首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The mechanism of atmospheric pressure (AP) laser ionization of water and water/glycerol liquid samples at a 3-microm wavelength is studied experimentally. For the ion desorption, an in-house built Yb : YAG-pumped optical parametric oscillator (OPO) infrared (IR) laser has been coupled with AP MALDI ion source interfaced to an ion trap mass spectrometer (MS). It has been shown that water is primarily responsible for ion generation in water/glycerol samples, while glycerol increases the solution viscosity and decreases the water evaporation rate and sample losses. In contrast to AP UV-MALDI, the electric field in the case of AP IR-MALDI does not assist in ion production. It was found that the absence of the electrical field provides the optimum ionization condition both for water and water/glycerol liquid samples at the 3-microm laser irradiation. A two-stage ion formation mechanism, which includes the initial emission of microdroplets and release of molecular ions at the second stage, can explain the experimentally observed ion signal dependencies upon the voltage applied between MS inlet and the MALDI sample plate. Postionization using additional corona discharge APCI increases the observed signal by approximately 50%, which indicates that some portion of the analyte is desorbed in the form of neutral molecules.  相似文献   

2.
A new atmospheric pressure (AP) infrared (IR) matrix-assisted laser desorption/ionization (MALDI) ion source was developed and interfaced with a Thermo Finnigan LCQ ion trap mass spectrometer. The source utilized a miniature all-solid-state optical parametric oscillator (OPO)-based IR laser system tunable in the lambda = 1.5-4 microm spectral range and a nitrogen ultraviolet (UV) laser (lambda = 337 nm) for use in comparative studies. The system demonstrated comparable performance at 3 microm and 337 nm wavelengths if UV matrices were used. However, AP IR-MALDI using a 3 microm wavelength showed good performance with a much broader choice of matrices including glycerol and liquid water. AP IR-MALDI mass spectra of peptides in the mass range up to 2000 Da were obtained directly from aqueous solutions at atmospheric conditions for the first time. A potential use of the new AP IR-MALDI ion source includes direct MS analysis of biological cells and tissues in a normal atmospheric environment as well as on-line coupling of mass spectrometers with liquid separation techniques.  相似文献   

3.
Insufficient vacuum stability of matrix chemicals is a major limitation in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) of large tissue sample cohorts. Here, we designed and synthesized the photo-cleavable caged molecule 4,5-dimethoxy-2-nitrobenzyl-2,5-dihydroxyacetophenone (DMNB-2,5-DHAP) and employed it for lipid MALDI-MSI of mouse brain tissue sections. DMNB-2,5-DHAP is vacuum-stable in a high vacuum MALDI ion source for at least 72 h. Investigation of the uncaging process suggested that the built-in laser (355 nm) in the MALDI ion source promoted the in situ generation of 2,5-DHAP. A caging group is used for the first time in designing a MALDI matrix that is vacuum-stable, uncaged upon laser irradiation during the measurement process, and that boosts lipid ion intensity with MALDI-2 laser-induced postionization.  相似文献   

4.
We report a simple method for converting solid matrices into useful matrix solutions for matrix-assisted laser desorption/ionization (MALDI). This method is based on the dissolution of the solid matrix in a liquid support of low volatility such as glycerol. An appropriate solubilizing reagent was added to promote the dissolution of the matrix materials into the liquid support. Selection of the solubilizing reagent is empirically related to an acid-base relationship, i.e., an acidic solid matrix requires a basic organic compound to form a stable matrix solution in the liquid support and vice versa. A tenfold increase in the solubility can be obtained for many solid matrices when appropriate solubilizing reagents are added into the glycerol support. This solubility enhancement is tentatively attributed to the ion-pair formation in a polar nonvolatile liquid support. In addition, the hydrophobicity of the solid matrix seems to play an important role in the efficiency of the resulting matrix solution. By using glycerol as liquid support, a hydrophilic matrix, such as 2,5-dihydroxybenzoic acid (DHB), showed a substantial “peripheral effect,” in which good analyte ion signals could only be recorded at the peripheral region of the sample droplet. More hydrophobic matrices, such as α-cyano-4-hydroxycinnamic acid (α-CCA), exhibit better and more homogeneous responses at different regions of the droplets. The performance of these matrix solutions was evaluated in terms of the durability, reproducibility, sensitivity, high mass capability, and generality. A typical sample droplet can afford more than an hour of repeated sampling with excellent shot-to-shot reproducibility. A low picomole sensitivity was demonstrated using a luteinizing hormone releasing hormone (LHRH) in a Fourier transform ion cyclotron resonance mass spectrometer with a homemade external MALDI ion source. By using a commercial MALDI time-of-flight mass spectrometer, proteins with masses as high as 66,000 Da were successfully analyzed by using these matrix solutions.  相似文献   

