1.
A capillary zone electrophoresis (CZE) method is proposed for the quantitative determination of anthocyanins in wine as an alternative to high-performance liquid chromatography. The CZE separation was carried out using a 46 cm (effective length)×75 μm I.D. fused-silica capillary at 10 °C and a 50 mM sodium tetraborate buffer at pH 8.4 with 15% of methanol as modifier. A voltage of 25 kV and a hydrodynamic injection of 300 mbar s were used. The electropherograms were recorded at 599 nm. It was found that SO2 (antibacterial and antioxidant agent added to wine during its production) increased the absorbance of anthocyanins at 599 nm in a basic medium. Therefore, a concentration of 250 mg/l of SO2 was added to the samples and the calibration solution before the analysis in order to avoid errors by this matrix effect. The analytical response was linear (R=0.998) between 10 and 700 μg/ml of malvidin-3-O-glucoside. The limit of detection and the reproducibility (as a relative standard deviation, n=11) were 1 μg/ml and 1.5%, respectively. Finally, the CZE method was validated by the analysis of synthetic wine samples (errors less than 8%) and by the comparison of the results obtained in the analysis of different monovarietal wines by CZE with those obtained by the standard HPLC method. In this comparison, a good correlation (R=0.998) with a slope of 1.005±0.044 and an intercept of −0.752±6.690 was obtained for malvidin-3-O-glucoside.  相似文献   

2.
Rostampour L  Taher MA 《Talanta》2008,75(5):1279-1283
Natural clinoptilolite was used as a sorbent material for solid phase extraction and preconcentration of vanadium. The clinoptilolite was first saturated with a cation such as nickel(II) and then modified with benzyldimethyltetradecyleammonium chloride (BDTA) for increasing sorption of 4-(2-pyridylazo)resorcinol (PAR). Vanadium–PAR complex was quantitatively retained on the sorbent by the column method at the pH range 6.2–7.0 at a flow rate of 1 mL min−1. It was removed from the column with 5.0 mL of dimethylformamide solution at a flow rate of 0.8 mL min−1 and determined by UV–vis spectrophotometry at λmax = 550 nm. 0.031 μg of vanadium can be concentrated from 450 mL of aqueous sample (where detection limit as 0.07 ng mL−1 with preconcentration factor of 90). Relative standard deviation for eight replicate determination of 5.0 μg of vanadium in final solution is 2.1%. The interference of number of anions and cations has been studied in detail to optimize the conditions and method was successfully applied for determination of all vanadium as V(IV) form in standard samples.  相似文献   

3.
A novel method for the spectrophotometric determination of nitrite in water   总被引:4,自引:0,他引:4  
Aydın A  Ercan O  Taşcıoğlu S 《Talanta》2005,66(5):1181-1186
A rapid, simple, selective and sensitive method for the spectrophotometric determination of nitrite in water has been developed and optimum reaction conditions along with other analytical parameters have been evaluated. Nitrite reacts with barbituric acid in acidic solution to give the nitroso derivative, violuric acid. At analytical wavelength of 310 nm, Beer's law is obeyed over the concentration range 0.00–3.22 ppm of nitrite. The molar absorptivity is 15330 ± 259.7 (95%) with pooled standard deviation of 355.57 and R.S.D. of 2.32%. As well as the method is sensitive (2.99 × 10−3 μg NO2 cm−2) and selective, it tolerates most of the potential interferents. It has been successfully applied to nitrite determination in natural waters by use of a calibration graph with determination limit of 1.66 μg NO2 in 100 mL working solution corresponding to minimum 9.5 ppb NO2–N in water samples. Lower concentrations of nitrite (3.0 μg NO2/L sample) is precisely analyzed by using the method of dilution with sample, with R.S.D. of lower than 0.5%. The results were compared with standard N-(1-naphtyl)ethylenediamine dihydrochloride method and very good agreement between the data was observed. The method can easily be applied in the field.  相似文献   

