首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Zhang S  Jiao K  Chen H  Wang M 《Talanta》1999,50(1):95-101
A voltammetric enzyme-linked immunoassay based on new system of m-aminophenol (MAP)-H(2)O(2)-horseradish peroxidase (HRP) has firstly been developed and used for the detection of HRP, labelled HRP and ferritin in human serum. HRP or labelled HRP catalyzes the oxidation reaction of MAP with H(2)O(2), the product of which produces a sensitive voltammetric peak at potential of -0.46 V (vs. SCE) in Britton-Robinson (BR) buffer solution. By using this voltammetric peak, HRP can be measured with a detection limit of 9.5x10(-1) mU/l and a linear range of 2.5-2.5x10(2) mU/l. The detection limit to ferritin is 0.25 ng/ml and the linear range 0.25-320 ng/ml. The processes of the electro-reduction of the product of the enzyme-catalyzed reaction have been investigated in detail.  相似文献   

2.
A new voltammetric enzyme-linked immunoassay system of 3,3'-diaminobenzidine (DAB)-H2O2-horseradish peroxidase (HRP) has been presented and used for the sensitive detection of carcinoembryonic antigen (CEA) in human serum. In this proposed procedure, DAB was firstly used as the electroactive substrate in the HRP catalyzed oxidation reaction in the present of H2O2. The generated product produced a sensitive second-order derivative linear sweep voltammetric peak at potential of -0.62 V (vs. SCE) in Britton-Robinson (BR) buffer solution. The free HRP could be measured in a linear range from 2.5 x 10(-6)-2.5 x 10(-2) unit/ml and a detection limit of about 1.5 x 10(-6) unit/ml. Under the optimal experiment conditions, CEA could be detected in the linear range from 0.50 to 80 ng/ml with a detection limit of 0.5 ng/ml. The proposed electrochemical enzyme-linked immunosorbent assay method is simple, inexpensive, reproducible and sensitive, which shows promising for detecting CEA in the clinical diagnosis.  相似文献   

3.
OAP-H~2O~2-HRP伏安酶联免疫分析新体系测定人血清铁蛋白   总被引:3,自引:1,他引:2  
张书圣  焦奎  陈洪渊 《化学学报》1999,57(8):914-921
首次提出邻氨基酚(OAP)-H~2O~2-辣根过氧化物酶(HRP)伏安酶联免疫分析新体系并用于人血清中铁蛋白的测定.本方法以线性扫描二阶导数伏安法栓测HRP催化H~2O~2氧化OAP的产物,用于游离HRP和各种HRP标记物的测定,灵敏度均高于经典的ELISA显色光度法.测定游HPR的线性范围为1.0x10^-^1^2-4.0x10^-^9g/mL,检测限达6.0x10^-^1^3g/mL.本法对铁蛋白测定的线性范围为0.2-320ng/mL,用所建立的方法对人血清样品进行了测定,并与现行的ELISA显色光度法进行对照,二者相关性很好.对此伏安酶联免疫分析新体系的电极还原过程也进行了详细的研究.  相似文献   

4.
OT-H2O2-HRP伏安酶联免疫分析新体系   总被引:13,自引:0,他引:13  
焦奎  张书圣  韦璐  刘澄凡 《化学学报》1997,55(11):1121-1129
本文首次提出了邻联甲苯胺(OT)-H2O2-辣根过氧化物酶(HRP)伏安酶联免疫分析新体系。本方法以线性扫描二阶导数伏安法检测HRP催化H2O2氧化OT的产物, 用于游离HRP和各种HRP标记物测定, 灵敏度比经典的ELISA光度法分别高两个至四个数量级。测定游离HRP的检测限达到1.8×10^-^1^2 g/mL, 线性范围为5.0×10^-^1^2-1.0×10^-^8 g/mL。对此伏安酶联免疫分析新体系的偶合反应机理及电极还原过程也进行了详细的研究。  相似文献   

