首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
High-performance liquid chromatography combined with high-resolution mass spectrometry has been used to study the mild oxidation of sodium 2,3-disulfanyl-1-propanesulfonate (unithiol) with hydrogen peroxide. Reference peaks have been identified for the initial substance and reaction products. A possibility of using high-performance liquid chromatography with high-resolution mass spectrometry for the Sokolovskii thiol–disulphide test has been shown.  相似文献   

2.
Three methods, high-performance liquid chromatography hyphenated with inductively coupled plasma mass spectrometry, high-performance liquid chromatography-tandem mass spectrometry, and ion chromatography, were compared for simultaneous speciation of seven commercial gadolinium-based contrast agents for magnetic resonance imaging. Optimizations of experimental conditions for individual method were conducted, respectively. Methods of high-performance liquid chromatography hyphenated with inductively coupled plasma mass spectrometry and high-performance liquid chromatography-tandem mass spectrometry showed the capability of speciation for all seven target compounds, whereas ion chromatography was only suitable for three of them when using electronic conductivity detector. The limits of detection and limits of qualification by the three methods were compared, and high-performance liquid chromatography hyphenated with inductively coupled plasma mass spectrometry was found to be the most sensitive one. The limits of detection for seven target compounds by high-performance liquid chromatography hyphenated with inductively coupled plasma mass spectrometry were in the range of 0.15–0.55 pg. Thus, high-performance liquid chromatography hyphenated with inductively coupled plasma mass spectrometry was chosen as the final method and successfully applied to speciation analysis of seven gadolinium-based contrast agents in wastewater and whole blood. Compounds of gadoxetic acid disodium, gadobenate dimeglumine, gadodiamide, and gadobentetate dimeglumine were found in wastewater.  相似文献   

3.
Modified nucleosides in the urine have been postulated to be diagnostic indices of disease, particularly of cancer. The urine of a patient with terminal head and neck cancer has been found to contain a modified nucleoside with a protonated molecule of m/z 228. By means of high-performance liquid chromatography/ion trap mass spectrometry (HPLC/ITMS) and capillary liquid chromatography/triple quadruple mass spectrometry (CapLC/TQMS) we have identified the compound as 5'-deoxycytidine. This is the first report of 5'-deoxycytidine in man: in addition to the elucidation of its structure, its possible origins and the potential significance of its occurrence are discussed.  相似文献   

4.
Licorice, one of the oldest traditional Chinese medications, is widely used in the treatment of various diseases. With the development of science and technology, an increasing amount of analytical techniques have been applied to the quality control of licorice. Herein, we summarize several of the quality control methods developed in recent years. These approaches include sample preparation processes, high-performance thin layer chromatography, gas chromatography, gas chromatography/mass spectrometry, high-performance liquid chromatography, and liquid chromatography/mass spectrometry (LC/MS). Among these various techniques, LC/MS has come forward as one of the main methods forquality control of licorice.  相似文献   

5.
利用外部触发装置实现了毛细液相和超高效液相与静电场轨道阱高分辨质谱(LTQ-Orbitrap XL)的交互联用,建立了全方位的液相色谱-质谱联用分析以及液相色谱多级串联质谱联用分析平台.通过平台的应用大大提高了大型仪器的使用效率,促进了公共仪器平台的科研服务能力.  相似文献   

6.
The structural investigation of the products arising from 28 days incubation of albumin with high glucose concentration and further enzymatic hydrolysis has been carried out by means of high-performance liquid chromatography/mass spectrometry (HPLC/MS) under plasmaspray conditions. By this approach many different compounds have been detected, and for most of them, possible structures have been proposed on the basis of literature data and molecular weight assignments.  相似文献   

7.
The derivatization reaction of the mycotoxin moniliformin with 1,2-diamino-4,5-dichlorobenzene was previously introduced to improve distinctly the sensitivity of an assay applying high-performance liquid chromatography prior to fluorescence detection. In the course of the implementation of this derivatization approach into a liquid chromatographic/mass spectrometric method, an unexpected derivatization product has now been discovered by mass spectrometry. In order to elucidate its structure, detailed investigations with liquid chromatography/tandem mass spectrometry and liquid chromatography coupled on-line with NMR spectroscopy were performed. These studies give evidence for a heterocyclic structure that has been formed by the loss of one water and one carbon monoxide molecule. A reasonable mechanism for this derivatization reaction is proposed.  相似文献   