4.
The paper presents a rapid method for the determination of dioxopromethazine hydrochloride (DPZ), an antihistamine drug, by the capillary electrophoresis with electrochemiluminescene detection (CE–ECL) using tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) reagent. This CE–ECL detection method has high sensitivity, good selectivity and reproducibility for DPZ analysis. Under the optimized conditions: separation capillary, 38 cm length (25 μm i.d.); sample injection, 10 s at 8 kV; separation voltage, 12.5 kV; running buffer, 20 mmol L−1 sodium phosphate of pH 6.0; detection potential, 1.15 V; 50 mmol L−1 of phosphate buffer (pH 7.14) containing 5 mmol L−1 of Ru(bpy)32+ in ECL detection cell, the detection limit of DPZ was 0.05 μmol L−1 (S/N = 3). The linear range extended from 5 to 100 μmol L−1. The linear curve obtained was Y = 181.62 + 9.28X with a correlation coefficient of 0.9970. The relative standard deviations of the ECL intensity and the migration time for six continuous injections of 5 μmol L−1 DPZ were 3.7% and 0.92%, respectively. The CE–ECL method was applied to analyze DPZ in real samples including tablets, rat serum and human urine, and satisfactory results were obtained without interference from samples matrix. The CE–ECL technique was proved to be a potential method for the detection of DPZ in clinic analysis.  相似文献   

5.
An analytical method for the determination of polybrominated diphenyl ethers (PBDEs) in soil was developed. Soil samples were placed in small glass columns and PBDEs extracted from soil, with a low volume of ethyl acetate (5 mL, 2× 15 min), assisted by sonication. PBDEs were determined by gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC–MS–SIM) and residues were confirmed by their retention times, selected ions and qualifier–target abundance ratios. Recovery studies were performed at 10, 1, 0.1 and 0.05 μg/kg fortification levels, and the recoveries obtained ranged from 81 to 104% with a relative standard deviation between 1 and 9%. The detection limit of the method varied from 2 to 30 pg/g and the quantification limit ranged from 7 to 100 pg/g for the different PBDEs studied. The developed method was linear over the range assayed, 0.01–10 μg/kg with determination coefficients equal or higher than 0.997. The proposed method was used to determine PBDEs levels in soil samples from different areas of Spain and PBDEs were detected in some samples with values ranging from 1.3 to 5.6 μg/kg.  相似文献   

6.
A micellar electrokinetic capillary chromatography method was developed that permitted the resolution of antipyrine from endogenous compounds and its quantitation in neat saliva in as little as 1 min. Final conditions were: SpectraPhoresis 1000, 30(23) cm × 50 μm silica capillary, 50 mM sodium phosphate pH 9.6, 50 mM SDS, 10 s hydrodynamic load, detection scanning 200–300 nm or 260 nm, run 25 kV. To overcome the effects of Joule heating the capillary was cooled to 15°C. Sensitivity was <10 μM and linearity extended to 350 μM. Comparison with an HPLC assay demonstrated that hydrodynamic injection gave a loading bias unless samples and standards were of equal viscosity. For 75 samples from five subjects the correlation of CE vs. HPLC was then r = 0.99.  相似文献   

7.
γ-Hydroxybutyric acid (GHB), a minor metabolite or precursor of γ-aminobutyric acid (GABA), acts as a neurotransmitter/neuromodulator via binding to GABA receptors and to specific presynaptic GHB receptors. Based upon the stimulatory effects, GHB is widely abused. Thus, there is great interest in monitoring GHB in body fluids and tissues. We have developed an assay for urinary GHB that is based upon liquid–liquid extraction and capillary zone electrophoresis (CZE) with indirect UV absorption detection. The background electrolyte is composed of 4 mM nicotinic acid (compound for indirect detection), 3 mM spermine (reversal of electroosmosis) and histidine (added to reach a pH of 6.2). Having a 50 μm I.D. capillary of 40 cm effective length, 1-octanesulfonic acid as internal standard, solute detection at 214 nm and a diluted urine with a conductivity of 2.4 mS/cm, GHB concentrations ≥2 μg/ml can be detected. Limit of detection (LOD) and limit of quantitation (LOQ) were determined to be dependent on urine concentration and varied between 2–24 and 5–60 μg/ml, respectively. Data obtained suggest that LOD and LOQ (both in μg/ml) can be estimated with the relationships 0.83 κ and 2.1 κ, respectively, where κ is the conductivity of the urine in mS/cm. The assay was successfully applied to urines collected after administration of 25 mg sodium GHB/kg body mass. Negative electrospray ionization ion-trap tandem mass spectrometry was used to confirm the presence of GHB in the urinary extract via selected reaction monitoring of the m/z 103.1→m/z 85.1 precursor–product ion transition. Independent of urine concentration, this approach meets the urinary cut-off level of 10 μg/ml that is required for recognition of the presence of exogenous GHB. Furthermore, data obtained with injection of plain or diluted urine indicate that CZE could be used to rapidly recognize GHB amounts (in μg/ml) that are ≥ 4 κ.  相似文献   

