共查询到20条相似文献,搜索用时 15 毫秒
1.
Lilian Cristina Trevizan Dário Santos Jr. Ricardo Elgul Samad Nilson Dias Vieira Jr. Lidiane Cristina Nunes Iolanda Aparecida Rufini Francisco José Krug 《Spectrochimica Acta Part B: Atomic Spectroscopy》2009
Laser induced breakdown spectroscopy (LIBS) has been evaluated for the determination of micronutrients (B, Cu, Fe, Mn and Zn) in pellets of plant materials, using NIST, BCR and GBW biological certified reference materials for analytical calibration. Pellets of approximately 2 mm thick and 15 mm diameter were prepared by transferring 0.5 g of powdered material to a 15 mm die set and applying 8.0 tons cm− 2. An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm (200 mJ per pulse, 10 Hz) and an Echelle spectrometer with ICCD detector. Repeatability precision varied from 4 to 30% from measurements obtained in 10 different positions (8 laser shots per test portion) in the same sample pellet. Limits of detection were appropriate for routine analysis of plant materials and were 2.2 mg kg− 1 B, 3.0 mg kg− 1 Cu, 3.6 mg kg− 1 Fe, 1.8 mg kg− 1 Mn and 1.2 mg kg− 1 Zn. Analysis of different plant samples were carried out by LIBS and results were compared with those obtained by ICP OES after wet acid decomposition. 相似文献
2.
Evaluation of grinding methods for pellets preparation aiming at the analysis of plant materials by laser induced breakdown spectrometry 总被引:1,自引:0,他引:1
It has been demonstrated that laser induced breakdown spectrometry (LIBS) can be used as an alternative method for the determination of macro (P, K, Ca, Mg) and micronutrients (B, Fe, Cu, Mn, Zn) in pellets of plant materials. However, information is required regarding the sample preparation for plant analysis by LIBS. In this work, methods involving cryogenic grinding and planetary ball milling were evaluated for leaves comminution before pellets preparation. The particle sizes were associated to chemical sample properties such as fiber and cellulose contents, as well as to pellets porosity and density. The pellets were ablated at 30 different sites by applying 25 laser pulses per site (Nd:YAG@1064 nm, 5 ns, 10 Hz, 25 J cm−2). The plasma emission collected by lenses was directed through an optical fiber towards a high resolution echelle spectrometer equipped with an ICCD. Delay time and integration time gate were fixed at 2.0 and 4.5 μs, respectively. Experiments carried out with pellets of sugarcane, orange tree and soy leaves showed a significant effect of the plant species for choosing the most appropriate grinding conditions. By using ball milling with agate materials, 20 min grinding for orange tree and soy, and 60 min for sugarcane leaves led to particle size distributions generally lower than 75 μm. Cryogenic grinding yielded similar particle size distributions after 10 min for orange tree, 20 min for soy and 30 min for sugarcane leaves. There was up to 50% emission signal enhancement on LIBS measurements for most elements by improving particle size distribution and consequently the pellet porosity. 相似文献
3.
Lidiane Cristina Nunes Gilmare Antônia da Silva Lilian Cristina Trevizan Dario Santos Júnior Ronei Jesus Poppi Francisco José Krug 《Spectrochimica Acta Part B: Atomic Spectroscopy》2009
A simultaneous optimization strategy based on a neuro-genetic approach is proposed for selection of laser induced breakdown spectroscopy operational conditions for the simultaneous determination of macro-nutrients (Ca, Mg and P), micro-nutrients (B, Cu, Fe, Mn and Zn), Al and Si in plant samples. A laser induced breakdown spectroscopy system equipped with a 10 Hz Q-switched Nd:YAG laser (12 ns, 532 nm, 140 mJ) and an Echelle spectrometer with intensified coupled-charge device was used. Integration time gate, delay time, amplification gain and number of pulses were optimized. Pellets of spinach leaves (NIST 1570a) were employed as laboratory samples. In order to find a model that could correlate laser induced breakdown spectroscopy operational conditions with compromised high peak areas of all elements simultaneously, a Bayesian Regularized Artificial Neural Network approach was employed. Subsequently, a genetic algorithm was applied to find optimal conditions for the neural network model, in an approach called neuro-genetic. A single laser induced breakdown spectroscopy working condition that maximizes peak areas of all elements simultaneously, was obtained with the following optimized parameters: 9.0 µs integration time gate, 1.1 µs delay time, 225 (a.u.) amplification gain and 30 accumulated laser pulses. The proposed approach is a useful and a suitable tool for the optimization process of such a complex analytical problem. 相似文献
4.
