首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A room-temperature flow injection spectrofluorimetric method is presented for the determination of Zn(II), based on the use of salicylaldehyde thiocarbohydrazone in the presence of Triton X-100 and sodium acetate-acetic acid buffer. Various physical and chemical variables affecting the reaction in the flow system were evaluated. The proposed method is very selective. The calibration graph is linear over the range 10–1000 ng/ml, with a detection limit of 5 ng/ml and a relative standard deviation at the 50 ng/ml level of 1.8 %. The method was successfully applied to the determination of Zn(II) in drinking waters and biological samples.  相似文献   

2.
A new method for the spectrofluorimetric determination of zinc with 8-(p-toluene- sulphonamido)quinoline in a Brij-35 micellar medium has been developed. This method allows the determination of 8-550 ng/ml Zn(II) and is relatively free from interferences. It has been applied to food samples with satisfactory results.  相似文献   

3.
Chang X  Su Z  Luo X  Zhan G 《Talanta》1993,40(4):527-532
A poly(acrylamidrazone-hydrazide) chelating fiber has been synthesized from polyacrylonitrile fiber and used for enrichment-separation of traces of In(III), Sn(IV), Cr(III), VO(I) and Ti(IV) from solution samples with satisfactory results. These ions (5-250 ng/ml) can be quantitatively enriched (recovery > 95%) by the fiber at a 10 ml/min flow rate in the pH range 4-7, and desorbed quantitatively (recovery > 95%) with 10 ml of 2-5M hydrochloric acid from a fiber column at 6 ml/min flow rate. When the fiber, which had been stored in a glass bottle for about two years and then treated with strong acids (concentrated hydrochloric or nitric acid), was reused 10 times, the recoveries of the above ions by enrichment were still over 94%, and hundred-fold to thousand-fold excesses of Cu(II), Zn(II), Co(II), Ca(II), Mg(II), Fe(III) and Al(III) caused little interference in the determination of these ions by ICP-AES. The lowest concentrations for the proposed method were 50 ng/ml and In and Sn and 5 ng/ml for Cr, V and Ti. The RSD was 1.2-4.0%. The contents of these ions in real solution samples determined by this method were basically in agreement with the certified values of the samples, with average errors below 3.3%. The IR spectra of the fiber adsorbed with Cr(III) or VO(I) showed that Cr(III) or VO(I) combined mainly with nitrogen atoms in the fiber to form a coordination complex.  相似文献   

4.
将SHA无机离子交换剂应用于在线预浓集FIA—AAS系统中,对痕量Cd、Zn、Fe的测定进行了研究。三个元素的检出限分别为0.1ng/ml,0.3ng/ml,0.6ng/ml。相对标准偏差小于3%(定时进样)和5%(定量进样).用标准物分析和回收实验评价了方法的准确度.对各种实际水样的测定结果今人满意。  相似文献   

5.
《Analytical letters》2012,45(14):2611-2623
Abstract

A new epoxy-urea chelating resin was synthesized from epoxy resin and used for the preconcentration and separation of trace Bi(III), In(III), Sn(IV), Zr(IV), V(V) and Ti(IV) ions from solution samples. The analyzed ions can be enriched at pH 5 at a flow rate of 1–4 ml/min, and can be also desorbed with 10 mL of 2 M HCl +0.1g NH4F solution from the resin column, with recoveries over 97%. The chelating resin reused 6 times can still adsorb quantitatively the Bi, In, Sn, Zr, V and Ti ions, and eighty to thousand-fold excesses of Ca(II), Mg(II), Cu(II), Zn(II), Al(III), Sb(III), Ni(II), Mn(II) and Fe(III) cause little interference with the enrichment and determination of these ions. The RSDs of the proposed method for the determination of 500–50 ng/ml Bi, In and Sn, 50–5.0 ng/ml Zr, V and Ti were in the range of 0.4 ~ 4.0%, the enrichment factor of the resin for the ions is in the range of 10–100. The recoveries of added standard in waste water are between 96% and 100%, and the concentration of each ion in alloy steel sample determined by the method is in good agreement with the reference value analyzed by a steel plant with average error <2.8%.  相似文献   