5.
Due to the characteristic absorption peaks in the IR region, various molecules can be used as a matrix for infrared matrix‐assisted laser desorption/ionization (IR‐MALDI). Especially in the 6–7 µm‐band IR region, solvents used as the mobile phase for liquid chromatography have absorption peaks that correspond to their functional groups, such as O–H, CO, and CH3. Additionally, atmospheric pressure (AP) IR‐MALDI, which is applicable to liquid‐state samples, is a promising technique to directly analyze untreated samples. Herein we perform AP‐IR‐MALDI mass spectrometry of a peptide, angiotensin II, using a mid‐IR tunable laser with a tunable wavelength range of 5.50–10.00 µm and several different matrices. The wavelength dependences of the ion signal intensity of [M + H]+ of the peptide are measured using a conventional solid matrix, α‐cyano‐4‐hydroxycinnamic acid (CHCA) and a liquid matrix composed of CHCA and 3‐aminoquinoline. Other than the O–H stretching and bending vibration modes, the characteristic absorption peaks are useful for AP‐IR‐MALDI. Peptide ions are also observed from an aqueous solution of the peptide without an additional matrix, and the highest peak intensity of [M + H]+ is at 6.00 µm, which is somewhat shorter than the absorption peak wavelength of liquid water corresponding to the O–H bending vibration mode. Moreover, long‐lasting and stable ion signals are obtained from the aqueous solution. AP‐IR‐MALDI using a 6–7 µm‐band IR tunable laser and solvents as the matrix may provide a novel on‐line interface between liquid chromatography and mass spectrometry. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
Mechanistic arguments relative to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) address observations that predominately singly charged ions are detected. However, recently a matrix assisted laser ablation method, laserspray ionization (LSI), was introduced that can use the same sample preparation and laser as MALDI, but produce highly charged ions from proteins. In MALDI, ions are generated from neutral molecules by the photon energy provided to a matrix, while in LSI ions are produced inside a heated inlet tube linking atmospheric pressure and the first vacuum region of the mass spectrometer. Some LSI matrices also produce highly charged ions with MALDI ion sources operated at intermediate pressure or high vacuum. The operational similarity of LSI to MALDI, and the large difference in charge states observed by these methods, provides information of fundamental importance to proposed ionization mechanisms for LSI and MALDI. Here, we present data suggesting that the prompt and delayed ionization reported for vacuum MALDI are both fast processes relative to producing highly charged ions by LSI. The energy supplied to produce these charged clusters/droplets as well as their size and time available for desolvation are determining factors in the charge states of the ions observed. Further, charged droplets/clusters may be a common link for ionization of nonvolatile compounds by a variety of MS ionization methods, including MALDI and LSI.  相似文献   

7.
Atmospheric pressure (AP) matrix‐assisted laser desorption/ionization (MALDI) is known to suffer from poor ion transfer efficiencies as compared to conventional vacuum MALDI (vMALDI). To mitigate these issues, a new AP‐MALDI ion source utilizing a coaxial gas flow was developed. Nitrogen, helium, and sulfur hexafluoride were tested for their abilities as ion carriers for a standard peptide and small drug molecules. Nitrogen showed the best ion transport efficiency, with sensitivity gains of up to 1900% and 20% for a peptide standard when the target plate voltage was either continuous or pulsed, respectively. The addition of carrier gas not only entrained the ions efficiently but also deflected background species and declustered analyte–matrix adducts, resulting in higher absolute analyte signal intensities and greater signal‐to‐noise (S/N) ratios. With the increased sensitivity of pneumatically assisted (PA) AP‐MALDI, the limits of detection of angiotensin I were 20 or 3 fmols for continuous or pulsed target plate voltage, respectively. For analyzing low‐mass analytes, it was found that very low gas flow rates (0.3–0.6 l min?1) were preferable owing to increased fragmentation at higher gas flows. The analyte lability, type of gas, and nature of the extraction field between the target plate and mass spectrometer inlet were observed to be the most important factors affecting the performance of the in‐line PA‐AP‐MALDI ion source. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
A major problem hampering the use of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for quantitative measurements is the inhomogeneous distribution of analytes and matrices in solid sample preparations. The use of ionic liquids as matrices for the qualitative and quantitative analysis of low molecular weight compounds like amino acids, sugars and vitamins was investigated. The ionic liquid matrices are composed of equimolar combinations of classical MALDI matrices (sinapinic acid, alpha-cyano-4-hydroxycinnamic acid or 2,5-dihydroxybenzoic acid) with organic bases. These matrix systems allow a homogenous sample preparation with a thin ionic liquid layer having negligible vapour pressure. This leads to a facilitated qualitative and quantitative measurement of the analytes compared with classical solid matrices.  相似文献   