8.
It has been developed an automatic stop-flow procedure for sequential photometric determination of anionic and cationic surfactants in a same sample of water. The flow system was based on multicommutation process that was designed employing two solenoid micro-pumps and six solenoid pinch valves, which under microcomputer control carry out fluid propelling and reagent solutions handling. A homemade photometer using a photodiode as detector and two light emitting diodes (LEDs) with emission at 470 nm (blue) and 650 nm (red) as radiation sources, which was tailored to allow the determination of anionic and cationic surfactants in waters. The procedure for anionic surfactant determination was based on the substitution reaction of methyl orange (MO) by the anionic surfactant sodium dodecylbenzene sulfonate (DBS) to form an ion-pair with the cetyl pyridine chloride (CPC). Features such as a linear response ranging from 0.35 to 10.5 mg L−1 DBS (R = 0.999), a detection limit of 0.06 mg L−1 DBS and a relative standard deviation of 0.6% (n = 11) were achieved. For cationic surfactant determination, the procedure was based on the ternary complex formation between cationic surfactant, Fe(III) and chromazurol S (CAS) using CPC as reference standard solution. A linear response range between 0.34 and 10.2 mg L−1 CPC (R = 0.999), a detection limit of 0.05 mg L−1 CPC and a relative standard deviation of 0.5% (n = 11) were obtained. In both cases, the sampling throughput was 60 determinations per hour. Reagents consumption of 7.8 μg MO, 8.2 μg CPC, 37.2 μg CAS and 21.6 μg Fe(III) per determination were achieved. Analyzing river water samples and applying t-test between the results found and those obtained using reference procedures for both surfactant types provide no significant differences at 95% confidence level.  相似文献   

9.
Automated sequential injection (SIA) method for chemiluminescence (CL) determination of nonsteroidal anti-inflammatory drug indomethacin (I) was devised. The CL radiation was emitted in the reaction of I (dissolved in aqueous 50% v/v ethanol) with intermediate reagent tris(2,2′-bipyridyl)ruthenium(III) (Ru(bipy)33+) in the presence of acetate. The Ru(bipy)33+ was generated on-line in the SIA system by the oxidation of 0.5 mM tris(2,2′-bipyridyl)ruthenium(II) (Ru(bipy)32+) with Ce(IV) ammonium sulphate in diluted sulphuric acid. The optimum sequence, concentrations, and aspirated volumes of reactant zones were: 15 mM Ce(IV) in 50 mM sulphuric acid 41 μL, 0.5 mM Ru(bipy)32+ 30 μL, 0.4 M Na acetate 16 μL and I sample 15 μL; the flow rates were 60 μL s−1 for the aspiration into the holding coil and 100 μL s−1 for detection. Calibration curve relating the intensity of CL (peak height of the transient CL signal) to concentration of I was curvilinear (second order polynomial) for 0.1–50 μM I (r = 0.9997; n = 9) with rectilinear section in the range 0.1–10 μM I (r = 0.9995; n = 5). The limit of detection (3σ) was 0.05 μM I. Repeatability of peak heights (R.S.D., n = 10) ranged between 2.4% (0.5 μM I) and 2.0% (7 μM I). Sample throughput was 180 h−1. The method was applied to determination of 1 to 5% of I in semisolid dosage forms (gels and ointments). The results compared well with those of UV spectrophotometric method.  相似文献   

