首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe an immunochromatographic electrochemical biosensor (IEB) for highly specific and sensitive determination of Hg(II) ions. The IEB is based on the use of a new monoclonal antibody (McAb) against Hg(II) ions that affects the recognition of an antigen. The McAb is placed on the surface of gold nanoparticles (AuNPs) and can recognize the antigen only in the absence of Hg(II) ions. This detection scheme was used to design an immunochromatographic test strip using dually labeled AuNPs along with electrochemical detection. Signal amplification was accomplished by a competitive reaction and the use of horseradish peroxidase. Following immunochromatography, the test zone was cut out and transferred into a reaction cell loaded with a substrate solution containing ortho-phenylenediamine and H2O2. After 10-min incubation with horseradish peroxidase, square wave voltammetry was performed with a screen-printed electrode. Under optimal conditions and a working voltage of ?0.57 V, the IEB displays a linear response in the 0.1 to 200 ng.mL?1 Hg(II) concentration range and a 30 pg.mL?1 limit of detection. It was applied to the determination of Hg(II) in (spiked) waters and milk where its sensitivity by far surpassed the maximum allowed contamination levels. This sensitive IEB therefore possesses substantial advantages over other assays. In addition, the detection scheme may be extended to other metal ions for which appropriate antibodies are available.
Graphical abstract We developed an immunochromatographic electrochemical biosensor (IEB) for highly specific and sensitive determination of Hg(II) ions in water and milk by using a new anti-Hg2+ monoclonal antibody (McAb). The linear range and limit of detection is 0.1–200 ng·mL?1 and 30 pg.mL?1, respectively.
  相似文献   

2.
A screen-printed three-electrode amperometric biosensor based on urease and the nicotinamide adenine dinucleotide hydrogen (NADH)–glutamic dehydrogenase system was developed and applied to the screening of heavy metals in environmental samples. The development of an amperometric sensor for the monitoring of urease activity was feasible by coupling the urea breakdown reaction catalysed by urease to the reductive ammination of ketoglutarate catalysed by glutamic dehydrogenase (GLDH). The ammonia provided by the urea conversion is required for the conversion of ketoglutarate to glutamate with the concomitant oxidation of the NADH cofactor. NADH oxidation is monitored amperometrically at 0.3 V (vs. Ag/AgCl) after urease immobilization onto the screen-printed three-electrode configuration. Immobilization of urease on the surface of screen-printed electrodes was performed by entrapment in alginate gel and adsorption on the electrode in a nafion film. Low sensitivity to inactivation by metals was recorded after urease entrapment in alginate gel with detection limits of 2.9 and 29.8 mg L–1 for Hg(II) and Cu(II), respectively. The use of the negatively charged nafion film created a more concentrated environment of cations in proximity to the enzyme, thus enhancing the urease inhibition when compared to gel entrapment. The calculated detection limits were 63.6 and 55.3 g L–1 for Hg(II) and Cu(II), respectively, and 4.3 mg L–1 for Cd(II). A significant urease inactivation was recorded in the presence of trace amounts of metals (g L–1) when the enzyme was used free in solution. Analysis of water and soil samples with the developed nafion-based sensor produced inhibition on urease activity according to their metal contents. The obtained results were in agreement with the standard methods employed for sample analysis. Nevertheless, the use of the amperometric assay (with free urease) proved more feasible for the screening of trace amounts of metals in polluted samples.  相似文献   

3.
We have developed a fibre optic biosensor with incorporated magnetic microparticles for the determination of biogenic amines. The enzyme diamine oxidase from Pisum sativum was immobilized either on chitosan-coated magnetic microparticles or on commercial microbeads modified with a ferrofluid. Both the immobilized enzyme and the ruthenium complex were incorporated into a UV-cured inorganic–organic polymer composite and deposited on a lens that was connected, by optical fibres, to an electro-optical detector. The enzyme catalyzes the oxidation of amines under consumption of oxygen. The latter was determined by measuring the quenched fluorescence lifetime of the ruthenium complex. The limits of detection for the biogenic amines putrescine and cadaverine are 25–30 μmol?L?1, and responses are linear up to a concentration of 1 mmol L?1.
Figure
Response (fluorescence lifetime) of a novel optical biosensor for biogenic amines (putrescine, cadaverine) determination based on Pisum sativum diamine oxidase immobilized on magnetically responsive chitosan microparticles with entrapped magnetite encapsulated in inorganic–organic polymer ORMOCER® together with ruthenium complex.  相似文献   