6.
《Analytical letters》2012,45(1):153-166
Abstract

The use of 1,5-bis(di-2-pyridylmethylene) thiocarbono-hydrazide as a reagent for the extraction of Ni(II), Co(II), Zn(II), Fe(II), Cd(II) and Cu(II) into methyl isobutyl ketone has been studied, and a method for the determination of nickel at ultra-trace (ng/ml) level has been developed, by using electrothermal-atomization (graphite furnace) atomic absorption spectrometry involving a prior extraction with the cited extracting reagent. The chief advantage of the proposed method lies in its maximum allowed aqueous-to-organic phase volume ratio of 15. It has been successfully applied to the determination of nickel substrates in various biological samples.  相似文献   

7.
本文提出了在乙二胺和乙二胺-盐酸体系中以计时电位溶出法测定Fe、Mn及以电位溶出法测定Cu、Pb、Cd、Zn的新方法。各元素的浓度在Fe 0.1~2600 ng/ml、Mn0.05~3200 ng/ml、Cu0.2~2800 ng/ml、Pb0.1~3600ng/ml、Cd 0.05~1200 ng/ml、Zn0.2~4200ng/ml时,浓度与溶出峰高呈良好的线性关系。本方法应用于水质及生物样品中上述各元素的测定,结果良好。  相似文献   

8.
The addition of thiol compounds to the fluorescence system of Zn(II)-8-hydroxyquinoline-5-sulphonic acid complex (Zn(II)-HQS) in H3BO3-Na2B4O7 buffer (pH 8.50) solution led to immediate fluorescence inhibition, which was proportional to their amounts. Based on this finding, a novel spectrofluorimetric method for the determination of cysteine (Cys) and reduced glutathione (GSH) has been developed. The detection limits were 17 ng ml(-1) and 0.6 microg ml(-1), respectively. Most amino acids had no interference at high concentrations. The proposed method has been applied to the determination of Cys in protein hydrolysate and cystine electrolyte, and GSH in human blood serum with recoveries of 95.6-104.5%.  相似文献   

9.
《Analytical letters》2012,45(13):2217-2230
Abstract

(Acetylacetone)‐2‐thiol‐phenyleneimine (H2L) immobilized on an anion‐exchange resin (Dowex) was used for separation and removal of mercury from natural water samples and for preconcentration prior to its determination by cold vapor inductively coupled plasma atomic emission spectroscopy. The metal was eluted from the column using a solution of 10% thiourea in 0.1 M HCl. The modified resin is higly selective with an exchange capacity of 1.60 mmol g?1. Various parameters like pH, column flow rate, and desorbing agents are optimized. The proposed method has a linear calibration range of 15–1000 ng/ml Hg(II), with a relative standard deviation at the 15 ng/ml level of 3.5%. The precision of the method (evaluated as the relative standard deviation obtained after analyzing six series of five replicates) was ±4.2% at the 50 ng/ml level of Hg(II). The method has been used for routine determination of trace levels of mercury species in natural waters. The potential application of modified resin for the removal of mercury(II) from two natural water samples (top water and lake water) spiked with 50 ng/ml of mercury (II) was studied by ICP‐AES, and the results proved that excellent percent extraction of mercury(II) from both natural water samples was obtained by column method using modified resin.  相似文献   

10.
A sensitive fluorescence optosensing method for the determination of Hg(II) in water samples is described. The method, using a flow injection technique, is based on the immobilization on a non-ionic-exchanger solid support (packed in a flow cell placed in a conventional fluorimeter) of the thiochrome formed by the oxidation of thiamine with Hg(II) in a continuous flow carrier at pH 8.1. Experimental parameters such as the solid support, the carrier pH, the thiamine concentration and the flow-rate were investigated to select the optimum operating conditions. The proposed optosensor showed a relative standard deviation of + 3.0% for ten replicates analysis of 100 ng ml(-1) of mercury(II). A detection limit of 3 ng ml(-1) for mercury(II) was achieved for 4-ml sample injections. A detailed study of interferences (possible elements present in natural waters) demonstrated that this optosensing method is virtually specific for this metal, because it allows the determination of mercury in the presence of relatively large amounts of other heavy metals and compounds present in natural waters, such as Mg(II) or Ca(II). The method was successfully applied to the determination of Hg(II) in spiked samples of mineral, tap and sea water.  相似文献   

