首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
The elemental analysis of south Indian gallstones has been carried out using energy dispersive X-ray fluorescence (EDXRF) spectroscopy. A number of important elements including Fe, Cu, Zn, Br, and Pb were estimated from the EDXRF spectra. The results are presented and discussed.  相似文献   

2.
It was proved that non-destructive and non-sampling methods were used to analyze the composition of the archaeological glasses. Glass has been used in ornaments and decoration in Thailand for thousands of years. In this study, glass bead fragments found from the archaeological site at Khao Sam Kaeo, Chumphon Province, southern Thailand were analyzed by the proton induced X-ray emission spectroscopy (PIXE) and scanning electron microscope coupled with energy dispersive X-ray fluorescence spectroscopy (SEM?CEDS). The composition analysis showed that copper was mainly presence as the colorant. Titanium, common impurity in sand, was all present in the glass bead samples. Furthermore, this type of glass almost spread over the various sites in this region that demonstrated the long distance or exchange connections. Finally, PIXE and SEM?CEDS have been used to be the efficient techniques to analyze the archaeological objects, especially the glassy materials, to understand their characteristics and how they were produced in ancient times.  相似文献   

3.
The components of the rock, the pigments, the gold foils and the adhesive of One Thousand Hand Buddha in Dazu stone sculptures, Chongqing, China, have been analyzed by X-ray diffraction (XRD), X-ray fluorescence (XRF), infrared spectroscopy (IR), energy dispersive X-ray analysis (EDX) and fiber optics reflectance spectroscopy (FORS). Furthermore, the weathering and degeneration of One Thousand Hand Buddha have been discussed and the protective methods have been provided. In this work some useful information to study on conservation of stone relics is given.  相似文献   

4.
Specific features of elemental composition analysis of silicon carbonitride thin films by energy dispersive spectroscopy (EDS) are considered. The films were preliminarily examined by IR spectroscopy, X-ray photoelectron spectroscopy (XPS), scanning electron (SEM) and atomic force microscopy (AFM), and X-ray diffraction analysis using synchrotron radiation (SR-XRD) to acquire data on their chemical and phase composition, crystalline structure and surface morphology. The effect of film thickness, substrate material and electron beam energy on the results of energy dispersive analysis was investigated.  相似文献   

5.
Glasses have been used as ornamental and decorative objects in Thailand for several hundred years as seen in archaeological artifacts, such as glass beads found throughout the regions. Decorative glasses can generally be seen as architectural components in Buddhist temples and old-styled palaces. They came in various colors ranging from transparent to amber, blue, green and red of different shades and tones. Fragments of archaeological glass samples were characterized for the first time using Raman spectrophotometer with the aim of obtaining information that would lead to the identification of the glass samples by means of laser scattering. The samples were also investigated using other techniques, such as proton induced X-ray emission spectroscopy, scanning electron microscopy cooperated with energy dispersive X-ray fluorescence spectrometer and synchrotron radiation to induced X-ray fluorescence. The results showed that they were mostly lead-silica based glasses whose colors were induced by metal ions. The differences in chemical compositions were confirmed by Raman signature spectra.  相似文献   

6.
Two representative titaniferous magnetite samples procured from Moulabhanj, Orissa, India have been studied by PIXE, EDXRF, Mössbauer spectroscopy, and XRD techniques. Major iron-bearing phases identified in the samples by Mössbauer spectroscopy and XRD are magnetite, hematite, ferrous ilmenite and ferric ilmenite. The Fe2+/Fe3+ ratio and the relative percentages of different minerals were determined from the resonance areas of Mössbauer spectra. Quantitative multielemental analysis was carried out by energy dispersive X-ray fluorescence (EDXRF) and proton induced X-ray emission (PIXE). Nineteen minor and trace elements have been quantified by EDXRF whereas by PIXE eighteen elements have been analyzed quantitatively. Concentrations of trace elements determined by EDXRF and PIXE were used in interpreting the physico-chemical condition of the depositional basin.  相似文献   

7.
The composition of rock-painting pigments from Egypt (Gilf Kebia area) has been analyzed by means of molecular spectroscopy such as Fourier transform infrared and micro-Raman spectroscopy and scanning electron microscopy coupled to an energy dispersive X-ray spectrometer and X-ray fluorescence analysis. Red and yellow pigments were recognized as red and yellow ochre with additional rutile.  相似文献   