10.
Hydrogen peroxide in basic media is proposed as a means for dissolving whole blood samples to be analyzed by electrothermal atomization atomic absorption spectrometry, ET AAS. Approximately 2 g of the whole blood sample were directly weighed in a 150 mL volumetric flask; 3 mL of a NaOH 0.2 mol L−1 solution, two drops of 1-octanol, as an antifoaming agent, and 1 mL of 30% volume hydrogen peroxide were added to the flask to promote oxidation. The solution was then manually shaken and after approximately three minutes of shaking, a clear solution, with no apparent suspended solids or greasy layers, was obtained. Distilled-deionized water was used to complete the volume. Ten μL of the resulting solution along with 10 μL of a solution containing 5000 mg L−1 of NH4H2PO4 and 300 mg L−1 of Mg(NO3)2 as a modifier, were injected into transversely heated graphite tubes for lead determination. Both aqueous standards and standard addition calibration curves produced results not significantly different at a 95% confidence limit level. Accuracy of the measurements was assessed by analysis of the IAEA A-13 (concentration of trace and minor elements in freeze dried animal blood) standard reference material containing 0.18 mg L−1 lead on a dry basis and by means of recovery tests. Analysis of the IAEA A-13 standard produced 0.17 ± 0.02 mg L−1 lead on a dry basis; recovery tests afforded values from 95 to 105%. Ten consecutive measurements of a 5 ppb lead solution gave a characteristic mass of 47.2 pg and a (3S) detection limit of 1.77 μg L−1 Pb. Results obtained from analysis of whole blood samples of volunteer donors covered a lead concentration range between 8 and 21 μg L−1 with a mean value of 11.9 ± 4.7 μg L−1.  相似文献   

11.
A two-dimensional biomimetic optrode for the detection and quantification of uranium in natural waters was fabricated. The sensing element was designed by the inclusion of uranyl ion imprinted polymer particles into polymethyl methacrylate followed by casting a thin film on a glass slide without any plasticizer. The ion imprinted polymer material was prepared via covalent immobilization of the newly synthesised ligand 4-vinyl phenylazo-2-naphthol by thermal polymerization. Operational parameters such as pH, response time and the amount of sensing material were optimized. The response characteristics of the imprinted and the corresponding non-imprinted polymer inclusion optrodes of uranium were compared under optimum conditions. The imprinted polymer inclusion optrode responds linearly to uranium in the concentration range 0–1.0 μg mL−1 with a detection limit of 0.18 μg mL−1, which is much better than the solution studies using 4-vinyl phenylazo-2-naphthol (1.5 μg mL−1). Triplicate determinations of 100 μg of uranium(VI) present in 250 mL of solution gave a mean absorbance of 0.018 with a relative standard deviation of 8.33%. The superior sensitivity of imprinted polymer inclusion optrode is exemplified by lower detection limits and broader dynamic range over non-imprinted polymer inclusion optrode. The developed imprinted polymer inclusion optrode was found to give stable and precise response for 3 months and can be used without any loss in sensitivity. The applicability for analysing ground, lake and tap-water samples collected in the vicinity of uranium deposits was successfully demonstrated.  相似文献   

12.
An on-line stacking method based on moving reaction boundary (MRB) was developed for the sensitive determination of barbital and phenobarbital in human urine via capillary electrophoresis (CE). The optimized conditions for the method are: 60 mmol L−1 pH 11.0 Gly–NaOH as the background electrolyte, 10 mmol L−1 pH 5.5 Gly–HCl as sample buffer, secobarbital as the internal standard (IS), 12.5 kV, 1.4 psi 10 s sample injection, 75 μm ID 60.2 cm total length (50 cm effective length) capillary and 214 nm detect wavelength. Under the optimized conditions, the method can well stack and separate barbital and phenobarbital in urine samples and result in 20.5-fold and 22.6-fold improvement in concentration sensitivity for barbital and phenobarbital, respectively. Furthermore, the method holds: (1) good linear calibration functions for the two target compounds (correlation coefficients r > 0.999), (2) low limits of detection (0.27 μg mL−1 for barbital and 0.26 μg mL−1 for phenobarbital), (3) low limits of quantification (0.92 μg mL−1 for barbital and 0.87 μg mL−1 for phenobarbital), (4) good precision (R.S.D. of intra-day and inter-day less than 5.38% for barbital and 1.67% for phenobarbital, respectively) and (5) high recoveries at three concentration levels (90.27–106.36% for barbital and 93.05–113.60% for phenobarbital in urine). The method is simple, sensitive and efficient, and can fit to the need of clinical and forensic toxicology.  相似文献   