Evaluation of laser induced breakdown spectroscopy for cadmium determination in soils 总被引:2,自引:0,他引:2
Dario Santos Jr. Lidiane C. Nunes Lilian C. Trevizan Quienly Godoi Flavio O. Leme Jez Willian B. Braga Francisco Jos Krug 《Spectrochimica Acta Part B: Atomic Spectroscopy》2009,64(10):1073
Cadmium is known to be a toxic agent that accumulates in the living organisms and present high toxicity potential over lifetime. Efforts towards the development of methods for microanalysis of environmental samples, including the determination of this element by graphite furnace atomic absorption spectrometry (GFAAS), inductively coupled plasma optical emission spectrometry (ICP OES), and inductively coupled plasma-mass spectrometry (ICP-MS) techniques, have been increasing. Laser induced breakdown spectroscopy (LIBS) is an emerging technique dedicated to microanalysis and there is a lack of information dealing with the determination of cadmium. The aim of this work is to demonstrate the feasibility of LIBS for cadmium detection in soils. The experimental setup was designed using a laser Q-switched (Nd:YAG, 10 Hz, λ = 1064 nm) and the emission signals were collimated by lenses into an optical fiber coupled to a high-resolution intensified charge-coupled device (ICCD)-echelle spectrometer. Samples were cryogenically ground and thereafter pelletized before LIBS analysis. Best results were achieved by exploring a test portion (i.e. sampling spots) with larger surface area, which contributes to diminish the uncertainty due to element specific microheterogeneity. Calibration curves for cadmium determination were achieved using certified reference materials. The metrological figures of merit indicate that LIBS can be recommended for screening of cadmium contamination in soils. 相似文献
5.
Jez Willian Batista Braga Lilian Cristina Trevizan Lidiane Cristina Nunes Iolanda Aparecida Rufini Dário Santos Jr. Francisco José Krug 《Spectrochimica Acta Part B: Atomic Spectroscopy》2010
The application of laser induced breakdown spectrometry (LIBS) aiming the direct analysis of plant materials is a great challenge that still needs efforts for its development and validation. In this way, a series of experimental approaches has been carried out in order to show that LIBS can be used as an alternative method to wet acid digestions based methods for analysis of agricultural and environmental samples. The large amount of information provided by LIBS spectra for these complex samples increases the difficulties for selecting the most appropriated wavelengths for each analyte. Some applications have suggested that improvements in both accuracy and precision can be achieved by the application of multivariate calibration in LIBS data when compared to the univariate regression developed with line emission intensities. In the present work, the performance of univariate and multivariate calibration, based on partial least squares regression (PLSR), was compared for analysis of pellets of plant materials made from an appropriate mixture of cryogenically ground samples with cellulose as the binding agent. The development of a specific PLSR model for each analyte and the selection of spectral regions containing only lines of the analyte of interest were the best conditions for the analysis. In this particular application, these models showed a similar performance, but PLSR seemed to be more robust due to a lower occurrence of outliers in comparison to the univariate method. Data suggests that efforts dealing with sample presentation and fitness of standards for LIBS analysis must be done in order to fulfill the boundary conditions for matrix independent development and validation. 相似文献
6.
O. Ayed Nassef Hani E. Elsayed-Ali 《Spectrochimica Acta Part B: Atomic Spectroscopy》2005,60(12):1564-1572
Laser induced breakdown spectroscopy is combined with a spark discharge to operate in a laser triggered spark discharge mode. This spark discharge laser induced breakdown spectroscopy (SD-LIBS) is evaluated for Al and Cu targets in air under atmospheric pressure. Significant enhancement in the measured line intensities and the signal-to-background ratios, which depend on the spark discharge voltage and the laser fluence, is observed in spark discharge laser induced breakdown spectroscopy when compared to laser induced breakdown spectroscopy alone for similar laser conditions. The measured line intensities increase with the applied voltage for both targets, and the ratio of the measured line intensity using spark discharge laser induced breakdown spectroscopy to that using laser induced breakdown spectroscopy is found to increase as the laser fluence is decreased. For Al II 358.56, such intensity enhancement ratio increases from 50 to 400 as the laser fluence is decreased from 48 to 4 J/cm2 at an applied voltage of 3.5 kV. Thus, spark discharge laser induced breakdown spectroscopy allows for using laser pulses with relatively low energy to ablate the studied material, causing less ablation, and hence less damage to its surface. Moreover, applying spark discharge laser induced breakdown spectroscopy gives up to 6-fold enhancement in the S / B ratio, compared to those obtained with laser induced breakdown spectroscopy for the investigated spectral emission lines. 相似文献
7.