8.
The paper discusses the possibilities of energy dispersive X-ray fluorescence spectroscopy and instrumental neutron activation analysis in the investigation of environmental pollutions. The X-ray fluorescence spectroscopy of samples was performed using the MECA-1044A analyzer (XR-500, LINC SYSTEMS, Great Britain) with a pulsed X-ray tube with a silver target as a source of excitation. Neutron activation analysis was carried out on the basis of two reactors: IBR-2 LNP JINR, Dubna, and TWR ITEP, Moscow. The optimal regimes of measurement for both methods as well as the detection limits corresponding to these regimes are given. To illustrate the perspectives of the methods, the ecological problem of the consequences of introducing into soil of the now available meliorator CaSO4·2H2O is solved in the paper. Data on absorption of trace elements in a wide range including rare-earth elements by agricultural plants are presented. This paper may be of interest for specialists in analytical chemistry and ecology.  相似文献   

9.
Wide band gap transparent polymer-inorganic (PVA-ZnO) composite thin films were prepared by the dip-coating method. Functional groups and metal oxide vibrations were found from Fourier transform-infrared spectroscopy. The elements Zn and O were confirmed from energy dispersive X-ray spectroscopy. The X-ray diffraction patterns revealed that the sharp diffraction peaks correspond to the hexagonal wurtzite structure of ZnO in the PVA matrix. Scanning electron microscopy images showed that the ZnO nanoparticles are randomly distributed throughout the entire film surface. The optical study reveals that the transmittance was more than 85% with very low absorption and wide band gap energy (4.03 to 3.95 eV). The obtained results indicate that the high transmittance, very low absorption, and wide band gap energy of the prepared dip-coated composite thin films make them suitable for use in transparent optoelectronic device applications in the near future.  相似文献   

10.
Energy dispersive X-ray fluorescence studies on determination of thorium (in the range of 7 to 137 mg/mL) in phosphoric acid solutions obtained by dissolution of thoria in autoclave were made. Fixed amounts of Y internal standard solutions, after dilution with equal amount of phosphoric acid, were added to the calibration as well as sample solutions. Solution aliquots of approximately 2–5 µL were deposited on thick absorbent sheets to absorb the solutions and the sheets were presented for energy dispersive X-ray fluorescence measurements. A calibration plot was made between intensity ratios (Th Lα/Y Kα) against respective amounts of thorium in the calibration solutions. Thorium amounts in phosphoric acid samples were determined using their energy dispersive X-ray fluorescence spectra and the above calibration plot. The energy dispersive X-ray fluorescence results, thus obtained, were compared with the corresponding gamma ray spectrometry results and were found to be within average deviation of 2.6% from the respective gamma ray spectrometry values. The average precision obtained in energy dispersive X-ray fluorescence determinations was found to be 4% (1σ). The energy dispersive X-ray fluorescence method has an advantage over gamma ray spectrometry for thorium determination as the amount of sample required and measurement time is far less compared to that required in gamma ray spectrometry.  相似文献   

11.
Aluminosilicate clay samples were analyzed for the constituent elements with respect to a certified reference material using microcrystalline cellulose powder as a binder for presentation as a pressed pellet to an energy dispersive X-ray fluorescence spectrometer. Sample preparation for presentation is highlighted. The data manipulation to achieve the analytical accuracy from the inherent precision is discussed.  相似文献   

12.
Energy dispersive X-ray fluorescence spectroscopy is employed to determine the concentration of nineteen elements in seven profiles representing the aridisols and vertisols groups from agricultural plains of Sudan. A significant variation in the concentration of alkaline and alkaline earth elements in the different regions is observed, which is discussed in relation to the texture of the soil and climatic factors. Uranium, determined by the delayed neutron technique, is observed to increase with depth in one area.  相似文献   

13.
Nigerian and Kenyan clays were analysed using energy dispersive X-ray fluorescence (EDXRF) technique and thirteen elements (Ca, Ti, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Zr, Nb and Pb) were detected. The health implications, since the substance is mostly consumed by pregnant women in both countries, are also reviewed and discussed.  相似文献   

14.
Electron beam induced quantitative X-ray mapping has become a very useful characterisation tool for determining the elemental distribution in materials, whether using energy dispersive spectroscopy or wavelength dispersive spectroscopy. The X-ray intensity distributions of the elements from an X-ray map allow us to generate two dimensional and ternary scatter diagrams thus converting spatial information into concentration dimensions, which is an important tool for displaying the spatial relationships of elements or correlated elements (phases) in materials. To best understand how to use this tool, we need to understand the production and features of the scatter diagram. The type of clustering observed in the scatter diagram, whether oval, linear or spherical, can give the major and trace element distributions within phases as well as qualitative and quantitative phase information. This paper demonstrates the generation of scatter diagrams, properties of scatter diagrams, interpretation of scatter diagrams and the advantages of scatter diagrams through the use of examples.  相似文献   

