首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
2.
Tri-, tetra- and pentachlorophenol (TCP, TeCP and PCP) can be considered the precursors in the formation of corresponding chloroanisoles, known to be powerful odorants in corks and wine. Determining the presence of these chlorophenolic compounds in cork soaking solutions (ethanol/water mixtures, 12% (v/v) ethanol used for cork quality control testing), or in wine can be achieved by acetylation/gas chromatography electron-capture detection. In order to reach the required sensitivity, a previous preconcentration step is necessary. Solid-phase extraction (SPE) and headspace solid-phase microextraction (HS-SPME) have given good results for the preconcentration of TCP, TeCP and PCP in such matrices. The use of Oasis HLB cartridges gives acceptable recoveries for the three compounds when different volumes (50-250 mL) of cork macerate with concentrations ranging from 20 to 150 ng/L are processed. Preconcentration based on HS-SPME has also been optimised with a 100 microm polydimethylsiloxane fibre and in situ derivatization. The HS-SPME method allows chlorophenols in a cork soaking solution and in wine to be determined with a limit of detection of 1 ng/L for each compound (in cork macerate) and a repeatability of around 0.5%-5% (n=8) for a concentration level of 30 ng/L.  相似文献   

3.
This work presents an advantageous analytical procedure for the accurate determination of free trans-resveratrol in red and white wines. The proposed method involves solid-phase extraction (SPE), acetylation of the analyte in aqueous media and further determination by gas chromatography (GC) with mass spectrometry detection (MS). The use of a mixed-mode SPE sorbent provides an improvement in the selectivity of the extraction step; moreover, the presence of several intense ions in the electron impact mass spectra of its acetyl derivative guarantees the unambiguous identification of trans-resveratrol. Considering a sample intake of 10 mL, the method provides a limit of quantification (LOQ) of 0.8 ng mL−1 and linear responses for concentrations up to 2.5 μg mL−1, referred to wine samples. The average recovery, estimated with samples fortified at different concentrations in the above range, was 99.6% and the inter-day precision stayed below 8%. Trans-resveratrol levels in the analyzed wines varied from 3.4 to 1810 ng mL−1. Cis-resveratrol was also found in all samples. In most cases, equal or higher responses were measured for this latter form than for the trans-isomer. The reduced form of resveratrol, dihydro-resveratrol, was systematically identified in red wines.  相似文献   

4.
A practical strategy for the optimization of solid-phase extraction (SPE) systems is presented. Critical SPE volumes (sample loaded, rinsing and elution solvent) are calculated from solid–liquid extraction coefficients and from basic bed parameters determined in simple experiments, using the Lövkist Jonsson model and other expressions derived from the general theory of chromatography. The agreement between calculated and measured volumes is satisfactory, which makes it possible to consider different sorbents and rinsing and elution solvents in the SPE optimization with a relatively low experimental effort. The strategy has been successfully applied to the optimization of a SPE method directed to the selective extraction of aliphatic lactones from wine. Six different reversed-phase sorbents were studied and the one showing maximum extraction selectivity was selected. Wine (50 ml) is extracted in a 200 mg cartridge filled with Bond Elut-ENV resins. Interferences are removed with 20 ml of methanol–water (40:60) with 1% NaHCO3. Elution is carried out with 1.8 ml of dichloromethane. The extract is concentrated to 0.15 ml and analyzed by GC–ion trap MS. Eight odor-active aliphatic γ and δ lactones (with 8–12 C atoms) from wine are recovered (R>75%) in an extract free from wine major volatiles. Detection limits are in the 40–300 ng/l range, well below the odor detection threshold of these compounds. Linearity (r2>0.996) and precision (average R.S.D. 3.5%) are satisfactory in all cases. The levels in wine of some of these lactones (γ-octa, undeca and dodecalactones) are reported by first time and results demonstrate that can be present at concentrations above or close to their corresponding odor thresholds.  相似文献   