9.
The mean initial velocities of analyte ions ranging in molecular weight from 1000 Da to 150 kDa and desorbed with a pulsed Er:YAG laser from various solid-state and liquid IR MALDI matrices were measured along with those of the matrix ions. Experiments with UV MALDI were performed for comparison in addition for a 2,5-dihydroxybenzoic acid preparation. Two different measurement principles were employed, (1) a delayed extraction method, relying on the initial velocity-dependent increase of flight times with delay time between laser and HV ion extraction pulse, and (2) a field-free drift method in which the first region of a two-stage ion source was varied in length and the flight times compared. The two methods yielded somewhat different values for the mean initial ion velocities. Based on a detailed discussion of the measurement principles it is suggested that the actual initial velocities of IR MALDI ions lie between the limits set by the two methods. The influences of the analyte-to-matrix ratio, laser fluence, and laser wavelength on the initial ion velocities were also investigated. Significant differences between the desorption mechanisms for liquid and solid-state matrices were observed.  相似文献   

10.
Traditional matrix does not allow matrix-assisted laser desorption/ionization mass spectrometry(MALDI MS) to analyze volatile compounds,because volatile analytes may vaporize during the sample preparation process or in the high vacuum circumstance of ion source.Herein,we reported a Co and N doped porous carbon material(Co-NC) which were synthesized by pyrolysis of a Schiff base coordination compound.Co-NC could simultaneously act as adsorbent of volatile compounds and as matrix of MALDI MS,to provide the capability of MALDI MS to analyze volatile compounds.As adsorbent,Co-NC could stro ngly adsorb and enrich the volatile compounds in perfume and herbs,and hold them even in the high vacuum circumstance.On the other hand,Co-NC could absorb the energy of the laser,and then transfer the energy to the analyte for desorption and ionization of analyte in both negative and positive ionization modes.Additionally,the background interferences were avoided in the low-mass region(<500 Da) when using Co-NC as matrix,overcoming the challenges of MALDI MS analysis of small molecule compounds.In summary,Co-NC as matrix tremendously extended the application of MALDI MS.  相似文献   

11.
Tong H  Sze N  Thomson B  Nacson S  Pawliszyn J 《The Analyst》2002,127(9):1207-1210
Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.  相似文献   

12.
An atmospheric pressure (AP) infrared (IR) laser ionization technique, implemented on a quadrupole ion trap mass spectrometer, was used to analyze underivatized, N-linked oligosaccharides in solution. Experiments were conducted on an atmospheric pressure infrared ionization from solution (AP-IRIS) ion source which differed from previous AP IR matrix-assisted laser desorption/ionization (MALDI) interfaces in that the ion source operated in the absence of an extraction electric field with a higher power 2.94 microm IR laser. The general term 'IRIS' is used as the mechanism of ionization differs from that of MALDI, and is yet to be fully elucidated. The AP-IRIS ion source demonstrated femtomole-level sensitivity for branched oligosaccharides. AP-IRIS showed approximately 16 times improved sensitivity for oligomannose-6 and the core-fucosylated glycan M3N2F over optimal results obtainable on a AP UV-MALDI with a 2,4,6-trihydroxyacetophenone matrix. Comparison between IR and UV cases also showed less fragmentation in the IR spectrum for a glycan with a conserved trimannosyl core, core-substituted with fucose. A mixture of complex, high-mannose and sialylated glycans resulted in positive ion mass spectra with molecular ion peaks for each sugar. Tandem mass spectrometry of the sodiated molecular ions in a mixture of glycans revealed primarily glycosidic (B, Y) cleavages. The reported results show the practical utility of AP-IRIS while the ionization mechanism is still under investigation.  相似文献   

