首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A double accumulation and stripping steps were proposed to increase the sensitivity of Co(II) determination by catalytic adsorptive stripping voltammetry (AdSV). Electrodes with large and small surface area were used for the first and second accumulation step, respectively. As the accumulation of Co(II) complex at the first electrode was finished, the electrode was placed at a short distance opposite the second one. Then the Co(II) complex desorbed from the first electrode was accumulated at the second electrode. Taking into account the small volume of space between the electrodes, the concentration of the Co(II) complex in solution between the electrodes was drastically higher than that in the bulk solution. The accumulation step at the second electrode was performed from the solution with higher concentration of Co(II) and therefore the detection limit was lowered. The calibration graph of Co(II) determination for accumulation time of 120 s at both electrodes was linear from 1.18 to 58.9 ng L?1. The detection limit for Co(II) was equal to 0.47 ng L?1 and it is so far the lowest detection limit obtained for Co(II) using mercury-free electrodes. The proposed method was applied to Co(II) determination in water certified reference material.  相似文献   

2.
The article reports on utilization of double deposition and stripping steps for increasing sensitivity of Cu(II) determination by anodic stripping voltammetry (ASV) at two lead film working electrodes. A significant preconcentration of copper was achieved thanks to utilization of a simple design of four electrodes system that gives possibility to perform one measurement cycle consisting of two deposition and two stripping steps. Due to the fact that deposition step is doubled, the concentration of Pb(II) needed to lead film electrodes formation was significantly reduced as compared to traditional procedures using three electrodes system. The analytical procedure of Cu(II) determination was optimized. The experimental factors: supporting electrolyte's pH and its concentration, lead ions concentration, potential and time of deposition at both working electrodes were studied. The Cu(II) peak current was linearly dependent on its concentration from 5×10?10 to 2×10?8 mol L?1 (deposition time of 270 and 160 s at the first and the second working electrode, respectively). The obtained detection limit for copper ions determination was 2.1×10?10 mol L?1. The described procedure was validated by analysis of two water certified reference materials. The described procedure was also utilized for real water sample analysis.  相似文献   

3.
Lin L  Lawrence NS  Thongngamdee S  Wang J  Lin Y 《Talanta》2005,65(1):144-148
A sensitive adsorptive stripping voltammetric protocol at a bismuth-coated glassy-carbon electrode for trace measurements of chromium (VI) in the presence of diethylenetriammine pentaacetic acid (DTPA) is described. The new protocol is based on accumulation of the Cr-DTPA complex at a preplated bismuth film electrode held at −0.80 V, followed by a negatively-going square-wave voltammetric waveform. Factors influencing the stripping performance including the film preparation, solution pH, DTPA and nitrate concentrations, deposition potential and deposition time, have been optimized. The resulting performance compares well with that observed for analogous measurements at mercury film electrodes. A preconcentration time of 7 min results in a detection limit of 0.3 nM Cr(VI) and after 2 min a relative standard deviation at 20 nM of 5.1% (n = 25). Applicability to river water samples is demonstrated. The attractive behavior of the new “mercury-free” chromium sensor holds great promise for on-site environmental and industrial monitoring of chromium (VI). Preliminary data in this direction using bismuth-coated screen-printed electrodes are encouraging.  相似文献   

4.
Carbon and gold microdisc electrodes (30 and 10 μm, respectively) have been tested as substrates for in situ bismuth film plating from unstirred solutions of variable acetate buffer content and were subsequently used in the anodic stripping voltammetry determination of Pb(II) and Cd(II) ions. The effects of Bi(III) concentration, analyte accumulation time, stirring as well as supporting electrolyte content have been studied. Under optimal conditions good voltammetric responses were obtained by means of square wave anodic stripping voltammetry in unstirred analyte solutions of 5 × 10−8 to 10−6 M, even in the absence of added buffer. In an indicative application, Pb(II) ion levels were determined in tap water using bismuth-plated carbon microdisc electrodes.  相似文献   

5.
Cathodic stripping voltammetry of trace Mn(II) at carbon film electrodes   总被引:1,自引:0,他引:1  
Filipe OM  Brett CM 《Talanta》2003,61(5):643-650
A sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 Ω. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO2 nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO2 nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated.  相似文献   

6.
Sensitive voltammetric methods using cathodic and anodic differential pulse stripping techniques were applied for determination of trace ions cadmium(II), cobalt(II), copper(II), lead(II), manganese(II), nickel(II), and zinc(II), which are usually found in different grades of common salt as contaminants. The optimal conditions, i.e., deposition time, preconcentration potential, supporting electrolyte, and ionic strength, were investigated for each metal ion. Concentration of the metal ion was determined by the standard addition method. Metal content varied according to the quality of the table salt.  相似文献   

