首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
This study reports a detailed analysis of an electrode material containing poly(phenolphthalein), carbon nanotubes and gold nanoparticles which shows superior catalytic effect towards to hydrazine oxidation in Britton–Robinson buffer (pH 10.0). Glassy carbon electrode was modified by electropolymerization of phenolphthalein (PP) monomer (poly(PP)/GCE) and the multiwalled carbon nanotubes (MWCNTs) was dropped on the surface. This modified surface was electrodeposited with gold nanoparticles (AuNPs/CNT/poly(PP)/GCE). The fabricated electrode was analysed the determination of hydrazine using cyclic voltammetry, linear sweep voltammetry and amperometry. The peak potential of hydrazine oxidation on bare GCE, poly(PP)/GCE, CNT/GCE, CNT/poly(PP)/GCE, and AuNPs/CNT/poly(PP)/GCE were observed at 596 mV, 342 mV, 320 mV, 313 mV, and 27 mV, respectively. A shift in the overpotential to more negative direction and an enhancement in the peak current indicated that the AuNPs/CNT/poly(PP)/GC electrode presented an efficient electrocatalytic activity toward oxidation of hydrazine. Modified electrodes were characterized with High-resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). Amperometric current responses in the low hydrazine concentration range of 0.25–13 µM at the AuNPs/CNT/poly(PP)/GCE. The limit of detection (LOD) value was obtained to be 0.083 µM. A modified electrode was applied to naturel samples for hydrazine determination.  相似文献   

2.
4-(Dimethylamino)pyridine capped gold nanoparticles (DMAP-AuNPs) were synthesized in aqueous medium and then immobilized on 1,6-hexanedithiol (HDT) modified Au electrode for the selective determination of 3,4-dihydroxyphenylacetic acid (DOPAC) in the presence of ascorbic acid (AA). The synthesized DMAP-AuNPs were characterized by UV-visible spectroscopy and high resolution-transmission electron microscopy (HR-TEM). The HR-TEM images showed that the nanoparticles are spherical in shape with a diameter of ~12 nm. The DMAP-AuNPs immobilized on HDT modified electrode was characterized by cyclic voltammetry and impedance spectroscopy. Impedance spectra show that the electron transfer reaction was more facile at the AuNPs modified electrode when compared to bare and HDT modified Au electrodes. The application of DMAP-AuNPs modified electrode was demonstrated by selective determination of DOPAC in the presence of high concentration of AA at pH 4. Using amperometry method, 40 nM detection of each AA and DOPAC was achieved. The current response was increased linearly with increasing AA and DOPAC in the concentration range of 40×10(-9) to 10×10(-5) M and a detection limit was found to be 5.6×10(-10) M and 3.7×10(-10) M (S/N=3) for AA and DOPAC, respectively. The present modified electrode was also successfully used for the determination of 40 nM DOPAC in the presence of 2500-fold excess of common interferents such as Na(+), Mg(2+), Cu(2+), Ca(2+), NH(4)(+) urea and glucose.  相似文献   

3.
We report here the fabrication of a flower-like self-assembly of gold nanoparticles (AuNPs) on a glassy carbon electrode (GCE) as a highly sensitive platform for ultratrace Cr(VI) detection. Two AuNP layers are used in the current approach, in which the first is electroplated on the GCE surface as anchors for binding to an overcoated thiol sol–gel film derived from 3-mercaptopropyltrimethoxysilane (MPTS). The second AuNP layer is then self-assembled on the surface of the sol–gel film, forming flower-like gold nanoelectrodes enlarging the electrode surface. When functionalized by a thiol pyridinium, the fabricated electrode displays a well-defined peak for selective Cr(VI) reduction with an unusually large, linear concentration range of 10–1200 ng L−1 and a low detection limit of 2.9 ng L−1. In comparison to previous approaches using MPTS and AuNPs on Au electrodes, the current work expands the use of AuNPs to the GCE. Subsequent functionalization of the secondary AuNPs by a thiol pyridinium and adsorption/preconcentration of Cr(VI) lead to the unusually large detection range and high sensitivity. The stepwise preparation of the electrode has been characterized by electrochemical impedance spectroscopy (EIS), scanning electronic microscopy (SEM), and IR. The newly designed electrode exhibits good stability, and has been successfully employed to measure chromium in a pre-treated blood sample. The method demonstrates acceptable fabrication reproducibility and accuracy.  相似文献   