13.
The need of cellular and sub‐cellular spatial resolution in laser desorption ionization (LDI)/matrix‐assisted LDI (MALDI) imaging mass spectrometry (IMS) necessitates micron and sub‐micron laser spot sizes at biologically relevant sensitivities, introducing significant challenges for MS technology. To this end, we have developed a transmission geometry vacuum ion source that allows the laser beam to irradiate the back side of the sample. This arrangement obviates the mechanical/ion optic complications in the source by completely separating the optical lens and ion optic structures. We have experimentally demonstrated the viability of transmission geometry MALDI MS for imaging biological tissues and cells with sub‐cellular spatial resolution. Furthermore, we demonstrate that in conjunction with new sample preparation protocols, the sensitivity of this instrument is sufficient to obtain molecular images at sub‐micron spatial resolution. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Atmospheric pressure matrix‐assisted laser desorption/ionization (AP‐MALDI) has proven a convenient and rapid method for ion production in the mass spectrometric (MS) analysis of biomolecules. AP‐MALDI and electrospray ionization (ESI) sources are easily interchangeable in most mass spectrometers. However, AP‐MALDI suffers from less‐than‐optimal sensitivity due to ion losses during transport from the atmosphere into the vacuum of the mass spectrometer. Here, we study the signal‐to‐noise ratio (S/N) gains observed when an on‐chip dynamic pre‐concentration/focusing approach is coupled to AP‐MALDI for the MS analysis of neuropeptides and protein digests. It was found that, in comparison with conventional AP‐MALDI targets, focusing targets showed (1) a sensitivity enhancement of approximately two orders of magnitude with S/N gains of 200–900 for hydrophobic substrates, and 150–400 for weak cation‐exchange (WCX) substrates; (2) improved detection limits as low as 5 fmol/µL for standard peptides; (3) significantly reduced matrix background; and (4) higher inter‐day reproducibility. The improved sensitivity allowed successful tandem mass spectrometric (MS/MS) sequencing of dilute solutions of a derivatized tryptic digest of a protein standard, and enabled the first reported AP‐MALDI MS detection of neuropeptides from Aedes aegypti mosquito heads. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
Matrix-enhanced surface-assisted laser desorption ionization mass spectrometry imaging (ME-SALDI MSI) has been previously demonstrated as a viable approach to improving MS imaging sensitivity. We describe here the employment of ionic matrices to replace conventional MALDI matrices as the coating layer with the aims of reducing analyte redistribution during sample preparation and improving matrix vacuum stability during imaging. In this study, CHCA/ANI (α-cyano-4-hydroxycinnamic acid/aniline) was deposited atop tissue samples through sublimation to eliminate redistribution of analytes of interest on the tissue surface. The resulting film was visually homogeneous under an optical microscope. Excellent vacuum stability of the ionic matrix was quantitatively compared with the conventional matrix. The subsequently improved ionization efficiency of the analytes over traditional MALDI was demonstrated. The benefits of using the ionic matrix in MS imaging were apparent in the analysis of garlic tissue sections in the ME-SALDI MSI mode.  相似文献   

16.
The mass spectra of peptides obtained with different matrices were compared using a matrix-assisted laser desorption/ionization (MALDI) ion source and a multi-turn time-of-flight (TOF) mass spectrometer, MULTUM-IMG, which has been developed at Osaka University. Two types of solid matrices, alpha-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB), and a liquid matrix made from a mixture of 3-aminoquinoline and CHCA were used. When measuring the peak signal intensity of human angiotensin II [M+H]+ from a fixed sample position, the liquid matrix produced a stable signal over 1000 laser shots, while the signal obtained with CHCA and DHB decayed after about 300 and 100 shots, respectively. Significant differences in the mass resolving power were not observed between the spectra obtained with the three matrices. Signal peak areas were measured as a function of the cycle number in a multi-turn ion trajectory, i.e., the total flight time over a millisecond time scale. For both [M+H]+ of human angiotensin II and bovine insulin, the decay of the signal peak area was the most significant with CHCA, while that measured with DHB was the smallest. The results of the mean initial ion velocity measurements suggested that the extent of metastable decomposition of the analyte ions increased in order of DHB, the liquid matrix, and CHCA, which is consistent with the difference in the decay of the signal peak area as the total flight time increased.  相似文献   

