首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
The assessment of historical trends in atmospheric deposition of organic contaminants by using peat samples has been reported on several occasions because these samples represent an almost ideal medium for recording temporal changes in organic contaminant deposition rates. The determination of polycyclic aromatic hydrocarbons (PAHs) in peat samples is complicated due to the high content of organic matter in peat, which affects both extraction efficiency and analytical quality. A rapid and simple method is proposed for the determination of 10 US Environmental Protection Agency indicator PAHs in complex matrices such as peat. This article reviews and addresses the most relevant analytical methods for determining PAHs in peat. We discuss and critically evaluate three different extraction procedures, such as ultrasound-assisted solvent extraction (UASE), shaking and pressurized liquid extraction (PLE). Clean-up of extracts was performed by solid-phase extraction using silica cartridges. Detection of the selected PAHs was carried out by high-performance liquid chromatography coupled with fluorescence detection for determination. Optimization of the variables affecting extraction by the selected extraction techniques was conducted, concluding that the UASE extraction method using hexane:dichloromethane (80:20) as extractant was robust enough to determine the selected PAHs in peat samples with estimated quantification limits between 0.050 and 3.5 μg/kg depending on the PAH. UASE did not demand sophisticated equipment and long extraction times. PLE involved sophisticated equipment and showed important variations in the results. The method proposed was applied to the determination of PAHs in peat samples from Xistral Mountains (Galicia, Spain).  相似文献   

2.
Summary Due to the carcinogenity and ubiquity of polycyclic aromatic hydrocarbons in the environment they are of ongoing interest to analytical chemistry. In this study, a comparison of the classic Soxhlet extraction and, fluidized-bed extraction, has been conducted. The extraction of polycyclic aromatic hydrocarbons by this technique has been optimized considering as experimental variables the variation of the number of extraction cycles and the holding time after reaching the heating temperature by means of a surface response design. The significance of the operational parameters of the fluidized-bed extraction on the performance characteristics has been investigated. For the determination of the analytes a selective clean-up of the extracts followed by a fast gas chromatography method with mass spectrometric detection was used, resulting in low limits of detection (0.2 pg μL−1). The accuracy of the complete analytical method was established by extraction and analysis of reference materials.  相似文献   

3.
Pressurised microwave-assisted extraction was used to extract a complex mixture containing polycyclic aromatic hydrocarbons (PAHs), nitrated PAHs and heavy n-alkanes from a particularly refractory carbonaceous material resulting from the combustion in a diesel engine. A second-order central composite design was used to determine the optimal conditions of extraction in terms of time, temperature, volume and nature of extracting solvent from spiked diesel soots. To begin, methylene chloride, tetrahydrofuran and chloroform were tested for extracting the spiked diesel particulates; however, the nature of these solvents was not really an influential factor. Volume was the most influential factor and was kept at a medium level to enhance the extraction of heavy PAHs without introducing an important dilution factor. Temperature and time were not influential as main factors but interacted with the other factors. Finally, high temperature and duration associated with a medium volume of methylene chloride were better for the extractions. After this optimisation, five-ring and six-ring PAHs were nevertheless not satisfactorily desorbed. Other solvents were therefore tested. Only aromatic ones, and particularly heterocyclic aromatic solvents, managed to desorb the heaviest PAHs. Pyridine, with its both aromatic and its basic character, was the most successful solvent. Desorption was even complete with an addition of 17% of diethylamine into pyridine. So, using MAE, we succeeded in extracting quantitatively, from the spiked refractory diesel soot surface, two-ring to six-ring PAHs, heavy n-alkanes and short nitrated PAHs. However, heavy nitrated PAHs were better extracted with a small addition of acetic acid (1%) into pyridine instead of a basic cosolvent.  相似文献   

