首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To perform fast and sensitive trace metal analysis in aqueous solutions by laser-induced breakdown spectroscopy (LIBS) based on only one single-pulse laser system, a wood slice has been used as a liquid absorber to transform liquid sample analysis to solid sample analysis using LIBS. High detection sensitivity and good reproducibility can be achieved with this approach. Calibration curves for five metal elements, Cr, Mn, Cu, Cd, and Pb under trace concentrations, have been obtained, and the limits of their detection were determined to be in the range of 0.029–0.59 mg L− 1, 2–3 orders better than those obtained by directly analyzing liquid samples where the laser was focused on a liquid surface. The wood slice was very easy to handle and thus, the whole analysis process took only 4–5 min for each sample. This approach provides a more practical approach for fast and sensitive metal element analysis in aqueous solutions using LIBS, which is especially useful for monitoring toxic heavy metals in water.  相似文献   

2.
In this paper Laser Induced Breakdown Spectroscopy has been applied for determining the elemental composition of a set of ancient bronze artworks coming from archaeological site of Minervino Murge — Southern of Italy (dated around VII b.C.). Before carrying on the analysis of the archaeological samples, the characterization of the analytical technique has been accomplished by investigating the trueness of the typical assumptions adopted in LIBS, such as Local Thermodynamic Equilibrium, congruent ablation and plasma homogeneity. With this purpose, two different laser pulse durations, 7 ns and 350 fs, have been used. We have focused our attention on LIBS analysis of bronze standards by considering and discussing the bases of both methodology and analytical approach to be followed for the analysis of ancient copper-based-alloy samples. Unexpectedly, regardless from the laser pulse duration, the LIBS technique has shown, by considering an adequate approach on the emitting plasma features, that its peculiarities are anyway preserved so that a fast analysis of ancient copper-based-alloys can be achieved. After verifying the suitability of the methodology, it has been possible to fulfill the typical assumptions considered for the LIBS calibration curves method and use it for ancient bronze artworks analysis.  相似文献   

3.
The problem of finding new methods for the analysis of precious alloys has stimulated, in recent years, a number of different proposals for improving the analytical procedures introducing more robust calibration (or calibration-free) methods. In the paper “Accurate quantitative analysis of gold alloys using multi-pulse laser-induced breakdown spectroscopy and a correlation-based calibration method” by G. Galbács, N.Jedinski, G.Cseh, Z. Galbács and L. Túri [Spectrochimica Acta Part B, Volume 63, Issue 5, 591–597 (May 2008)] the authors proposed the use of multiple-pulse LIBS and a correlation-based method for building calibration curves for quantitative analysis of gold alloys. The method is proposed for gold alloys prepared using a fixed proportion of the alloying element. The general case where the relative concentration of the elements of the matrix is not a priori known is not discussed in the paper. In this communication, we will demonstrate that the method proposed is extremely fragile against matrix effects, and therefore cannot be usefully applied for the purpose of actual analytical measurements on gold alloys without a previous knowledge of the matrix composition.  相似文献   

4.
The laser-induced breakdown spectroscopy (LIBS) is an applied physical technique that has shown in recent years its great potential for rapid qualitative analysis of materials. Thanks to the possibility to implement a portable instrument that perform LIBS analysis, this technique is revealed to be particularly useful for in situ analysis in the field of cultural heritages. The purpose of this work is to evaluate the potentiality of LIBS technique in the field of cultural heritages, with respect to the chemical characterization of complex matrix as calcareous and refractory materials for further quantitative analyses on cultural heritages. X-Ray Fluorescence (XRF) analyses were used as reference. Calibration curves of certified materials used as standards were obtained by XRF analyses. The LIBS measurements were performed with a new mobile instrument called Modì (Mobile Double pulse Instrument for LIBS Analysis). The XRF analyses were performed with a portable instrument ArtTAX. LIBS and XRF measurement were performed on both reference materials and samples (bricks and mortars) sampled in the ancient Greek–Roman Theatre of Taormina. Although LIBS measurements performed on reference materials have shown non linear response to concentrations, and so we were not able to obtain quantitative results, an integrated study of XRF and LIBS signals permitted us to distinguish among chemical features and degradation state of measured building materials.  相似文献   