4.
For detection of phenolic compounds in environmental water samples we propose an amperometric biosensor based on tyrosinase immobilized in titania sol-gel. The analytical characteristics toward catechol, p-cresol, phenol, p-chlorophenol, and p-methylcatechol were determined. The linear range for catechol determination was 2.2 x 10(-7)-1.3 x 10(-5) mol L(-1) with a limit of detection of 9 x 10(-8) mol L(-1) and sensitivity 2.0 x 10(3) mA mol(-1) L. The influence of sample matrix components on the electrode response was studied according to Plackett-Burman experimental design. The potential interferents Mg(2+), Ca(2+), HCO3(-), SO4(2-), and Cl(-), which are usually encountered in waters, were taken into account in the examination. Cu(2+) was also taken into account, because CuSO(4) is sometimes added to a water sample, as a preservative, before determination of phenolic compounds. It was found that among the ions tested only Mg(2+) and Ca(2+) did not directly affect the electrode response. The developed biosensor was used for determination of catechol in spring and surface water samples using the standard addition method.  相似文献   

5.
A highly selective spectrofluorometric method for the determination of total mercury (Hg) in waste waters is described. Fluorescence quenching of rhodamine B with Hg(II) in the presence of iodide, after a concentration step, is the basis of this sensitive method. All forms of mercury, including organic compounds, are pre-oxidized to ionic mercury by acidic potassium permanganate. The final and complete oxidation is achieved by adding potassium persulphate and heating. Hg(II) was reduced by tin(II) chloride and Hg vapour driven by an air stream into an absorption solution containing potassium permanganate and sulphuric acid, using a closed, recirculating air stream. In this solution fluorescence quenching of rhodamine B at an excitation wavelength of 485 nm and emission wavelength of 586 nm was measured. The recoveries were done by adding 3.0 g Hg/100 ml to each sample before the digestion. It was indicated that the recoveries for determining mercury in waste waters were 98.3%–102.7%. The method gives reliable results down to a concentration of 10 ng Hg/ml waste water.  相似文献   

6.
Summary A routine method for the determination of phthalates in water is presented. It is suitable for all kinds of water like surface water, waste water, landfill leachate, rain water and ground water. Unfiltered water samples including all suspended particulate matter are extracted by solid-phase extraction in an all-glass apparatus using RPC-18. The extracts are measured by GC/MSD in the SIM mode. Due to an easy but efficient decontamination technique, method blanks could be decreased below 0.02 g/l for all phthalates. The detection limits are 0.01 to 0.02 g/l, the determination limits are 0.02 to 0.05 g/l. Recovery for all phthalates is about 98% (±5%). Phthalates were measured in about 400 samples of water of the river Rhine and its main affluents in Northrhine-Westfalia.  相似文献   

7.
A highly selective hybrid way of TXRF determination of mercury(II) in drinking water at the level of n(10–2–100) μg/L is developed. The technique of preconcentration of mercury(II) ions includes directly suspended droplet microextraction with benzene in the form of an iodide molecular complex. The proposed method of determination is characterized by its high degree of sensitivity and reproducibility (c min = 8 ng/L, s r = 0.12 (100 ng/L)). The accuracy of the analysis results is confirmed by the introduced–found method.  相似文献   

8.
If proteome datasets are to be collated, shared, and merged for higher level proteome analyses, there is a need for generally accepted strategies and reagents for optimization and standardization of instrument performance. At present, there is no single protein or peptide standard set that is capable of assessing instrument performance for peptide separation and analysis in this manner. To create such a standard, we have used the recently described QconCAT methodology to generate an artificial protein, QCAL. This protein, a concatenation of tryptic peptides that is expressed in E. coli, provides a stoichiometrically controlled mixture of peptides that are amenable to analysis by all commonly used instrumentation platforms for proteomics.  相似文献   

9.
Summary Trace enrichment on a precolumn packed with copolymer material, coupled on-line with reversed-phase, column liquid chromatography-particle beammass spectrometry (RPLC-PB-MS) has been used for both target and non-target analysis of water samples. RPLC is carried out on a C-18-bonded silica column using a linear acetonitrile-0.1 M ammonium acetate gradient. Using optimised PB-MS conditions and 100–250 ml water samples, the detection limits for several phenylureas are in the 0.03–0.05 g l–1 range using the full-scan mode; repeatability is good and the LC-PB-MS system is robust. Several surface and drinking water samples have been analysed and low levels of various environmental contaminants have been identified using electron impact mass spectra. Applying chemical ionisation with methane as reagent gas in both the positive and negative mode in conjunction with PB-MS provides relevant confirmatory information.  相似文献   

