首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Thiocyanate traces have a strong inhibitory effect on the oxidation of Neutral Red by potassium bromate under UV irradiation in diluted phosphoric acid. Neutral Red exhibits a sensitive second derivative oscillopolarographic wave at –0.6 V(vs. SCE) in diluted phosphoric acid and sodium acetate solution. The oscillopolarographic behavior of Neutral Red was selected as indicator component for its photo-activated oxidation. The photochemical reaction rate equation was determined. A detection limit of 0.3 ng mL–1 (3σ/k) and a linear calibration curve from 2.0–48.0 ng mL–1 thiocyanate were obtained. The method was applied to the determination of thiocyanate in urine, saliva and serum with satisfactory results.  相似文献   

2.
Zhi-Liang J 《Talanta》1991,38(6):621-625
The oscillopolarographic behaviour of Methyl Red in sodium hydroxide medium has been studied, and the results show that the wave at -0.79 V is an irreversible two-electron adsorption wave. A very sensitive and selective catalytic reaction-oscillopolarographic method for the determination of Ru down to 3 ng/l. is described, based on the Ru(III)-catalysed redox reaction of Methyl Red and potassium periodate in hydrochloric acid medium. Potassium thiocyanate is used to quench the reaction and the oscillopolarography is then performed with sodium hydroxide as the supporting electrolyte. The influence of 41 foreign ions has been examined. Ruthenium in ore samples has been determined by the method, with satisfactory results.  相似文献   

3.
研究了在0.1 mol/L H3PO4介质中,活化剂抗坏血酸的作用下,V(Ⅴ)催化KClO3氧化甲基红褪色的指示反应,由此建立了一种测定痕量V(Ⅱ)的催化动力学光度新方法。研究了影响该催化褪色反应的因素。方法的线性范围为0.09~7.0 ng/mL,检出限为2.9×10-2 ng/mL。方法用于实际样品的测定。  相似文献   

4.
A highly sensitive and selective catalytic method with 2.5-order differential oscillopolarographic detection is described for the determination of tellurium, based on its activation effect on the slow Pd(II)-catalyzed reaction of sodium hypophosphite and methyl red in hydrochloric acid medium at 100 degrees C. Methyl red exhibited a sensitive 2.5-order differential polarographic wave at -0.35 V (vs. SCE) in the supporting electrolyte of pH 5.0 acetate buffer solution and was chosen as the indicating component for the indirect determination of tellurium. A calibration curve of tellurium in the range of 0.02-2.0 ng mL(-1) was obtained by the fixed-time procedure. The detection limit was 0.007 ng mL(-1). Possible interferences by co-existing substances were examined. The new method has been used to analyze trace tellurium in organs of white mice with satisfactory results. RSD was 0.54% to 2.10%, recovery 98.4% to 95.7%. The mechanism is also discussed.  相似文献   

5.
A reversed-phase high-performance liquid chromatographic method with electrochemical detection for the quantitative determination of diclofenac potassium in plasma was developed. Naproxen was used as the internal standard. The drug and internal standard were isolated from plasma by extraction with dichloromethane and 2 M hydrochloric acid. Chromatographic separation was performed on a C18 column with methanol-water (68:32, v/v) adjusted to pH 3.2 with phosphoric acid as mobile phase. The oxidation potential for detection was established by constructing a voltammogram for diclofenac. The quantification limit for diclofenac in plasma was 5 ng mL(-1). Linearity of the method was confirmed in the range 5-2000 ng mL(-1), correlation coefficient 0.9998. Within-day relative standard deviations (RSDs) ranged from 0.66 to 14.00% and between-day RSDs from 0.59 to 15.78%. The method was successfully applied for the determination of pharmacokinetic parameters after ingestion of a 50 mg dose of diclofenac. Studies were performed on 18 healthy volunteers of both sexes.  相似文献   

6.
A kinetic spectrophotometric method for measuring thiocyanate is described. The proposed method is based on the inhibitory effect of thiocyanate on the oxidation of Methyl Red by bromate in the presence of nitrite, which was monitored at 520 nm. The variables affecting the rate of the reaction were investigated and the optimum conditions were established. Thiocyanate can be measured in the range of 0.05-1.1 microg ml(-1) with a detection limit of 0.025 microg ml(-1). This method has been used to determine trace thiocyanate in urine and tap water samples.  相似文献   