5.
Summary A gas chromatographic method is described for the analysis of arabitol, mannitol, sorbitol and inositol in wine. The method is evaluated for repeatability using perseitol as internal standard. Perseitol can be added to wine before or after passing the wine through the ion-exchange column without showing significant differences in the polyalcohol content. The method is also applied to the analysis of vinegar from different substrates (wine cider and rice).  相似文献   

6.
Traditional simultaneous distillation extraction (SDE) and solid-phase microextraction (SPME) techniques were compared for their effectiveness in the extraction of volatile flavor compounds from various mustard paste samples. Each method was used to evaluate the responses of some analytes from real samples and calibration standards in order to provide sensitivity comparisons between the two techniques. Experimental results showed traditional SDE lacked the sensitivity needed to evaluate certain flavor volatiles, such as 1,2-propanediol. Dramatic improvements in the extraction ability of the SPME fibers over the traditional SDE method were noted. Different SPME fibers were investigated to determine the selectivity of the various fibers to the different flavor compounds present in the mustard paste samples. Parameters that might affect the SPME, such as the duration of absorption and desorption, temperature of extraction, and the polarity and structure of the fiber were investigated. Of the various fibers investigated, the PDMS–DVB fiber proved to be the most desirable for these analytes.  相似文献   

7.
A method is described for simultaneous determination of semivolatile organic compounds (SVOCs) in indoor air by gas chromatography-mass spectrometry (GC-MS). The selected 73 SVOCs were collected using combined adsorbents (quartz fiber filter disk and Empore disk) for 24 h at a 5.0 l/min flow rate. The SVOCs collected were extracted with acetone, concentrated, then analyzed by an internal standard method. Forty compounds (19 plasticizers and flame retardants; 19 insecticides; 1 synergist; and 1 fungicide) among the target SVOCs were determined accurately and precisely. The method of detection limits for these compounds were approximately 0.5 ng/m3 for most of the SVOCs. The collected SVOC samples could be stored for up to 1 month at 4 C in the refrigerator.  相似文献   

8.
Summary A fast, simple, and reliable method is presented for the determination of atmospheric semi-volatile organic pollutants at μg m−3 levels. The method has been used to monitor potentially carcinogenic toxic compounds to which workers are exposed in workplaces, and to measure the same compounds in outdoor air. Dedicated to Michele Di Pasquale (deceased).  相似文献   

9.
A new method for analysing 3-isopropyl-2-methoxypyrazine, 3-sec-butyl-2-methoxypyrazine and 3-isobutyl-2-methoxypyrazine in wine has been developed and applied to wine. The analytes are extracted from 25 mL of wine in a solid-phase extraction cartridge filled with 60 mg of cation-exchange mixed-mode sorbent. Analytes are recovered with triethylamine in dichloromethane and the organic extract is analysed by GC-SIM-MS using 3-isopropyl-2-ethoxypyrazine as internal standard. The detection limits of the method are in all cases under 1 ng/L, below the olfactory thresholds of the compounds in wine. The repeatability of the method is around 15% for levels in wine of 2 ng/L. Linearity is satisfactory and recoveries are in all cases close to 100% with RSD between 13% and 20%. The method has been applied to the analysis of 12 Chilean white and 8 Spanish red wines. The levels found suggest that 3-alkyl-2-methoxypyrazines can exert a significant sensory contribution to the aroma of Chilean Sauvignon Blanc wines, while most likely they play a nearly negligible role on traditional Ribera and Rioja Spanish red wines.  相似文献   

10.
A gas chromatography-mass spectrometry method was established using headspace solid phase microextraction (HS-SPME) as the sampling procedure to analyse 3-mercaptohexan-1-ol (3-MH) and 3-mercaptohexyl acetate (3-MHA), two molecules with a tropical fruit aroma, in wine at trace level. This method offers important advantages, as it neither requires time-consuming sample preparation nor uses dangerous organic compounds, thus making control of wine aroma easier and suitable for routine analysis. As a comparison, a solid phase extraction (SPE) method, already described elsewhere for aroma analysis, was applied to quantify these analytes, extending this exhaustive enrichment to two important thiols. Detection limits for both the approaches were close to the sensory threshold value, resulting lower for the HS-SPME procedure and suitable for requirements in the oenological field. The application of the two proposed methods to 52 wines of different varieties gave similar results.  相似文献   

