1.
A poly(vinyl chloride)-based membrane of 2,9-dimethyl-4,11-diphenyl-1,5,8,12-tetraazacyclotetradeca-1,4,8,11-tetraene (DDTCT) with sodium tetraphenyl borate (STB) as an anion excluder and dibutyl phthalate (DBP), dibutyl butylphosphonate (DBBP), tris(2-ethylhexyl) phosphate (TEP) and tributyl phosphate (TBP) as plasticizing solvent mediators was prepared and investigated as a Ga(III)-selective electrode. The best performance was observed with the membrane having the ligand-PVC-DBP-STB composition 1:4:1:1, which worked well over a wide concentration range (1.45 × 10−6 to 0.1 mol L−1) with a Nernstian slope of 28.7 mV per decade of activity between pH 4.0 and 10.0. This electrode showed a fast response time of 12 s and was used over a period of 100 days with good reproducibility (s = 0.3 mV). The selectivity coefficients for monovalent, divalent and trivalent cations indicate excellent selectivity for Ga(III) ions over a large number of cations. Anions such as Cl and SO42− do not interfere and the electrode also works satisfactorily in partially water-alcohol medium. The practical utility of the membrane sensor has also been observed in solutions contaminated with detergents, i.e., cetyltrimethylammonium bromide and sodium dodecyl sulfate and used for the determination of gallium in nickel alloy, fly-ash and biological samples.  相似文献   

2.
Wang H  Zhang Z  Sun A  Liu D  Liu R 《Talanta》1996,43(12):2067-2072
A stopped-flow kinetic potentiometric method for the determination of aluminum is described, based on monitoring the reaction between aluminum and fluoride at pH 3.0 using fluoride ion-selective electrode. The initial rate of the reaction is proportional to the concentration of aluminum present in the solution. The method is simple and rapid and has been applied to the determination of aluminum in Chinese tea leaves after microwave digestion.  相似文献   

3.
Ion-selective electrode for the determination of metoclopramide   总被引:2,自引:0,他引:2  
S S Badawy  A F Shoukry  Y M Issa 《The Analyst》1986,111(12):1363-1365
  相似文献   

4.
Khalil S  El-Ries MA 《Talanta》2003,59(6):1259-1266
A new prenalterol (Pr) ion-selective PVC membrane electrode based on the ion-pair complex of Pr with sodium tetraphenylborate was prepared and its performance characteristics were studied. The electrode exhibited a linear response with a good Nernstian slope over a relatively wide range of concentration. The electrode whose membrane was made of 8.0% (w/w) of ion pair, 49.5% (w/w) of dioctyl phthalate (DOP) and 43.5% (w/w) of PVC showed characteristics higher than those obtained with the other ones, namely, slope of 56.3 mV per concentration decade, at 25 °C; usable concentration range 1.2×10−5–3.2×10−2 M prenalterol; response time ≤20 s. Up to 24 h continuous soaking, the calibration graph slope was constant at 56.0 mV per concentration decade, at 25 °C, then it decreased gradually as the time of soaking increases reaching 41 mV per decade after 11 days. The changes in pH did not affect the electrode performance within the range 2.2–7.5. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. The electrode showed very good selectivity for Pr with respect to a large number of inorganic and organic cations. The standard addition method and potentiometric titration were used to determine Pr in pure solutions and in pharmaceutical formulations. The relative standard deviations (R.S.D.) of the three methods used for the determination of prenalterol in pharmaceutical formulations were 0.8, 2.1 and 1.9% of the extrapolation, standard addition and potentiometric methods, respectively.  相似文献   

5.
A novel coated wire electrode (CWE) for Al(III) ions is described based on 2-(1H-benzo[d]imidazole-1-yl)-1-phenylethanoneoxime as a new ionophore in carbon-PVC composite. The sensor exhibits significantly enhanced selectivity toward Al3+ ions over the concentration range 4.3 × 10−7 to 5.0 × 10−2 M with a lower detection limit of 2.5 × 10−7 M and a Nernstian slope of 19.41 ± 0.52 mV decade−1 of aluminium activity. This sensor has a short response time of about 10 s and is reproducible and stable for at least forty-five days. This proposed CWE which is designed for the first time revealed good selectivity for Al(III) over a wide variety of other cations. The performance of the sensor is best in the pH range of 3.1-5.5 and it also works well in partially non-aqueous medium. Moreover, the assembly has been successfully used as an indicator electrode in the potentiometric titration of aluminium (III) against EDTA and also in determining Al(III) quantitatively in pharmaceutical and mineral water samples.  相似文献   

