首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Oms MT  Cerdà A  Cerdà V 《Talanta》2003,59(2):319-326
An automatic method for the determination of total nitrogen in wastewater by sequential injection analysis and mineralization with UV radiation has been developed. The method is based on the mineralization of the samples with sodium persulphate in basic medium under UV radiation. Small volumes of sample and reagents are firstly aspirated into a single channel and then propelled by flow reversal to the UV reactor and then to the detector. The organic and inorganic nitrogen compounds are oxidized to nitrate that is then measured at 226 nm. The sequential injection procedure has been optimized and the factors affecting the efficiency of the oxidation have been studied with a number of test substances with different chemical structures and properties. Solutions in the concentration range 1-56 g l−1 of nitrogen can be analyzed with the described procedure. The sample rate is of 30-40 samples h−1. The LOD is 0.6 mg l−1 N and the reproducibility is 1.8% (28 mg l−1 N). Organic carbon in the form of glucose was added to a number of test solutions to study the potential interference of organic matter.The method was compared with the Kjeldahl digestion method by analyzing 15 wastewater samples with both methods. The nitrate and nitrite content of the non-oxidized samples were subtracted from the corresponding nitrogen content determined after photo-oxidation and the value compared with the Kjeldahl nitrogen content.  相似文献   

2.
The UV/UV method developed for the measurement of specific wastewater pollution parameters (ammonium, Kjeldahl nitrogen, total phosphorus) is adapted to the determination of sugars in fruit juices and soft drinks. The procedure is based on the UV spectrophotometric detection of by-products of UV photodegradation of carbohydrates. Time of analysis is greatly reduced by using specific pH conditions and diluted samples.  相似文献   

3.
Measurement of total nitrogen by Kjeldahl analysis is the historical reference method for determination of the protein content of dairy products and is used for both calibration and validation of alternative methods for protein determination. Accurate evaluation of alternative methods is not possible if there is large uncertainty regarding the reference values. When Kjeldahl analysis is used to establish reference values, the performance of the Kjeldahl testing must be verified and within established expectations. Advice is given for Kjeldahl system optimization, evaluation of test results, and trouble-shooting. Techniques for successful Kjeldahl nitrogen analysis of dairy products other than milk are discussed.  相似文献   

4.
In the present paper a focused-microwave Kjeldahl digestion procedure without metal catalyst for nitrogen determination in bean samples was developed. Temperature at which the decomposition plateau occurs, mass of potassium sulphate and either volume of sulphuric acid or hydrogen peroxide were optimised. Results of the two-level full factorial design (24) based on an analysis of variance demonstrated that only the decomposition plateau temperature and the sulphuric acid volume were statistically significant. Optimal conditions for the digestion of bean samples were obtained by using Doehlert design. The modified digestion procedure of 0.25 g of bean samples has been performed in 27 min at optimised conditions. The accuracy of the developed procedure by the analysis of the two certified reference materials, peach leaves (NIST 1547) and apple leaves (NIST 1515). The t-test applied to the results revealed that they are in agreement (p > 0.05) with the certified values. The precision, expressed as relative standard deviation (R.S.D.) was of 0.96% for four successive Kjeldahl nitrogen determinations. In addition, interlaboratory exercises were performed with several bean samples in reference Brazilian food control laboratory.  相似文献   

5.
Five different TiNx coatings have been deposited on steel substrates by reactive magnetron sputtering. A quantitative analysis was carried out in two ways. The coatings were initially analysed by GDOS and after removing the coatings from the substrates and digesting the TiNx powder, nitrogen was quantified by the Kjeldahl technique and titanium by AAS. A comparison of the results shows that AAS and Kjeldahl results correlate very well, whereas GDOS results deviate from these two methods systematically.  相似文献   

6.
An on-line gas diffusion/dialyser unit has been designed and incorporated into the manifold of a flow injection system for the simultaneous determination of two different species in a single sample injected into the FIA system. A fast and reliable fully automated two-component flow injection procedure has been carried out where a single sample (50 l industrial effluent water) is injected into a carrier stream and simultaneously gas diffused and dialysed in a single on-line gas diffusion/dialyser unit for the determination of ammonia and chloride, respectively. The results obtained for the ammoniacal nitrogen and chloride in industrial effluent water compared well with data obtained by standard methods. The relative standard deviation for industrial effluent water samples with concentrations of ammoniacal nitrogen in the range between 0.050 and 1 g/l and chloride from 0.127 to 2.531 g/l have been better than 1.0% for ammoniacal nitrogen and 0.5% for chloride, respectively. The proposed system could be attractive for routine analyses of industrial effluent water.  相似文献   