5.
Double-pulse laser-induced plasma spectroscopy (DP-LIPS) is applied to submerged targets to investigate its feasibility for elemental analysis. The role of experimental parameters, such as inter-pulse delay and detection time, has been discussed in terms of the dynamics of the laser-induced bubble produced by the first pulse and its confinement effect on the plasma produced by the second laser pulse. The analytical performance of this technique applied to targets in a water environment are discussed. The elemental analysis of submerged copper alloys by DP-LIPS has been compared with conventional (single-pulse) LIBS in air. Theoretical investigation of the plasma dynamics in water bubbles and open air has been performed.  相似文献   

6.
The influence of laser pulse duration on laser-induced breakdown spectroscopy (LIBS) calibration curves is investigated in the present work. Two Nd:YAG lasers providing pulses of 35 ps and 5 ns, respectively, both operating at 1064 nm, have been used to create plasmas on aluminium, manganese, iron, and silicon targets and on prepared stoichiometric samples of these metals in a matrix. The time-resolved, space-averaged plasma temperatures have been deduced using Boltzmann plots, while the electron number density has been determined from the broadening of spectral lines. The effect of laser pulse duration on the plasma characteristics is discussed, and comparisons are made with previously reported data measured under similar experimental conditions. The optimum experimental conditions (i.e., time delay, gate width, laser energy) have been determined for reliable use of LIBS for quantitative analysis for both pulse durations. For each of the metals of interest, calibration curves have been constructed for concentrations ranging up to 2%.  相似文献   

7.
The variations of thermal conductivities of solid phases versus temperature for pure Sn, pure Al and Sn–0.5 wt.% Al, Sn–2.2 wt.% Al, Sn–25 wt.% Al, Sn–50 wt.% Al, Sn–75 wt.% Al binary alloys were measured with a radial heat flow apparatus. From thermal conductivity variations versus temperature, the thermal conductivities of the solid phases at their melting temperature and temperature coefficients for same materials were also found to be 60.60 ± 0.06, 208.80 ± 0.22, 69.70 ± 0.07, 80.30 ± 0.08, 112.30 ± 0.12, 142.00 ± 0.15, 188.50 ± 0.20 W/K m and 0.00098, 0.00062, 0.00127, 0.00114, 0.00112, 0.00150, 0.00116 K−1, respectively. The thermal conductivity ratios of liquid phase to solid phase for the pure Sn, pure Al and eutectic Sn–0.5 wt.% Al alloy at their melting temperature are found to be 1.11, 1.13, 1.06 with a Bridgman type directional solidification apparatus, respectively. Thus the thermal conductivities of liquid phases for pure Sn, pure Al and eutectic Sn–0.5 wt.% Al binary alloy at their melting temperature were evaluated to be 67.26, 235.94 and 73.88 W/K m, respectively by using the values of solid phase thermal conductivities and the thermal conductivity ratios of liquid phase to solid phase.  相似文献   

8.
Statistical uncertainty in the quantitative analysis of solid samples in motion by laser-induced breakdown spectroscopy (LIBS) has been assessed. For this purpose, a LIBS demonstrator was designed and constructed in our laboratory. The LIBS system consisted of a laboratory-scale conveyor belt, a compact optical module and a Nd:YAG laser operating at 532 nm. The speed of the conveyor belt was variable and could be adjusted up to a maximum speed of 2 m s− 1. Statistical uncertainty in the analytical measurements was estimated in terms of precision (reproducibility and repeatability) and accuracy. The results obtained by LIBS on shredded scrap samples under real conditions have demonstrated that the analytical precision and accuracy of LIBS is dependent on the sample geometry, position on the conveyor belt and surface cleanliness. Flat, relatively clean scrap samples exhibited acceptable reproducibility and repeatability; by contrast, samples with an irregular shape or a dirty surface exhibited a poor relative standard deviation.  相似文献   