4.
Nanometer sized materials have been shown to possess excellent chemical and electrochemical catalytic properties. In this work, a gold nanoparticle (AuNP) modified indium tin oxide (ITO) electrode was employed for investigating its electro-catalytic property. AuNP was deposited on the 3-aminopropyltriethoxysilane (APTES) modified ITO electrode by self-assembly, and was characterized by scanning electron microscopy and cyclic voltammetry. Although the electrochemical reaction of dopamine was very sluggish on the ITO/APTES electrode, it was significantly enhanced after AuNP deposition. The cyclic voltammogram exhibited apparent dependence on the surface coverage of 11 nm AuNPs, which could be rationalized by different modes of mass diffusion. Among the different sizes of AuNP investigated, the lowest anodic peak potential was observed on 11 nm AuNP. However, the potential was still about 50 mV more positive than that obtained on a bulk gold electrode of similar geometry. It is therefore concluded that there is no nanometer size effect of AuNP modified ITO on the electrochemistry of dopamine.  相似文献   

5.
《Electroanalysis》2017,29(5):1222-1231
A microbial sensor, namely carbon paste electrode (CPE) modified with Citrobacter freundii (Cf–CPE) has been developed for the detection of hexavalent (Cr(VI)) and trivalent (Cr(III)) chromium present in aqueous samples using voltammetry, an electroanalytical technique. The biosensor developed, demonstrated about a twofold higher performance as compared to the bare CPE for the chosen ions. Using cyclic voltammetry and by employing the fabricated Cf–CPE, the lowest limit of detection (LLOD) of 1x10−4 M and 5x10−4 M for Cr(VI) and Cr(III) ions respectively could be achieved. By adopting the Differential Pulse Cathodic Stripping Voltammetric technique, the LLOD could be further improved to 1x10−9 M and 1x10−7 M for Cr(VI) and Cr(III) ions respectively using the biomodified electrodes. The reactions occurring at the electrode surface‐chromium solution interface and the mechanisms of biosorption of chromium species onto the biosensor are discussed. The stability and utility of the developed biosensor for the analysis of Cr(VI) and Cr(III) ions in chromite mine water samples has been evaluated.  相似文献   

6.
This paper reported the enzymatic deposition of Au nanoparticles (AuNPs) on the designed 3-mercapto-propionic acid/glucose oxidase/chitosan (MPA/GOD/Chit) modified glassy carbon electrode and its application in glucose detection. Chit served as GOD immobilization matrix and interacted with MPA through electrostatic attraction. AuNPs, without nano-seeds presented on the electrode surface, was produced through the glucose oxidase catalyzed oxidation of glucose. The mechanism of production of AuNPs was confirmed to be that enzymatic reaction products H(2)O(2) in the solution reduce gold complex to AuNPs. The characterizations of the electrode modified after each assembly step was investigated by cyclic voltammetry and electrochemical impedance spectroscopy. Scanning electron microscopy showed the average particle size of the AuNPs is 40nm with a narrow particle size distribution. The content of AuNPs on the electrode surfaces was measured by differential pulse stripping voltammetry. The electrochemical signals on voltammogram showed a linear increase with the glucose concentration in the range of 0.010-0.12mM with a detection limit of 4μM. This provided a method to the determination of glucose.  相似文献   

7.
We report herein a simple device for rapid biosensing consisting of a single microfluidic channel made from poly(dimethylsiloxane) (PDMS) coupled to an injector, and incorporating a biocatalytic sensing electrode, reference and counter electrodes. The sensing electrode was a gold wire coated with 5 nm glutathione-decorated gold nanoparticles (AuNPs). Sensitive detection of H2O2 based on direct bioelectrocatalysis by horseradish peroxidase (HRP) was used for evaluation. HRP was covalently linked the glutathione–AuNPs. This electrode presented quasi-reversible cyclic voltammetry peaks at ?0.01 V vs. Ag/AgCl at pH 6.5 for the HRP heme FeIII/FeII couple. Direct electrochemical activity of HRP was used to detect H2O2 at high sensitivity with a detection limit of 5 nM in an unmediated system.  相似文献   