7.
荧光动力学法测定唾液中痕量硫氰根   总被引:2,自引:0,他引:2  
人体内的SCN-主要分布于人体体液及代谢物中,如唾液、血浆、尿液等。其来源主要有两种途径:一是烟草中氰化物的代谢产物,人体内硫氰酸盐的含量是区别吸烟者和不吸烟者的重要标志[1,2];二是某些食物的代谢产物,如卷心菜等。硫氰酸盐可作为药物用于治疗甲状腺疾病,但体液中SCN-含  相似文献   

8.
An analytical procedure has been developed for the analysis of benzoic acid, p-hydroxybenzoic acid, methyl-, ethyl-, propyl-, isopropyl-, and butyl esters of p-hydroxybenzoic acid by micellar liquid chromatography. After dilution in n-propanol the sample was directly injected onto a Lichrosorb ODS, 5 microm (250 x 4.6 mm ID) column and eluted with aqueous 2% Brij-35 adjusted to pH 3.0 with phosphoric acid:propanol (80:20 v/v) at a flow rate of 1 mL min(-1) and UV detection at 254 nm. A linear calibration curve was obtained simultaneously for each component in the range of 50-500 microg mL(-1) for benzoic acid and 5-150 microg mL(-1) for the other components; detection limits were within 25-250 ng mL(-1) corresponding to 125-1250 pg per injection (5 microL). The reproducibility in terms of average peak area and average retention time was obtained with coefficients of variation (CV) of 1.2% and 0.5%. The method was applied to analysis of these compounds in cosmetics (shampoos, hand lotions, creams, and bath foam) and food samples.  相似文献   

9.
In dilute phosphoric acid solution, cadmium (II) reacts with a large excess of I- to form [CdI4]2- which reacts further with basic triphenylmethane dyes such as crystal violet (CV), ethyl violet (EV), methyl violet (MV), brilliant green (BG) or malachite green (MG) to form an ion-association complex. This results in a significant enhancement of resonance Rayleigh scattering (RRS) intensity and the appearance of new RRS spectra. The characteristics of RRS spectra of the ion-association complexes, the influencing factors and the optimum conditions of these reactions have been investigated. The intensity of RRS is directly proportional to the concentration of cadmium from 0 to 60 ng mL(-1) for EV and MV systems, 0 to 80 ng mL(-1) for CV system, and 0 to 100 ng mL(-1) for BG and MG systems. The methods exhibit high sensitivities and the detection limits for cadmium are between 0.35 and 2.00 ng mL(-1) depending on the different reaction systems. The new RRS method was applied to the direct determination of traces of cadmium in pure zinc and synthetic water samples.  相似文献   

10.
Chiang HY  Sheu SJ 《Electrophoresis》2004,25(4-5):670-676
Two stacking methods of capillary electrophoresis (CE) were developed for the separation of very dilute solutions of ephedra-alkaloids, namely ephedrine, pseudoephedrine, methylephedrine, methylpseudoephedrine, norephedrine, and norpseudoephedrine. A sweeping method which uses a carrier comprised of phosphoric acid, sodium dodecyl sulfate (SDS), diethylamine and acetonitrile permits the detection of the alkaloids down to the 10(-1) microg/mL level, and the cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) method using phosphoric acid, SDS, and acetronitrile as electrolytes can detect down to the 10(-3) microg/mL level. The former requires the conductance of the sample solution to be adjusted beforehand, and only five peaks were observed, two of which were overlapped. The latter is capable of separating the six alkaloids but has a somewhat poorer reproducibility. Using an optimized injection time, it was found that the more diluted a solution is, the greater the sweeping effect will be. The CSEI-Sweep-MEKC method with a 600 s injection time and a 10(-1) microg/mL solution concentration provides an amplification effect of approximately 10(4). The method is suitable for analyses of dilute herb drug extracts and mouse sera. The effect of buffers on the separation and validation of the methods in this study are also discussed.  相似文献   