6.
A sensor is proposed for the direct potentiometric determination of dimethylbenzylammonium in acid and neutral aqueous solutions. The sensor membrane is made of a polymeric composition on the basis of polyvinylchloride containing an ion associate and a solvent as a plasticizer. Salts of the tetraphenylborate anion and its derivatives served as ionophores. Basic electroanalytical parameters of the developed potentiometric sensors are studied and the pH range of their possible application is determined. The developed sensor is used as a reference electrode in the potentiometric titration of dimethylbenzylammonium with tetraphenylborate anions.  相似文献   

7.
Khalil S 《The Analyst》1999,124(2):139-142
A coated wire trazodone-selective electrode based on incorporation of trazodone-tetraphenylborate ion pair in a poly(vinylchloride) coating membrane was constructed. The influences of membrane composition, temperature, pH of the test solution, and foreign ions on the electrode performance were investigated. The electrode showed a Nernstian response over a trazodone concentration range from 1.41 x 10(-5) to 0.89 x 10(-2) M, at 25 degrees C, and was found to be very selective, precise, and usable within the pH range 2.4-9.0. The standard electrode potentials, E degree, were determined at 20, 25, 30, 35, 40 and 45 degrees C and used to calculate the isothermal temperature coefficient (dE degree/dT) of the electrode. Temperatures higher than 45 degrees C seriously affected the electrode performance. The electrode was successfully used for potentiometric determination of trazodone hydrochloride both in pure solutions and in pharmaceutical preparations.  相似文献   

8.
In recent years perfluorinated alkylated substances (PFAS) have appeared as a new class of global pollutant. Besides being an industrially important group of compounds, PFAS are regarded as highly toxic and extraordinarily persistent chemicals that pervasively contaminate human blood and wildlife throughout the world. They are therefore regarded as PBT (persistent, bioaccumulative, and toxic) chemicals. Two comprehensive methods have been developed for determination of eleven of the most environmentally relevant PFAS (seven perfluoroalkylcarboxylates, two perfluoroalkylsulfonates, and two perfluoroctanesulfonamides) in aqueous samples. The compounds were isolated by liquid–liquid extraction (LLE) and solid-phase extraction (SPE), and identification and quantification of the target analytes were achieved by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS–MS). With LLE detection limits ranged from 0.26 to 0.62 ng L−1 for enrichment of 900-mL water samples; recovery of PFAS with a carbon chain longer than C7 was excellent (80–93%). With SPE, carboxylates with carbon chains <C10 could be extracted efficiently (70–98%) under acidic conditions, and PFOS and PFOSA could be extracted efficiently (81% and 96%, respectively) under basic conditions, resulting in MDLs between 0.25 and 0.64 ng L−1. The LLE method was applied successfully to Austrian wastewater effluent samples.  相似文献   

9.
Voltammetric method for the determination of non-steroidal anti-inflammatory drug mesalazine (5-ASA) is presented for the first time using boron-doped diamond electrode (BDDE). 5-ASA provides one well-developed SWV oxidation peak at about ?900 mV (vs. saturated silver/silver chloride reference electrode) on BDDE. Britton-Robinson buffer (pH 7.0) was chosen as an optimal supporting electrolyte for the determination of 5-ASA using square wave voltammetry (SWV). Parameters of SWV were developed and low limit of detection (7.0 × 10?7 mol L?1) was reached. In addition, relative standard deviation of repeated measurements (c 5-ASA = 5 × 10?5 mol L?1, RSDM = 2.7%) and relative standard deviation of repeated determinations (RSDD < 1.5%) were calculated and confirm obtained good results. Applicability of the proposed method was verified by an analysis of a pharmaceutical preparation and spiked human urine.  相似文献   

10.
A bare graphite-epoxy composite was evaluated as an electrode material in the determination of atenolol in natural water samples and pharmaceutical formulations for which the analyte was spiked. Using a DPV procedure, a linear response was observed in the 4.45–84.7?µmol?L?1 range with a LOD?=?2.23?µmol?L?1, without need of surface renewal between successive runs, and recoveries between 92.5 and 107.5% for pharmaceutical formulations. The results obtained from the proposed procedure agreed with HPLC results within a 95% confidence level. During the determination of atenolol in water samples, recoveries between 96.1 and 102.6% were found.  相似文献   