8.
The electrochemical behavior of different size gold nanoparticles (AuNPs) was investigated. AuNPs with 2, 5, 10, 15, 20 and 50 nm diameters were immobilized onto a screen printed carbon electrode surface by physical adsorption. The impedimetric response was measured for different diameter AuNPs at a fixed value of their surface area, at the same content of gold (Au) and at the same concentration. In a further experiment, the impedimetric response toward AuNP concentration was measured for each diameter. Impedimetric results were compared with results obtained for the detection of Au by stripping voltammetry. Additionally, variability of active surface area and roughness of different electrodes before and after immobilization of AuNPs were carefully evaluated by means of cyclic voltammetry and laser scanning microscopy. Electrochemical impedance spectroscopy (EIS) is a sensitive technique capable of differentiating the signal generated by AuNPs of different sizes, thus providing useful information for the employment of AuNPs in electrochemical biosensors.  相似文献   

9.
A novel enzyme-free electrochemical sensor for H2O2 was fabricated by modifying an indium tin oxide (ITO) support with (3-aminopropyl) trimethoxysilane to yield an interface for the assembly of colloidal gold. Gold nanoparticles (AuNPs) were then immobilized on the substrate via self-assembly. Atomic force microscopy showed the presence of a monolayer of well-dispersed AuNPs with an average size of ~4 nm. The electrochemical behavior of the resultant AuNP/ITO-modified electrode and its response to hydrogen peroxide were studied by cyclic voltammetry. This non-enzymatic and mediator-free electrode exhibits a linear response in the range from 3.0?×?10?5 M to 1.0?×?10?3 M (M?=?mol?·?L?1) with a correlation coefficient of 0.999. The limit of detection is as low as 10 nM (for S/N?=?3). The sensor is stable, gives well reproducible results, and is deemed to represent a promising tool for electrochemical sensing.
Figure
AuNPs/ITO modified electrode prepared by self-assembly method exhibit good electrocatalytic activity towards enzyme-free detection H2O2. The linear range of typical electrode is between 3.0?×?10?5 M and 1.0?×?10?3 M with a correlation coefficient of 0.999 and the limit detection is down to 1.0?×?10?8 M.  相似文献   

10.
An electrochemical sensor for dopamine was developed by electrodepositing poly(propylene imine) (PPI) dendrimer and gold nanoparticles (AuNPs) onto a glassy carbon electrode (GCE). Electrochemical characterisation of the sensor was carried out by cyclic voltammetry and electrochemical impedance spectroscopy in ferri/ferrocyanide electrolyte. The nanocomposite electrode (GCE-PPI-AuNPs) showed improved electroactive surface area and electrochemical response over bare GCE. The sensor recorded a detection limit of 0.16 μM over a concentration range of 0.1 μM to 125 μM. The sensor was applied for dopamine detection in human serum samples and in the presence of interfering substances such as ascorbic acid and epinephrine.  相似文献   

11.
《Analytical letters》2012,45(10):1184-1196
The electrochemical detection of As(III) was investigated on the novel citrate stabilized gold nanoparticle modified glassy carbon electrode (AuNPs/GCE) in 1 M HCl by square wave anodic stripping voltammetry. AuNPs/GCE was prepared by simply casting citrate stabilized gold nanoparticles onto the well-polished glassy carbon electrode. Gold modification was evaluated by cyclic voltammetry, while transmission electron microscopy and UV-vis Spectroscopy revealed the size and distribution of gold nanoparticles. Anodic stripping voltammetry was performed with the modified electrode in As(III) solution. Electrochemical experiments proved that AuNPS/GCE exhibited good performance for As(III) analysis, the linear range were obtained between 0.05 and 1 ppb for trace level of As(III) as well as 1 to 15 ppb, with a limit of detection of 0.025 ppb. In terms of reproducibility, the precision of the aforementioned method in %RSD was calculated at 7.78% (n = 10), and the repeatability of the proposed method was calculated to be 1.59%. The application of the method to analyze As(III) in tap water was investigated.  相似文献   