11.
A selective and sensitive method for the determination of cadmium and zinc is presented. The method is based on the adsorptive accumulation of the complexes of Cd(II) and Zn(II) ions with 4-amiono-5-methyl-2.4-dihydro-3H-1,2,4-triazol-3-tion (MMTT) onto hanging mercury drop electrode (HMDE), followed by the reduction of the adsorbed species using a voltammetric scan using differential pulse modulation. The ligand concentration, pH, potential and time of accumulation, scan rate, and pulse height were optimized. Under the optimized conditions, a linear calibration curve was obtained for the concentration of Cd(II) and Zn(II) in the range of 5–450 and 5–850 ng/mL, respectively, with a detection limit of 1.7 ng/mL Cd(II) and 1.3 ng/mL Zn(II). The ability of the method was evaluated by analysis of cadmium and zinc in water and alloy samples The text was submitted by the authors in English.  相似文献   

12.
四元缔合物体系薄层树脂相分离与光度法联用测定痕量钴   总被引:2,自引:0,他引:2  
提出了在酸性条件下 (pH=5.0),利用阳离子交换树脂-丁二酮肟-碘-钴四元体系,通过薄层树脂相光度法测定钴的新方法。本法灵敏度高 (e454=1.7105L/molcm),比水相光度法提高14倍,精密度理想 (测定2.0礸/ml Co(II) 6次,RSD=1.3%),选择性好。实测药品VB12及天然水中钴,线性范围0.024~2.0礸/ml (定容50ml),检出限10.4ng/ml。  相似文献   

13.
Gong B  Li X  Wang F  Chang X 《Talanta》2000,52(2):217-223
A novel spherical macroporous epoxy-dicyandiamide chelating resin is synthesized simply and rapidly from epoxy resin and use for the preconcentration and separation of trace Ga(III), In(III), Bi(III), Sn(IV), Pb(II), V(V) and Ti(IV) ions from solution samples. The analyzed ions can be quantitatively concentrated by the resin at flow rate of 3.0 ml min(-1) at pH 3, and can also be desorbed with 10 ml of 4 M HCl+0.2 g thiourea from the resin column with recoveries of 97-100%. The chelating resin is reused for eight times, the recoveries of these ions are still over 92%, and a 100-1000 times of excess of Fe(III), Al(III),Ca(II), Mg(III), Ni(II), Mn(II), Co(II), Cu(II), Zn(II), and Cd(II) cause no interference in the determination of these ions by inductively-coupled plasma atomic emission spectrometry. The capacities of the resin for the analytes are in the range of 0.66-4.20 mmol g(-1). The results show the relative standard deviation for the determination of 50.0 ng ml(-1) Ga(III), In(III), Bi(III), Sn(IV) and Pb(II), 5.0 ng ml(-1) V(V) and Ti(IV) are in the range of 1.2-4.0%. The recoveries of a standard added in real solution samples are between 96 and 100%, and the concentration of each ion in mineral sample detected by the method is in good agreement with the certified value.  相似文献   

14.
A flow injection-photometric method has been developed for the determination of iron(II+III). The method is based on the catalytic effect of iron(III) on the hydrogen peroxide oxidation of 3,3',5,5'-tetramethylbenzidine to form a blue compound (lambda(max)=650 nm). In this catalyzed reaction, 1,10-phenanthroline acted as an effective activator. Iron(II) is also determined, being oxidized by hydrogen peroxide. Calibration graphs for iron(II) and iron(III) obtained under the optimized conditions were identical with each other and linear in the range 0.2-200 ng ml(-1) with a detection limit of 0.05 ng ml(-1) iron. The reproducibility was satisfactory with a relative S.D. of 1.0% for ten determinations of 5 ng ml(-1) iron(III). The proposed method was successfully applied to the determination of iron in river and lake water samples and can be determined free iron species.  相似文献   

15.
《Analytical letters》2012,45(8):1591-1601
ABSTRACT

A simple, sensitive and selective method is proposed for the determination of copper(II) by adsorption-differential pulse stripping method. This method is based on the selective accumulation of the complexes of Cu(II) with l-(2-pyridylazo)-2-Naphthol and then reduction of the complex on a HMDE. The reduction current of the complex is about 0.0V vs. Ag/AgCl reference electrode at p8543146=4.0. The influences of various experimental parameters on the current peak were completely studied. The calibration graph was linear up to 50.0 ng/ml for a deposition time of 60 sec. The relative standard deviation was 2.3% (n=5) for Cu(II) concentration of 10.0 ng/ml, with a limit of detection of 0.2 ng/ml. The influence of potentially interfering ions was completely studied. The method has been applied for the determination of Cu(II) in water samples.  相似文献   

