (GMO Universe, “Prime number tracing”, matrix/combinatory approach) and documented using the RoundUp Ready soy GTS40-3-2 as an example. By applying a limited set of SYBR®GREEN qPCR methods and through application of a newly developed “prime number”-based algorithm, the nature of subsets of corresponding GMO in a sample can be determined. Together, these analyses provide guidance for semi-quantitative estimation of GMO presence in a food and feed product.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号