首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive liquid chromatographic–electrospray ionization mass spectrometric method was developed and validated for fast determination of telmisartan in human plasma. Plasma of 0.1 mL was deprotienated with methanol, centrifugation, evaporation to dryness and dissolving in mobile phase, samples were separated using a Hypersil-Keystone C18 reversed-phase column (150 mm × 2.1 mm i.d., 5 μm), together with a mobile phase containing of acetonitrile–10 mM ammonium acetate (42:58, v/v), 0.2% acetic acid and was isocratically eluted at a flow rate of 0.2 mL/min. Telmisartan and its internal standard, valsartan, were measured by electrospray ion source in positive selective ion monitoring mode. The method demonstrated linearity from 1 to 2000 ng/mL (r = 0.9988). The limit of quantification for telmisartan in plasma was 1 ng/mL with good accuracy and precision. The mean sample extract recovery of the method were higher than 82 and 78% for telmisartan and internal standard (IS), respectively. The within-run and between-run precision ranged from 3.4 to 8.9% and 5.9 to 11.2% (relative standard deviation, R.S.D.), respectively.  相似文献   

2.
An improved liquid chromatographic tandem mass spectrometric method for the determination of glimepiride in human plasma has been developed and fully validated. The article describes in detail the bioanalytical procedure and summarizes the validation results obtained. The samples were extracted using liquid--liquid extraction with a mixture of 1-chlorobutane-isopropanol-ethyl acetate (88:2:10, v/v/v). The chromatographic separation was performed on a reversed-phase Hypersil ODScolumn (250 x 4.6 mm i.d.; 5 microm particle size) using a mobile phase consisting of formic acid 0.05 M-acetonitrile (28:72, v/v), pumped at a flow rate of 0.3 ml min(-1) heated to 25 degrees C. The analytes were detected using an API 3000 triple quadrupole mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. Tandem mass spectrometric detection enabled the quantitation of glimepiride down to 0.50 ng mL(-1). Calibration graphs were linear (r better than 0.998, n=1), in concentration range 0.50--1000 ng mL(-1), and the intra- and inter- day RSD values were less than 10.37 and 11.55% for glimepiride. The method was successfully applied to a kinetic study in order to assess the main pharmacokinetic parameters of glimepiride.  相似文献   

3.
Qian Luo  Minghung Wong  Zongwei Cai   《Talanta》2007,72(5):1644-1649
Analytical method using mass spectrometric techniques was applied for the determination of polybrominated diphenyl ethers (PBDEs) in freshwater fishes. Fish samples collected from Nanyang River contaminated by the recycling electron-wastes (e-wastes) materials were prepared by using Soxhlet extraction and multiple-step column chromatographic clean-up. PBDEs were determined by gas chromatography (GC) coupled with ion trap mass spectrometry (for mono- to hepta-BDEs) and quadrupole mass spectrometry (for BDE-209). The method performance was evaluated with the recovery of 13C-labeled internal standards and with the analysis of certified reference biota. The obtained recoveries ranged from 75 to 125% with a relative standard deviation of lower than 10% for 16 PBDE congeners. The total PBDE (ΣPBDE) concentrations in fishes showed the following trend: grass carp < mud carp < crucian carp < silver carp < carp. ΣPBDE concentrations in the abdomen, back and tail muscles of carp ranged from 766, 458 and 530 ng/g w.w., and 53, 52, 45 ng/g w.w. in grass carp, respectively. The ΣPBDE concentrations in abdomen muscles were no significantly higher than in back and tail muscles in carp, crucian carp, grass carp and mud carp. PBDE congener concentrations in muscles correlated well with their lipid content. BDE-47 and BDE-28 were the most abundant congeners followed by BDE-17, BDE-15, BDE-66, BDE-154 and BDE-153 in fishes collected from Guiyu.  相似文献   