M. Galiov J. Kaiser K. Novotný O. Samek L. Reale R. Malina K. Pleníkov M. Lika V. udek V. Kanický V. Otruba A. Poma A. Tucci 《Spectrochimica Acta Part B: Atomic Spectroscopy》2007,62(12):1597-1605
We report on the development and implementation of analytical methodology for investigating elemental accumulation in different layers within plant leaves, with in-situ spatial resolution mapping, exploiting the technique of LIBS. The spectrochemical analysis of lead-doped leaf samples is demonstrated to develop a real time identification procedure in order to complement other analytical techniques not lending themselves for spatial resolution analysis. Our findings suggest that with elevated levels of Pb within the plants transportation and storage of some nutrition elements is changed. 相似文献
8.
L. Caneve A. Diamanti F. Grimaldi G. Palleschi V. Spizzichino F. Valentini 《Spectrochimica Acta Part B: Atomic Spectroscopy》2010
The laser-based techniques have been shown to be a very powerful tool for artworks characterization and are used in the field of cultural heritage for the offered advantages of minimum invasiveness, in situ applicability and high sensitivity. Laser induced breakdown spectroscopy, in particular, has been applied in this field to many different kinds of ancient materials with successful results. In this work, a fragment of a Roman wall painting from the archaeological area of Pompeii has been investigated by LIBS. The sample elemental composition resulting from LIBS measurements suggested the presence of certain pigments. The ratio of the intensities of different lines related to some characteristic elements is proposed as an indicator for pigment recognition. 相似文献
9.
Vassilia Zorba Xianglei Mao Richard E. Russo 《Spectrochimica Acta Part B: Atomic Spectroscopy》2011,66(2):189-192
Femtosecond laser induced breakdown spectroscopy (LIBS) was used to identify the spatial resolution limitations and assess the minimal detectable mass restrictions in laser-ablation based chemical analysis. The atomic emission of sodium (Na) and potassium (K) dopants in transparent dielectric Mica matrices was studied, to find that both these elements could be detected from 450 nm diameter ablation craters, full-width-at-half-maximum (FWHM). Under optimal conditions, mass as low as 220 ag was measured, demonstrating the feasibility of using laser-ablation based chemical analysis to achieve high spatial resolution elemental analysis in real-time and at atmospheric pressure conditions. 相似文献
10.
I.B. Gornushkin U. Panne J.D. Winefordner 《Spectrochimica Acta Part B: Atomic Spectroscopy》2009,64(10):1040
The purpose of this work is to improve the performance of a linear correlation method used for material identification in laser induced breakdown spectroscopy. The improved correlation procedure is proposed based on the selection and use of only essential spectral information and ignoring empty spectral fragments. The method is tested on glass samples of forensic interest. The 100% identification capability of the new method is demonstrated in contrast to the traditional approach where the identification rate falls below 100% for many samples. 相似文献
11.
12.
M. Gaft I. Sapir-Sofer H. Modiano R. Stana 《Spectrochimica Acta Part B: Atomic Spectroscopy》2007,62(12):1496-1503
The purpose of the work was to prove the ability of LIBS to provide on-line analyses for raw ores in field conditions. An industrial LIBS machine was developed and successfully tested for on-belt evaluation of phosphate measuring Mg, Fe, Al, Bone Phosphate Lime (BPL), Insoluble phase and Metal Impurity Ratio (MER) and of coal measuring its ash content. The comparison of LIBS on-line data with control analyses revealed good correlation, which corresponds to the required detection limits and accuracy. With frequent elemental data from a LIBS system, process engineers have the tools to best optimize the process. These processes could be minerals blending and separation to meet customer specifications, monitoring and controlling the efficiency of a minerals process, or a minerals accounting function. 相似文献
13.
The present work studies two different strategies to identify urinary calculus. On one hand, (linear or parametric and rank or non-parametric) correlation methods using a μ-LIBS system are studied. On the other hand, elemental ratios of reference materials are determined by using a higher-energy laser and an Echelle spectrograph with an ICCD camera, although without microscope. A data-treatment method was applied for each system and real samples of kidney stones - previously analyzed by IR spectroscopy - were used for reliable evaluation of two identification strategies. 相似文献
14.