11.
Future understanding of differences in the composition and sensory attributes of wines require improved analytical methods which allow the monitoring of a large number of volatiles including those present at low concentrations. This study presents the optimization and application of a headspace solid-phase microextraction (HS-SPME) method for analysis of wine volatiles by comprehensive two-dimensional gas chromatography (GC×GC) time-of-flight mass spectrometry (TOFMS). This study demonstrates an important advancement in wine volatile analysis as the method allows for the simultaneous analysis of a significantly larger number of compounds found in the wine headspace compared to other current single dimensional GC-MS methodologies. The methodology allowed for the simultaneous analysis of over 350 different tentatively identified volatile and semi-volatile compounds found in the wine headspace. These included potent aroma compound classes such as monoterpenes, norisoprenoids, sesquiterpenes, and alkyl-methoxypyrazines which have been documented to contribute to wine aroma. It is intended that wine aroma research and wine sensory research will utilize this non-targeted method to assess compositional differences in the wine volatile profile.  相似文献   

12.
A new multiresidue method for the efficient screening, identification and quantification of over 160 pesticides belonging to different chemical classes in red, rose and white wines have been developed. The analysis was based on gas chromatographic-tandem quadrupole mass spectrometric determination (GC-QqQ-MS/MS). An optimization strategy involved the selection of buffering conditions and sorbents for dispersive-solid phase extraction (dispersive-SPE) in order to achieve acceptably high recoveries and reduce co-extractives in the final extracts. As a result, the optimized procedure allowed us to obtain consistent recoveries of the target pesticides including problematic ones such as captan, chlorothalonil, dichlofluanid, folpet and tolylfluanid. The attained recoveries were typically between 80 and 110% (89% on average) with RSD values typically lower than 10% (8% on average) at three spiking levels of 0.01, 0.05 and 0.2 mg kg−1. Linearity was studied in the range between 0.005 and 0.2 mg kg−1 using pesticide standards prepared both in pure solvent and in the presence of matrix, showing coefficients of determination (R2) higher than 0.99 for all the pesticides except for desmedipham, thiabendazole and thiamethoxam in pure solvent. The study of the ratio of the slopes obtained in solvent and in matrix provided information about the matrix effects, which was <10%, 10-20% and >20% for 33, 36 and 31% of the studied pesticides, respectively. To improve accuracy, matrix matched standards were always used for calculation of the quantification results. The expanded uncertainties were estimated by using a “top-down” approach as being 17% on average (coverage factor k = 2, confidence level 95%). Finally, the method was used with success to detect and quantify pesticide residues in commercial wines.  相似文献   

13.
In this work, a reliable and selective procedure for the determination of thirteen fungicides in red and white wine samples is proposed. Solid-phase extraction (SPE) and liquid chromatography (LC) tandem mass spectrometry (MS/MS), based on a hybrid quadrupole time-of-flight (QTOF) system, were used as sample preparation and determination techniques, respectively. Extraction and purification of target analytes was carried out simultaneously by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Fungicides were determined operating the electrospray source in the positive ionization mode, with MS/MS conditions adjusted to obtain at least two intense product ions per compound, or registering two transitions per species when a single product was noticed. High selective MS/MS chromatograms were extracted using a mass window of 20 ppms for each product ion. Considering external calibration as quantification technique, the overall recoveries (accuracy) of the procedure ranged between 81% and 114% for red and white wine samples (10-20 mL), spiked at different concentrations between 5 and 100 ng mL(-1). Relative standard deviations of the above data stayed below 12% and the limits of quantification (LOQs) of the method, calculated for 10 mL of wine, varied between 0.1 ng mL(-1) for cyprodinil (CYP) and 0.7 ng mL(-1) for myclobutanil (MYC). The optimized method was applied to seventeen commercial wines produced in Spain and obtained from local supermarkets. Nine fungicides were determined, at levels above the LOQs of the method, in the above samples. The maximum concentrations and the highest occurrence frequencies corresponded to metalaxyl (MET) and iprovalicarb (IPR).  相似文献   