11.
Contaminants of emerging concern (CECs) such as per- and polyfluoroalkyl substances (PFAS) have attracted significant interest from researchers, policymakers, and water treatment facilities. This is because PFAS are highly persistent in the environment and tend to be bio-accumulative thus causing adverse effects on terrestrial and aquatic life. Therefore, there is a need for simpler and fast methods for the determination of PFAS in water sources. This work aims at the application of dispersive magnetic solid-phase extraction (DMSPE) for the enrichment of PFAS in various surface water samples. Magnetic Fe3O4@MIL-101 (Cr) was used as an adsorbent in MSPE. Fe3O4@MIL-101(Cr) was used for the first time for the preconcentration and extraction of PFAS in various river water samples. The concentrations of target analytes in water samples were determined using high performance liquid chromatography-diode array detector and ultra-high performance liquid chromatography-tandem mass spectrometry analysis. The combination of optimized DMSPE with HPLC-DAD and UHPLC-MS/MS provided wide linear range (1–5000 ng/L and 0.05–2000 ng/L, low limits of detection (0.3–0.66 ng/L and 0.011–0.04 ng/L) and limits of quantification (1.0–2.2 ng/L and 0.04–0.12 ng/L). Moreover, acceptable intraday and interday precision based on the relative standard deviation (RSD) lower than 5% were obtained. The developed method showed remarkable practicability for the analysis of ultra-trace PFAS in water samples.  相似文献   

12.
采用一种简单灵敏的方法开发了在多壁碳纳米管修饰的ZnCrFeO4糊电极(MWCNTs/ZnCrFeO4/CPE)表面测定苄丙酮香豆素的新型传感器.运用循环伏安法、差示脉冲伏安法、计时电流法和电化学阻抗谱考察了该化学修饰电极上苄丙酮香豆素的电化学性能.结果表明,MWCNTs/ZnCrFeO4/CPE电极对苄丙酮香豆素氧化表现出较高的电催化活性,在pH=4时,产生峰值氧化电流约0.97 vs Ag/AgCl参比电极.当苄丙酮香豆素浓度在0.02-920.0 μmol/L范围内,该峰电流与其呈线性关系,检测极限(3σ)为0.003 μmol/L.另外,运用差示脉冲伏安法测定了MWCNTs/ZnCrFeO/CPE电极上苄丙酮香豆素的催化反应速率常数和扩散系数.  相似文献   

13.
Rapid determination of caffeine in tea leaves   总被引:3,自引:0,他引:3  
For the purpose of efficient screening of low-caffeine tea shoots, a method for the rapid determination of caffeine was developed using high-performance liquid chromatography. Polyvinylpolypyrrolidone was packed in a pre-column and used to remove polyphenols from tea extracts on-line. The concentrations of caffeine extracted from powdered tea leaves at 50 degrees C during 1 day could be analyzed in 2-5 min intervals. The pre-column and the analytical column could be used for the analysis of more than 2000 samples.  相似文献   

14.
铝是人体必需微量元素之一 ,但含量过高有害于健康。本文研究了铝 (Ⅲ )与DBC 偶氮氯膦(DBC CPA) [1 ] 显色反应 ,在pH4 7HAc NaAc缓冲体系中 ,该试剂可与Al(Ⅲ )形成 1∶1紫蓝色络合物 ,最大吸收波长为 62 0nm ,ε62 0nm=1 38× 1 0 4 L·mol- 1 ·cm- 1 ,铝 (Ⅲ )在 0~ 35 μg/2 5mL范围内遵守比耳定律。本法用于雨水及碳酸钠中痕量铝的测定 ,结果满意。1 实验部分1 1 主要试剂铝标准溶液 :准确称取 1 75 82gKAl(SO4) 2 ·1 2H2 O ,溶于水后定容至 1 0 0mL ,得铝 1 0 0 0mg·mL- 1 储备液 ,移取适量储备液稀释后得铝 1 0…  相似文献   

15.
Raman B  Shinde VM 《Talanta》1989,36(4):469-472
A systematic study of extraction of zinc salicylate is reported. Optimum conditions for the extraction and determination of zinc are evaluated from a critical study of the effect of pH, sodium salicylate concentration and triphenylphosphine oxide concentration. The effect of foreign ions on the extraction is also discussed. The probable composition of the species has been deduced from the extraction data. The method has been used to separate zinc from cadmium and mercury in binary mixtures and for the determination of zinc in various pharmaceutical products.  相似文献   