10.
The aromatic peroxygenase (APO; EC 1.11.2.1) from the agraric basidomycete Marasmius rotula (MroAPO) immobilized at the chitosan-capped gold-nanoparticle-modified glassy carbon electrode displayed a pair of redox peaks with a midpoint potential of −278.5 mV vs. AgCl/AgCl (1 M KCl) for the Fe2+/Fe3+ redox couple of the heme-thiolate-containing protein. MroAPO oxidizes aromatic substrates such as aniline, p-aminophenol, hydroquinone, resorcinol, catechol, and paracetamol by means of hydrogen peroxide. The substrate spectrum overlaps with those of cytochrome P450s and plant peroxidases which are relevant in environmental analysis and drug monitoring. In M. rotula peroxygenase-based enzyme electrodes, the signal is generated by the reduction of electrode-active reaction products (e.g., p-benzoquinone and p-quinoneimine) with electro-enzymatic recycling of the analyte. In these enzyme electrodes, the signal reflects the conversion of all substrates thus representing an overall parameter in complex media. The performance of these sensors and their further development are discussed.  相似文献   

11.
Inorganic calcium carbonate precipitation from natural seawater and saline water at various pH values was carried out experimentally. The results show the clear positive relationships between boron concentration and δ11B of inorganic calcium carbonate with the pH of natural seawater and saline water. However, the variations of boron isotopic fractionation between inorganic calcite and seawater/saline water with pH are inconsistent with the hypothesis that B(OH)4- is the dominant spe-cies incorporated into the biogenic calcite structure. The isotopic fractionation factors α between synthetic calcium carbonate precipitate and parent solutions increase systematically as pH increases, from 0.9884 at pH 7.60 to 1.0072 at pH 8.60 for seawater and from 0.9826 at pH 7.60 to 1.0178 at pH 8.75 for saline water. An unusual boron isotopic fractionation factor of larger than 1 in synthetic calcium carbonate precipitated from seawater/saline water at higher pH is observed, which implies that a substantial amount of the isotopically heavier B(OH)3 species must be incorporated preferentially into synthetic inorganic carbonate. The results propose that the incorporation of B(OH)3 is attributed to the formation of Mg(OH)2 at higher pH of calcifying microenvironment during the synthetic calcium carbonate precipitation. The preliminary experiment of Mg(OH)2 precipitated from artificial seawater shows that heavier 11B is enriched in Mg(OH)2 precipitation, which suggests that isotopically heavier B(OH)3 species incorporated preferentially into Mg(OH)2 precipitation. This result cannot be applied to explain the boron isotopic fractionation of marine bio-carbonate because of the possibility that the unusual environment in this study appears in formation of marine bio-carbonate is infinitesimal. We, however, must pay more attention to this phenomenon observed in this study, which accidentally appears in especially natural environment.  相似文献   

12.
The combination of the thermodynamic-integration approach and Widom's particle-insertion method is shown to be appropriate to determine the excess chemical potential of water in dense, amorphous polymer microstructures from MD simulation at an atomistically detailed level. The two-step method is applied to bisphenol-A–polycarbonate (BPA–PC) and polyvinylalcohol (PVA). The results are compared to previously published calculations on water sorption of various polyamides and show the applicability of the two-step method for the calculation of the excess chemical potential of water in a variety of polymer materials to obtain an estimate of their water sorption behavior.  相似文献   

13.
This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h−1. Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 μL s−1. For a concentration range between 0.010 and 0.25 mg L−1, the current (i p, μA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L−1): i p = (−20.5 ± 0.3)C paraquat − (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 μg L−1, respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.  相似文献   

14.
Dielectric barrier discharge (DBD) at atmospheric pressure provides an efficient radiation source for the excitation of bromine and it is used for the first time for optical emission spectrometric (OES) detection of bromide and bromate. A portable DBD–OES system is developed for screening potential pollution from bromide and bromate in environmental waters. Bromide is on-line oxidized to bromine for in-situ generation of volatile bromine. Meanwhile, a helium stream carries bromine into the DBD micro-plasma for its excitation at a discharging voltage of 3.7 kV and optical emission spectrometric detection with a QE65000 charge-coupled device (CCD) spectrometer in the near-infrared spectral region. Similarly, the quantification of bromate is performed by its pre-reduction into bromide and then oxidized to bromine. The spectral characteristics and configuration of the DBD micro-plasma excitation source in addition to the oxidation vapor generation of bromine have been thoroughly investigated. With a sampling volume of 1 mL, a linear range of 0.05–10.0 mg L−1 is obtained with a detection limit of 0.014 mg L−1 by measuring the emission at 827 nm. A precision of 2.3% is achieved at 3 mg L−1 bromide. The system is validated by bromine detection in certified reference material of laver (GBW10023) at mg L−1 level, giving rise to satisfactory agreement. In addition, it is further demonstrated by screening trace bromide and bromate as well as spiking recoveries in a series of environmental water samples.  相似文献   