17.
For matrix‐assisted laser desorption/ionization (MALDI) mass spectra, undesirable ion contamination can occur due to the direct laser excitation of substrate materials (i.e., laser desorption/ionization (LDI)) if the samples do not completely cover the substrate surfaces. In this study, comparison is made of LDI processes on substrates of indium and silver, which easily emit their own ions upon laser irradiation, and conventional materials, stainless steel and gold. A simultaneous decrease of ion intensities with the number of laser pulses is observed as a common feature. By the application of an indium substrate to the MALDI mass spectrometry of alkali salts and alkylammonium salts mixed with matrices, 2,5‐dihydroxybenzoic acid (DHB) or N‐(4‐methoxybenzylidene)‐4‐butylaniline (MBBA), the mixing of LDI processes can be detected by the presence of indium ions in the mass spectra. This method has also been found to be useful for investigating the intrinsic properties of the MALDI matrices: DHB samples show an increase in the abundance of fragment ions of matrix molecules and cesium ions with the number of laser pulses irradiating the same sample spot; MBBA samples reveal a decrease in the level of background noise with an increase in the thickness of the sample layer. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
This article presents a comparative study of the performance, operational, and instrumental characteristics of AP and vacuum MALDI for the analysis of peptides and protein digests. Spectra generated with the two ion sources were surprisingly similar, both qualitatively and quantitatively, with vacuum MALDI generating ion count rates that were approximately a factor of 2 greater than those generated with AP MALDI on this system. Even though the peptide signals were 2X greater with vacuum MALDI, the background intensities also increased by a similar amount, leading to approximately equivalent signal/background ratios for digests and peptide mixtures. The results suggest that when AP MALDI conditions are properly optimized, the sensitivity can approach that of vacuum MALDI. However, AP MALDI performance is critically affected by source gas flows, potentials, and temperature, making it operationally more complex. In addition, evidence is provided for thermal degradation of samples stored on a target plate within a heated AP MALDI ion source. An improved interface for atmosphere to vacuum ion transfer substantially improved these characteristics.  相似文献   

19.
Controlled in-source ion-molecule reactions are performed for the first time in an external matrix assisted laser desorption ionization (MALDI) source of a Fourier transform ion cyclotron resonance mass spectrometer. The MALDI source with a hexapole ion guide that was originally designed to incorporate pulsed gas to collisionally cool ions (Baykut, G.; Jertz, R.; Witt, M. Rapid Commun. Mass Spectrom. 2000, 14, 1238-1247) has been modified to allow the study of in-source ion-molecule reactions. Upon laser desorption, a reaction gas was introduced through a second inlet and allowed to interact with the MALDI-generated ions trapped in the hexapole ion guide. Performing ion-molecule reactions in the high pressure range of the ion source prior to analysis in the ion cyclotron resonance (ICR) cell allows to maintain the ultra high vacuum in the cell which is crucial for high mass resolution measurements. In addition, due to the reaction gas pressure in the hexapole product ion formation is much faster than would be otherwise possible in the ICR cell. H/D exchange reactions with different peptides are investigated, as are proton-bound complex formations. A typical experimental sequence would be ion accumulation in the hexapole ion guide from multiple laser shots, addition of cooling gas during ion formation, addition of reaction gas, varied time delays for the ion-molecule reactions, and transmission of the product ions into the ICR cell for mass analysis. In this MALDI source H/D exchange reactions for different protonated peptides are investigated, as well as proton-bound complex formations with the reaction gas triethylamine. Amino acid sequence, structural flexibility and folding state of the peptides can be seen to play a part in the reactivity of such ions.  相似文献   

20.
The development of reliable sample preparation methods has been critical to the success of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry experiments. Good MALDI sample preparation for polymers involves choosing the solvent system, the matrix, and the ionization agent correctly, and combining them in a manner that will lead to a sample that will produce the desired ions. The vast diversity of chemistry available in industrial polymers has challenged our ability to design reliable sample preparation methods. In the experiments reported here, we show that matrix-enhanced secondary ion mass spectrometry (MESIMS) is an effective analytical technique to explore sample segregation in solid phase MALDI samples. Qualitative comparison of MESIMS and MALDI results for polymer samples prepared with multiple matrices aids our investigation of the solid-phase solubility of a variety of low molecular weight polymer materials. Including the solid-phase solubility with the liquid-phase solubility of the polymer samples and the matrices enables the construction of a relative solubility chart, which shows the best solubility matches between the polymer and matrix materials for MALDI experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号