13.
Perfluorinated surfactants of heptafluorobutylate and pentadecafluorooctanoate ions were adsorbed on an activated charcoal cartridge and decomposed with sodium biphenyl (SBP) reagent to form inorganic fluoride ion. The fluoride ion thus formed was determined by flow injection analysis (FIA) using quercetin-Zr complex as a fluorimetric reagent, where λex and λem were 422 and 491 nm, respectively. The limit of detection for fluoride ion by the FIA system was developed to 1.1 × 10−6 M (signal to noise ratio of three), when 50% (v/v) tetrahydrofuran (THF) was used as a dissolving solvent for quercetin. The perfluorinated surfactants in the sample solution were quantitatively adsorbed on the cartridge containing 100 mg of activated charcoal and were decomposed with 0.5 mL of sodium biphenyl reagent after drying thoroughly by flowing through dry nitrogen gas. The fluoride ion formed was recovered with 3 mL of purified water as an eluent, and it was determined by the fluorimetric flow injection system. The blank fluorescence signal accompanied during the adsorption/decomposition on the cartridge was reduced by washing the activated charcoal with acetone. The blank signal was also observed from dimethoxyethane, which was used in sodium biphenyl reagent. When 600 mL sample solution was used and 200 times enrichment was applied, the heptafluorobutylate and pentadecafluorooctanoate ions at the concentrations of 2.1 μg L−1 were quantitatively recovered as fluoride ion, and the limit of detections for the perfluorinated surfactants were 0.3 and 0.3 μg L−1 for the two perfluorinated surfactants, respectively (3 sigma of the blank signal).  相似文献   

14.
Ruengsitagoon W 《Talanta》2008,74(5):1236-1241
A simple reversed flow injection colourimetric procedure for determining iron(III) was proposed. It is based on the reaction between iron(III) with chlortetracycline, resulting in an intense yellow complex with a suitable absorption at 435 nm. A 200 μl chlortetracycline reagent solution was injected into the phosphate buffer stream (flow rate 2.0 ml min−1) which was then merged with iron(III) standard or sample in dilute nitric acid stream (flow rate 1.5 ml min−1). Optimum conditions for determining iron(III) were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range 0.5–20.0 μg ml−1. The detection limit (3σ) and the quantification limit (10σ) were 0.10 and 0.82 μg ml−1, respectively. The relatives standard deviation of the proposed method calculated from 12 replicate injections of 2.0 and 10.0 μg ml−1 iron(III) were 0.43 and 0.59%, respectively. The sample throughput was 60 h−1. The proposed method has been satisfactorily applied to the determination of iron(III) in natural waters.  相似文献   

15.
A gas chromatographic method to determine caprolactam in multilayer PA-6 films used for meat foodstuffs and cheese was developed and validated. A wide linear range (0.8–400 μg/ml), RSD4.1% and recovery higher than 90.0% were obtained for the chromatographic system, while precision and accuracy of the method showed RSD3.8%, recovery from 95.5–100.0% and LOQ of 32 μg/g. Irradiated (3, 7 and 12 kGy) and non-irradiated commercial films were analyzed. Most of them increased caprolactam levels with the increase of irradiation doses.  相似文献   

16.
建立了一种采用超声辅助提取(UAE)、强阴离子交换固相萃取(SAX-SPE)净化、高效液相色谱(HPLC)测定土壤中残留头孢菌素C(CPC)简单、快速方法。 样品以超纯水为提取剂,超声辅助提取,SPE柱子以3 mL甲醇和3 mL水活化,采用5 mL的10%甲醇水溶液作为淋洗液,2 mL的5%甲酸水溶液/甲醇溶液(体积比50:50)进行洗脱,高效液相色谱紫外检测器(HPLC-PDA)测定,检测波长λ=254 nm,柱温30 ℃ ,流动相为0.1%甲酸水溶液/甲醇溶液(体积比95:5)对土壤中不同加标浓度的CPC进行检测,方法的回收率在77.9%~98.9%,标准偏差范围为5.0%~6.3%(n=5),方法检出限(LOD)为340.4 μg/kg,定量限(LOQ)为1126.8 μg/kg。 同时采用此方法检测分析新疆某药厂附近阳性土壤样品,不同批次土壤样品结果分别为:检出(低于定量限)、1532.1 μg/kg。  相似文献   

