1.
2.
A rapid and reliable method is presented for the determination of the preservatives sodium benzoate and potassium sorbate in fruit juices, sodas, soy sauce, ketchup, peanut butter, cream cheese, and other foods. The procedure utilizes high-performance liquid chromatography (HPLC) followed by UV diode array detection for identification and quantitation of the two preservatives. Liquid samples were prepared by diluting 1 ml of the sample with 10 ml of an acetonitrile/ammonium acetate buffer solution. Samples of viscous or solid foods were prepared by blending the sample with the same buffer solution in a 1:5 ratio followed by a dilution identical to liquid samples. All samples were filtered to remove particulate matter prior to analysis. The HPLC determination of the preservatives was performed using a reversed-phase C18 column and UV detection at 225 nm for sodium benzoate and 255 nm potassium sorbate. The percentage of preservative in the sample was calculated by external standard using authentic sodium benzoate and potassium sorbate. Apple juice, apple sauce, soy sauce, and peanut butter, spiked at 0.10 and 0.050% for both sodium benzoate and potassium sorbate, yielded recoveries ranging from 82 to 96%. The method can detect 0.0010% (10 mg/l) of either preservative in a juice matrix.  相似文献   

3.
4.
5.
6.
Ganciclovir is a nucleoside analogue widely used in the treatment of cytomegalovirus infections, which affects mainly immunocompromised patients. Recently, new pharmaceutical dosage forms based on the use of albumin nanoparticles have been developed for improving the efficacy of this drug. The aim of this study was to develop an analytical HPLC method for the determination of ganciclovir in both pharmaceuticals (i.e. albumin nanoparticles) and biological medium samples. The chromatography was performed on a reversed-phase encapped column (LiChrospher Select B C8) with a mobile phase consisting of acetonitrile in 0.05 M ammonium acetate (pH 6.5; 2: 98, v/v). Acyclovir was used as internal standard and the detection wavelength was 254 nm. The limit of quantitation of ganciclovir was 50 ng/ml and the average recoveries over a concentration range of 0.05–10 μg/ml ranged from 98 to 102%. Precision did not exceed 5%. In summary, this assay is a selective, sensitive and reproducible method for the determination of the ganciclovir in albumin nanoparticles. It can be successfully applied to the estimation of the ganciclovir uptake by cultured human corneal fibroblasts.  相似文献   

7.
A reliable and simple method for the routine analysis of pharmaceutical dosage forms by high-performance liquid chromatography using a C18 Bondapak reversed-phase column with a binary solvent system consisting of acetonitrile and 0.05 M potassium dihydrogen phosphate has been developed. Standardised extraction procedures for drugs in various dosage forms have been developed and successfully applied to a wide range of current pharmaceutical formulations.  相似文献   

8.
Fructus Psoraleae, a widely used traditional Chinese medicine, is well known as a health supplement ingredient. In our study, an improved and comprehensive HPLC fingerprint of Fructus Psoraleae was established. Two important new benzofuran glycosides, psoralenoside and isopsoralenoside, were identified as characteristic constituents for the first time. HPLC separation was performed on an RP-C8 column. The mobile phase was acetonitrile and 0.1% acetic acid solution with linear gradient change of acetonitrile from 10 to 82% in 40 min. The flow rate was 1.0 mL/min, and the detection wavelength was set at 310 nm. The HPLC chromatograms of twenty-six samples from different regions of China showed a similar pattern. Twelve peaks were selected as characteristic peaks and further identified as psoralenoside, isopsoralenoside, psoralen, isopsoralen, bavachromene, corylifolin, corylin, psoralidin, isobavachalcone, bavachinin, corylifol A, and bakuchiol, respectively. Nine of them were simultaneously quantitatively analyzed for the first time. A more comprehensive analytical method was established for the fingerprint of Fructus Psoraleae. It is very useful for authentication and quality assessment of the crude drug.  相似文献   

9.
高效液相色谱法测定粮食制品中甲醛残留量   总被引:20,自引:0,他引:20  
研究建立了一种用HPLC测定粮食制品中甲醛残留量的分析方法。样品中甲醛经60℃水浴提取,与2,4 二硝基苯肼衍生后,生成的2,4 二硝基苯腙经石油醚萃取净化,用HPLC DAD分离测定,外标法定量。最小检出质量浓度为5×10-11g,对于5g样品,最低检出量为0.01mg kg,样品回收率>80%,相对标准偏差≤10%,能满足残留量分析的要求。  相似文献   