9.
The analytical performance of femtosecond laser-induced breakdown spectroscopy (LIBS) for elemental microanalysis of aluminium alloys and for mapping precipitate distribution on the sample surface has been studied in detail. A Ti–sapphire laser system producing pulses of 130 fs at 800 nm was used to generate the laser-induced plasma. Multi-element microanalysis of commercially available aluminium alloys was performed in air at atmospheric pressure. Crater characteristics such as diameter and crater morphology were characterized by optical and scanning-electron microscopy. Scaling of plasma emission and limit of detection as a function of laser pulse energy was also investigated. Current experimental results are presented and are compared with previous nanosecond microLIBS measurements.  相似文献   

10.
The laser-induced breakdown spectroscopy (LIBS) is an applied physical technique that has shown in recent years its great potential for rapid qualitative analysis of materials. Thanks to the possibility to implement a portable instrument that perform LIBS analysis, this technique is revealed to be particularly useful for in situ analysis in the field of cultural heritages. The purpose of this work is to evaluate the potentiality of LIBS technique in the field of cultural heritages, with respect to the chemical characterization of complex matrix as calcareous and refractory materials for further quantitative analyses on cultural heritages. X-Ray Fluorescence (XRF) analyses were used as reference. Calibration curves of certified materials used as standards were obtained by XRF analyses. The LIBS measurements were performed with a new mobile instrument called Modì (Mobile Double pulse Instrument for LIBS Analysis). The XRF analyses were performed with a portable instrument ArtTAX. LIBS and XRF measurement were performed on both reference materials and samples (bricks and mortars) sampled in the ancient Greek–Roman Theatre of Taormina. Although LIBS measurements performed on reference materials have shown non linear response to concentrations, and so we were not able to obtain quantitative results, an integrated study of XRF and LIBS signals permitted us to distinguish among chemical features and degradation state of measured building materials.  相似文献   

11.
In this work, the Stark effect is shown to be mainly responsible for wrong elemental allocation by automated laser-induced breakdown spectroscopy (LIBS) software solutions. Due to broadening and shift of an elemental emission line affected by the Stark effect, its measured spectral position might interfere with the line position of several other elements. The micro-plasma is generated by focusing a frequency-doubled 200 mJ pulsed Nd/YAG laser on an aluminum target and furthermore on a brass sample in air at atmospheric pressure. After laser pulse excitation, we have measured the temporal evolution of the Al(II) ion line at 281.6 nm (4s 1 S-3p 1 P) during the decay of the laser-induced plasma. Depending on laser pulse power, the center of the measured line is red-shifted by 130 pm (490 GHz) with respect to the exact line position. In this case, the well-known spectral line positions of two moderate and strong lines of other elements coincide with the actual shifted position of the Al(II) line. Consequently, a time-resolving software analysis can lead to an elemental misinterpretation. To avoid a wrong interpretation of LIBS spectra in automated analysis software for a given LIBS system, we recommend using larger gate delays incorporating Stark broadening parameters and using a range of tolerance, which is non-symmetric around the measured line center. These suggestions may help to improve time-resolving LIBS software promising a smaller probability of wrong elemental identification and making LIBS more attractive for industrial applications.  相似文献   

12.
Laser Induced Breakdown Spectroscopy (LIBS) is an advanced analytical technique for elemental determination based on direct measurement of optical emission of excited species on a laser induced plasma. In the realm of elemental analysis, LIBS has great potential to accomplish direct analysis independently of physical sample state (solid, liquid or gas). Presently, LIBS has been easily employed for qualitative analysis, nevertheless, in order to perform quantitative analysis, some effort is still required since calibration represents a difficult issue. Artificial neural network (ANN) is a machine learning paradigm inspired on biological nervous systems. Recently, ANNs have been used in many applications and its classification and prediction capabilities are especially useful for spectral analysis. In this paper an ANN was used as calibration strategy for LIBS, aiming Cu determination in soil samples. Spectra of 59 samples from a heterogenic set of reference soil samples and their respective Cu concentration were used for calibration and validation. Simple linear regression (SLR) and wrapper approach were the two strategies employed to select a set of wavelengths for ANN learning. Cross validation was applied, following ANN training, for verification of prediction accuracy. The ANN showed good efficiency for Cu predictions although the features of portable instrumentation employed. The proposed method presented a limit of detection (LOD) of 2.3 mg dm− 3 of Cu and a mean squared error (MSE) of 0.5 for the predictions.  相似文献   