14.
An inexpensive and effective sample preparation procedure for the determination of three ethylphenolic off-flavours (4-ethylphenol, 4-ethylguaiacol and 4-ethylcathecol) in wine samples is presented. Analytes were in situ acetylated and concentrated using a disposable silicone sorbent (DSS) exposed to the diluted sample. After that, the analytes were recovered with ethyl acetate and determined by gas chromatography with mass spectrometry. The influence of different parameters (volume of acetic anhydride, basic catalyst, ionic strength, sorbent format, sampling mode and extraction time) on the efficiency of derivatization and extraction steps is discussed. Under optimized conditions, 2 mL of wine were diluted with 15 mL of an aqueous solution of potassium bicarbonate (5%, m/v) in a 22 mL vessel, containing 2 g of sodium chloride. The volume of acetic anhydride and the extraction time were set at 90 μL and 2 h, and the extraction was carried out at room temperature (20±2°C). Analytes were concentrated using a silicone disc (5 mm diameter × 0.5 mm thickness) and further desorbed with 0.2 mL of ethyl acetate. The achieved limits of quantification (LOQs), defined as the concentration of each compound providing a signal 10 times higher than the baseline noise, stayed between 5 and 15 ng mL(-1). The method provided a linear response range of up to 5000 ng mL(-1) and relative recoveries from 91% to 116%. The 4-ethylphenol off-flavour was detected in most red wine samples at concentrations of up to 2700 ng mL(-1).  相似文献   

15.
Simple and rapid gas chromatographic (GC) method employing a high-resolution time-of-flight mass analyzer that enables direct analysis (no derivatization) of acrylamide in various heat-processed foodstuffs has been developed and validated. Co-isolation of acrylamide precursors such as sugars and asparagine, constituting the risk of results overestimation due to additional formation of analyte in hot GC injector, is avoided by the extraction with n-propanol followed by solvent exchange to acetonitrile (MeCN). Introduction of a novel purification strategy, dispersive solid phase extraction, based on addition of primary-secondary amine (PSA) sorbent into deffated extract in MeCN, provides a significant reduction of some abundant matrix co-extracts (mainly free fatty acids). Isotope dilution technique (d3-acrylamide as an internal standard) is employed for compensation of potential target analyte losses and/or matrix-inducted chromatographic response enhancement. Limits of quantifications (LOQs) ranged between 15 and 40 μg kg−1 and recoveries were between 97 and 108% depending on the examined food matrix. The repeatability of measurements (expressed as relative standard deviation, R.S.D.) was as low as 1.9% for potato crisps containing acrylamide at a level of 1 mg kg−1. Slightly higher values (R.S.D. < 4.0%) were achieved for breakfast cereals and crisp bread with approximately 10 times lower content of this processing contaminant. Trueness of results generated by this new method was demonstrated via FAPAS® (Food Analysis Performance Assessment Scheme) interlaboratory proficiency tests.  相似文献   

16.
建立了固相萃取、毛细柱气相色谱-质谱、内标标准曲线法使用选择离子(SIM)监测采集数据定量分析水中硝基苯类有机化合物的分析方法.通过对固相萃取柱的选择、固相萃取条件(样品溶液的pH、上样速率、上样体积、洗脱液选择及配比)的优化,得出了最佳实验条件.始漏体积达1.5 L.回收率大于80%.检出限为0.015~0.045 μg/L.RSD在1.1%~5.9%之间.  相似文献   