7.
The bismuth film electrode (BiFE), in combination with anodic stripping voltammetry, offers convenient measurement of low concentrations of tin. The procedure involves simultaneous in situ formation of the bismuth film electrode on a glassy carbon substrate electrode, together with electrochemical deposition of tin, in a non-deaerated model solution containing bismuth ions, catechol as complexing agent and the metal analyte, followed by an anodic stripping scan. The BiFE is characterized by an attractive electroanalytical performance, with two distinct voltammetric stripping signals corresponding to tin, accompanied with low background contributions. Several experimental parameters were optimized, such as concentration of bismuth ions and catechol, deposition potential, deposition time and pH of the model solution. In addition, a critical comparison is given with bare glassy carbon and mercury film electrodes, revealing the superior characteristics of BiFE for measurement of tin. BiFE exhibited highly linear behavior in the examined concentration range from 1 to 100 μg L−1 of tin (R2 = 0.997), an LoD of 0.26 μg L−1 tin, and good reproducibility with a calculated R.S.D. of 7.3% for 10 μg L−1 tin (n = 10). As an example, the practical applicability of BiFE was tested with the measurement of tin in a real sample of seawater.  相似文献   

8.
A sensitive and selective method for the determination of lead(II) with a 1,4-bis(prop-2'-enyloxy)-9,10-anthraquinone (AQ) modified carbon paste electrode has been developed. The method is based on non-electrolytic preconcentration via complex formation with modifier, followed by an accumulation period with a negative potential (-1.5 V), and then by a proper anodic stripping. The analytical performance was evaluated with respect to the quantity of modifier in the paste, concentration of electrolyte solution, preconcentration time, lead(II) concentration, and other variables. A linear calibration graph was obtained in the concentration range 2.00x10(-9)-1.06x10(-5) M Pb(II) (n=21, r=0.9999) with 30 s preconcentration time. The detection limit was found to be 1x10(-9) M. For eight preconcentration/determination cycles, the differential pulse voltammetric response was reproduced with 5.0 and 3.7% relative standard deviations at 2.00x10(-8) and 2.00x10(-6) M Pb(II), respectively. Rapid and convenient renewal of electrode surface allows the use of a single modified electrode surface in multiple analytical determinations over several weeks. Many coexisting metal ions had little or no effect on the determination of lead(II). The developed method was applied to lead determination in waste waters.  相似文献   

9.
The most essential limitation of batch-injection analysis (BIA) methodology compared to other flow methods (CFA, FIA, SIA) is the lack of possibility of on-line sample processing in the measuring system. Some procedures of on-line sample pretreatment in BIA are possible by changing the plastic tip of the automatic micropipette used for sample injection into a flow-through reactor, e.g. by packing it with a bed of a solid sorbent. This concept is employed in the voltammetric stripping determinations of trace metals using a bed of commercial chelating resin Chelex-100. It was found that, besides the electrochemical preconcentration of analytes in the form of amalgams on the surface of mercury thin film electrodes, an approximately 10-fold additional preconcentration can be achieved on the packed sorbent bed by using different volumes of aspirated sample solution and eluent. This procedure allows also efficient elimination of some matrix effects.  相似文献   

10.
《Electroanalysis》2006,18(1):59-63
Bismuth‐film electrodes on glassy‐carbon substrates have been successfully applied for adsorptive‐stripping voltammetric measurements of trace molybdenum in the presence of chloranilic acid (CAA). The procedure is based on the preconcentration of the molybdenum‐chloranilic acid complex at a preplated bismuth film electrode held at ?0.55 V (vs. Ag/AgCl), followed by a negatively‐sweeping square‐wave voltammetric scan. Factors influencing the adsorptive stripping performance, including different ligands, solution pH, CAA concentration, preconcentration time and potential, have been optimized. The response compares favorably with that observed at mercury film electrodes, and is linear over the 5–50 μg/L Mo concentration range (one min preconcentration). A detection limit of 0.2 μg/L molybdenum is obtained following a 10 min accumulation. High stability is indicated from the reproducible response of a 100 μg/L molybdenum solution (n= 60; RSD=2.6%). Applicability to seawater samples is demonstrated.  相似文献   

11.
A new stripping method for the determination of arsenic in water samples with a gold film-plated carbon paste electrode has been developed for the use in constant current stripping analysis (CCSA). In the novelized procedure, differentiation between As(III) and chemically pre-reduced As(V), the effect of Cu(II) on the response of arsenic, and the stability of sample solutions were studied in detail. Compared to the voltammetric approach, the method utilizing CCSA offers a more rapid procedure with improved analytical characteristics such as reproducibility, selectivity over the Cu(II) ions, or lower detection limit (3 ppb for As(III) and 0.5 ppb for As(V), respectively). The possibilities of the optimized method are demonstrated by determinations of As(III), As(V), and total arsenic in samples of polluted river water.  相似文献   

