共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and specific liquid chromatography–tandem mass spectrometry (LC–MS–MS) method was developed and validated for the quantification of poricoic acid A (PAA) in rat plasma. The plasma samples were precipitated by protein precipitation with methanol. Glycyrrhetic acid was used as the IS. Chromatography was performed on a Dionex C18 120 Å (4.6 × 250 mm, 5 μm) column with the mobile phase composed of acetonitrile–water (90:10, v/v) at a flow rate of 0.8 mL min?1. A tandem mass spectrometer equipped with an ESI source was used as the detector and was operated in the negative ion mode. Quantification was performed using multiple reaction monitoring (MRM) of the transitions m/z 497.4 → 423.3 and m/z 469.2 → 425.1 for PAA and IS, respectively. The calibration curves were linear over the range of 5–5,000 ng mL?1 (r 2 = 0.9966) and the lower limit of quantification (LLOQ) was 5 ng mL?1. In this range, RSDs were <10% for intra-assay and inter-assay precisions. The accuracy expressed by deviation (DEV) was <6%, and the extraction recoveries of QC samples were >78%. The validated method was successfully used to study the pharmacokinetics of PAA in rats after intravenous administration at a dose of 1.0, 2.5 and 5.0 mg kg?1 and oral administration at a dose of 25, 50 and 100 mg kg?1, respectively. The relative bioavailability of PAA in rats following oral administration was achieved. 相似文献
2.
3.
Xiangyong Cui Mengliang Zhang Xin Guan Lei Yin Yantong Sun J. Paul Fawcett Jingkai Gu 《Chromatographia》2011,73(1-2):165-169
A highly sensitive liquid chromatography–tandem mass spectrometry (LC–MS–MS) method for the determination of troxerutin in human plasma using tramadol as internal standard (IS) has been developed and validated. Sample preparation involved liquid–liquid extraction with ethyl acetate–isopropanol (95:5, v/v). The analyte and IS were separated by RP–LC with gradient elution using 10 mM ammonium acetate containing 0.1% formic acid and methanol at a flow rate of 0.9 mL min?1. LC–MS–MS in the positive ion mode employed multiple reaction monitoring of the transitions at m/z 743.2→435.3 and m/z 264.1→58.0 for troxerutin and IS, respectively. The assay was linear in the concentration range 0.01–10 ng mL?1 with precision and accuracy within assay variability limits as per FDA guidelines. The assay was successfully applied to a pharmacokinetic study involving oral administration of 300 mg troxerutin to eight healthy Chinese volunteers. 相似文献
4.
A sensitive and selective liquid chromatography–tandem mass spectrometry method for the determination of memantine was developed and validated over the linearity range 0.1–25 ng mL?1 with 0.5 mL of plasma using procainamide as the internal standard. This analysis was carried out on a Cosmosil 5C18-MS column and the mobile phase was composed of methanol: 0.5% formic acid (50:50, v/v). Detection was performed on a triple–quadrupole tandem mass spectrometer using positive ion mode electrospray ionization and quantification was performed by multiple reaction monitoring mode. The MS–MS ion transitions monitored were m/z 180 → 107 and 236 → 163 for memantine and procainamide, respectively. The between- and within-day precision was less than 10.9% and accuracy was less than 2.5%. The lower limit of quantification (LLOQ) was 0.1 ng mL?1. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of memantine in healthy Chinese volunteers. 相似文献
5.
A rapid and simple high-performance liquid chromatographic tandem mass spectrometric method has been developed and validated for analysis of strictosamide in rat plasma. Chromatographic separation was achieved on a C18 column by gradient elution with mixtures of methanol, water, and acetonitrile containing 0.05% acetic acid. Digoxin was used as internal standard. Selected reaction monitoring (SRM) was used for MS quantitation. Linearity was good in the range 0.05–20 ng mL?1 in rat plasma. The lower limit of quantitation was 0.04 ng mL?1. The method is precise and reliable and can be applied to pharmacokinetic studies. 相似文献
6.