5.
PAP-H2O2-HRP伏安酶联免疫分析新体系测定人血清总甲状腺素   总被引:5,自引:1,他引:4  
目前临床检测中测定总甲状腺素(T4)的常用方法有间接血凝试验、琼脂双扩散及ELISA等方法[1].其中ELISA法是目前较为流行的检测方法,但灵敏度不高.伏安酶联免疫分析法具有广阔的应用前景[2,3].  相似文献   

6.
提出间氨基酚(MAP)-H2O2-辣根过氧化物酶(HRP)伏安酶联免疫分析新体系,并用于南方菜豆花叶病毒(SBMV)的测定.以线性扫描二阶导数伏安法检测HRP催化H2O2氧化MAP的产物,用于游离HRP及SBMV的测定,灵敏度均高于经典的ELISA显色光度法.本法对HRP测定的线性范围为1.0×10-8~1.0×10-6g/L,检测限为3.8×10-9g/L;对SBMV测定的线性范围为4.0~5000ng/mL,检测限为4.0ng/mL.用所建立的方法测定病毒感染病叶澄清液的最高稀释比为1∶1.5×105,并与现行的ELISA显色光度法进行对照,二者相关性很好.  相似文献   

7.
MAP-H~2O~2-HPR伏安酶联免疫分析新体系和光谱及电化学研究   总被引:5,自引:0,他引:5  
提出了间氨基酸(MAP)-H~2O~2-辣根过氧化物酶(HRP)伏安酶联免疫分析新体系.本方法以线性扫描二阶导数伏安法检测HRP催化H~2O~2氧化MAP的产物,用于游离HRP和各种HRP标记物的测定,灵敏度均高于经典的ELISA显色光度法.测定游离HRP的线性范围为1.0x10^-^8-1.0x10-6/L,检测限达3.8x10^-^9g/L.制备出了HRP催化H~2O~2氧化MAP的产物纯品并应用电化学分析,高效液相色谱,元素分析,紫外-可见光谱,红外光谱,^1H核磁共振谱,^1^3C核磁共振谱及质谱等技术对体系酶促反应进行了深入的研究.在选择的酶促反应条件下,生成的产物为2-氨基-5-[(3-差苯基)]-2,5-环己烯基-1,4-二酮.提出了酶催化反应机理及其产物的电极还原过程。  相似文献   

8.
Jiao K  Zhang S  Wei L  Liu C  Zhang C  Zhang Z  Liu J  Wei P 《Talanta》1998,47(5):47-1137
o-Dianisidine (ODA)-H2O2-horseradish peroxidase (HRP) voltammetric enzyme-linked immunoassay system has firstly been used for the detection of tobacco mosaic virus (TMV). HRP catalyzes strongly the oxidation reaction of ODA by H2O2, the product of which produces a sensitive second order derivative linear sweep voltammetric peak at potential of −0.56 V (versus SCE) in Britton–Robinson (BR) buffer. HRP activity has been measured with this voltammetric peak and TMV detected through immunoreaction. The detection limit for HRP is 9.25×10-7 mU l−1 and the linear range is 2.5×10−6–5.0×10−4 mU l−1. The detection limit for the clarified TMV is 0.25 ng ml−1 and the highest dilution ratio detected for the infected leaf sap is 1:8×105. The sensitivity for TMV detection with this method is higher than that with the enzyme-linked immunosorbent spectrophotometric assay (ELISA) using ODA-H2O2-HRP system. The processes of the enzyme-catalyzed reaction and the electro-reduction of the product of the enzyme-catalyzed reaction have been described.  相似文献   

9.
The electrochemical enzyme-linked immunoassay increases the sensitivity of the detection of cucumber mosaic virus (CMV) by 5-fold compared with the spectrophotometric o-phenylenediamine (OPD) enzyme-linked immunosorbent assay (ELISA). The detection limit for the purified CMV is 1.0 ng/mL and the highest dilution ratio of the infected leaf sap is 1:5.0 x 10(4). The method is based on coupling the oxidation reaction of o-aminophenol (OAP)-H2O2 catalyzed by HRP-IgG conjugate with the electro-reduction of the enzymatic product. The enzymatic product 2-aminophenoxazine-3-one exhibits a sensitive second order derivative linear-sweep voltammetric response at the potential of -0.65 V (vs. Ag/AgCl) in pH 8.0 Britton-Robinson (B-R) buffer solution. So it can be applied to the detection of the plant virus with highly improved sensitivity.  相似文献   