15.
We report herein the use of p-dodecylbenzenesulfonic acid(DBSA) as a catalyst for a one-pot Biginelli reaction to afford 3,4- dihydropyrimidinone derivatives in good to excellent yields.This reaction proceeds efficiently in water and under solvent free conditions.Comparisons of results indicate that although the yields are high and comparable for both methods,the reaction times are considerably shorter under solvent free conditions.  相似文献   

16.
17.
A recently proposed radically different set of assignments for the infrared and Raman spectra for solid sulphur dioxide have been assessed and rejected because of the misinterpretation of the origin of the lifting of the degeneracy for TO-LO mode pairs in non-centric crystals. The assessement was based on Raman depolarization measurements for oriented single crystals, well established isotope shift values, natural isotope abundance data and Raman measurements with 34S-enriched sulphur dioxide. The reassigned values are consistent with those previously accepted. The assignment of weak peaks due to small concentrations of isotopically different molecules (self-impurities) has been shown to be unexpectedly complicated due to intermolecular coupling between vibrational modes of isotopically different molecules. In the ν2 region of the spectrum the expected band due to the 34SO2 impurity remained invisible even in 34S-enriched samples. In the ν1 and ν3 regions the relative intensity of the band due to 34SO2 was anomalously large due to intermolecular coupling.  相似文献   

18.
In recent years, metal oxide semiconductors have been explored as photocatalysts for the degradation of organic contaminants in water/wastewater. The uniqueness of these oxide materials is in their ability to harness energy in the UV/Vis range, their relative ease of synthesis, low cost, and their general high surface ratio to mass, etc. Thus, these materials have consequently drawn much profound interest in environment applications, particularly pharmaceutical drugs for photocatalytic degradation. Furthermore, the non-toxic nature of most metal oxide semiconductors means they are convenient for water treatment works, resulting in safe drinking water for humans and safe environments for aquatic mammals. Pharmaceuticals are emerging pollutants that are increasingly being found in water systems. They have been detrimental to the human and animal health. In this article, pharmaceutical drugs abatement from water via photocatalysis process using oxide-based advanced metals such as TiO2, ZnO, Fe2O3,WO3, and Bi2WO6 is discussed. Degradation of various drugs at laboratory scale have been assessed and examples cited. Various approaches to metal oxides modifications and synthesis methods to improve degradation efficiency have also been discussed. Effects of experimental/operational parameters in the degradation process have been compiled and compared. Finally, a short preview of degradation of pharmaceuticals pilot scales is also highlighted.  相似文献   

19.
Chemical analysis of various biological matrices is routinely used for assessment of human exposure to various toxic metals. In this work, 489 samples of urinary calculi originating from almost the whole of The Czech Republic, were collected and subjected to mineralogical and elemental analysis. This study was aimed at mercury, the content of which was determined using thermo-oxidation — cold vapor — atomic absorption spectrometry. The effects of mineralogical composition, sex, age and region were recorded in order to verify the applicability of urinary calculi for biomonitoring. Relationships with other minor and trace elements were also investigated. Association of mercury with whewellite mineral was observed as well as a remarkable relationship with selenium, confirming the role of selenium in mercury excretion. No statistically significant effect was observed on the mercury content in stones with regard to the sex or region. Median values in age groups follow a trend with the maximum median value 0.365 mg kg?1 in the group of 41–50 year old donors, decreasing to 0.060 mg kg?1 for the oldest group (81–92 years). Our results confirm that urinary calculi can be helpful in providing complementary information on human exposure to mercury and its excretion.
  相似文献   

20.
To investigate the effects of mercury species intoxication and to test the efficiency of different commonly applied antidotes, human whole blood and plasma surrogate samples were spiked with inorganic mercury (Hg2+) and methylmercury (MeHg+, CH3Hg+) prior to treatment with the antidotes 2,3-dimercaptopropan-1-ol (British Anti Lewisite), 2,3-dimercaptosuccinic acid (DMSA), and N-acetylcysteine (NAC). For mercury speciation analysis in these samples, liquid chromatography was coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). Adduct formation between mercury species and physiological thiols (cysteine and glutathione) was observed as well as the release of glutathione under treatment with the antidotes DMSA and NAC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号