4.
Quantification of polycyclic aromatic hydrocarbons (PAHs) in smoked fish products often requires multiple clean-up steps to remove fat and other compounds that may interfere with the chemical analysis. We present a novel pressurized liquid extraction (PLE) method that integrates exhaustive extraction with fat retention in one single analytical step. The PLE parameters: type of fat retainer, flush volume, solvent composition, fat-to-fat retainer ratio (FFR), and the dimensions of the extraction cells were the most important factors for obtaining fat-free extracts with high recoveries of PAHs. A 100 mL extraction cell filled with 18 g activated silica gel, dichloromethane:hexane (15:85, v/v) as extraction solvent, FFR of 0.025 and 100% flush volume was the best analytical setup for integrated extraction and fat retention.The one-step procedure provided a more rapid and cost-efficient alternative with minimization of waste generation compared to the standard reference method that is based on a multi-step procedure. Furthermore, the analytical quality of the two methods are comparable, while the new integrated approach for extraction and cleanup is less prone to analytical errors (random and systematic) because of fewer analytical steps.  相似文献   

5.
Gas purge-microsyringe extraction (GP-MSE) is a rapid and exhaustive microextraction technique for volatile and semivolatile compounds. In this study, a theoretical system of GP-MSE was established by directly extracting and analyzing 16 kinds of polycyclic aromatic hydrocarbons (PAHs) from plant samples. On the basis of theoretical consideration, a full factorial experimental design was first used to evaluate the main effects and interactions of the experimental parameters affecting the extraction efficiency. Further experiments were carried out to determine the extraction kinetics and desorption temperature-dependent. The results indicated that three factors, namely desorption temperature (temperature of sample phase) Td, extraction time t, and gas flow rate u, had a significantly positive effect on the extraction efficiency of GP-MSE for PAHs. Extraction processes of PAHs in plant samples followed by first-order kinetics (relative coefficient R2 of simulation curves were 0.731–1.000, with an average of 0.958 and 4.06% relative standard deviation), and obviously depended on the desorption temperature. Furthermore, the effect of the matrix was determined from the difference in Eapp,d. Finally, satisfactory recoveries of 16 PAHs were obtained using optimal parameters. The study demonstrated that GP-MSE could provide a rapid and exhaustive means of direct extraction of PAHs from plant samples. The extraction kinetics were similar that of the inverse process of the desorption kinetics of the sample phase.  相似文献   

6.
Wang W  Meng B  Lu X  Liu Y  Tao S 《Analytica chimica acta》2007,602(2):211-222
The methods of simultaneous extraction of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) from soils using Soxhlet extraction, microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) were established, and the extraction efficiencies using the three methods were systemically compared from procedural blank, limits of detection and quantification, method recovery and reproducibility, method chromatogram and other factors. In addition, soils with different total organic carbon contents were used to test the extraction efficiencies of the three methods. The results showed that the values obtained in this study were comparable with the values reported by other studies. In some respects such as method recovery and reproducibility, there were no significant differences among the three methods for the extraction of PAHs and OCPs. In some respects such as procedural blank and limits of detection and quantification, there were significant differences among the three methods. Overall, ASE had the best extraction efficiency compared to MAE and Soxhlet extraction, and the extraction efficiencies of MAE and Soxhlet extraction were comparable to each other depending on the property such as TOC content of the studied soil. Considering other factors such as solvent consumption and extraction time, ASE and MAE are preferable to Soxhlet extraction.  相似文献   

7.
Pressurised liquid extraction (PLE) was applied to determine the atmospheric levels of 16 polycyclic aromatic hydrocarbons (PAHs) in the gas and particulate phases. The method involved high‐volume air sampling with quartz fibre filters (QFFs) and polyurethane foam (PUF) plugs and analytes were subsequently extracted from the samples by PLE, and determined with GC‐MS. We optimised the PLE conditions for the solvent, the number of cycles and extraction temperature. Recoveries were higher than 90% for most compounds. Method LODs and LOQs were between 0.001 and 0.02 ng/m3 and between 0.01 and 0.05 ng/m3. Air samples were taken from a site in the region of Tarragona in Catalonia, Spain, where one of the largest petrochemical complexes in southern Europe is located. The total concentration of PAHs were from 6.7 to 27.66 ng/m3, with predominant levels of PAHs appearing in the gas phase (48–81%), and an average level of benzo[a]pyrene, the most carcinogenic PAH, of 0.86 ng/m3.  相似文献   