11.
For the first time, a fast, high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of the new ultra-short hypnotic HIE-124 and its metabolite in mice serum. Each compound, together with carbamazepine (internal standard) was extracted from the serum matrix using liquid-liquid extraction (LLE). Chromatographic resolution of the analytes was performed on a Chromolith Speed Rod monolithic silica column (100 mm × 4.6 mm i.d.) under isocratic conditions using a mobile phase of 65:35 (v/v), 20 mM phosphate buffer (pH 7.0 adjusted with phosphoric acid)-acetonitrile. The elution of the analytes were monitored at 240 nm and conducted at ambient temperature. Because of high column efficiency the mobile phase was pumped at a flow rate of 2.5 mL min(-1). The total run time of the assay was 2 min. The method was validated over the range of 60-2000 ng mL(-1) for HIE-124 and 200-1600 ng mL(-1) for the metabolite (r(2) = 0.99). The limit of detection (LOD) for HIE-124 and its metabolite were 20 ng mL(-1) and 65 ng mL(-1), respectively. The proposed method was validated in compliance with ICH guidelines, in terms of accuracy, precision, limits of detection and quantitation and other aspects of analytical validation. The developed method could be used for the trace analyses of HIE-124 and its metabolite in serum and was finally used for the pharmacokinetic study investigation of HIE-124 in mice serum.  相似文献   

12.
A simple, selective and rapid method for solid phase extraction and spectrophotometric determination of thiocyanate using a manganese (III) tetrakis (p-sulfonatophenyl) porphyrin, [Mn (TPPS) OAC] bound to Amberlite IR-400 has been developed. The influence of pH, amount of solid phase, sample matrix, type and amount of eluting agent and flow rates i.e. variables affecting the efficiency of the extraction system were evaluated and conditions of the sample, eluting solution and active phase were optimized. The maximal capacity was found to be as 1.16 microg mL(-1) for 1200 mL. Thiocyanate ions can be eluted quantitatively with 8 mL 0.3 M ferric chloride. The enrichment factor was 150. The linear range of the determination is between 0.4-2.0 microg mL(-1) for preconcentration method with a limit of detection of 2.8 ng mL(-1). The method has been successfully applied for determination of trace amounts of thiocyanate in tap water, saliva sample and a synthetic mixture.  相似文献   

13.
A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was used. Clenbuterol was eluted using 1% trifluoroacetic acid in methanol, which was evaporated and reconstituted in buffer. Results from the HPLC analyses showed that the extraction of clenbuterol using MIP is linear in the range 0.5-100 ng/mL with good precision (4.3% for 0.6 ng/mL and 2.1% for 6.0 ng/mL) and accuracy (96.7% for 0.6 ng/mL and 96.7% for 6.0 ng/mL). The recoveries were 75%. The results show that the method offers a selectivity and sensitivity that make the quantitation of 0.5 ng clenbuterol/mL urine by HPLC-UV possible and a competitive alternative to state-of-the-art routine analytical methods.  相似文献   

14.
《Analytical letters》2012,45(14):2887-2897
ABSTRACT

A flow-injection catalytic spectrophotometric method is proposed for the determination of nitrite based on its catalytic effect on potassium bromate oxidation of acridine orange in phosphoric acid medium. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of acridine orange at 491.5 nm coupling with the stopped-flow technique. The calibration curve was linear between 3.4 and 65 ng/mL, and the detection limit was 2.2 ng/mL. Up to 30 samples can be analyzed per hour with a relative precision of ca. 1.9%. The proposed method was successfully applied to the determination of nitrite in waters and food samples with satisfactory results.  相似文献   

15.
Chawla KL  Tandon JP 《Talanta》1966,13(4):545-550
Methods for the standardisation of vanadium(II) sulphate are described. With weak oxidising agents, e.g., Fe(III)/Fe(II) in phosphoric acid, vanadium(II) undergoes a one-electron change, which is satisfactorily indicated by Neutral Red, Phenosafranine or Safranine T, or by potentiometry. Stronger oxidising agents oxidise vanadium(II) to vanadium(IV); Variamine Blue, Methylene Blue, o-dianisidine, cacotheline, ferroin, bis(alpha,alpha'-bipyridyl)iron(II) and ammonium molybdate are satisfactory indicators. Binary mixtures of oxidising agents can be determined.  相似文献   

