1.
The concentrations of Cd, Co, Cu, Mn, Ni, Pb, and Zn in natural and sea waters are too low to be directly determined with by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GFAAS). Specific sample preparations are requested that make possible the determination of these analytes by preconcentration or extraction. These techniques are affected by severe problems of sample contamination. In this work Cd, Co, Cu, Mn, Ni, Pb, and Zn were determined by inductively coupled plasma mass spectroscopy (ICP-MS) or by atomic absorption spectrometry, in fresh and seawater samples, after on-line preconcentration and following solvent elution with a flow injection system. Bonded silica with octadecyl functional group C18, packed in a microcolumn of 100-μl capacity, was used to collect diethyldithiocarbamate complexes of the heavy metals in aqueous solutions. The metals are complexed with a chelating agent, adsorbed on the C18column, and eluted with methanol directly in the flow injection system. The methanolic stream can be addressed to FAAS for direct determination of Cu, Ni, and Zn, or collected in a vial for successive analysis by GFAAS. The eluted samples can be also dried in a vacuum container and restored to a little volume with concentrated HNO3and Milli-Q water for analysis by ICP-MS or GFAAS.  相似文献   

2.
以3 mL HNO3和2 mL H2O2的混合消解液对烟草样品进行微波消解,采用电感耦合等离子体质谱测定了烤烟中的Mn、Zn、Cu、Se、N i、Co、Cr、As、Cd、Pb 10种微量元素的含量.结果表明:方法的检出限均低于0.02μg/g,各元素测定的RSD(n=5)均小于3%,样品加标回收率为97.35%-101.30%.方法消耗试剂少,快速准确,适合烟草中多种微量元素的同时测定.  相似文献   

3.
A new polychelatogen, AXAD-16-1,2-diphenylethanolamine, was developed by chemically modifying Amberlite XAD-16 with 1,2-diphenylethanolamine to produce an effective metal-chelating functionality for the preconcentration of Mn(II), Ni(II), Cu(II), Zn(II), Cd(II), and Pb(II) and their determination by flame atomic absorption spectrometry. Various physiochemical parameters that influence the quantitative preconcentration and recovery of metal were optimized by both static and dynamic techniques. The resin showed superior extraction efficiency with high-metal loading capacity values of 0.73, 0.80, 0.77, 0.87, 0.74, and 0.81 mmol/g for Mn(II), Ni(II), Cu(II), Zn(II), Cd(II), and Pb(II), respectively. The system also showed rapid metal-ion extraction and stripping, with complete saturation in the sorbent phase within 15 min for all the metal ions. The optimum condition for effective metal-ion extraction was found to be a neutral pH, which is a great advantage in the preconcentration of trace metal ions from natural water samples without any chemical pretreatment of the sample. The resin also demonstrated exclusive ion selectivity toward targeted metal ions by showing greater resistivity to various complexing species and more common metal ions during analyte concentration, which ultimately led to high preconcentration factors of 700 for Cu(II); 600 for Mn(II), Ni(II), and Zn(II); and 500 for Cd(II) and Pb(II), arising from a larger sample breakthrough volume. The lower limits of metal-ion detection were 7 ng/mL for Mn(II) and Ni(II); 5 ng/mL for Cu(II), Zn(II), and Cd(II), and 10 ng/mL for Pb(II). The developed resin was successful in preconcentrating metal ions from synthetic and real water samples, multivitamin-multimineral tablets, and curry leaves (Murraya koenigii) with relative standard deviations of < or = 3.0% for all analytical measurements, which demonstrated its practical utility.  相似文献   