10.
建立了邻苯二胺(OPD)-H2O2-辣根过氧化物酶(HRP)酶联示差脉冲伏安分析体系并用于测定人血清中类风湿因子(RF),HRP催化H2O2氧化OPD所形成酶催化产物在pH2.0磷酸盐-枸橼酸缓冲溶液中于-0.18 V左右产生一灵敏示差脉冲伏安峰,RF浓度在1.25~20.0 U/mL之间与峰电流呈线性关系,应用此峰检测人血清RF的检测限低至 0.28U/mL。该法较相同条件下ELISA显色光度测定法的灵敏度增加5倍,且受干扰较少。  相似文献   

11.
以氮杂环化合物为电化学分析底物的2-氨基-3-羟基吡啶-H2O2-辣根过氧化物酶(HRP)伏安酶联免疫体系测定人血清癌胚抗原(CEA).HRP催化H2O2氧化2-氨基-3-羟基吡啶的酶促反应产物,在缓冲液中-0.36 V处产生一个灵敏的伏安还原峰,借助此峰可以测定游离的HRP,进而可用于以HRP为标记物的酶联免疫分析.对酶促反应条件和测定条件的优化反应条件为:以B-R缓冲液(pH 6.0)为反应介质,在10 mL总反应液中含有1.0 mL 0.2 mol/L B-R缓冲液、3.0 mL 8.0 mmol/L 2-氨基-3-羟基吡啶溶液以及1.5 mL 0.5 mmol/L H2O2溶液,反应温度37 ℃,反应时间30 min.最佳测定条件为:B-R缓冲液(pH 7.0)为支持电解质,在10 mL总测定溶液中含有5 mL上述总反应液、1.0 mL 0.2 mol/L B-R缓冲液.测定仪器条件:起始电位0.00 V,终止电位-0.80 V,电位扫描速度400 mV/s,滴汞静止时间7 s.在最佳的反应条件和测定条件下,新体系测定游离HRP的线性范围为4.0×10-4~1.0 μg/L; 对HRP的检出限为0.12 ng/L.新体系对CEA测定的线性范围为0.50~80.0 μg/L; 检出限为0.50 μg/L.为经典ELISA法的检出限的1/10.  相似文献   

12.
Immunoassay is one of the biochemical analytical techniques using the specific antigen antibody com-plexation for analytical purposes. It has extensive ap-plication in clinical diagnostics, prevention and cure of diseases, and virus diagnostics. The presentation and progress of immunoassay methodology are one of the greatest achievements of bioanalytical chemistry. It is estimated that several-hundred millions of immuno-analytical determinations are carried out every year all over the world. E…  相似文献   

13.
Cui Y  Tang D  Liu B  Chen H  Zhang B  Chen G 《The Analyst》2012,137(7):1656-1662
Multi-armed dendritic polyaniline nanofibers (MPANFs) were first synthesized and functionalized with horseradish peroxidase (HRP) and carcinoembryonic antibody (anti-CEA) for highly efficient electrochemical immunoassay of carcinoembryonic antigen (CEA, as a model analyte here) in this work. Transmission electron microscope (TEM) and scanning electron microscope (SEM) techniques were employed to characterize the synthesized MPANFs. By using anti-CEA-conjugated core-shell gold-Fe(3)O(4) nanocomposites (GoldMag) as immunosensing probes and biofunctionalized MPANFs as molecular tags, a new sandwich-type homogeneous immunoassay strategy was developed for the determination of CEA by coupling with a home-made flow-through magneto-controlled microfluidic device. Under optimal conditions, the electrochemical immunoassay exhibited a wide dynamic range of four orders of magnitude from 1.0 pg mL(-1) to 50 ng mL(-1) with a low detection limit of 0.1 pg mL(-1) CEA at 3σ. Intra- and inter-assay coefficients of variation were below 10%. The assayed results for clinical serum specimens with the electrochemical immunoassay were received in good accordance with the results obtained from the referenced enzyme-linked immunosorbent assay (ELISA) method.  相似文献   