13.
Gondal MA  Hussain T  Yamani ZH  Baig MA 《Talanta》2006,69(5):1072-1078
Laser induced breakdown spectroscopy (LIBS) was applied for the elemental analysis of Arabian crude oil residue samples. The spectra due to trace elements such as Ca, Fe, Mg, Cu, Zn, Na, Ni, K and Mo were recorded using this technique. The dependence of time delay and laser beam energy on the elemental spectra was also investigated. Prior to quantitative analysis, the LIBS system was calibrated using standard samples containing these trace elements. The results achieved through this method were compared with conventional technique like inductively coupled plasma.  相似文献   

14.
The influence of He atmosphere and gate width in laser-induced breakdown spectroscopy (LIBS) determination of fluorine concentration was investigated in detail. The measurements were realized on two double pulse LIBS devices featuring different parameters. Calibration curves, describing the relationship between the fluorine concentration and the corresponding intensity of the LIBS signal, were constructed for both LIBS devices, with and without He flow, respectively. Detection limits achieved were in the range 1.18-0.47 wt.%. The best LOD value was obtained in He atmosphere. The LIBS measurement of fluorine content is influenced by different gate widths and the atmosphere in the working chamber. The proposed method was successfully applied to the determination of fluorine concentration in glass ionomer cements.  相似文献   

15.
Multi-component oxide ceramics and epitaxial oxide thin films are analyzed by laser-induced breakdown spectroscopy (LIBS). Furthermore, pulsed-laser deposition (PLD) of thin films is investigated by long-term monitoring of the optical plasma emission. Both nano-composite high-temperature superconductors (HTS) consisting of YBa2Cu3O7 − δ bulk and Y2Ba4MCuOx (M-2411, M = Ag, Nb) nano-particles, and semiconducting ZnO doped with Aluminum and Lithium are ablated by nano-second laser pulses. The plasma emission is recorded using grating spectrometers with intensified gated detectors. The LIBS signals of nano-particles correlate with the nominal content of the M-2411 phase (0–15 mol%) and reveal a strong signal of Ytterbium impurity (3–35 ppm). In situ monitoring of the PLD process shows element signals that are stable for more than 10,000 laser pulses for both HTS and ZnO ceramics. The relative concentration of elements in thin films and ceramics as determined by LIBS is almost the same.  相似文献   

16.
Rhatany roots (RRs) have been used in indigenous systems of medicines to treat many common illnesses due to the presence of highly active astringent and antiviral biochemical constituents that possess strong therapeutic and pharmacological properties. Due to its widespread use, the accurate knowledge on the elemental composition of this medicinal plant can set a pharmacological research platform to investigate the effect of certain elements, and their ions in mediating the human metabolism and therapy. In this work calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is used to detect the elements present in RRs sample, by analyzing the characteristic emission wavelengths and their respective intensities in the laser induced plasma, without the need for using any calibration standards or methods. Many nutritional elements, which are of human health significance and instrumental in mediating the established biological activities of RRs, were identified in a relative abundance. In addition to this, our analysis identified the trace level of a few toxic elements, whose overdose due to reckless intake wreaks havoc to human health and wellbeing. The reliability of qualitative and quantitative detection of the elements in RR by LIBS were validated by the standard inductively coupled plasma optical emission spectroscopy (ICP OES), the results of which are in good agreement with LIBS data with better relative accuracy. Also, in order to discriminate, and single out any two elements with the overlapping emission wavelength in LIBS, X-ray photoelectron spectroscopy was also carried out, which in its own right is in good agreement with the elemental analysis of LIBS in general.  相似文献   