4.
为建立大批量谷类产品中重金属元素的快速检测方法,采用快速消解法,样品于聚丙烯刻度离心管中经硝酸消解,用电感耦合等离子体质谱仪同时检测Pb、Cd、Cr、Cu、Zn、Ni、As、Hg等8种重金属元素含量。研究了消解酸用量及消解时间对结果的影响,并优化了仪器工作参数。研究结果表明,样品在120℃消解1 h后直接定容测定,各元素在实验浓度范围内线性良好,相对标准偏差RSD值1.1%~7.2%,Pb、Cd、Cr、Cu、Zn、Ni、As、Hg各元素的方法检出限分别为0.02、0.000 3、0.03、0.02、0.08、0.01、0.002和0.000 4 mg/kg。试剂用量少、简便、快捷、准确性好,适用于电感耦合等离子体质谱法定量检测稻米、小麦、玉米等谷类产品中重金属元素的含量。  相似文献   

5.
Cheng F  Xianbao W  Wuming Z  Xingyao Z 《Talanta》1999,50(2):253-259
A chromatographic method for the determination of transition metals in human hair samples is described. The method involves the separation of Cu, Pb, Zn, Ni, Co, Cd and Mn in a C18 column coated with sodium hexadecane-sulfonate (SHS) and spectrophotometric detection (520 nm) after post-column reaction of the eluted metals with 4-(2-pyridylazo)-resorcinol (PAR). The eluent was a 100 mM tartrate solution adjusted to pH 3.1 with a 2 M sodium hydroxide solution (flow-rate=1.0 ml min(-1)). A good separation of the eluted metals (specially for Cu/Pb and Zn/Ni) has been achieved. The detection limits, expressed as mug l(-1), were 2.2 (Cu), 8.0 (Pb), 2.8 (Zn), 1.5 (Ni), 1.5 (Co), 12.0 (Cd), and 1.4 (Mn). A microwave-assisted closed vessel acid digestion procedure with HNO(3)+HClO(4) (4+1 ml) was used for the hair samples solubilisation. Nineteen hair samples were analysed with the proposed method. The results were in good agreement with those obtained by atomic absorption spectrometry (AAS).  相似文献   

6.
A microwave-assisted digestion method amenable to analysis of small size biological samples (<30 mg dry mass) has been optimized for determining twelve elements (Ag, As, Cd, Co, Cu, Cr, Mn, Mo, Ni, Pb, Se and Zn) by inductively coupled plasma-mass spectrometry (ICP-MS) in breast cancerous and non-cancerous biopsies. The use of three small volume PTFE closed vials (6-mL capacity) placed inside a conventional microwave vessel allows to drastically diminishing the volume of acid needed for digestion. A Plackett-Burman experimental design was used to evaluate the robustness of the digestion procedure. Effects of nitric acid volume, need for predigestion step, microwave power and digestion time were assessed. No significant effects were found, the digestion method being robust enough to be recommended for a routine practice. The method was successfully validated against CRM BCR 185 (bovine liver), CRM NRCC TORT-2 (lobster hepatopancreas), CRM NRCC DORM-2 (dogfish muscle) and CRM NRCC DOLT-2 (dogfish liver). Procedural detection limits ranged from 0.54 to 40 ng g(-1). Within-batch precision values were less than 3%, whereas between-batch precision values were in the range 2-11%. Forty-seven biopsies from thirty-nine women were analyzed: 20 samples corresponding to mammoplasties from healthy women and 27 samples from patients suffering from cancer pathology, 19 of which corresponded to tumour and 8 to adjacent normal tissue. After applying parametric and non-parametric statistical tests, a significant accumulation of Cu, Mn, Zn and Se in cancerous tissues was demonstrated.  相似文献   

7.
Different sample pre-treatments for seafood products have been compared with determine trace elements (As, Cd, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Se and Zn) by flame atomic absorption spectrometry (FAAS) and electrothermal atomic absorption spectrometry (ETAAS). Classic pre-treatments as microwave assisted-acid digestion and the slurry sampling technique were compared with new procedures such as microwave energy or ultrasound energy assisted-acid leaching process and enzymatic hydrolysis methodologies based on the use of pronase E. The methods were applied to DORM-1 and DOLT-1 reference materials with certified contents for the studied elements. The Student-Newman-Keuls (SNK) method was used to compare with element concentration means obtained with each sample pre-treatment and also the certified concentration means in both reference materials. Multivariate techniques such as principal components analysis (PCA) was also applied to comparative purposes.  相似文献   