14.
An improved ELISA for the determination of tobacco mosaic virus (TMV) with linear sweep voltammetry based on a new system of p-aminophenol (PAP)- H2O2- horseradish peroxidase (HRP) has been developed. The enzymatic product 3-[(4-hydroxyphenyl)amino]-4-(2-amino-5-hydroxyphenyl)-6-[(4-hydroxyphenyl)imino]-2,4-cyclohexadiene-1-one, produced from HRP catalyzing the oxidation of PAP with H2O2, yields a sensitive linear sweep voltammetric response at a potential of –0.45 V (vs. SCE) in Britton-Robinson (BR) buffer solution. By using this voltammetric peak, HRP can be measured with a detection limit of 0.4 mU/L and a linear range of 1.0 ~ 1.0 × 102 mU/ L. The detection limit for the clarified TMV is 4.0 ng/mL and the highest dilution ratio detected for the infected leaf sap is 1?:?3.9 × 106. The processes of the enzyme-catalyzed reaction and the electro-reduction of the product of the enzyme-catalyzed reaction have been investigated.  相似文献   

15.
《Analytical letters》2012,45(13):2653-2675
ABSTRACT

An electrochemical method was compared with a spectrophotometric method using a horseradish peroxidase (HRP)-based indirect enzyme-linked immunosorbent assay (ELISA) with direct antigen coating (DAC) technique for the determination of tobacco mosaic virus (TMV). In substrates for a spectrophotometric HRP-based ELISA method, was selected as the substrate for the electrochemical method as well as the spectrophotometric method. 2, 3-Diaminophenazine is the product of the oxidation of OPD with H2O2 catalyzed by HRP in the selected conditions. It is electroactive and has a sensitive voltammetric response at -0.93 V (vs. Ag/AgCl) in alkaline solution. The detection limit of free HRP, by second-order derivative linear-sweep voltammetry, is 1.1 mU/L. This method can be further used to detect TMV antigen. The peak current is linear with TMV concentration in the range of 0.25-5.0 ng/mL. The detection limit for TMV is 0.25 ng/mL and the highest dilution ratio detected for the infected leaf sap is 1:102400. Compared with the classical OPD ELISA spectrophotometric method, the detection limits of the electrochemical method for the clarified TMV and the infected leaf sap detection are about ten and four times lower, respectively.  相似文献   

16.
The electrochemical enzyme-linked immunoassay increases the sensitivity of the detection of cucumber mosaic virus (CMV) by 5-fold compared with the spectrophotometric o-phenylenediamine (OPD) enzyme-linked immunosorbent assay (ELISA). The detection limit for the purified CMV is 1.0 ng/mL and the highest dilution ratio of the infected leaf sap is 1?:?5.0 × 104. The method is based on coupling the oxidation reaction of o-aminophenol (OAP)-H2O2 catalyzed by HRP-IgG conjugate with the electro-reduction of the enzymatic product. The enzymatic product 2-aminophenoxazine-3-one exhibits a sensitive second order derivative linear-sweep voltammetric response at the potential of –0.65 V (vs. Ag/AgCl) in pH 8.0 Britton-Robinson (B-R) buffer solution. So it can be applied to the detection of the plant virus with highly improved sensitivity.  相似文献   