Dian-Lei Wang Yan Liang Lin Xie Tong Xie X. T. Wang Sen Yu Guang-Ji Wang Xiao-Dong Liu 《Chromatographia》2008,67(3-4):219-224
To evaluate the pharmacokinetics of a novel analogue of ginkgolide B, 10-O-dimethylaminoethylginkgolide B (XQ-1) in rat plasma in pre-clinical studies, a sensitive and specific liquid chromatographic
method with electrospray ionization mass spectrometry detection (LC–ESI–MS) was developed and validated. After a simple extraction
with ethyl acetate, XQ-1 was analyzed on a Shim-pack C18 column with a mobile phase of a mixture of 1 μmol L−1 ammonium acetate containing 0.02% formic acid and methanol (55:45, v/v) at a flowrate of 0.3 mL min−1. Detection was performed in selected ion monitoring (SIM) mode using target ions at [M + H]+
m/z 496.05 for XQ-1 and m/z 432.10 for the internal standard (lafutidine). Linearity was established for the concentration range from 2 to 1,000 ng mL−1 . The extraction recoveries ranged from 86.0 to 89.9% in plasma at concentrations of 5, 50, and 500 ng mL−1. The lower limit of quantification was 2 ng mL−1 with 100 μL plasma. The validated method was successfully applied to a pharmacokinetic study after intragastic administration
of XQ-1 mesylate in rats at a dose of 20 mg kg−1. 相似文献
7.
Juan Zhang Xiaohui Chen Peng Wang Lin Huo Zhenduo Shen Xiaorui Guo Weiming Cheng Kaishun Bi 《Chromatographia》2008,67(9-10):695-700
A simple, rapid and sensitive liquid chromatography–mass spectrometry (LC–MS) method was developed for the quantification of salidroside in rat plasma and the study of its pharmacokinetics after oral administration of 15 g kg?1 Rhodiola crenulata extract to Wistar rats. A 200 μL plasma sample was extracted by acetonitrile and performed on Kromasil C18 column (150 mm × 4.6 mm, 5 μm) with the mobile phase of acetonitrile–water (11:89) within a run time of 8 min. The analyte was monitored with electrospray ionization (ESI) by selected ion monitoring (SIM) mode. The target ions were m/z 299.20 for salidroside and m/z 150.00 for internal standard (IS) paracetamol. A good linear relationship was obtained over the range of 100–20,000 ng mL?1 and the lower limit of quantification was 100 ng mL?1. The validated method was successfully applied for the pharmacokinetic study of salidroside in rat. After oral administration of Rhodiola crenulata extract, the main pharmacokinetic parameters T max, T 1/2, C max, AUC 0?t and AUC 0?∞ were 0.56 ± 0.21 h, 7.91 ± 4.42 h, 3,386 ± 2,138 ng mL?1, 16,146 ± 6,558 ng h mL?1 and 18,599 ± 6,529 ng h mL?1, respectively. 相似文献
8.
Xiang Chen Ben-Mei Chen Shao-Gang Liu Fu-Liang Denga Ping Zhou 《Chromatographia》2008,68(11-12):941-947
An LC–MS method for the determination of dothiepin in human plasma was developed and validated. Sample preparation involved extraction with n-hexane:2-propanol (95:5). Separation was on an Ultimate XB C18 column (2.1 × 150 mm, 5 μm). A single-quadrupole mass spectrometer with an electrospray interface was operated in the selected-ion monitoring mode to detect the [M+H]+ ions at m/z 296 for dothiepin and at m/z 278 for the internal standard (amitriptylene). The method demonstrated good linearity from 0.78 ng mL?1 (the LOQ) to100 ng mL?1. The mean extraction recovery was 82.4% for dothiepin and and 84.2% for the internal standard. The intra-day and inter-day precision ranged from 8.5 to 11.4% and 9.7 to 12.1% (RSD), respectively. The method was successfully applied to bioequivalence studies of dothiepin hydrochloride tablets to obtain the pharmacokinetic parameters. 相似文献
9.