10.
11.
Grapefruits were found to contain D-glucaric acid, which has anticancer properties. In the present investigation, a method has been developed for the quantification of D-glucaric acid in grapefruit by high-performance liquid chromatography (HPLC) using a simple isocratic mobile phase with detection at 210 nm. Grapefruit samples were homogenized, centrifuged and filtered through a 0.45 microm membrane and injected into a HPLC system. The developed method was used for the quantification of D-glucaric acid in nine widely used grapefruit varieties. Furthermore, the identity of D-glucaric acid was confirmed by mass spectra. Seasonal variation of D-glucaric acid within the individual varieties were also measured in fruits harvested during November, February and May. The overall trend of D-glucaric acid level was increased from early to late season fruits. The developed method has a sensitivity of D-glucaric acid as low as 0.05 microg with an accuracy and precision >95%. This method was found to be simple, fast, accurate and reproducible. Moreover, the identity of D-glucaric acid was confirmed by mass spectra. Additionally, the labor intensity and cost of sample preparation were greatly reduced as compared to reported methods. This is the first report on quantification of D-glucaric acid in different varieties of grapefruits from three harvesting sessions.  相似文献   

12.
We have developed miniaturized multi-channel high-performance liquid chromatography (HPLC) system. With this system, we can simultaneously separate multiple samples, using a single high-pressure gradient pump, a chip-based sample injection unit, a monolithic silica capillary column array, and a multi-channel UV detection unit based on fiber optics. The injection unit has a simplified structure composed of brass housing and a quartz microchip having microchannels and access ports, which enable a direct injection of sample to multi-channel by commercial multichannel micropipette. Moreover, that possesses a function of microvalve, and on-chip definition of sample injection plugs achieved with a cross channel injection method, providing each column of monolithic silica capillary array. The substances in channels were simultaneously detected with UV having multiple cells. Standard samples were analyzed for characterizing newly developed system, and sharp peaks were obtained with reproducibility data of < 0.9% (R.S.D.). Analysis of tryptic digestion of casein was also employed. These results show that the novel multi-channel HPLC system has the benefits for the high-throughput analysis in the post-genomic analysis/combinatorial chemistry.  相似文献   

13.
A reversed-phase HPLC method has been developed which enables separation of the three components of a closed-loop insulin delivery system, namely concanavalin A methacrylamide (Con A-MA), dextran methacrylate (Dex-MA) and bovine insulin. The analysis of Con A-MA represents a significant challenge due to the formation of multiple conformations on contact with the chromatographic surface and the mobile phase. The extent of conformational change is shown to be dependent on a number of parameters: column temperature, mobile phase pH, contact time with the chromatographic surface, salt type and concentration and the organic modifier. By manipulation of these variables, protein denaturation can be minimised and recovery improved.  相似文献   

14.
A highly sensitive and simple method for determining delta-aminolevulinic acid (ALA) in urine was established, using direct injection of urine into a high-performance liquid chromatographic column, with fluorometric detection after post-column derivatization with o-phthalaldehyde (OPA). The recovery of ALA was about 100% and ALA was completely separated on an ion exchange column (retention time, 38 min). The detection limit for ALA was 10 pmol (S/N = 2). The mean levels of urinary ALA of 10 healthy volunteers, 4 patients with acute intermittent porphyria, and 2 workers occupationally exposed to lead were 0.76, 5.25, and 23.54 mg/l, respectively. Because of its simplicity, the method is considered to be suitable for routine analysis of urinary ALA in the clinical laboratory.  相似文献   

15.
A rapid and selective HPLC method using monolithic columns was developed for the separation and quantification of the principal amphetamines in ecstasy tablets. Three monolithic (Chromolith RP18e) columns of different lengths (25, 50 and 100 mm) were assessed. Validation studies including linearity, selectivity, precision, accuracy and limit of detection and quantification were carried out using the Chromolith SpeedROD, RP-18e, 50 mm x 4.6 mm column. Column backpressure and van Deemter plots demonstrated that monolithic columns provide higher efficiency at higher flow rates when compared to particulate columns without the loss of peak resolution. Application of the monolithic column to a large number of ecstasy tablets seized in Ireland ensured its suitability for the routine analysis of ecstasy tablets.  相似文献   