17.
An improved ELISA for the determination of tobacco mosaic virus (TMV) with linear sweep voltammetry based on a new system of p-aminophenol (PAP)- H2O2- horseradish peroxidase (HRP) has been developed. The enzymatic product 3-[(4-hydroxyphenyl)amino]-4-(2-amino-5-hydroxyphenyl)-6-[(4-hydroxyphenyl)imino]-2,4-cyclohexadiene-1-one, produced from HRP catalyzing the oxidation of PAP with H2O2, yields a sensitive linear sweep voltammetric response at a potential of –0.45 V (vs. SCE) in Britton-Robinson (BR) buffer solution. By using this voltammetric peak, HRP can be measured with a detection limit of 0.4 mU/L and a linear range of 1.0 ∼ 1.0 × 102 mU/ L. The detection limit for the clarified TMV is 4.0 ng/mL and the highest dilution ratio detected for the infected leaf sap is 1 : 3.9 × 106. The processes of the enzyme-catalyzed reaction and the electro-reduction of the product of the enzyme-catalyzed reaction have been investigated. Received: 17 November 1998 / Revised: 17 March 1999 / Accepted: 20 March 1999  相似文献   

18.
An improved enzyme-linked immunosorbent assay (ELISA) for the determination of southern bean mosaic virus (SBMV) with linear sweep voltammetry based on a new system of p-aminophenol (PAP)-H2O2-horseradish peroxidase (HRP) has firstly been developed. The enzymatic product 3-[(4-hydrox-yphenyl) amino]-4-(2-amino-5-hydroxyphenyl)-6-[ (4-hydrox-yphenyl)imino]-2,4-cyclohexadiene-l-one, produced from the oxidation of PAP with H2O2 catalyzed by HRP, yielded a sensitive linear sweep voltammetric response at - 0.45 V ( vs. SCE) in Britton-Robinson (BR) buffer solution. Based on the voltammetric peak, HRP can be measured with a detection limit of 0.4 mU/L and a linear range of 1.0-1.0 × 102 mU/ L. The detection limit for the SBMV is 8.0 ng/mL and the highest dilution ratio for the detection of infected leaf sap is 1: 1.5×105.  相似文献   

19.
Zhang S  Li X  Zhang F 《Electrophoresis》2007,28(23):4427-4434
A method for indirectly detecting horseradish peroxidase (HRP) was described by CE with electrochemical detection. Details of selection for optimum conditions were presented. The detection limit of free HRP was 1.09 x 10(-12) M or 0.94 zmol (S/N = 3). A novel CE-based liquid-phase binding noncompetitive enzyme immunoassay (CE-EIA) was developed. In this method, after the noncompetitive immunoreaction in liquid phase, the free enzyme (HRP)-labeled antibody (Ab*) and the bound enzyme-labeled complex (Ag-Ab*) were separated and then the system of HRP catalyzing H(2)O(2)/o-aminophenol (OAP) reaction was adopted. Prostate specific antigen (PSA), carcinoembryonic antigen (CEA), and human chorionic gonadotropin (HCG) in human serum samples were detected without any sample preparation, with the detection limits (S/N = 3) of 0.22, 0.17 and 0.30 ng/mL, respectively. This technique has been successfully applied to detect simultaneously PSA, CEA, and HCG in 12 min, upon adding these three antigens into human serum to simulate patient serum. It proves that the CE-EIA technique proposed could be developed into a sensitive and new method for simultaneous clinical assay of multianalytes.  相似文献   

20.
A rapid, simple and sensitive electrochemical assay of horseradish peroxidase (HRP) performed on disposable screen‐printed carbon electrode was developed. HRP activities were monitored by square‐wave voltammetric (SWV) measuring the electroactive enzymatic product in the presence of o‐aminophenol and hydrogen peroxide substrate solution. SWV analysis demonstrated a greater sensitivity and shorter analysis time than the widely used amperometric and differential‐pulsed voltammetric methods. The voltammetric characteristics of substrate and enzymatic product as well as the parameters of SWV analysis were optimized. Under optimized conditions, a linear response for HRP from 0.003 to 0.1 U/mL and a detection limit of 0.002 U/mL (1.25×10?15 mol in 25 μL) were obtained with a good precision (RSD=8%; n=6). This rapid and sensitive HRP assay with microliter‐assay volume could be readily integrated to portable devices and point‐of‐care (POC) diagnosis applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