4.
A rapid, sensitive and reliable high performance liquid chromatographic method coupled with tandem mass spectrometry (HPLC–MS/MS) has been developed and validated for the determination of cilnidipine, a relatively new calcium antagonist, in human plasma. The reversed-phase chromatographic system was interfaced with a TurboIonSpray (TIS) source. Nimodipine was employed as the internal standard (IS). Sample extracts following protein precipitation were injected into the HPLC–MS/MS system. The analyte and IS were eluted isocratically on a C18 column, with a mobile phase consisting of CH3OH and NH4Ac (96:4, v/v). The ions were detected by a triple quadrupole mass spectrometric detector in the negative mode. Quantification was performed using multiple reaction monitoring (MRM) of the transitions m/z 491.2 → 122.1 and m/z 417.1 → 122.1 for cilnidipine and for the IS, respectively. The analysis time for each run was 3.0 min. The calibration curve fitted well over the concentration range of 0.1–10 ng mL−1, with the regression equation Y = (0.103 ± 0.002)X + (0.014 ± 0.003) (n = 5), r = 0.9994. The intra-day and inter-day R.S.D.% were less than 12.51% at all concentration levels within the calibration range. The recoveries were between 92.71% and 97.64%. The long-term stability and freeze-thaw stability were satisfying at each level. The present method provides a modern, rapid and robust tool for pharmacokinetic studies of cilnidipine.  相似文献   

5.
A sensitive method for the simultaneous determination of fluoxetine and its major active metabolite norfluoxetine in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted from alkalised plasma with hexane-isoamyl alcohol (98:2, v/v) followed by back-extraction into formic acid (2%). Chromatography was performed on a Phenomenex Luna C18 (2) 5 microm, 150x2 mm column with a mobile phase consisting of acetonitrile-0.02% formic acid (340:660, v/v) at a flow-rate of 0.35 ml/min. Detection was achieved by a Perkin-Elmer Sciex API 2000 mass spectrometer (LC-MS-MS) set at unit resolution in the multiple reaction monitoring mode. TurbolonSpray ionisation was used for ion production. The mean recoveries for fluoxetine and norfluoxetine were 98 and 97%, respectively, with a lower limit of quantification set at 0.15 ng/ml for the analyte and its metabolite. This assay method makes use of the increased sensitivity and selectivity of mass spectrometric (MS-MS) detection to allow for a more rapid (extraction and chromatography) and sensitive method for the simultaneous determination of fluoxetine and norfluoxetine in human plasma than has previously been described.  相似文献   

6.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

7.
A simple, sensitive, and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method, using electrospray ionization, was developed and validated to quantify trimetazidine in human plasma using propranolol hydrochloride as an internal standard (IS). Samples were prepared by solid-phase extraction and analyzed without drying and reconstitution. The analyte and IS were chromatographed on a C18 reversed-phase column under isocratic conditions using 2 mM ammonium acetate (pH 3.5)-acetonitrile (40 + 60, v/v) as the mobile phase with a run time of 2.0 min. Quantitation was done on a triple-quadrupole mass analyzer API-3000, equipped with turbo ion spray interface and operating in multiple reaction monitoring mode to detect parent --> product ion (m/z 267.2 --> 181.4) transition. The method was validated for sensitivity, accuracy and precision, linearity, recovery, matrix effect, and stability. Linearity in plasma was observed over the concentration range of 1.5-300 ng/mL. Lower limit of quantification achieved was 1.5 ng/mL with precision < 10% using 10 microL injection volume. The mean relative recovery of analyte (97.36%) and IS (99.93%) was consistent and reproducible. Interbatch and intrabatch precision was < 8.0% and the accuracy determined was within +/- 8% in terms of relative error.  相似文献   

8.
A sensitive method for the determination of 3-desmethylthiocolchicine in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The plasma samples were extracted with ethyl acetate and separated on a Phenomenex Luna C18(2) 5 microm, 150x2 mm column with a mobile phase consisting of acetonitrile-0.005% formic acid (350:650, v/v) at a flow rate of 0.35 ml/min. Detection was achieved by an Applied Biosystems API 2000 mass spectrometer (LC-MS-MS) set at unit resolution in the multiple reaction monitoring mode. TurbolonSpray ionisation was used for ion production. The mean recovery for 3-desmethylthiocolchicine was 70%, with a lower limit of quantification set at 0.39 ng/ml. The increased selectivity of mass spectrometric (MS-MS) detection allowed us to distinguish between thiocolchicoside and its primary metabolite 3-desmethylthiocolchicine in human plasma, thereby giving more insight about the pharmacokinetics of the drug in humans.  相似文献   