Zhi-Rong Tan Dong-Sheng Ou-Yang Gan Zhou Yao Chen Wei-Yong Li Lan Fan Hong-Hao Zhou 《Chromatographia》2009,70(3-4):415-421
Batifiban is a new platelet GPIIb/IIIa receptor antagonist. In this work, an analytical method based on liquid chromatography and electrospray ionization tandem mass spectrometry has been firstly developed and validated for the quantitative measurement of batifiban in human plasma to support the investigation of this compound. Separation of analyte and the internal standard eptifibatide was performed on a Thermo HyPURITY C18 column (150 × 2.1 mm, 5 μm) with a mobile phase consisting of formic acid 0.1% (v/v)–acetonitrile (40:60, v/v) at a flow rate of 0.25 mL min?1. The Waters QuattroMicro API triple quadrupole mass spectrometer was operated in multiple reaction monitoring mode via positive electrospray ionization interface using the transition m/z 819.2 → m/z (623.9 + 159.4) for batifiban and m/z 833.4 → m/z (645.7 + 159.3) for IS. The method was linear over the concentration range of 2.45–5,000 μg L?1. The intra- and inter- day precisions were less than 15% in terms of relative standard deviation, and the accuracy was within 8.5% in terms of relative error (RE). The lower limit of quantification (LLOQ) was identifiable and reproducible at 2.45 μg L?1 with acceptable precision and accuracy. The validated method offered sensitivity and wide linear concentration range. This method was successfully applied for the evaluation of pharmacokinetics of batifiban afer single oral doses of 55, 110 and 220 μg kg?1 batifiban to 36 Chinese healthy volunteers. 相似文献
10.
Qiongfeng Liao Zhiyong Xie Biyan Pan Chenchen Zhu Meicun Yao Xinjun Xu Jinzhi Wan 《Chromatographia》2008,67(9-10):687-694
A liquid chromatography–tandem mass spectrometry (LC–MS–MS) method was developed for the simultaneous determination of paracetamol, pseudoephedrine and chlorpheniramine in human plasma. Diphenhydramine was used as the internal standard. Analytes were extracted from alkalized human plasma by liquid–liquid extraction (LLE) using ethyl acetate. After electrospray ionization positive ion fragments were detected in the selected reaction monitoring (SRM) mode with a triple quadrupole tandem mass spectrometer. The method was linear in the concentration range of 20.0–10000.0 ng mL?1 for paracetamol, 1.0–500.0 ng mL?1 for pseudoephedrine and 0.1–50.0 ng mL?1 for chlorpheniramine. The intra- and inter-day precisions were below 14.5% and the bias was between ?7.3 and +2.8% for all analytes. The validated LC–MS–MS method was applied to a pharmacokinetic study in which each healthy Chinese volunteer received a tablet containing 300 mg benorylate, 30 mg pseudoephedrine hydrochloride and 2 mg chlorpheniramine maleate. This is the first assay method described for the simultaneous determination of paracetamol, pseudoephedrine and chlorpheniramine in human plasma samples. 相似文献
11.
12.
Shi-Jia Liu Zi-Xiu Liu Wen-Zheng Ju Zhi-Yuan Chen Ning-Ning Xiong Heng-Shan Tan 《Chromatographia》2010,72(9-10):821-825
A rapid and sensitive LC–MS–MS method was developed and validated for the determination of asiaticoside in rat plasma. Asiaticoside was extracted by protein precipitation with acetonitrile, and separated on a C18 column. The total analytical time was relatively short (4 min), and the limit of quantification was 38 ng mL?1 using 100 μL of rat plasma. Asiaticoside and the internal standard (felodipine) were monitored in the multi-reaction-monitoring mode as follows: m/z 957.4 → 469.3 and m/z 382.2 → 145.1, respectively. Calibration was linear over a concentration range from 38 to 7,600 ng mL?1, and the correlation coefficient was greater than 0.998. The recoveries of asiaticoside from plasma were better than 85%, and RSDs of inter-day and intra-day assays were below 10.1%. The method is sensitive and specific, and suitable for pharmacokinetic studies of asiaticoside in rats. 相似文献
13.
Zhongyang Liu Guangzhi Gu Huimin Xia Qiang Liu Zhiqing Pang Xinguo Jiang Jun Chen 《Chromatographia》2011,74(3-4):227-234
A reversed-phase liquid chromatography coupled to tandem mass spectrometry (LC?CMS?CMS) method was developed and validated for the determination of fulvestrant in rat plasma. Sample preparation involved a liquid-liquid extraction using 1.0 mL of n-hexane?Cisopropanol (90:10, v/v) to extract the analyte from 0.1 mL of rat plasma. The analytes were separated on a phenyl-based column using the mobile phase consisting of methanol/water containing 5 mM ammonium acetate at the flow rate of 0.3 mL min?1. The analytes were monitored by tandem mass spectrometry under electrospray negative ionization mode. Linear calibration curves were generated over the fulvestrant concentration ranges of 0.05?C10.0 ng mL?1 in rat plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical methods (<15%). This developed and validated assay method was successfully employed to characterize the plasma concentration-time profile of fulvestrant after its intramuscular administration in rats at a dose of 10 mg kg?1. 相似文献
14.