8.
Qualitative and quantitative analyses of urinary nucleosides have diagnostic potential as tumour markers. We have developed separation techniques linked to mass spectrometric detection in order to overcome the problems associated with past identification and quantitation methods. The three methods of analysis utilised were: gas chromatography/mass spectrometry (GC/MS), high-performance liquid chromatography/ion-trap mass spectrometry (HPLC/ITMS) and capillary liquid chromatography/triple quadrupole mass spectrometry (CapLC/TQMS). Here we compare the relative effectiveness of each of the techniques for subsequent application in the systematic study of urinary nucleoside profiles in cancer patients. All three methods proved to be valuable techniques for such urinary nucleoside analyses, and a combination rather than one single choice is concluded as the ideal.  相似文献   

9.
A procedure involving capillary column gas chromatography coupled to mass spectrometry and a method involving liquid chromatography coupled to a diode-array detector have been developed for the analysis of nalbuphine. The extraction step is the same for both techniques and involves extraction under alkaline conditions in chloroform-2-propanol-n-heptane (50:17:33, v/v/v) with levallorphan as the internal standard. After purification by acidic extraction and back alkaline extraction, drugs are derivatized with N,O-bis-(trimethylsilyl)trifluoroacetamide with 1% trimethylchlorosilane for gas chromatography-mass spectrometry and directly injected for high-performance liquid chromatography-diode-array detection. The limits of detection are 2.0 and 25.0 ng/mg, respectively.  相似文献   

10.
Atmospheric pressure chemical ionisation liquid chromatography/mass spectrometry/mass spectrometry (APCI-LC/MS/MS) has been applied to the study of bacteriochlorophylls c, d, and e of phototrophic prokaryotes. Cultures of Chlorobiaceae containing bacteriochlorophyll c, d or e were examined using a high-resolution high-performance liquid chromatography (HPLC) method and APCI-LC/MS/MS employing post-column addition of formic acid. The results reveal complex distributions of bacteriochlorophyll homologues, with some closely eluting species giving isobaric protonated molecules. On-line LC/MS/MS studies reveal characteristic fragment ions for bacteriochlorophylls c, d, and e. Fragmentations involving loss of the extended alkyl substituents that are unique to bacteriochlorophylls c, d and e and their derivatives have been rationalised by studying the phaeophorbides and the results applied to the direct study of the bacteriochlorophylls.  相似文献   

11.
Amino acid and peptide conjugates of protoporphyrin have been prepared by reacting protoporphyringen with cysteine, glutathione and peptides containing a free thiol group under acidic conditions. The conjugates were formed by the addition of the thioamino acids or peptides to the vinyl groups of protoporphyrin during the autoxidation of protoporphyinogen to protoporphyrin and is free-radical-mediated. The conjugates were separated by high-performance liquid chromatography (HPLC) and characterized by HPLC/electrospray ionization mass spectrometry (HPLC/ESI-MS) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). All the conjugates formed were diconjugates consisting of diastereoisomers.  相似文献   

12.
Olive drupe tissues have been selected as a possible source of information about the secondary metabolism of oleaceae secoiridoids. The structures of a number of new microcomponents, detected and isolated by a combined high-performance liquid chromatography (HPLC)-fraction collector/ultraviolet electrospray ionization mass spectrometry (UV/ESI-MS) apparatus, can be inferred from the data obtained by high-resolution tandem mass spectrometry in a QqTOF instrument. Some of them (1, 2, 3 and 4) are closely correlated to oleuropein. Others, such as neo-nuzhenide (5) and 2'-hydroxyoleuropein (6), typical of other oleaceae families, have never been found in olive tissues.  相似文献   

13.
This article discusses the separation, analysis and characterisation of intermediates and oxidative by-products of the haem biosynthetic pathway by liquid chromatography and mass spectrometry. Techniques reviewed include high-performance liquid chromatography, ultra-high-performance liquid chromatography, capillary electrophoresis, ion mobility spectrometry, mass spectrometry and tandem mass spectrometry. The emphasis was on the analysis of biological and clinical samples.  相似文献   