16.
Müller H  Schurig H  Werner G 《Talanta》1974,21(6):581-589
The application of the catalysed oxidation of Bromopyrogallol Red by potassium per- sulphate for silver determination is discussed. In aqueous solution silver concentrations of 0.5- 1 mug/ml can be determined and 1- 13 ng/ml in the presence of 1, 10-phenanthroline as activator. In combination with solvent extraction, catalytic determination of the extracted silver is possible even in presence of 200 mug of iron(III), cobalt(II) and palladium(II). By means of an automatic variant of the simultaneous comparison method a more sensitive determination (0.2-20 ng/ml) was achieved.  相似文献   

17.
A chemiluminescence (CL) method using flow injection (FI) has been investigated for the rapid and sensitive determination of enalapril maleate. The method is based on the CL reaction of the drug with tris(2,2'-bipyridyl)ruthenium(II), Ru(bipy)3(2+) and acidic potassium permanganate. After selecting the best operating parameters, calibration graphs were obtained over concentration ranges of 0.005-0.2 microg/ml and 0.7-100 microg/ml with a detection limit (S/N=2) of 1.0 ng/ml. The average % found was 99.9 +/- 0.7 and 100.2 +/- 0.3 for the two concentration ranges respectively. %RSD (n=10) for 5.0 microg/ml was 0.44. The method was successfully applied to the determination of enalapril maleate in dosage forms and biological fluids without interferences.  相似文献   

18.
A semi-automatic continuous method for the determination of Se(IV) based on flow-injection cathodic stripping voltammetry (FICSV) is reported. The flow injection approach incorporates a thin mercury film on glassy carbon as the working electrode, on which Se(IV) is deposited at an applied potential of 0.0 V. A cathodic scan (from 0.0 to –0.9 V) is applied and the Se is stripped at –0.54 V, providing a current intensity proportional to the Se(IV) concentration in the sample. This method features a linear determination range between 0.5 and 30 ng/ml (r2=0.998, RSD=3.6%). The non-interference levels (foreign species to analyte ratio) are 2.5:1 for Cu(II), 7.5:1 for Pb(II), 35:1 for Cd(II), 250:1 for Zn(II) and 500:1 for Fe(III). After developing the method for Se(IV), the speciation of this element has been performed by sequential injection of the dissolved sample into a carrier which may or may not have been previously reduced off-line thus determining the sum (Se(IV)+Se(VI)) or only Se(IV), respectively. The method has been applied to selenium speciation in water samples.  相似文献   

19.
The reaction of aluminium(III) with Hydroxynaphtol Blue (HNB) in aqueous media at apparent pH 5.5 results in a red complex that is stable for at least 4 hr. Beer's Law is obeyed up to 1.6 microg/ml of aluminium(III) with an apparent molar absorptivity of 1.66 x 10(4) l.mol(-1). cm(-1) at 569 nm. This paper proposes procedures for aluminium(III) determination by ordinary and first-derivative spectrophotometry. The results demonstrated that the linear dynamic range is 0.03-1.60 microg/ml for ordinary spectrophotometry and 11.8-320.0 ng/ml for first derivative spectrophotometry. The HNB is not selectivity for aluminium, but the addition of EDTA allows the aluminium determination in the presence of accepted amounts of Ca(II), Mg(II), Mn(II), Ba(II), Sr(II), Cd(II), Pb(II), La(III), In(III), Bi(III) and Zn(II). The interference of Cu(II) and Hg(II) can be masked by thiosulphate. Ions such as UO(2)(II), Mo(VI), Co(II), Ti(IV) and PO(4)(III) do interfere seriously. This method was applied for aluminium determination in copper-base alloy, zinc-base alloy, magnesium-base alloy, iron ore, manganese ore, cement, dolomite, feldspar and limestone. The results indicated high accuracy and precision.  相似文献   

20.
A redox reaction of cysteine with iron(III) proceeds slowly in the presence of 1,10-phenanthroline (phen). However, this reaction is accelerated in the presence of copper(II) as a catalyst, producing an iron(II)-phen complex (lambda(max)=510 nm). A sensitive spectrophotometric flow-injection method is proposed for the determination of copper(II) based on its catalytic action on this redox reaction. The dynamic range was 0.1-10 ng ml(-1) of copper(II) with a relative standard deviation of 1.0% (n=10) for 1.0 ng ml(-1) of copper(II) at a sampling rate of 30 h(-1). The detection limit (S/N=3) is 0.04 ng ml(-1). The proposed method was successfully applied to the determination of copper in river water as a certified reference material.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号