7.
Marcó A  Rubio R  Compañó R  Casals I 《Talanta》2002,57(5):1019-1026
The features of the Dumas combustion method (CM) and those of the Kjeldahl method (KM) were compared as they apply to total nitrogen determination in animal feed. Both methods achieved similar repeatability (S.D., 0.11-0.38 from Kjeldahl and 0.15-0.36 from combustion) and similar intra-laboratory reproducibility (S.D., 0.11-0.39 from Kjeldahl and 0.15-0.37 from combustion). R.S.D. is always below 2%. These results show that the CM is suitable for the analysis of protein content in animal feed (5-75% protein content). The CM is recommended owing to its shorter analysis time, its cost and its environmental suitability.  相似文献   

8.
《合成通讯》2013,43(18):2797-2802
ABSTRACT

A new quaternary ammonium bromide salt has been used for the first time in phase transfer catalysis (PTC) reactions such as oxidation of alcohols to carbonyl compounds, alkylation and esterification reactions. Improved yields and reduced reaction times have been achieved by this procedure.

  相似文献   

9.
A method is described for the determination of hydrogen, oxygen and nitrogen in uranium monocarbide. Hydrogen and oxygen are determined by the classical or modified “Platinum flux” method at 2000° with a coefficient of variation of 10%. Nitrogen is determined at 2000° by the modification of the “Platinum flux” technique. The results obtained are in agreement with those found by Kjeldahl analysis. The coefficient of variation is about 10%. A procedure for the simultaneous determination of the 3 gases is given.  相似文献   

10.
A flow-batch system allowing in-line individual sample matrix matching is proposed for analysis of sample lots with high variability in acidity. The feasibility of the approach is demonstrated in the spectrophotometric determination of total nitrogen in Kjeldahl digests, using a column with a slightly soluble reagent (AgCl). The solutions are sequentially injected by means of an 8-port selecting valve and processed in a mixing chamber that is also used as a monitoring unit. The system yields reproducible results (r.s.d. usually < 2.5%) and the sampling rate is 14 samples/h. The analytical curve is linear within 1.00 and 6.00% N (dry basis), and the regression coefficient is > 0.999 (n = 6). Results are in agreement with certified values of standard reference materials and with results obtained by conductometry.  相似文献   

11.
The optimization of a rather complex wet chemical analysis method, such as the measurement of Kjeldahl nitrogen or total phosphorus with the Technicon AutoAnalyzer, is extremely tedious when purely empirical approaches are used. A mathematical model of the different stages of the measuring method (digestion, neutralization and color reaction) is described. The system can then be optimized for maximum measuring sensitivity. Optimization is done by solving numerically the non-linear optimization problem with constraints. The starting values for the optimization algorithm were found by varying these values systematically within the tolerated range, with checks that none of the constraints were violated. The theoretical results predict an increase in sensitivity by a factor of 15 compared to the method used previously. In practice, the sensitivity was increased by a factor of 10 for the total phosphorus method. For the simultaneous low-level determinations of Kjeldahl nitrogen and total phosphorus some problems of stability remain.  相似文献   

12.
Merkle EJ  Graab JW  Davis WF 《Talanta》1974,21(12):1317-1320
Results obtained for the determination of nitrogen in two tantalum alloys and six niobium alloys by modified Kjeldahl and Leco TC-30 nitrogen—oxygen determinator are compared. In the 5–25 ppm range, for tantalum alloys, the relative standard deviation was 3–9% by the Kjeldahl procedure and 9–11% by the instrumental technique. In the range 30–80 ppm, for niobium alloys, the relative standard deviation was 2–8% by the Kjeldahl procedure and 5–7% by the instrumental technique.  相似文献   

13.
凯氏定氮装置的改进   总被引:1,自引:0,他引:1  
针对传统凯氏定氮装置存在的问题,设计了一种新型的定氮装置,尤其对氮气球、通气开关、球型冷凝管进行了重新设计.实践证明,改进的凯氏定氮装置完全可以满足常量定氮分析.  相似文献   

14.
The objective of this collaborative study was to determine interlaboratory performance statistics for a modified and optimized version of AOAC Method 920.123 for the determination of the total nitrogen content of hard, semihard, and processed cheese by Kjeldahl analysis. Details included addressing the issues of material homogeneity, test portion size (1 g), quantitative transfer (weighing on to filter paper), ensuring system suitability (nitrogen recoveries), and using AOAC Method 991.20 as the basis for nitrogen analysis. Fifteen laboratories tested 18 pairs of blind duplicate cheese materials with a crude protein content between 18 and 36%. Materials represented hard, semihard, and processed commercial cheeses with a wide range of composition. Statistical performance parameters expressed as crude protein (nitrogen x 6.38), g/100 g, with invalid and outlier data removed were mean = 26.461, repeatability standard deviation (Sr) 0.111, reproducibility standard deviation (S(R)) = 0.153, repeatability relative standard deviation (RSDr) = 0.42%, reproducibility relative standard deviation (RSDR) = 0.58%, repeatability (r) = 0.312, and reproducibility (R) = 0.428. The interlaboratory study results were acceptable and comparable to those for the milk Kjeldahl nitrogen method on a relative nitrogen basis. The Study Directors recommend that this modified method for the determination of total nitrogen in hard, semihard, and processed cheese by Kjeldahl analysis be adopted First Action as an improved method to replace Method 920.123.  相似文献   