9.
A rapid tandem mass spectrometric (MS-MS) method for the quantification of Oxcarbazepine (OXB) in human plasma using imipramine as an internal standard (IS) has been developed and validated. Chromatographic separation was achieved isocratically on a C18 reversed-phase column within 3.0 min, using a mobile phase of acetonitrile-10 mM ammonium formate (90 : 10 v/v) at a flow rate of 0.3 ml/min. Quantitation was achieved using multiple reaction monitoring (MRM) scan at MRM transitions m/z 253>208 and m/z 281>86 for OXB and the IS respectively. Calibration curves were linear over the concentration range of 0.2-16 mug/ml (r>0.999) with a limit of quantification of 0.2 mug/ml. Analytical recoveries of OXB from spiked human plasma were in the range of 74.9 to 76.3%. Plackett-Burman design was applied for screening of chromatographic and mass spectrometric factors; factorial design was applied for optimization of essential factors for the robustness study. A linear model was postulated and a 2(3) full factorial design was employed to estimate the model coefficients for intermediate precision. More specifically, experimental design helps the researcher to verify if changes in factor values produce a statistically significant variation of the observed response. The strategy is most effective if statistical design is used in most or all stages of the screening and optimizing process for future method validation of pharmacokinetic and bioequivalence studies.  相似文献   

10.
Ondansetron and its hydroxylated metabolites were determined in human serum using solid-phase extraction (SPE) and liquid chromatography/positive ion electrospray tandem mass spectrometry. Pyrimethamine was used as the internal standard. The analytes were eluted from the SPE cartridge using 2 x 1 ml of methanol containing 0.5% triethylamine, evaporated under vacuum and the residue was reconstituted in the mobile phase. The liquid chromatographic separation was achieved on a silica column using a mobile phase of aqueous 20 mM ammonium acetate (pH 4.7)-acetonitrile (85 : 15, v/v) at a flow-rate of 0.4 ml min(-1). The method was linear over the range 1-500 ng ml(-1) for ondansetron and each of the metabolites in human serum. The intra-day accuracy was better than 9.1% and the precision was <10.3%; the inter-day accuracy was better than 9.5% and the precision was <12.6%. The limit of detection was 250 pg ml(-1) based on a signal-to-noise ratio of 3. The absolute recovery from serum for all analytes was >90%.  相似文献   

11.
A sensitive enantioselective liquid chromatographic assay with mass spectrometric detection (LC-MS) has been validated for the determination of total and free plasma concentrations of (R)- and (S)-methadone (Met) and (R)- and (S)-2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP, the primary metabolite of Met), using their respective deuterium-labeled compounds as internal standards [(R,S)-d3-Met and (R,S)-d3-EDDP]. For total drug determinations, 1 ml human plasma was extracted, using a cation-exchange solid-phase extraction cartridge; the eluate was evaporated, reconstituted in the mobile phase, and injected into the LC-MS system. The free fractions of Met and EDDP were determined, using 500 microl of plasma, which were placed in an ultrafiltration device and centrifuged at 2000 x g until 250 microl of filtrate was collected. The filtrate was extracted as described above and analyzed. Enantioselective separations were achieved using an alpha1-acid glycoprotein chiral stationary phase, a mobile phase composed of acetonitrile-ammonium acetate buffer [10 mM, pH 7.0] (18:82, v/v), a flow rate of 0.9 ml/min at 25 degrees C. Under these conditions, enantioselective separations were observed for Met (alpha = 1.30) and EDDP (alpha = 1.17) within 15 min. Met, EDDP, [2H3]-Met and [2H3]-EDDP were detected using selected ion monitoring at m/z 310.30, 278.20, 313.30, and 281.20, respectively. Linear relationships between peak height ratio and drug-enantiomer concentrations were obtained for Met in the range 1.0-300.0 ng/ml, and for EDDP from 0.1 to 25.0 ng/ml with correlation coefficients greater than 0.999, where the lower limit of quantification (LLOQ) was 1 ng/ml for Met and 0.1 ng/ml for EDDP. The relative standard deviation (R.S.D.) expressed as R.S.D. for the intra- and inter-day precision of the method were < 5.3% and the R.S.D. for accuracy was < 5.0%. The method was used to analyze plasma samples obtained from patients enrolled in a Met-maintenance program.  相似文献   