12.
《Analytical letters》2012,45(7):1117-1131
A molecularly imprinted electrochemical sensor was fabricated based on a gold electrode modified by chitosan-multiwalled carbon nanotube composite (CS-MWCNTs) multilayer films and gold nanoparticles (AuNPs) for convenient and sensitive determination of oxytetracycline (OTC). The multilayer of CS-MWCNTs composites and AuNPs were used to augment electronic transmission and sensitivity. The molecularly imprinted polymers (MIPs) were synthesized using OTC as the template molecule and o-phenylenediamine (OPD) as the functional monomer. They were modified on a gold electrode by electropolymerization. The electrochemical behavior of OTC at the imprinted sensor was characterized by cyclic voltammetry (CV), scanning electron microscopy (SEM), and amperometry. The molecularly imprinted sensor showed high selectivity and excellent stability toward OTC. The linear range was from 3.0 × 10?8 to 8.0 × 10?5 mol/L, with a limit of detection (LOD) of 2.7 × 10?8 mol/L (S/N = 3). The developed sensor showed good recovery in spiked samples analysis.  相似文献   

13.
Pandey PC  Pandey AK 《The Analyst》2012,137(14):3306-3313
A nanocomposite of nickel hexacyanoferrate (NiHCF) was made with gold nanoparticles (AuNPs) of two different sizes (20 and 80 nm as AuNP(red) and AuNP(blue) respectively), synthesized via 3-glycidoxypropyltrimethoxysilane mediated reduction of 3-aminopropyltrimethoxysilane treated gold chloride and characterized by scanning electron microscopy and UV-VIS spectroscopy. The size of AuNPs was found to influence the two pairs of reversible voltammetric peaks of cation rich and cation deficient NiHCF. Such influence was identified from cyclic voltammetry of nanocomposite modified electrodes and applications during electrochemical sensing of two different analytes hydrazine and glutathione (GSH). Electrochemical sensing of hydrazine was based on cyclic voltammetry and differential pulse voltammetry (DPV) found as a function of sodium deficient NiHCF and was greatly amplified with increasing AuNPs nanogeometry. NiHCF alone is not an efficient electrode material for GSH analysis at the level required, however, the presence of AuNPs introduces size dependent sensitive and selective detection of GSH. GSH sensing based on linear sweep voltammetry (LSV) was found to be mediated by the potassium rich form of NiHCF redox couple in the presence of AuNPs. The results justified electrochemical detection of these analytes based on a mediated mechanism and support the role of AuNPs for facilitated electrochemical activity of NiHCF based systems as a function of nanogeometry.  相似文献   

14.
辣根过氧化酶(HRP)在Co/NH2/ITO离子注入电极上有一对良好的氧化还原峰,峰电位分别为Epc=-0.2 V,Epa=-0.01 V(vsAg/AgCl)。该修饰电极对H2O2具有催化作用,可以用作H2O2的生物传感器,峰电流与H2O2的浓度分别在1.0×10-10~2.0×10-8mol/L和2.0×10-8~1.0×10-7mol/L范围内呈线性关系,线性回归方程分别为Ip(mA)=2.2986+0.06632c(nmol/L)和Ip(mA)=3.5788+7.3053E-4c(nmol/L),相关系数分别为0.9972和0.9688。检出限为1.0×10-10mol/L。  相似文献   

15.
Gold nanoparticle modified indium tin oxide (ITO) film coated glass electrodes were prepared for the first time through direct electrochemical deposition from 0.5 M H2SO4 containing 0.1 mM HAuCl4. The resulting electrode surfaces were characterized with AFM. Cyclic voltammetry and linear sweep voltammetry (LSV) of arsenic(III) on the modified electrodes were performed. After optimization, a LOD of 5 +/- 0.2 ppb was obtained with 60 s deposition at -0.6 V (vs. SCE) in 1 M HNO3 using LSV.  相似文献   