A. De Giacomo M. Dell''Aglio O. De Pascale S. Longo M. Capitelli 《Spectrochimica Acta Part B: Atomic Spectroscopy》2007,62(12):1606-1611
The classification of meteorites when geological analysis is unfeasible is generally made by the spectral line emission ratio of some characteristic elements. Indeed when a meteorite impacts Earth's atmosphere, hot plasma is generated, as a consequence of the braking effect of air, with the consequent ablation of the falling body. Usually, by the plasma emission spectrum, the meteorite composition is determined, assuming the Boltzmann equilibrium. The plasma generated during Laser Induced Breakdown Spectroscopy (LIBS) experiment shows similar characteristics and allows one to verify the mentioned method with higher accuracy. On the other hand the study of Laser Induced Breakdown Spectroscopy on meteorite can be useful for both improving meteorite classification methods and developing on-flight techniques for asteroid investigation.
In this paper certified meteorites belonging to different typologies have been investigated by LIBS: Dofhar 461 (lunar meteorite), Chondrite L6 (stony meteorite), Dofhar 019 (Mars meteorite) and Sikhote Alin (irony meteorite). 相似文献
15.
Erin McIntee Emilie Viglino Caitlin Rinke Stephanie Kumor Liqiang Ni Michael E. Sigman 《Spectrochimica Acta Part B: Atomic Spectroscopy》2010
Laser-induced breakdown spectroscopy (LIBS) has been investigated for the discrimination of automobile paint samples. Paint samples from automobiles of different makes, models, and years were collected and separated into sets based on the color, presence or absence of effect pigments and the number of paint layers. Twelve LIBS spectra were obtained for each paint sample, each an average of a five single shot “drill down” spectra from consecutive laser ablations in the same spot on the sample. Analyses by a nonparametric permutation test and a parametric Wald test were performed to determine the extent of discrimination within each set of paint samples. The discrimination power and Type I error were assessed for each data analysis method. Conversion of the spectral intensity to a log-scale (base 10) resulted in a higher overall discrimination power while observing the same significance level. Working on the log-scale, the nonparametric permutation tests gave an overall 89.83% discrimination power with a size of Type I error being 4.44% at the nominal significance level of 5%. White paint samples, as a group, were the most difficult to differentiate with the power being only 86.56% followed by 95.83% for black paint samples. Parametric analysis of the data set produced lower discrimination (85.17%) with 3.33% Type I errors, which is not recommended for both theoretical and practical considerations. The nonparametric testing method is applicable across many analytical comparisons, with the specific application described here being the pairwise comparison of automotive paint samples. 相似文献
16.
Gabriel Gustinelli Arantes de Carvalho Javier Moros Dário Santos Jr. Francisco José Krug J. Javier Laserna 《Analytica chimica acta》2015
Femtosecond laser-induced breakdown spectroscopy (fs-LIBS) has been used for the first time for quantitative determination of nutrients in plant materials from different crops. A highly heterogeneous population of 31 samples, previously analyzed by inductively coupled plasma optical emission spectroscopy, covering a wide range of matrices was interrogated. To tackle the analysis, laser-induced plasmas under argon atmosphere of pellets prepared from sieved cryogenically ground leaves were studied. Predictive functions based on univariate and multivariate modeling of optical emissions associated to macro- (Ca, Mg, and P) and micronutrients (Cu, Fe, Mn and Zn) were designed. Hierarchical cluster analysis was performed to select representative calibration (ncal = 17) and validation (nval = 14) datasets. The predictive performance of calibration functions over fs-LIBS data was compared with that attained on spectral information from nanosecond LIBS (ns-LIBS) operating at different wavelengths (1064 nm, 532 nm, and 266 nm). Findings established higher accuracy and less uncertainty on mass fractions quantification from fs-LIBS, whatever the modeling approach. Quality coefficients below 20% for the accuracy error on mass fractions’ prediction in unknown samples, and residual predictive deviations in general above 5, were obtained. In contrast, only multivariate modeling satisfactorily handled the non-linear variations of emissions in ns-LIBS, leading to 2-fold decrease in the root mean square error of prediction (RMSEP) of Ca, Mg, P, Cu, Fe, Mn and Zn in comparison with the univariate approach. But still, an averaged quality coefficient about 35% and residual predictive deviations below 3 were found. Similar predictive capabilities were observed when changing the laser wavelength. Although predicted values by ns-LIBS multivariate modeling exhibit better agreement with reference mass fractions as compared to univariate functions, fs-LIBS conducts better quantification of nutrients in plant materials since it is less dependent on the chemical composition of the matrices. 相似文献
17.