12.
This research introduces the design of an adsorptive stripping voltammetric method for the cerium(III) determination at a carbon paste electrode, chemically modified with dipyridyl‐functionalized nanoporous silica gel (DPNSG‐CPE). The electroanalytical procedure comprised two steps: the Ce(III) chemical accumulation at ?200 mV followed by the electrochemical detection of the Ce(III)/dipyridyl complex, using anodic stripping voltammetry. The factors, influencing the adsorptive stripping performance, were optimized including the modifier quantity in the paste, the electrolyte concentrations, the solution pH and the accumulation potential or time. The resulting electrode demonstrated a linear response over a wide range of Ce(III) concentration (1.0–28 ng mL?1). The precision for seven determinations of 4 and 10 ng mL?1 Ce(III) was 3.2% and 2.5% (relative standard deviation), respectively. The prepared electrode was used for the cerium determination in real samples and very good recovery results were obtained.  相似文献   

13.
The adsorption properties of dioxouranium (II)-Phathalate complexes onto hanging mercury drop electrode are exploited in developing a highly sensitive and selective stripping voltammetric procedure for the determination of uranium (VI). The reduction current of adsorbed complex ions of U(VI) was measured by both linear sweep (LSCSV) and differential pulse cathodic stripping voltammetry (DPCSV), preceded by a period of preconcentration onto the electrode surface. As low as 2x10(-9) mol dm(-3) (0.5 mug/l) and 2x10(-8) mol dm(-3) (4.8 mug/l) with accumulation time 240 and 120 s using DPCSV and LSCSV, respectively, have been determined successfully. The relative standard deviation of 2.2% at the 5 ppm level was obtained. The interferences of some metal ions and anions were studied. The application of this method was tested in the determination of uranium in superphosphate fertilizer.  相似文献   

14.
An improved approach to the anodic stripping voltammetric (ASV) determination of heavy metals, using the hanging mercury drop electrode (HMDE), is reported. It was discovered that using very cathodic accumulation potentials, at which the solvent reduction occurs (overpotential deposition), the voltammetric signals of zinc(II), cadmium(II), lead(II) and copper(II) increase. When compared with the classical methodology a 5 to 10-fold signal increase is obtained. This effect is likely due to both mercury drop oscillation at such cathodic potentials and added local convection at the mercury drop surface caused by the evolution of hydrogen bubbles.  相似文献   

15.
Wang J  Lu D  Thongngamdee S  Lin Y  Sadik OA 《Talanta》2006,69(4):914-917
Bismuth-coated glassy carbon electrodes have been successfully applied for catalytic adsorptive stripping voltammetric measurements of low levels of vanadium(V) in the presence of chloranilic acid (CAA) and bromate ion. The new protocol is based on the accumulation of the vanadium-chloranilic acid complex from an acetate buffer (pH 5.5) solution at a preplated bismuth film electrode held at −0.35 V (versus Ag/AgCl), followed by a square-wave voltammetric scan. Factors influencing the adsorptive stripping performance, including the CAA and bromate concentrations, solution pH, and accumulation potential or time have been optimized. The response compares favorably with that observed at mercury film electrodes. A linear response is observed over the 5-25 μg/L concentration range (2 min accumulation), along with a detection limit of 0.20 μg/L vanadium (10 min accumulation). High stability is indicated from the reproducible response of a 50 μg/L vanadium solution (n = 25; R.S.D. = 3.1%). Applicability to a groundwater sample is illustrated.  相似文献   

16.