16.
A novel H2O2 amperometric biosensor based on the electrodeposition of gold nanoparticles (AuNPs) and CdS quantum dots (CdS QDs) onto a carbon paste electrode (CPE) and immobilizing hemoglobin (Hb) with ionic liquid (IL), is presented in this article. The modification process of the electrode was monitored by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Due to synergistic effects of AuNPs, CdS QDs and IL, the biosensor exhibited high stability and good bioelectrocatalytic ability to H2O2 with a linear concentration range from 10 to 750 µM and a detection limit of 4.35 µM (S/N=3).  相似文献   

17.
Potential cycling in the range from -0.2 to +1.2 V is used for the electrodeposition of hydrous iridium oxide films onto a screen-printed electrode from a saturated solution of alkaline iridium(III) solution. The iridium oxide redox couple shows a stable and obvious reversible redox, with the formal potential being pH dependent in the range 1-14. The properties, stability and electrochemical properties of iridium oxide films were investigated by cyclic voltammetry. A modified electrode showed excellent catalytic activity toward the oxidation of neurotransmitters (catecholamines) over a wide pH range (2-8). The electrocatalytic behavior is further exploited as a sensitive detection scheme for adrenaline and dopamine by hydrodynamic amperometry. Under the optimized conditions, the calibration curves are linear in the concentration range 0.1-70 and 0.1-15 microM for dopamine and adrenaline determination, respectively. The detection limit and sensitivity are 30 nM and 30 nA/microM for adrenaline and 15 nM and 80 nA/microM for dopamine. Finally, the analytical performance of the modified electrode was demonstrated for the elimination of interference by uric acid in catecholamines determination when present in a 1000-fold concentration excess.  相似文献   

18.
Poly brilliant cresyl blue (PBCB) and poly 5-amino-2-napthalenesulfonic (PANS) polymer composite modified electrode was fabricated by the electrochemical polymerization of brilliant cresyl blue and 5-amino-2-napthalenesulfonic acid. When compared polymer composite electrodes with PBCB and PANS electrode, it showed enhanced electrochemical property. The morphology of the resulting composite electrode was characterized by AFM, and the electrochemical properties of the modified electrode were characterized by cyclic voltammetry and amperometry. The composite electrode showed surface-confined and pH-dependent electrochemical property. The composite electrode exhibited high catalytic behavior toward the reduction of hydrogen peroxide at low overpotential. The detection limit and sensitivity of the electrode toward H2O2 detection was 5 μM and 1 μA/mM, respectively, and response time was less than 10 s for hydrogen peroxide.  相似文献   

19.
Ye D  Luo L  Ding Y  Chen Q  Liu X 《The Analyst》2011,136(21):4563-4569
A novel nitrite sensor was fabricated based on a graphene/polypyrrole/chitosan nanocomposite film modified glassy carbon electrode. The nanocomposite film was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and Raman spectroscopy. The electron transfer behaviour of the modified electrodes was investigated in [Fe(CN)(6)](3-)/(4-) redox probe using cyclic voltammetry and electrochemical impedance spectroscopy. Differential pulse voltammetry and amperometry were used to study the electrochemical properties of the proposed sensor. Under optimum conditions, the sensor exhibited good reproducibility and stability for nitrite determination. Linear response was obtained in the range of 0.5-722 μM with a detection limit of 0.1 μM (S/N = 3) for nitrite determination.  相似文献   

20.
The electrochemical analysis of tetracycline was investigated using nickel-implanted boron-doped diamond thin film electrode by cyclic voltammetry and amperometry with a flow injection system. Cyclic voltammetry was used to study the electrochemical oxidation of tetracycline. Comparison experiments were carried out using as-deposited boron-doped diamond thin film electrode (BDD). Nickel-implanted boron-doped diamond thin film electrode (Ni-DIA) provided well-resolved oxidation irreversible cyclic voltammograms. The current signals were higher than those obtained using the as-deposited BDD electrode. Results using nickel-implanted boron-doped diamond thin film electrode in flow injection system coupled with amperometric detection are presented. The optimum potential for tetracycline was 1.55 V versus Ag/AgCl. The linear range of 1.0 to 100 microM and the detection limit of 10 nM were obtained. In addition, the application for drug formulation was also investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号