12.
Throughout the separation of chiral basic drugs by capillary electrophoresis (CE) with neutral hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral selector, the sensitivity of detection can be improved by using tandem mass spectrometric (MS-MS) detection with a partial filling technique rather than with UV spectrometric detection. Prior to sample injection. the capillary was partly filled with HP-beta-CD dissolved in volatile ammonium formate buffer (pH 4, ionic strength 50 mM). The effects of modifying the HP-beta-CD concentration in the selector zone and the length of the separation zone on the enantioresolution and the signal-to-noise ratio of the pseudo-molecular MH+ ion were investigated. For a given selector zone length, as the concentration of the neutral cyclodextrin increases, the resolution between enantiomers becomes higher (the opposite of the behavior of the signal-to-noise ratio) and then reaches an optimum value. The decrease of the selector zone length lowered the resolution between the enantiomers but increased peak efficiencies and signal-to-noise ratio values. Accordingly, partial capillary filling at 80% (v/v) and 10 mM concentration of HP-beta-CD was selected as a suitable compromise between resolution and sensitivity of MS detection. Limits of detection for each adrenoreceptor antagonist enantiomer were 5 ng/ml (0.02 microM) in CE-MS-MS instead of 150 ng/ml (0.60 microM) in CE-UV, which enhances sensitivity by a factor of 30.  相似文献   

13.
A novel High Performance Liquid Chromatography-electrospray mass spectrometric method has been developed for the estimation of Ursodiol (Ursodeoxycholic acid)--a bile acid, in human plasma using Ornidazole as internal standard. The methodology involved solid phase extraction of the analyte from human plasma matrix. The chromatographic separation was achieved within seven minutes by an isocratic mobile phase containing 1.0 mM ammonium acetate and Acetonitrile (65:35, v/v), flowing through XTerra MS C18, 100 x 2.1, 3.5 microm analytical column, at a flow rate of 0.2 ml/min. Ion signals were measured in negative mode for Ursodiol and internal standard at m/z 391.3 and 278.1, respectively. A detailed validation of the method was performed as per USFDA guidelines and the standard curves were found to be linear in the range 50.0 ng/ml to 3000.0 ng/ml with the mean correlation coefficient more than 0.99. The absolute recovery was more than 54.90% for Ursodiol and 76.51% for internal standard. Ursodiol was stable for sixty-nine days at -70 degrees C and for eight hours at ambient temperature. After extraction from plasma, the reconstituted samples of Ursodiol were stable in autosampler at 10 degrees C for forty-eight hours. Upon subjecting to three freeze thaw cycles, there was no change in the recovery of the analyte. The integrity of the plasma samples remained unaffected even upon four-fold dilution with drug free human plasma. The method was simple, specific, sensitive, precise, accurate and suitable for bioequivalence and pharmacokinetic studies. It was successfully applied to the pilot bioequivalence study of Ursodiol in male human subjects.  相似文献   

14.
A sensitive, selective, specific and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric assay method was developed and validated for the simultaneous quantitation of alpha-,beta-arteether (alpha-,beta-AE) and its metabolite alpha-dihydroartemisinin (DHA) in monkey plasma using the propyl ether analogue of beta-arteether (PE) as an internal standard. The method involves a simple two-step liquid-liquid extraction with hexane. The analytes were chromatographed on a C(18) reversed-phase chromatographic column by isocratic elution with methanol-ammonium acetate buffer (pH 4) (92 : 8, v/v) and analysed by mass spectrometry in the multiple reaction monitoring mode. The chromatographic run time was 7 min and the weighted (1/x(2)) calibration curves were linear over the range 0.78-200 ng ml(-1). The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in monkey plasma were 0.39 and 0.78 ng ml(-1) respectively for all the analytes. The intra- and inter-batch precision and accuracy were found to be well within acceptable limits (<15%). All three analytes were stable even after three freeze-thaw cycles (deviation < 15%). The average absolute recoveries of alpha-,beta-AE, DHA and PE, used as an internal standard, from spiked plasma samples were 85.85 +/- 6.56, 70.10 +/- 7.06, 54.37 +/- 3.39 and 93.90 +/- 6.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of alpha-,beta-AE and DHA in rhesus monkeys.  相似文献   