8.
电感耦合等离子体质谱法测定花生中34种元素   总被引:3,自引:0,他引:3  
建立了微波消解-碰撞/反应池(ORS)电感耦合等离子体质谱仪(ICP-MS)同时测定花生中的Na、Mg、Ca、Fe、Se、Mo和稀土元素等34种元素的分析方法。样品经微波消解后,在线加入内标元素45Sc、72Ge、103Rh、115In和209Bi消除基体效应,应用碰撞反应池技术,以4.5 mL/min流速的氦气作为碰撞反应气,有效消除多原子离子产生的质谱干扰。各元素的检出限为0.0003~17.37ng/mL,相对标准偏差(RSD)低于2.9%;标准物质的测定值均在标准值范围内,结果令人满意。该方法可用于花生中多种元素的同时测定。  相似文献   

9.
A novel method, combining isotope dilution with standard additions, was developed for the analysis of eight elements (Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb) in seawater. The method requires just 12 mL of sample and employs an off-line pre-concentration step using the commercially available chelating resin Toyopearl AF-Chelate-650M prior to determination by high resolution inductively coupled plasma magnetic sector mass spectrometry (ICP-MS). Acidified samples were spiked with a multi-element standard of six isotopes (57Fe, 62Ni, 65Cu, 68Zn, 111Cd and 207Pb) enriched over natural abundance. In addition, standard additions of a mixed Co and Mn standard were performed on sub-sets of the same sample. All samples were irradiated using a low power (119 mW cm−2; 254 nm) UV system, to destroy organic ligands, before pre-concentration and extraction from the seawater matrix. Ammonium acetate was used to raise the pH of the 12 mL sub-samples (off-line) to pH 6.4 ± 0.2 prior to loading onto the chelating resin. The extracted metals were eluted using 1.0 M Q-HNO3 and determined using ICP-MS. The method was verified through the analysis of certified reference material (NASS-5) and the SAFe inter-comparison samples (S1 and D2), the results of which are in good agreement with the certified and reported consensus values. We also present vertical profiles of the eight metals taken from the Bermuda Atlantic Time Series (BATS) station collected during the GEOTRACES inter-comparison cruise in June 2008.  相似文献   

10.
Four algae reference materials, IAEA-391, 392, 393 and IAEA-140, prepared by the International Atomic Energy Agency for intercomparison under different preparation conditions were analyzed for 24 elements. Conventional neutron activation analysis (NAA) was used to determine Al, Ca, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Sb, V and Zn and epithermal NAA using BN and Cd as shielding material for I, Br, As, Ni, Mo and Cd. Inductively coupled plasma mass spectrometry (ICP-MS) as a complementary and comparative method was applied to determine Pb, Sn, Ni, Sr, Rb, As, Co, Cr, Cu, Mn, V, Mo and Zn. Two analytical quality control standard reference materials IAEA-V-10 (hay powder) and IAEA-331 (spinach) were analyzed simultaneously with real samples. The results agree quite well with each other and with the certified values.  相似文献   

11.
A flow injection (FI) on-line preconcentration procedure by using a nanometer-sized alumina packed micro-column coupled to inductively coupled plasma mass spectrometry (ICP-MS) was described for simultaneous determination of trace metals (V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb) in the environmental samples. The effects of pH value, sample flow rate, preconcentration time, and interfering ions on the preconcentration of analytes have been investigated. Under the optimized operating conditions, the adsorption capacity of the nanometer-sized alumina for V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb were found to be 11.7, 13.6, 15.7, 9.5, 12.2, 13.3, 17.1, 17.7 and 17.5 mg g−1, respectively. With 60 s preconcentration time and 60 s elution time, an enrichment factor of 5 and the sampling frequency of 15 h−1 were obtained. The proposed method has been applied to the determination of trace metals in environmental certified reference materials and natural water samples with satisfactory results.  相似文献   