17.
Laser-ablation based analytical techniques represent a simple way for fast chemical analysis of different materials. In this work, an exploratory study of multi-element (Ca, Al, Fe, Mn) mappings of a granite sample surface was performed by laser-induced breakdown spectroscopy (LIBS) and subsequently by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) analysis. The operating parameters (e.g. pulse energy, ablation-crater size) were optimized for both techniques in order to achieve the appropriate conditions for two-dimensional high-resolution compositional mappings of mineral microstructures in large sample areas. The sample was scanned with 100 × 100 individual sample points to map an area of 20 × 20 mm2. The normalized signals were used for construct of contour plots which were colored according local distribution of the selected elements. The results of two laser-based methods were compared and found to be similar.  相似文献   

18.
Laser Induced Breakdown Spectroscopy (LIBS) is presented as a tool for the elemental analysis of glass in forensic applications. Two harmonics of the Nd:YAG laser at 266 nm and 532 nm were used as the irradiation source for the analysis of several glass standards and soda–lime glass samples of interest to forensic scientists. Both lasers were kept at a constant energy of 20 mJ and focused using a 150 mm focal length lens. A series of experiments were also conducted to determine the importance of wavelength on lens-to-sample distance (LTSD) at each wavelength. It was determined that the optimal LTSD was found at ~ 1–2 mm focused into the surface for both wavelengths yet the crater depth resulting from the irradiation at 266 nm was significantly deeper (112 µm) than that from the 532 nm laser (41 µm). In addition, the analytical performance of LIBS on 5 NIST glasses and 6 automobile glasses at both wavelengths is reported. Good correlation for the quantitative analysis results for the trace and minor elements Sr, Ba and Al are reported along with the calibration curves, in most cases R2 > 0.95, using absolute intensities at various emission lines. Although 266 nm resulted in more mass removal, the 532 nm produced greater emission intensities. A slightly higher plasma density was determined for irradiation by 532 nm using the Stark broadening technique in comparison to the 266 nm irradiation.  相似文献   

19.
The archeological round bronze coins, nominated as Wu Zhou and regarded as the first issued effective money in the Han Dynasty of China, have been systematically investigated to disclose their chemical composition, nature of the patina and corrosion features on the coin surface by optical microscopy (OM), X-ray diffraction (X-RD), and scanning electron microscopy (SEM) equipped with backscattered electron (BSE) detector and energy dispersive spectrometry (EDS) techniques. It is revealed morphologically that there are some rough surface cracks, pits, and multicolor patina on the surface of the coins. We prove that the coins are made from bronze material of Cu–Sn–Pb–Sb alloy with contents of 84.8–85.4 wt.% Cu, 3.3–6.1 wt.% Sn, 4.7–6.4 wt.% Pb and 2.6–2.9 wt.% Sb, and covered by two corrosion layers, 25–35 μm for the upper-layer and 20–25 μm for the sub-layer. High chloride content has been detected at the interface between the sub-layer and body of the coins. The lead-rich and tin-rich areas in the coin samples indicate the poor metal compatibility during minting in some locations of the coins. The main compositions of patina are ascertained to be Cu2(OH)3Cl, Cu3(CO3)2(OH)2, Cu2(OH)2CO3, and Pb3O4, and the proposed corrosion mechanism is discussed.  相似文献   

20.
Actual state of affairs, main advantages and problems of Laser-Induced Breakdown Spectroscopy (LIBS) in analysis of industrial materials and environmental samples are discussed. Methods for LIBS sensitivity enhancement such as double-pulse ablation, a combination of LIBS with laser-induced fluorescence, the use of additional sources of excitation (spark) and confinement of plasma by magnetic field or shock wave are compared with respect to figures-of-merit. A set of LIBS approach to qualitative fast classification of materials, especially based on the correlation between parameters of laser plasma and sample properties, are discussed in details. Progress in environmental analysis of soils, sands etc. with the use of LIBS is demonstrated. Detection limits of the most elements in soils and aluminum alloys obtained until now are critically considered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号