15.
A rapid and sensitive method for the determination of domperidone in plasma was developed, using high-performance liquid chromatographic separation with tandem mass spectrometry detection. The samples were rendered basic with 1 M Na2CO3 and the domperidone extracted using tert.-butyl methyl ether, followed by back-extraction into formic acid (2% in water). Chromatography was performed on a Phenomenex Luna C8 (2), 5 microm, 150x2 mm column with a mobile phase consisting of acetonitrile-0.02% formic acid (300:700, v/v), delivered at 0.2 ml/min. Detection was performed using an Applied Biosystems Sciex API 2000 mass spectrometer set at unit resolution in the multiple reaction monitoring mode. TurbolonSpray ionisation was used for ion production. The mean recovery of domperidone was +/- 100%, with a lower limit of quantification set at 0.189 ng/ml. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometric detection resulting in a rapid (extraction and chromatography) and sensitive method for the determination of domperidone in human plasma, which is more sensitive than previously described methods.  相似文献   

16.
A simple high performance liquid chromatography techniques with ultraviolet detection (HPLC–UV) method is described for the simultaneous determination of clozapine (CZP), clozapine N-oxide (CNO), N-desmethylclozapine (NCZ), risperidone (RSP) and 9-hydroxyrisperidone (9-OHRSP) in human plasma. After extraction process, the analytes were separated on a C18 column (150 mm×3.9 mm i.d.) by the mobile phase (methanol–water–dimethylamine, 60:40:0.04 (v:v:v)). Relative recoveries of five analytes were quantitative. The precision and accuracy of intra- and interday assays were all below 8.2% for R.S.D. and 5.6% for RE, respectively. Based on 1 ml of plasma, the limits of detection were 2.0 ng/ml for CZP, 0.2 ng/ml for CZP N-oxide, 1.0 ng/ml for NCZ, 1.0 ng/ml for RSP, and 0.5 ng/ml for 9-OHRSP (S/N=3). The calibration curves were linear (r≥0.988). This method was applied to therapeutic drug monitoring of schizophrenia patients receiving CZP or RSP therapy.  相似文献   

17.
The development of a liquid chromatography/tandem mass spectrometric assay for the quantitative analysis of the novel tubulin inhibitor D-24851 in human plasma and urine is described. D-24851 and the deuterated internal standard were extracted from 250 microL of plasma or urine using hexane/ether (1:1, v/v). Subsequently, 10-microL aliquots of reconstituted extracts were injected onto an Inertsil ODS analytical column (50 x 2.0 mm i.d., 5 microm particle size). An eluent consisting of methanol/5 mM ammonium acetate, 0.004% formic acid in water (80:20, v/v) was pumped at a flow rate of 0.2 mL/min. An API 365 triple quadrupole mass spectrometer was used in the multiple reaction monitoring mode for sensitive detection. For human plasma a dynamic range of 1-1000 ng/mL was validated, and for human urine a range of 0.25-50 ng/mL. Validation was performed according to the most recent FDA guidelines and all results were within requirements. The assay has been successfully applied to support a phase I clinical trial with orally administered D-24851.  相似文献   