The two adsorptive stripping voltammetric approaches for detection and quantitative determination of diethyl (2E)-2-{(2E)-[1-(4-methylphenyl)imidazolidin-2-ylidene]hydrazinylidene}butanedioate (DIB)—a novel molecule of medical importance—using two sensitive sensors based on modified glassy carbon electrodes as reusable sensors, were developed for the first time. The proposed electrochemical methods are based on adsorptive/reductive behaviour of DIB at two modified carbonic electrodes: a bismuth film-modified glassy carbon electrode (BiF/GCE) and a lead film-modified glassy carbon electrode (PbF/GCE). The electron gain mechanism for the electrochemical reduction of DIB on both developed sensors was proposed for the first time. To achieve the highest sensitivity in adsorptive stripping determinations, various experimental variables (e.g. the composition and pH of the supporting electrolytes, deposition conditions of bismuth and lead films, concentrations of plating solutions, accumulation times and potentials of DIB, etc.) were extensively examined. The comparison of validation parameters obtained during the determination of DIB at two sensors was presented. The excellent linear correlation was found between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 15–600 μg L−1 at an accumulation time of 30 s (with LOD = 4.2 μg L−1 and LOQ = 14.0 μg L−1) using the BiF/GCE as a sensor. Furthermore, the excellent linear relationship was confirmed between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 9–900 μg L−1 at an accumulation time of 10 s (with better LOD = 1.5 μg L−1 and LOQ = 5.0 μg L−1), employing the PbF/GCE as a sensor. The two optimized adsorptive stripping voltammetric approaches—as facile, sensitive, reliable and inexpensive—were successfully used as first methods for the quantitative analysis of a novel anticancer agent (DIB) in its pure pharmaceutically acceptable form. However, the practical applicability of square-wave adsorptive stripping voltammetric determination of the electroactive DIB molecule at a PbF/GCE, as the modified electrode of higher sensitivity, was presented after its successful solid phase extraction from a real serum sample.

  相似文献   

17.
A bismuth bulk electrode (BiBE) has been investigated as an alternative electrode for the anodic stripping voltammetric (ASV) analysis of Pb(II), Cd(II), and Zn(II). The BiBE, which is fabricated in-house, shows results comparable to those of similar analyses at other Bi-based electrodes. Metal accumulation is achieved by holding the electrode potential at −1.4 V (vs. Ag/AgCl) for 180 s followed by a square wave voltammetric stripping scan from −1.4 to −0.35 V. Calibration plots are obtained for all three metals, individually and simultaneously, in the10-100 μg L−1 range, with a detection limit of 93, 54, and 396 ng L−1 for Pb(II), Cd(II), Zn(II), respectively. A slight reduction in slope is observed for Cd(II) and Pb(II) when the three metals are calibrated simultaneously vs. individually. Comparing the sensitivities of the metals when calibrated individually vs. in a mixture reveals that Zn(II) is not affected by stripping in a mixture. However, Pb(II) and Cd(II) have decreasing sensitivities in a mixture. The optimized method has been successfully used to test contaminated river water by standard addition. The results demonstrate the ability of the BiBE as an alternative electrode material in heavy metal analysis.  相似文献   

18.
An in-situ antimony film screen-printed carbon electrode (in-situ SbSPCE) was successfully used for the determination of Cu(II) simultaneously with Cd(II) and Pb(II) ions, by means of differential pulse anodic stripping voltammetry (DPASV), in a certified reference groundwater sample with a very high reproducibility and good trueness. This electrode is proposed as a valuable alternative to in-situ bismuth film electrodes, since no competition between the electrodeposited copper and antimony for surface sites was noticed. In-situ SbSPCE was microscopically characterized and experimental parameters such as deposition potential, accumulation time and pH were optimized. The best voltammetric response for the simultaneous determination of Cd(II), Pb(II) and Cu(II) ions was achieved when deposition potential was −1.2 V, accumulation time 120 s and pH 4.5. The detection and quantification limits at levels of μg L−1 suggest that the in-situ SbSPCE could be fully suitable for the determination of Cd(II), Pb(II) and Cu(II) ions in natural samples.  相似文献   

19.
An antimony film electrode (SbFE) was prepared in situ on a glassy carbon support and in a new supporting electrolyte, a saturated solution of hydrogen potassium tartrate in which Sb(III) ions were complexed using tartrate. Its performance in anodic stripping voltammetric (ASV) determination of Cd(II), Pb(II), Zn(II), Tl(I), In(III) and Cu(II) traces was examined. It was found that 1.2 mg/L of Sb(III) yields the finest quality SbFE for analytical purposes. The procedure with in situ SbFE ensures well‐defined anodic stripping voltammetric curves of the investigated elements, low detection limits (0.5–3.8 µg/L), good reproducibility (1–5 %) and satisfactory sensitivity (32–184 nA/(µg/L)).  相似文献   

20.
Conditions were studied for the stripping voltammetric determination of components of the Cd(II)-Pb(II)-Cu(II) system in aqueous solutions of (polyethylene imine)methylthiourea (PMT), the most efficient polymer complexant for the membrane preconcentration of heavy metal ions. It was shown that PMT significantly enhances the selectivity of determining Pb(II) and Cd(II) in solutions of Cu(II) by stripping voltammetry. Pb(II) and Cd(II) can be determined in the presence of up to 200- and 50-fold amounts of Cu(II), respectively. The limits of detection for Pb(II) and Cd(II) after a 40-s accumulation were 6.9 x 10-8 and 6.8 x 10-7 M, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