15.
通过甲醛法、四苯硼钠沉淀法以及磷酸铵镁沉淀法(MAP)测定模拟体系中铵离子含量,分析比较确定了聚马来酸酐(PMA)与氨气反应产物中铵离子的测定方法,即利用磷酸氢二钠和氯化镁结合铵离子形成磷酸铵镁沉淀,并通过凯式定氮法确定体系中铵离子含量。结果表明,pH值为9.0时,铵离子测定得到了较好的结果,测定平均值为5.50mmol/g,测定平均误差为2.1%,方法有很好的精密度和准确度,能够满足实际测试要求。  相似文献   

16.
An automated system for hydride generation - cryotrapping- gas chromatography - atomic absorption spectrometry with the multiatomizer is described. Arsines are preconcentrated and separated in a Chromosorb filled U-tube. An automated cryotrapping unit, employing nitrogen gas formed upon heating in the detection phase for the displacement of the cooling liquid nitrogen, has been developed. The conditions for separation of arsines in a Chromosorb filled U-tube have been optimized. A complete separation of signals from arsine, methylarsine, dimethylarsine, and trimethylarsine has been achieved within a 60 s reading window. The limits of detection for methylated arsenicals tested were 4 ng l(-1). Selective hydride generation is applied for the oxidation state specific speciation analysis of inorganic and methylated arsenicals. The arsines are generated either exclusively from trivalent or from both tri- and pentavalent inorganic and methylated arsenicals depending on the presence of L-cysteine as a prereductant and/or reaction modifier. A TRIS buffer reaction medium is proposed to overcome narrow optimum concentration range observed for the L-cysteine modified reaction in HCl medium. The system provides uniform peak area sensitivity for all As species. Consequently, the calibration with a single form of As is possible. This method permits a high-throughput speciation analysis of metabolites of inorganic arsenic in relatively complex biological matrices such as cell culture systems without sample pretreatment, thus preserving the distribution of tri- and pentavalent species.  相似文献   

17.
The surface modification of cellulose fabric with chitosan was achieved through an oxidation of the fabric with KIO4 followed by reductive ammination with chitosan. The chitosan content in the fabric determined by Kjeldahl nitrogen analysis technique was 1.69%. The scanning electron micrograph revealed submicron particles of chitosan attached on the fabric surface. Dyeing of the modified fabrics with mono-chloro-triazine and vinyl sulfone anionic reactive dyes, showed vastly improved exhaustion and color yield (K/S) indicating that this method of surface modification is effective for changing surface activity of the fabric. The enhancement of the dye uptake brought about an improved dyeing process in which the dye and salt used could be reduced by half and 14%, respectively. A Significant drop in burst strength upon the oxidation but no discernable adverse color fastness property was observed for the chitosan-modified fabric.  相似文献   

18.
19.
A flow-batch system allowing in-line individual sample matrix matching is proposed for analysis of sample lots with high variability in acidity. The feasibility of the approach is demonstrated in the spectrophotometric determination of total nitrogen in Kjeldahl digests, using a column with a slightly soluble reagent (AgCl). The solutions are sequentially injected by means of an 8-port selecting valve and processed in a mixing chamber that is also used as a monitoring unit. The system yields reproducible results (r.s.d. usually < 2.5%) and the sampling rate is 14 samples/h. The analytical curve is linear within 1.00 and 6.00% N (dry basis), and the regression coefficient is > 0.999 (n = 6). Results are in agreement with certified values of standard reference materials and with results obtained by conductometry. Received: 5 April 2000 / Revised: 6 June 2000 / Accepted: 13 June 2000  相似文献   

20.
An ion chromatographic (IC) method was developed for the determination of cyanate in gold cyanidation samples containing large concentrations of metallo-cyanide complexes. The analysis was performed on a Waters HC IC-Pak A anion-exchange column with an anthranilic acid eluent, with detection achieved using indirect UV at 355 nm. Two procedures were developed for removal of the metallo-cyanide complexes prior to the IC analysis. The first was a manual off-line method which used solid-phase extraction cartridges containing a strong anion-exchange resin to trap the complexes and to then enable determination of cyanate without interference. In the second approach, an automated on-line method was developed which used an anion-exchange guard column to trap the complexes and a column switching valve to allow backflushing of the cyanate from the guard column. This enabled the total analysis to be performed in a time of 10–14 min, depending on the sample composition. Finally, a comparison of results obtained by the standard Kjeldahl nitrogen method for cyanate and the IC method revealed an interference in the Kjeldahl method for samples containing large concentrations of Cu(I)-cyanide complexes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号