14.
Although frit-fast atom bombardment (frit-FAB) and continuous-flow FAB mass spectrometry have become standard methods for the analysis of peptides and peptide mixtures, these techniques have not been applied previously to the analysis of oligonucleotides. Mobilephase composition, flow rate, and sample size were optimized for the analysis of oligonucleotides by negative ion frit-FAB mass spectrometry (a type of continuous-flow FAB mass spectrometry). With a mobile phase consisting of methanol/water/triethanolamine (80:20:0.5, v/v/w), flow injection frit-FAB analysis of oligonucleotides showed lower limits of detection compared to standard probe FAB mass spectrometry. For example, in order to obtain a signal-to-noise ratio of 3:1, 38 prnol of d(GTIAAC) were required for frit-FAB mass spectrometry and 62 pmol were required for standard probe FAB mass spectrometry. The largest difference between frit-FAB and standard probe FAB was observed for d(pC)5, for which the limit of detection by frit-FAB was approximately 11-fold lower than by standard FAB mass spectrometry. Adjustment of the mobile phase to pH 7 with trifluoroacetic acid increased the limit of detection (reduced sensitivity) a minimum of sixfold. Equimolar mixtures of two or three oligonucleotides produced deprotonated molecules in identical relative abundances whether analyzed by frit-FAB or standard probe FAB mass spectrometry. Finally, frit-FAB liquid chromatography mass spectrometry was demonstrated by separating mixtures of oligonucleotides on a β -cyclodextrin high-performance liquid chromatography column with a mobile phase containing methanol, water, and triethanolamine.  相似文献   

15.
Conditions are reported for the reverse-phase HPLC analysis of gossypol and of some of its derivatives, including anhydrogossypol, gossypolone, gossypol hexaacetate, and Schiff's base derivatives. It is shown that field desorption (FD) and chemical ionization (CI) mass spectrometry have advantages over electron impact (EI) mass spectrometry for the characterization of these compounds and that combined high-performance liquid chromatography/mass spectrometry (LC/MS), especially when used in the CI mode, is particularly effective.  相似文献   

16.
Atmospheric pressure chemical ionization (APCI) and electrospray (ES) mass spectrometry (MS) in both positive and negative ionization modes coupled to high-performance liquid chromatography (HPLC) have been used for the characterization of monogalactosyl diacylglycerols (MGDG) from cyanobacteria Anabaena cylindrica and Aphanizomenon flos-aquae.  相似文献   

17.
A sensitive and selective high-performance liquid chromatography/atmospheric pressure chemical ionisation tandem mass spectrometry (HPLC/APCI-MS/MS) method for the simultaneous detection of 18 benzodiazepines and metabolites in human blood is described. The procedure utilises butyl chloride extraction at alkaline pH followed by reversed-phase liquid chromatography. The technique is suitable for screening analyses and confirmation of identity of the benzodiazepines at their lowest reported therapeutic concentrations using 500 microL of blood. The method has been successfully applied in forensic cases involving low concentrations of benzodiazepines.  相似文献   

18.
The products arising from the reaction of alpha-protected lysine with glucose have been studied by different techniques, viz. high-performance liquid chromatography (HPLC) with UV detection, fast atom bombardment (FAB) mass spectrometry (MS), and HPLC/MS. Most of the analytical data were obtained by the last approach and allowed identification of many molecular species for a thorough knowledge of possible reaction pathways or structural data already available in the literature.  相似文献   

19.
Harderoporphyrin (2-vinyl-4,6,7-tripropionic acid porphyrin) and its metabolites in faeces of patients with hereditary coproporphyria (HCP) have been separated and characterized by high-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry (HPLC/ESI-Q-TOFMS/MS). The metabolites identified were 2-ethyl-4,6,7-tripropionic acid porphyrin, 2-hydro-4,6,7-tripropionic acid porphyrin, 2-methoxyethyl-4,6,7-tripropionic acid porphyrin and 2-acetyl-4,6,7-tripropionic acid porphyrin. Isomers of harderoporphyrin derived from isomerization of harderoporphyrinogen were also detected.  相似文献   

20.
Steroids comprise a large group of natural substances that must frequently be monitored in various biological materials. Due to the metabolic versatility of steroid molecules, extremely complex mixtures are often encountered, necessitating the use of a chromatographic procedure prior to measurement. In this article we present our work, that is, the development of analyses of biological steroids (especially vitamin D compounds and neurosteroids) using gas chromatography/mass spectrometry, high-performance liquid chromatography (including inclusion chromatography using cyclodextrin) and liquid chromatography/mass spectrometry.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号