Liberato Brum Junior Manoela Guerra Leal Fl��via de Toni Uchoa Moacir Kaiser S��lvia Stani?uaski Guterres Teresa Dalla Costa 《Chromatographia》2011,73(11-12):1081-1088
A fast, sensitive, and specific LC?CMS?CMS method for determination of quinine (QN) and doxycycline (DOX) in rat plasma has been developed and validated. QN, DOX, and cimetidine (internal standard, IS) were extracted from the plasma by protein precipitation. The compounds were separated on a C18 column with methanol?C0.1% aqueous formic acid 70:30 (v/v) as mobile phase at a flow rate of 0.5 mL min?1 (split 1:3). Detection was by positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode, monitoring the transitions 325.0 ?? 307.0, 445.0 ?? 428.1, and 252.8 ?? 159.0, for QN, DOX, and IS, respectively. The analysis was carried out in 2.0 min and the method was linear in the plasma concentration range 5?C5,000 ng mL?1. The mean extraction recoveries for QN, DOX, and IS from plasma were 89.4, 90.5, and 86.3%, respectively. The method was validated for linearity, precision, accuracy, specificity, and stability; the results obtained were within the acceptable range. The proposed method was successfully applied to the determination of QN and DOX in rat plasma samples to support pharmacokinetic studies. 相似文献
15.
This paper reports a sensitive, specific, and stable chromatographic procedure with selective detection (electrospray mass
spectrometry in selected-ion-monitoring mode) combined with simple and efficient sample preparation for determination of icariin
in rat plasma after administration of Herba Epimedii. Separation of the analyte, possible endogenous compounds, and constituents
of Herba Epimedii were accomplished on a 250 mm × 2.0 mm i.d. C18 column by use of a rapid gradient. Ionization of icariin and clarithromycin (internal standard) was achieved by use of the
electrospray interface in positive-ion mode. Conditions such as ionization mode, type of organic modifier, eluent additives,
and Q-array potential were optimized to achieve good sensitivity and specificity of icariin detection. Response was a linear
function of concentration over the range 0.2–20 ng mL−1. The method is accurate and precise; within-batch and between-batch precision (CV) are <15%, and accuracy (RE) is better
than ±15%. The method can be used for analysis of icariin in plasma after administration of Herba Epimedii or of traditional
Chinese medicinal preparations containing Herba Epimedii. 相似文献
16.
Zhi-Rong Tan Yao Chen Gan Zhou Shan Cao Xiang-Dong Peng Yi-Cheng Wang Xiu-Juan Peng Wei Zhang Hong-Hao Zhou 《Chromatographia》2010,72(11-12):1107-1113
A sensitive and specific liquid chromatography–electrospray ionization-tandem mass spectrometry method has been developed and validated for the identification and quantification of ursolic acid in human plasma using glycyrrhetic acid as an internal standard. The method involves extraction with methyl tert-butyl ether. The analyte was separated on a C18 column and analyzed in multiple reaction monitoring mode with a negative electrospray ionization interface using the [M–H]? ions, m/z 455.4 for ursolic acid and m/z 469.5 → m/z 425.5 for glycyrrhetic acid. The method was validated over the concentration range of 0.86–110.0 μg L?1. The intra- and inter-day precisions were less than 13.53% relative standard deviation (RSD) and the accuracy was within ?4.76% in terms of relative error (RE). The lower limit of quantification was 0.86 μg L?1 with acceptable precision and accuracy. There were almost no matrix effects. Recovery of ursolic acid from spiked drug-free plasma was higher than 68%. The method was used to study the pharmacokinetic profile of ursolic acid in human plasma after oral administration of Jieyu capsules. 相似文献
17.