16.
17.
A simple and sensitive high-performance liquid chromatographic method is described for the quantitative analysis of ciprofloxacin in pharmaceuticals and human plasma. The method employs reversed-phase chromatography using an RP-C18 column with an isocratic mobile phase of acetonitrile-2% acetic acid aqueous solution (16:84, v/v), umbelliferone as an internal standard, and a flow rate of 1.0 mL/min. The UV detector is set at 280 nm. The limit of detection is 0.25 microM (S/N = 3, injection volume = 10 microL). The regression equations are linear (r > 0.9999) over a range between 0.51 approximately 130 microM for the pharmaceutical analysis of ciprofloxacin and 0.51 approximately 64.8 microM for the biological analysis of ciprofloxacin in human plasma. The intra- and inter-day relative standard deviation and relative error are less than 3.39% and 5.71%, respectively. All the recoveries are greater than 93.8%. This method is successfully applied in a pharmacokinetic study of a volunteer who receives a 500 mg ciprofloxacin tablet.  相似文献   

18.
N. Mellor 《Chromatographia》1982,16(1):359-363
Summary Many analysts are not taking full advantage of the high speed possibilities of modern LC. Some analytical procedures reported in the literature, and many in regular use in control laboratories, could be achieved in less time without loss in precision. Some factors which affect retention times are discussed and the advantages and disadvantages of employing shorter column lengths and finer packing materials in reversed-phase HPLC are examined. The effect on efficiency of increased flow rates with 10,5 and 3 m ODS materials is shown. The ability to couple shorter column lengths without loss of efficiency is also demonstrated. This allows a minimum length to be selected that gives adequate resolution. Examples of high speed separations are shown and limitations in state of the art HPLC equipment and chromatographic data systems are discussed briefly.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

19.
The objective was to develop a simple HPLC method to quantify exenatide—a 39 amino acid residue incretin mimetic used in diabetes therapy. To date, only non‐validated, sometimes incomplete, gradient methods have been reported in the literature. Isocratic separation was achieved using a C4 column and a mixed solvent system, A–B–C (48:45:7, v/v/v; pH* 5.2), where A represents KH2PO4 (pH 4.5; 0.1 m ) and MeCN (60:40, v/v), B corresponds to NaClO4·H2O (pH 6.0; 0.2 m ) and MeCN (60:40, v/v), and C is water. Exenatide eluted at 3.64 min and the total run time was 6 min. The method was specific and the response was accurate, precise and linear from 0.75 to 25 µg/mL. It was used to quantify exenatide transport across intact and laser‐porated porcine skin in vitro as a function of laser fluence [0 (i.e. intact skin), 9 and 15 J/cm2, respectively]. Although no permeation was observed using intact skin, cumulative exenatide permeation after 8 h through laser porated skin was 9.6 ± 6.5 and 12.4 ± 6.4 µg/cm2 at fluences of 9 and 15 J/cm2, respectively. This is the first validated isocratic method for exenatide quantification and it may be of use in quality control analysis and with other biological matrices. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
para-Aminobenzoic acid (PABA), a precursor in the synthesis of folates in plants, is determined by liquid chromatography/tandem mass spectrometry (LC/MS/MS). In plants PABA can be converted into its beta-D-glucopyranosyl ester (PABA-Glc) and can also exist in its free form. In this work, we developed and validated a quantitative method to study free and total PABA in plants. The total PABA (free PABA plus PABA-Glc) can be evaluated after acid hydrolysis at 80 degrees C for 2 hours. The plant material is homogenized and the PABA content is quantified using the standard addition procedure. The validated method is selective, sensitive, simple, accurate, has a recovery between 99.6 to 102.5%, is reproducible (RSD between 1.4 and 4.4%), and is linear between 2.5 and 1538 ng/mL. Free and total PABA determinations in five vegetables showed that different plant species had different amounts of free and total PABA, and that the ratios of total versus free PABA were also variable. This new method could be valuable for studies of folate synthesis in plants.  相似文献   