12.
The possibility of using inductively coupled plasma atomic emission spectrometry (ICP-AES) to determine the elemental composition of archaeological bones elements was evaluated and discussed. The interferences of the major elements (Ca, P, K, Na, Al and Fe) on the microelements (Ba, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sr, Zn) were investigated and the appropriate analytical lines were selected. The role of different nebulizers (cross-flow, Babington and Meinhard) on detection limits were investigated. The applicability of the proposed procedure was demonstrated analyzing IAEA-SRM-H-5 (Animal bone); and authentic bone sample dating back to the 4th century BC. These results were compared to ETAAS and ICP-MS.  相似文献   

13.
An inductively coupled plasma mass spectrometry (ICP-MS) method for elemental impurities determination in components used for parenteral nutrition solutions is proposed. Solutions of amino acids (10% m/v), glucose (50% m/v) and lipids (20% m/v) were analyzed. Arsenic, Cd, Cu, Pb and Mo were determined by ICP-MS operated at standard mode, whilst pneumatic nebulization was used for introducing the sample solution into the ICP. Mercury was determined using cold vapor generation (CVG) coupled to ICP-MS. Chromium, Mn, Ni and V were determined by means of dynamic reaction cell-inductively coupled plasma mass spectrometry (DRC-ICP-MS), while ammonia was used as reaction gas. The operational conditions of each technique were optimized in order to achieve better sensitivity, precision and accuracy. The influence of the sample matrix, mainly carbon, on all investigated elements was evaluated. The use of DRC was effective to reduce interferences on Cr, Mn, Ni and V determination. The other investigated elements (As, Cd, Cu, Pb, Mo and Hg) were determined directly in the samples, which were properly diluted. Results obtained were in good agreement (between 96 and 103%) with certified values (certified reference materials of water were analyzed), at the same time as the relative standard deviation was lower than 5%. Sample throughput was relatively high (up to 30 samples of components used for parenteral nutrition solution could be analyzed per hour). In this way, the proposed method can be recommended for routine analysis.  相似文献   

14.
为实现蔬菜中多种元素的快速检测,利用单波长激发-能量色散X射线荧光光谱仪(MW-EDXRF),建立了蔬菜中As、Pb、Cd、Cr、Ni、Cu、Zn、Rb、Mn等元素的快速检测方法。对XRF的激发时间、载样量、样品压片等条件进行了优化,结果显示当累积激发时间达到600 s、载样量为2 g、样品压片15 Mpa保持60 s时,可以实现XRF最优检测性能。在最优条件下,As、Pb、Cd、Cr、Ni、Cu、Zn、Rb、Mn的检出限(LOD)分别为0.07 mg/kg、0.07 mg/kg、0.07 mg/kg、0.32 mg/kg、0.32mg/kg、1.2 mg/kg、0.4 mg/kg、0.08 mg/kg、0.3 mg/kg;对菠菜、葱、胡萝卜、豆角、番茄、姜、空心菜、莲藕、芹菜、蒜等蔬菜样品测定11次的相对标准偏差(RSD)在3%~10%,表明方法具有良好的精密度;测定5种蔬菜基体标准物质的回收率在93%~119%,与微波消解电感耦合等离子体质谱法(ICP-MS)测定结果对比的线性回归系数(R2)>0.99(Cu的R2=0.9838),表明方法具有良好的检测准确度。同时,该仪器仅有不到10 kg,不需要样品消解处理,检测时间在10 min左右,非常适合蔬菜多种重金属的现场快速筛查。  相似文献   