17.
Shih Y  Zen JM  Kumar AS  Chen PY 《Talanta》2004,62(5):912-917
Zinc pyrithione (ZPT) is an antibacterial and antifungal reagent that is often utilized for the antidandruff activity in hair-care shampoos with a composition level up to 1% in the formulation. It has some adverse effects to human and animal if consumed orally. A disposable type of cobalt phthalocyanide modified screen-printed carbon electrode (CoPc/SPE) in couple with flow injection analysis (FIA) was developed for easy and selective analysis of ZPT in commercial hair-care products. Under the optimized FIA conditions, the CoPc/SPE yielded a linear calibration plot in the window of 6–576 μM with sensitivity and detection limit of 1.65 nA μM−1 and 0.9 μM (i.e. 1.42 pg in 5 μl sample loop), respectively, in 0.1 M KOH solution at an applied potential of 0.3 V versus Ag/AgCl. Since the approach is simple, easy, selective, and inexpensive, it offers a potential application of daily ZPT analysis in hair-care products.  相似文献   

18.
A simple and sensitive sequential injection spectrophotometric procedure is proposed for the determination of trace amounts of iodide in pharmaceutical preparations. The method is based on the catalytic effect of iodide on the (tetra base) 4,4′-methylenebis(N,N-dimethylaniline)-chloramine-T reaction in acidic solution. The method involves a sequential aspiration of 255 μl sample/standard followed by 170 μl tetra base and then 128 μl chloramine-T solutions into a carrier stream to be stacked inside a holding coil and flow reversed through a reaction coil towards a detector. The resulting colored compound is measured at 600 nm using an UV/Vis-spectrophotometer. All the parameters that affect the reaction were evaluated and the calibration curve is linear over a range of 0.1–6.0 μg l−1 of iodide concentration with detection limit of 0.05 μg l−1. A sample throughput of 80 samples per hour and relative standard deviation of less than 2.0% was achieved. The method is successfully applied for the determination of iodide in three different samples (tablets).  相似文献   

19.
A sensitive method based on the preconcentration of uranium on powdered polyurethane foam (PUF) has been developed to determinate this element in water samples by X-ray florescence. Uranium at ppb levels was sorbed as the salicylate complex on powdered PUF at pH 4.0. The resulting PUF was filtered through a filter paper and used for X-ray fluorescence measurements. For 50 μg/l of uranium the coefficient of variation for five measurements is 5% and the detection limit is 5.5 μg/l. The interference level of various ions and ligands was studied and optimum conditions were developed to determine uranium in reference materials, waste water, mine drainage, and sea water.  相似文献   

20.
In this work an automatic photometric procedure for the determination of chlorine in bleach samples employing N,N′-diethyl-p-phenylenediamine (DPD) as chromogenic reagent is described. The procedure was based on a falling drop system where the analyte (Cl2) was collected by a DPD solution drop (50 μL) after its delivery from the sample bulk that was previously acidified. The flow system was designed based on the multicommutation process assembling a set of three-way solenoid valves, which under microcomputer control afforded facilities to handle sample and reagent solution in order to control analyte delivering and solution drop generation. The analyte volatilization was improved by coupling online a little heating device. The detection system comprised a green LED (515 nm) and a phototransistor. Aiming to prove the usefulness of the proposed procedure a set of bleach samples was analyzed. Comparing the results with those obtained with reference method no significant difference at 95% confidence level was observed. Other profitable features such as a linear response ranging from 15 up to 100 mg L−1 Cl2 (R = 0.999); a detection limit of 4.5 mg L−1 Cl2 estimated based on the 3σ criterion; a relative standard deviation of 2.5% (n = 10) using a typical bleach sample containing 25.0 mg L−1 Cl2; a consumption of 55 μg of DPD per determination; and a analytical frequency of 20 determinations per hour were also achieved.  相似文献   