15.
Three different analytical methods for the determination of strontium and yttrium in Venezuelan latterites by radioisotope induced X-ray fluorescence are compared, also with results from conventional wavelength dispersive X-ray fluorescence. The samples analyzed were from Cerro Impacto, Venezuela. The photon-induced energy dispersive X-ray fluorescence system consisted of a109Cd (7 mCi) source for excitation of the characteristic K X-rays for strontium and yttrium. The detection system employed a high resolution Si(Li) detector and was completely controlled by a PDP-11/05 processor. Of the three analytical methods described, the internal standard-thin film technique was shown to be slightly superior to the conventional standard calibration curve method and the standard additon/dilution procedure. This can be explained by considering the effectiveness of the compensation of the sources of errors by these methods. It should also be noted that in the case of wavelength dispersive X-ray fluorescence, an about 5–10 times greater sample is needed, which is a limitation compared to energy dispersive X-ray fluorescence in some cases. Finally, typical relative standard deviations of the energy dispersive X-ray fluorescence methods were about 10–15% for the range of about 100–100 ppm of strontium and yttrium; these values are acceptable considering the large degree of heterogeneity in this type of geological material. This project was funded by Consejo Nacional de Investigaciones Científicas y Technológicas (CONICIT) and performed as part of UNESCO's IGCP-129 “Lateritization Processes” project.  相似文献   

16.
为建立一种快速且无损检验热敏纸的科学有效的方法,利用能量色散型X射线荧光光谱(XRF)对38个不同商家,不同规格的热敏纸样品进行检验,首先根据每个样品所测量得到的元素的不同,将38个样品分成四大类,同时采用SPSS25.0软件中的系统聚类法对38个样品的元素数据进行聚类分析处理,结果分成了12小组,再结合SPSS25.0软件中的判别分析法对上述结果进行验证,实现了基于X射线荧光光谱结合聚类分析建立数学模型用于区分热敏纸种类的目的,该方法简单易行,可以为案件侦破提供线索、指明方向。  相似文献   

17.
X-ray fluorescence energy dispersive analysis is applied for the determination of Ta and W in sintering compounds. The combination of selective excitation and very simple mathematical procedures permits the determination of the concentrations of the two adjacent elements /Ta and W/ even when the sample contains only few per cent of Ta. Other possible applications are shown.  相似文献   

18.
Silicon and phosphorus contents in polished and unpolished rice planted in a district of high incidence of amyotrophic lateral sclerosis (ALS) have been determined by neutron activation and X-ray fluorescence methods, and compared with those from control areas. In the neutron activation analysis, beta-ray spectra of 32P produced by the 31P(n, gamma)32P reaction on polished and unpolished rice were measured with a low background beta-ray spectrometer. In the X-ray fluorescence analysis, characteristic X-rays were analyzed with a wavelength dispersive X-ray fluorescence spectrometer. Silicon contents in polished and unpolished rice from the ALS area are 42 micrograms.g-1 and 370 micrograms.g-1, respectively, and the corresponding phosphorus contents are 1,210 micrograms.g-1, and 3,370 micrograms.g-1, respectively. The data for ALS area are equal to those for the control area within standard deviation.  相似文献   

19.
The elemental content of different rubber samples was analyzed using different analytical methods (inductively coupled atomic emission spectroscopy and non-polarized energy dispersive X-ray fluorescent spectroscopy). A new application of energy dispersive X-ray spectrometry as an analytical method for the determination of elemental content of rubber samples was investigated. Control analyses were also carried out to compare the results by ICP-AES. In one hand four samples contained same quality of elements (Mg, Si, P, S, Ca, Fe, Zn), while another four samples were without phosphorous. On the other hand there were significant differences in the ratio of C/H in the case of each sample. Based on the results, it was concluded that the X-ray spectrometry as an analytical method is well-applicable to determine the elemental composition of rubber samples, but the calibration is a key part of the analysis. A good correlation was observed between the different methods, but the correlation was the function of characteristic of matrices. Significant matrix effect from the presence of phosphor was observed in the case of some samples, while the change of C/H ratio could not result notable matrix effect.  相似文献   

20.
应用溶胶凝胶法制备不同焙烧温度的氧化物阳极涂层,SEM,EDX,XRD、强化电解寿命、循环伏安和电化学阻抗等测试表明,烧结温度对阳极涂层的表面形貌以及电化学性能有着很大的影响.随着烧结温度的升高,析氯电位相应增加,寿命相对较长,循环伏安电量与双电层电容值有所下降.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号