15.
Inductively coupled plasma-mass spectrometry (ICP-MS) and neutron activation analysis (NAA) were employed in the determination of heavy metal concentrations in water, plant and sediment samples to assess the extent of heavy metal pollution in a river system which is located within an industrial zone. Elemental concentrations of As, Pb, Hg, Cr, Cu, Cd, Ni and Zn were measured in the samples. Statistical analysis was performed on the data obtained to look for trends in the pollution pattern of these elements on the river system. The trend in concentrations of heavy metals pollution in water samples is in the order of Zn > Cu > Ni > Cr > As > Pb > Hg > Cd, whereas in plants the order is Zn > Cr > Cu > Pb > Ni > As > Hg > Cd and in sediments Zn > Cu > Pb > Ni > As > Hg.  相似文献   

16.
A method of determination of Co, Cu, Pb and Ni in nanogram quantities from aragonite is presented. Flotation and extraction of Co, Cu, Pb and Ni is suggested as methods for elimination matrix interferences of calcium. The method of flotation is performed by iron(III) hexamethylenedithiocarbamate, Fe(HMDTC)(3), as a colloid precipitate collector. The liquid-liquid extraction of Co, Cu, Pb and Ni is carried out by sodium diethyldithiocarbamate, NaDDTC, as complexing reagent into methylisobutyl ketone, MIBK. The electrothermal atomic absorption spectrometry (ETAAS) is used for determination of analytes. The detection limits of ETAAS followed by flotation are: 7.8 ng.g(-1) for Co, 17.1 ng.g(-1) for Cu, 7.2 ng.g(-1) for Pb and 9.0 mug.g(-1) for Ni. The detection limits of ETAAS followed by extraction are found to be: 12.0 ng.g(-1) for Co, 51.0 ng.g(-1) for Cu, 24.0 ng.g(-1) for Pb and 21.0 ng.g(-1) for Ni.  相似文献   

17.
Most of the analytical techniques used to quantify elements associated with solid samples suffer from high detection limits and cannot be used for trace elements in biomass samples, particularly when only 20 mg are available for analysis. Inductively coupled plasma mass spectrometry (ICP-MS) can achieve detection limits of parts-per-trillion with liquid sample introduction by solution nebulisation. This technique was therefore tested with two standard biomass reference materials: oriental tobacco leaves and cabbage leaves. Two preparations successfully used on coal standards were used to digest the solid samples: a total digestion method (wet ashing digestion) and a partial leaching (microwave extraction). The concentrations of up to seventeen elements (As, Ba, Be, Cd, Co, Cr, Cu, Ga, Mn, Mo, Ni, Pb, Sb, Se, Sn, V and Zn) were measured after the two preparations. The accuracy and sensitivity of the measurements improved when the dilution factor decreased from 5000 to 1000 and to 500. Since the proportion of mineral matter in biomass samples is small (5%), the microwave digestion extracted elements that are generally not completely extracted from coal samples (e.g. Sb). However, some trace element concentrations were below the limit of quantification after microwave extraction, even with a reduced dilution factor (As, Se and Mo) and could not be quantified. A fuel oil was also digested. The trace element concentrations were very low (between 28 and 0.1 microgram g(-1)) but acceptable results were obtained by applying a dilution factor of 100. Only six elements in the fuel oil (As, Ba, Co, Ni, Se and V) had certified or indicated values. Factors affecting the accuracy and sensitivity of the analyses are discussed. The reproducibility of analysis of the tobacco leaf standard was checked over a period of nine months by both digestion methods. The wet ashing method gave acceptable reproducibility for Ba, Cd, Co, Cu, Ga, Mn, Mo, Ni, Pb, V and Zn but poor precision for Cr, Se and Sn and showed evidence of residual chloride interference for As. The microwave extraction gave good reproducibility for As, Ba, Cd, Co, Cr, Cu, Mo, Ni and Zn but poor precision for Se and low recoveries for Ga, Mn, Sn and V. In spite of the small quantities of material analysed, it proved possible to determine the trace elements at levels down to 0.1 microgram g(-1) in the reference materials.  相似文献   