A rapid and sensitive method was developed and validated for the determination of MCYST (microcystin)-RR, -LR, and [Dha7] MCYST-LR in rat plasma by liquid chromatography-tandem mass spectrometry. The analytes were extracted from rat plasma by protein precipitation, followed by solid-phase extraction. Liquid chromatography with electrospray ionization mass spectrometry, operating in selected reaction monitoring (SRM) mode, was used to quantify MCYST-RR, -LR, and [Dha7] MCYST-LR in rat plasma. The recoveries for each analyte in rat plasma ranged from 70.8 to 88.7%. The calibration curve was linear within the range from 0.005 to 1.25 μg mL?1. The limit of detection were 1.4, 1.0, 0.6 ng mL?1 for MCYST-RR, -LR, and [Dha7] MCYST-LR. The overall precision was determined on three different days. The values for within- and between-day precision in rat plasma were within 15%. This method was applied to the identification and quantification of microcystins in rat plasma with acute exposure of microcystins via intravenous injection. 相似文献
18.
A simple, rapid and sensitive reverse phase liquid chromatography-diode array detector method has been developed and validated for the determination of isoliquiritigenin in rat plasma using acetanilide as an internal standard. The plasma was deproteinized with acetonitrile and separated from the aqueous layer by adding sodium chloride. The mobile phase was acetonitrile, 0.05 M potassium dihydrogen phosphate and triethylamine (50:50:0.5, v/v/v) (pH 2.00). Detection wavelength was set at 242 nm during 0–5 min and 362 nm during 5–9 min. The limit of quantification was 0.019 μg mL?1. The mean accuracy was 96.851–98.140%. Extract recoveries at concentration of 0.038, 0.625, 1.250, 5.000 and 20.000 μg mL?1 were 82.740, 80.814, 80.920, 80.978 and 81.103%, respectively. The validated method was successfully applied to the pharmacokinetic study of ISL in rat plasma after intravenous administration. 相似文献
19.
Xia Li Haijing Liu Ji Li Xinfeng Zhao Shixiang Wang Xiaohui Zheng 《Chromatographia》2009,70(7-8):1113-1119
A valid and sensitive LC-MS–MS method is adopted for pharmacokinetics study of berberine and palmatine in rabbit plasma. After mixing with internal standard tetrahydroberberine, plasma samples were pretreated with 1.5 mL acetonitrile. Chromatographic separation was on a C18 column using a mixture of water (containing 10 mmol L?1 ammonium acetate, pH 3.5) and acetonitrile (50∶50, v/v) as mobile phase. The detection was performed by selected ion monitoring mode via electrospray ionization source operating in the positive ionization mode. The method was linear over the concentration range of 2.0–200.0 ng mL?1 for berberine and 1.0–100.0 ng mL?1 for palmatine. The lowest limits of quantitation (LLOQ) were 2.0 ng mL?1 for berberine and 1.0 ng mL?1 for palmatine. The intra- and inter-day precision values were less than 14.3% and the deviations were within ±11.0%. The fully validated LC-MS–MS method has been successfully applied to a pharmacokinetic study of berberine, palmatine in rabbit plasma after oral administration of Coptidis and coptidis–gardeniae couple extract. The results indicated that the plasma profiles of the two compounds in rabbit confirmed to one-compartment open model and the combinational utilization with Gardeniae could increase the bioavailability of berberine and palmatine, the two major active components of Coptidis. 相似文献
20.
A rapid and sensitive method for determination of methyl nonyl ketone in rat plasma was developed based on GC–MS. The analyte and internal standard, propyl p-hydroxybenaoate, were extracted from plasma with methyl tert-butyl ether and then separated by an HP-5MS capillary analytical column (30 m × 0.25 mm, 0.25 µm) and determined by a quadrupole mass spectrometer detector operated under EI ionization and selected ion monitoring mode. Excellent linearity was found to be from 5.0 to 1,000 ng mL?1 with a lower limit of quantitation of 5.0 ng mL?1. The accuracy was between 96.0 and 106.3%, and the intra- and inter-day precision and accuracy values were found to be within the assay variability criteria limits according to the FDA guidelines. The developed method was successfully applied to the pharmacokinetic study of methyl nonyl ketone, a typical component in the traditional Chinese medicine Houttuynia cordata injection, in rats after a single oral dose of 100 mg kg?1 and peritoneal injection dose of 5 mg kg?1, respectively. 相似文献