16.
This work presents, for the first time, the voltammetric behavior of clonidine (CLO) drug and its determination, using an unmodified glassy carbon electrode (GCE). CLO exhibited only an irreversible oxidation process on the GCE, with peak potential at +0.85 V in pH 12 (vs Ag/AgCl). CLO oxidation process is pH-dependent and the electrochemical mechanisms on the GCE were proposed in acidic and basic medium. The determination of CLO was optimized in 0.1 mol L−1 phosphate buffer solution at pH 12.0 using differential pulse voltammetry (DPV), which provides a good linear range (0.65 to 106.00 μmol L−1) and low theoretical limit of detection (0.14 μmol L−1) for the quality control of this drug in pharmaceutical samples. In addition, stable responses of CLO at the GCE were obtained in the same day (RSD = 3.4 %; n = 5) and different days (RSD = 2.0 %; n = 3). Moreover, the determination of CLO in a pharmaceutical formulation using the proposed GCE-DPV method presented good accuracy, since the recovery was close to 100 % and the dosing result was in agreement with an official method (HPLC-UV). The proposed method demonstrates a good analytical performance for CLO determination in pharmaceutical samples, providing a faster, simpler and lower-cost alternative for quality control of CLO than other reported methods.  相似文献   

17.
毕树平  陈刚  刘剑  邹公伟  干宁 《化学学报》2000,58(5):494-499
利用吸附的方法在热解石墨电极上制得邻苯二酚紫(PCV)修饰电极。在NH~3.H~2O-NH~4Cl底液(pH8.5)中,该电极具有很好的电化学活性,其示差脉冲氧化峰电位为E~p~a=+80mV。对铝进行检测,只是峰电流降低,而峰电位不变,氧化峰电流的降低值与铝浓度在1×10^-^8-1×10^-^7mol.dm^-^3和1×10^-^7-1×10^-^6mol.dm^-^3范围内成正比,检测限为5×10^-^9mol.dm^-^3,标准偏差为5.0%(4×10^-^8mol.dm^-^3Al,n=8),对实际水样进行测定,结果令人满意。对其检测机理进行了研究后认为:(1)PCV修饰电极表面是PCV单分子层吸附,具有很好的电化学活性;(2)铝与PCV在电极表面形成一1:3的配合物,该配合物在修饰电极上本身没有电化学活性,仅覆盖住原有的PCV电活性点,从而使峰电流降低,而峰电位没有变化;因此,在有铝和无铝时,电极过程没有变化,都对应于PCV的电化学行为。我们用电化学方法、扫描电镜、X射线光电子能谱和X射线荧光光谱法对此进行了证明。  相似文献   

18.
Katsu T  Mori Y 《Talanta》1996,43(5):755-759
A salicylate-selective membrane electrode made with heptyl-4-trifluoroacetylbenzoate as a neutral carrier was successfully applied for the determination of salicylate in blood serum. This procedure is advantageous because the free concentration of the drug in serum can be determined without sample preparation. The free salicylate concentrations determined by the ion-selective electrode compared to those obtained by conventional colorimetry gave a linear correlation coefficient 0.997 in the salicylate concentration range 0.1-2.5 mM.  相似文献   

19.
Song-Min Huo  An-Ping Deng 《Talanta》2007,73(2):380-386
The development and validation of a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of pharmaceutical indomethacin in water samples was presented. The immunogen and coating antigen were prepared by covalently linking indomethacin to bovine serum albumin and ovalbumin by anhydride ester method. Two rabbits were immunized by standard immunization processes and the superior antibody was characterized in terms of sensitivity, specificity, precision, accuracy and stability. Under optimal experimental conditions, the standard curve was constructed in the concentration range of 0.01-10 ng/mL. For 10 consecutive standard curves run in 2 weeks, IC50 value (the concentration of analyte producing 50% of inhibition) were found within 0.10-0.25 ng/mL, and the detection limit (DL) at a signal-to-noise ratio of 3 (S/N = 3) was about 0.01 ng/mL. The antiserum recognized acemetacin, a precursor of indomethacin with 92.3% cross-reactivity, while the cross-reactivity values of antiserum with other tested compounds were very low. From the spiking experiments, the recoveries were found within 98-123%. The ELISA was applied for the determination of indomethacin in different water samples and the results were confirmed by conventional HPLC. The correlation coefficient of 0.988 was obtained, demonstrating a good correlation of ELISA with HPLC.  相似文献   

20.
Lead concentrations in water and sediment samples near a stationary metal emission source were determined using the lead ion-selective electrode. These results were then verified by use of atomic absorption spectrophotometric methods. Samples were collected at three strategic sites near a local lead company in Southeast Houston, Texas. Accumulated rain water and sediment (soil deep down core) were analyzed in order to estimate lead concentration as a function of depth. Data indicate that the level of lead concentrations in both surface water and water extracted from the sediments exceed the limits for drinking water as established by the Environmental Protection Agency. The lead concentrations of the soil samples were higher in most cases when compared with various soils in the United States. The highest concentrations of lead were found in surface water samples.  相似文献   