18.
Robache A  Mathé F  Galloo JC  Guillermo R 《The Analyst》2000,125(10):1855-1859
A method was developed for the elemental analysis of size segregated particles ranging from 0.03 to 10 microns. Sampling and analysis problems are discussed in this paper. Particles were collected with a Dekati low-pressure cascade impactor. PTFE filters coated with oleic acid were used as substrate. Particles were microwave digested in closed vessels. The optimum digestion mixture was composed of HNO3 (1 mL), HF (50 microL) and H2O (1 mL). The optimal power setting and digestion time were studied in order to achieve an efficient digestion. A ca. 35 min microwave digestion cycle at a 650 W maximum power allowed complete digestion of the samples. Special emphasis was placed on the pressure in the closed vessels to avoid sample losses. Solution samples were analysed by inductively coupled plasma optical emission spectrometry using an ultrasonic nebuliser for 18 elements (Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, S, Sr, Ti, V, Zn). This procedure was tested with NIST Standard Reference Material 1648 Urban Particulate. Recoveries for certified elements ranged from 95 to 105% except for Al (90%). The influence of cascade impactor materials was investigated with 44 field samples. Strong artefacts due to contamination were shown for analysis at environmental concentrations of Al, Cr, Mn and Ni.  相似文献   

19.
A method is described for the determination of Mn, Cu, Co, Zn, Cd, Pb and U in samples of manganese nodules. After dissolution of the sample in concentrated hydrochloric acid, the elements are adsorbed on a column of the strongly basic anion-exchange resin Dowex 1 from a medium consisting of 50 % (v/v) hexone, 40 % (v/v) isopropanol and 10 % (v/v) 12 M hydrochloric acid. After removal of iron by washing the resin bed with a mixture of the same composition, 6 M hydrochloric acid is passed through the column to elute Mn, Cu, Co, and Pb, and then 1 M hydrochloric acid and 2 M nitric acid to elute Zn, Cd and U. In the eluates the elements are determined by atomic-absorption spectrometry except for uranium which is determined by fluorimetry. The method was used successfully for the determination of mg and p.p.m. quantities of Mn, Cu, Co, Zn, Cd, Pb and U in 17 samples of manganese nodules from the Pacific Ocean.  相似文献   

20.
Kara D  Fisher A  Hill SJ 《The Analyst》2005,130(11):1518-1523
An on-line flow injection method for the direct determination of trace elements in environmental samples is described. A mini-column packed with 2,6-diacetylpyridine functionalized Amberlite XAD-4 was used to preconcentrate and separate 8 trace metals (Cd, Co, Cu, Mn, Ni, Pb, U and Zn) from water and extracts from solid samples. The metals were eluted with 0.1 M HNO(3) directly to the detection system (either inductively coupled plasma-mass spectrometry (ICP-MS) or flame atomic absorption spectrometry (FAAS)). As well as demonstrating that the resin could be used to preconcentrate ultra-trace analytes from natural waters, it was also shown to work well at a pH of 5.5. Therefore, after treatment of sample digests with sodium fluoride, samples that contain extremely large concentrations of iron may be analysed for trace analytes without the excess iron overloading the capacity of the resin. To this end, the analytes Cd, Co, Cu and Ni were preconcentrated from acid extracts of certified soil/sediment samples and then eluted with nitric acid to be determined on-line. Limits of detection (3sigma) of Cd = 0.33 microg l(-1), Co = 0.094 microg l(-1), Cu = 0.34 microg l(-1), Mn = 0.32 microg l(-1), Ni = 0.30 microg l(-1), Pb = 0.43 microg l(-1), U = 0.067 microg l(-1) and Zn = 0.20 microg l(-1) for the FI-ICP-MS system and Cd = 22 microg l(-1), Co = 60 microg l(-1), Cu = 10 microg l(-1) and Ni = 4.8 microg l(-1) for the FI-FAAS system were obtained. Analysis of certified reference materials showed good agreement with the certified values using the two methods.  相似文献   