18.
The present work displays capillary liquid chromatographic column switching methodology tailored for determination of benzo[a]pyrene tetrol isomers in biological matrices using on-line fluorescence and micro-electrospray ionization mass spectrometric detection. A well-established off-line crude solid phase extraction procedure was used in order to make the method compatible with several biological matrices. The solid phase extraction eluates were evaporated to dryness, redissolved in 1.0 ml methanol:water (10:90, v/v), loaded onto a 0.32 mm I.D. x 40 mm 5 microm Kromasil C(18) pre-column for analyte enrichment and back-flushed elution onto a 0.30 mm I.D. x 150 mm 3.5 microm Kromasil C(18) analytical column. The samples were loaded with a flow rate of 50 microl min(-1) and the tetrols were separated at a flow rate of 4 microl min(-1) with an acetonitrile:10 mM ammonium acetate gradient from 10 to 90%. A sample loading flow rate up to 50 microl min(-1) was allowed. The fluorescence excitation and emission were set to 342 and 385 nm, respectively, while mass spectrometric detection of the benzo[a]pyrene tetrols was obtained by monitoring their [M - H](-) molecular ions at m/z 319. The method was validated over the concentration range 0.1-50 ng ml(-1) benzo[a]pyrene tetrols in a cell culture medium with 100 microl injection volume, fluorescence detection and the first eluting tetrol isomer as model compound, resulting in a correlation coefficient of 0.993. The within-assay (n= 6) and between-assay (n= 6) precisions were determined to 2.6-8.6% and 3.8-9.6%, respectively, and the recoveries were determined to 97.9-102.4% within the investigated concentration range. The mass limit of detection (by fluorescence) was 3 pg for all the tetrol isomers, corresponding to a concentration limit of detection of 30 pg ml(-1) cell culture medium. The corresponding mass spectrometric mass limits of detection were 4-10 pg, corresponding to concentration limits of detection of 40-100 pg ml(-1) cell culture medium.  相似文献   

19.
Abstract

A simple and sensitive high-performance liquid chromatographic method for quantitation of clopamide in human plasma has been developed. the assay uses a reversed-phase C18 microbore column (2 mm I.D. × 100 mm) packed with 5 μm ODS Hypersil. the chromatographic separation was achieved by using an isocratic mobile phase comprising acetonitrile-10 mM phosphate buffer pH 4 (17:83, v/v) at a flow rate of 0.5 ml/min. the eluant was monitored by a UV detector operating at 241 nm. the assay was based on an organic extraction before chromatographic separation. to 1 ml plasma sample, 100 μl of the internal standard, methylparaben (300 ng/ml), and 8 ml of diethyl ether were added. the samples were shaken and centrifuged, the organic layer was then transferred to a tapered centrifuge tube and evaporated to dryness. the residue was reconstituted and injected onto the HPLC column. the inter-and intra-assay coefficients of variation were found to be less than 10%. the lowest limit of detection for clopamide in plasma was 5 ng/ml. the method is sensitive, specific and allows for routine analysis in the pharmacokinetic studies.  相似文献   

20.
A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) assay for the quantitative analysis of the novel anticancer drug ABT-518 and the screening of six potential metabolites in human plasma has been developed and validated to support a phase I study with the drug. ABT-518 is an inhibitor of matrix metalloproteinases, which are associated with tumor growth and development of metastasis. Plasma samples were prepared for analysis using a simple solid-phase extraction method on phenyl cartridges. LC separation was performed on a Zorbax extend C18 column (150 x 2.1 mm i.d., 5 microm particle size) using a mobile phase of methanol-aqueous 10 mM ammonium hydroxide (80:20, v/v) pumped at a flow-rate of 0.2 ml min(-1). An API2000 triple-quadrupole mass spectrometer was used for specific and sensitive detection. The best chromatographic speed (total run time 8 min) and peak shapes were obtained by employing an alkaline mobile phase (pH in aqueous phase approximately 10). Furthermore, an alkaline eluent was favored in order to obtain a better overall sensitivity for the protonated analytes. The dynamic range was from 10 to 1000 ng ml(-1) from 500 microl of plasma for ABT-518 and the metabolites were detected at levels of the same order of magnitude. Inter-assay accuracies for ABT-518 at five concentration levels were between -9.24 and 6.93% and inter-assay precisions were always <10.7%. Analyte stability was not critical during either storage or processing. This method was successfully applied in a phase I clinical study of ABT-518. The active drug, ABT-518, and all of the metabolites included in the assay could be identified in plasma from dosed patients. We believe that the method described in this paper using an alkaline mobile phase in combination with a basic stable analytical column may also be generally useful for the bioanalysis of other basic drugs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号