16.
荧光动力学法测定痕量硫氰根离子的研究   总被引:12,自引:0,他引:12  
本文利用痕量硫氰根离子对溴酸钾氧化罗丹明6G反应的抑制作用,建立了痕量硫氰根离子的荧光动力学检测方法。方法检测限0.4ng/mL。线性范围0.4-32.0ng/mL。应用于吸烟人和非吸烟人唾液、湖水、血清中痕量硫氰根离子的测定,结果令人满意。  相似文献   

17.
A high performance liquid chromatographic method was developed for the simultaneous assay of R(-)- and S(+)-albuterol in human serum. The assay involves solid phase extraction as a sample clean-up step and derivatization of racemic albuterol to its diastereomeric thioureas with 2,3,4,6-tetra-O-acetyl-alpha-D-glucopyranosyl isothiocyanate. Chromatographic separation was accomplished under isocratic conditions using an octadecylsilane column and a mobile phase consisting of 29:71 acetonitrile:distilled water containing 0.1% triethylamine, pH 4.0 (adjusted with concentrated phosphoric acid) at a flow rate of 0.8 mL/min. The diastereomers were detected using a fluorescence detector set at 223 nm excitation and no emission filter. Racemic bamethane was used as internal standard. Drug to internal standard peak-height ratios were linear over a 2-20 ng/mL range for each enantiomer. The limit of detection of each analyte was 1.0 ng/mL (S/N = 3).  相似文献   

18.
The electrochemical regeneration of nicotinamide adenine dinucleotide (NAD+/NADH) has been one of the central subjects of bioelectrochemistry during past three decades. We report on the unique chemical electrocatalyst for NAD+/NADH regeneration based on electropolymerized Neutral Red. Using poly(Neutral Red) modified electrodes, the reversible polarographic waves of nicotinamide adenine dinucleotide reduction–oxidation and the equilibrium (NAD+/NADH) potential were observed. This was impossible using all known catalytic and mediator systems. The unique poly(Neutral Red) based electrocatalyst allowed us to determine the standard (NAD+/NADH) potential more precisely (E≅0.59 V SCE, pH 6.0).  相似文献   

19.
催化动力学光度法测定痕量钯   总被引:16,自引:0,他引:16  
张志琪  郑行望 《分析化学》1995,23(11):1326-1328
在磷酸-磷酸二氢钾缓冲溶液中,以钯(Ⅱ)催化次磷酸钠还原罗丹明B褪色为指示反应,建立了痕量钯的动力学光度分析新方法。在金(Ⅱ)的存在下,检测下限达5×10^-11g/mL钯(Ⅲ),方法应用于模拟合金样和含钯分子筛中钯的测定。结果满意。  相似文献   

20.
Rapid, selective, and sensitive methodology for the quantification of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in human plasma using packed capillary liquid chromatography coupled to electrospray ionization ion-trap mass spectrometry has been developed. Plasma proteins were precipitated using acetonitrile and the resulting supernatant was diluted 1+1 with water containing 10 mM ammonium acetate (NH4Ac) prior to injection. Sample volumes of 250 microL were loaded onto a 30 mm x 0.32 mm ID 10 microm Kromasil C18 precolumn by a carrier solution consisting of 10 mM NH4Ac in ACN/H2O (5/95, v/v) at a flow rate of 100 microL/min, providing on-line analyte enrichment and sample clean-up. Backflushed elution onto a 100 mm x 0.32 mm ID 3.5 microm Kromasil C18 analytical column was conducted using an ACN/H2O solvent gradient containing 10 mM NH4Ac. In order to improve the robustness and performance of the method, perfluoroheptanoic acid (PFHA) was used as internal standard. Separation and detection of PFOA, PFHA, and PFOS were achieved within 10 minutes. Ionization was performed in the negative mode in the m/z range 250-550. The method was validated over the concentration range 1-200 ng/mL for PFOA and over the range 5-200 ng/mL untreated plasma for PFOS, yielding correlation coefficients of 0.997 (PFOA) and 0.996 (PFOS), respectively. The within-assay (n = 6) and between-assay (n = 6) precisions were in the range 2.1-9.2 and 5.6-12%, respectively. The concentration limits of detection (cLOD) of PFOA was 0.5 ng/mL while the cLOD of PFOS was estimated to be 0.2 ng/mL in untreated plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号