Sung-Chul Choi Myoung-Kyu Oh Yonghoon Lee Sungmo Nam Do-Kyeong Ko Jongmin Lee 《Spectrochimica Acta Part B: Atomic Spectroscopy》2009
We have observed dynamic effects of a pre-ablation spark on the signal intensity in the orthogonal dual-pulse laser-induced breakdown spectroscopy. We applied pre-ablation and ablation laser pulses with significantly reduced energy for an aluminum metal in open air. Under this experimental condition, the well-known signal enhancement through the increase in ablated mass was negligible. The Al I and II emissions were investigated by both top-view and spatially-resolved side-view collection modes. In this low laser power regime, dynamic effects of a pre-ablation spark on the signal intensity were clearly revealed. The principal factor of signal enhancement is the increase in temperature. Without the mass removal enhancement, effective rarefaction leads to decrease in the Al I emission intensity and simultaneous increase in the Al II emission intensity. This is attributed to the role of Saha equilibrium. Selective prolongation of emission lifetime only for the enclosed part of the analyte plasma in the rarefied region and other fluid-dynamic effects of a pre-ablation spark have been visualized by wavelength-selected time-space correlation maps of plasma emissions. 相似文献
18.
V. Lazic A. Palucci S. Jovicevic C. Poggi E. Buono 《Spectrochimica Acta Part B: Atomic Spectroscopy》2009,64(10):1028
With the aim of realizing a compact instrument for detection of energetic materials at trace levels, laser induced breakdown spectroscopy was applied on residues from nine explosives in air surroundings. Different potentially interfering organic materials were also analyzed. The residues were not uniformly distributed on an aluminum support and single-shot discrimination was attempted. For a single residue type, large shot-to-shot fluctuations of the line intensity ratios characteristic for organic samples were observed, which made material classification difficult. It was found that both atomic and molecular emission intensities, as well as their ratios, are strongly affected by an amount of the ablated support material, which mainly determines the plasma temperature. With respect to the spectra from the clean support, emission intensities of atomic oxygen and nitrogen are always reduced in the presence of an organic material, even if its molecules contain these elements. This was attributed to chemical reactions in a plasma containing carbon or its fragments. Hydrogen atomic emission depends strongly on the local humidity above the sampled point and its line intensity shows shot to shot variations up to 50%, also on a homogeneous sample. It is argued that shock waves generated by previous spatially and/or temporally close laser pulses blow away a relatively heavy water aerosol, which later diffuses slowly back towards the sampled point. C2 and CN exhibit a peak emission behavior with atomic Al emission, and their variable ratio indicates an existence of different formation or removal mechanisms from the plasma, depending on the plasma parameters and on the composition of the organic residue. On the basis of these observations, an attempt is made to establish a suitable procedure for data analysis and to determine the optimal experimental conditions, which would allow for discrimination of explosives from other, potentially interfering, residues. 相似文献
19.
20.
Arnab Sarkar 《Talanta》2009,78(3):800-1664
Laser-induced breakdown spectroscopy (LIBS) has been developed for determining the percentage of uranium in thorium-uranium mixed oxide fuel samples required as a part of the chemical quality assurance of fuel materials. The experimental parameters were optimized using mixed oxide pellets prepared from 1:1 (w/w) mixture of thorium-uranium mixed oxide standards and using boric acid as a binder. Calibration curves were established using U(II) 263.553 nm, U(II) 367.007 nm, U(II) 447.233 nm and U(II) 454.363 nm emission lines. The uranium amount determined in two synthetic mixed oxide samples using calibration curves agreed well with that of the expected values. Except for U(II) 263.553 nm, all the other emission lines exhibited a saturation effect due to self-absorption when U amount exceeded 20 wt.% in the Th-U mixture. The present method will be useful for fast and routine determination of uranium in mixed oxide samples of Th and U, without the need for dissolution, which is difficult and time consuming due to the refractory nature of ThO2. The methodology developed is encouraging since a very good analytical agreement was obtained considering the limited resolution of the spectrometer employed in the work. 相似文献