17.
A novel procedure for the determination of nine selected fungicides (metalaxyl-M, azoxystrobin, myclobutanil, flusilazole, penconazole, tebuconazole, propiconazole, diniconazole and difenoconazole) in wine samples is presented. Sample enrichment and purification is simultaneously performed using mixed-mode, anion exchange and reversed-phase, OASIS MAX solid-phase extraction (SPE) cartridges. Analytes were determined by liquid chromatography coupled to tandem mass spectrometry using atmospheric pressure electrospray ionization (LC-ESI-MS/MS). Parameters affecting the chromatographic determination and the extraction-purification processes were thoroughly investigated. Under optimized conditions, 10 mL of wine were firstly diluted 1:1 with ultrapure water and then passed through the mixed-mode SPE cartridge at a flow of ca. 5 mLmin(-1). After a washing step with 5 mL of an aqueous NH(4)OH solution (5%, w:v), analytes were recovered with just 1 mL of methanol and injected in the LC-MS/MS system without any additional purification. The selective extraction process avoided significant changes in the ionization efficiency for red and white wine extracts in comparison with pure standards in methanol. Performance of the method was good in terms of precision (RSDs<11%) and accuracy (absolute recoveries>72%, determined against pure standards in methanol) reporting method LOQs in the range of 0.01-0.79 ngmL(-1) for target compounds, which are far below the EU maxima residue levels (MRLs) for fungicides in vinification grapes and wine. Several commercial wines from different geographic areas in Spain were analyzed. In most samples, metalaxyl-M and azoxystrobin were found at concentrations up to several ngmL(-1).  相似文献   

18.
A multiresidue method based on solid-phase extraction was developed for the simultaneous determination of 50 pesticides in commercial juices. The extraction procedure was carried out in C18 columns preconditioned with acetonitrile and water. The subsequent elution of pesticides was performed with a mixture of hexane-ethyl acetate (1:1, v/v) prior to the determination by gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC-MS-SIM), using one target and two qualifier ions. Standards were prepared spiking blank juice samples to counteract the observed matrix effect. Average recoveries for all the pesticides studied were higher than 91% with relative standard deviations lower than 9% in the concentration range of 0.02-0.1 μg/mL and the detection limits achieved ranged from 0.1 to 4.6 μg/L. The proposed method was applied to the analysis of these compounds in commercial juices and diazinon, ethion and procymidone were the pesticides encountered, although the levels found were very low.  相似文献   

19.
Ethanol in wines was determined by flow injection analysis with an amperometric detector using an oxidized nickel wire. Solid-phase extraction with a strong anion exchanger was used to remove interferences such as organic acids from the matrix, and the residue of the extraction was injected directly into the FIA system. The recoveries of ethanol from wines spiked with standards ranged from 101% to 103%. The response of the nickel electrode to ethanol is dependent on the applied potential and the pH of the carrier. The optimal conditions for the detection of ethanol were an applied potential of +0.60 V (vs. Ag/AgCl) in a carrier of 100 mM sodium hydroxide solution. The electrode exhibited a linear response from 10−5 to 10−3 M, with a detection limit of 1 × 10−6 M. The method was demonstrated by the determination of ethanol in wines.  相似文献   

20.
A novel analytical approach has been developed and evaluated for the quantitative analysis of a selected group of widely used pesticides (dimethoate, simazine, atrazine, diuron, terbuthylazine, methyl-parathion, methyl-pirimiphos, endosulfan I, endosulfan II, endosulfan sulphate, cypermethrin and deltamethrin), which can be found at trace levels in olive oil and olives. The proposed methodology is based on matrix solid-phase dispersion (MSPD), (with a preliminary liquid-liquid extraction in olive oil samples) using aminopropyl as sorbent material with a clean-up performed in the elution step with Florisil, followed by mass spectrometric identification and quantitation of the selected pesticides using both gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) mode and liquid chromatography tandem mass spectrometry (LC-MS-MS) in positive ionization mode. The recoveries obtained (with mean values between 85 and 115% (obtained at different fortification levels) with RSD values below 10% in most cases, confirm the usefulness of the proposed methodology for the analyses of these kind of complex samples with a high fat content. Moreover, the obtained detection limits, which were below 5 microg kg(-1) by LC-MS analyses and ranged from 10 to 60 microg kg(-1) by GC-MS meet the requirements established by the olive oil pesticide regulatory programs. The method was satisfactorily applied to different olives and olive oil samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号