8.
The application of sulfur microparticles as efficient adsorbents for the solid-phase extraction (SPE) and determination of trace amounts of 10 polycyclic aromatic hydrocarbons (PAHs) was investigated in sea water and wastewater samples using high performance liquid chromatography coupled with an ultraviolet detector (HPLC–UV). Parameters influencing the preconcentration of PAHs such as the amount of sulfur, solution flow rate and volume, elution solvent, type and concentration of organic modifier, and salt effect were examined. The results showed that at a flow rate of 10 mL min−1 for the sample solutions (100 mL), the PAHs could be adsorbed on the sulfur microparticles and then eluted by 2.0 mL of acetonitrile. For HPLC–UV analysis of extracted PAHs, the calibration curves were linear in the range of 0.05–80.0 μg L−1; the coefficients of determinations (r2) were between 0.9934 and 0.9995. The relative standard deviations (RSDs) for eight replicates at two concentration levels (0.5 and 4.0 μg L−1) of PAHs were lower than 7.3%, under optimized conditions. The limits of detection (LODs, <!-- no-mfc -->S/N<!-- /no-mfc --> = 3) of the proposed method for the studied PAHs were 0.007–0.048 μg L−1. The recoveries of spiked PAHs (0.5 and 4 μg L−1) in the wastewater and sea water samples ranged from 78% to 108%. The simplicity of experimental procedure, high extraction efficiency, short sample analysis, and using of low cost sorbent demonstrate the potential of this approach for routine trace PAH analysis in water and wastewater samples.  相似文献   

9.
Supercritical fluid extraction (SFE) was performed to extract complex mixtures of polycyclic aromatic hydrocarbons (PAHs), nitrated derivatives (nitroPAHs) and heavy n-alkanes from spiked soot particulates that resulted from the incomplete combustion of diesel oils. This polluted material, resulting from combustion in a light diesel engine and collected at high temperature inside the particulate filter placed just after the engine, was particularly resistant to conventional extraction techniques, such as soxhlet extraction, and had an extraction behaviour that differed markedly from certified reference materials (SRM 1650). A factorial experimental design was performed, simultaneously modelling the influence of four SFE experimental factors on the recovery yields, i.e.: the temperature and the pressure of the supercritical fluid, the nature and the percentage of the organic modifier added to CO2 (chloroform, tetrahydrofuran, methylene chloride), as a means to reach the optimal extraction yields for all the studied target pollutants. The results of modelling showed that the supercritical fluid pressure had to be kept at its maximum level (30 MPa) and the temperature had to be kept relatively low (75 °C). Under these operating conditions, adding 15% of methylene chloride to the CO2 permitted quantitative extraction of not only light PAHs and their nitrated derivatives, but also heavy n-alkanes from the spiked soots. However, heavy polyaromatics were not quantitatively extracted from the refractory carbonaceous solid surface. As such, original organic modifiers were tested, including pyridine, which, as a strong electron donor cosolvent (15% into CO2), was the most successful. The addition of diethylamine to pyridine, which enhanced the electron donor character of the cosolvent, even increased the extraction yields of the heaviest PAHs, leading to a quantitative extraction of all PAHs (more than 79%) from the diesel particulate matter, with detection limits ranging from 0.5 to 7.8 ng for 100 mg of spiked material. Concerning the nitrated PAHs, a small addition of acetic acid into pyridine, as cosolvents, gave the best results, leading to fair extraction yields (approximately 60%), with detection limits ranging from 18 to 420 ng.  相似文献   

10.
Magnetic polyimide poly(4,4′‐oxydiphenylene‐pyromellitimide) nanoparticles were successfully synthesized and developed for the solid‐phase extraction of polycyclic aromatic hydrocarbons in seawater samples. The aromatic rings of polyimide coating provided a good adsorption capacity (28.3–42.5 mg/g) for polycyclic aromatic hydrocarbons because of the π–π stacking interaction. The developed method was used as a simple, fast, and efficient extraction and preconcentration technique for the trace analysis of polycyclic aromatic hydrocarbons. The high chemical, physical and thermal stability, excellent reusability, and good magnetic properties are the merits of the sorbent. High preconcentration factors (41–63) were obtained. The sorbent was also characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, energy dispersive X‐ray spectrometry, transmission electron microscopy, and vibrating sample magnetometry. After optimizing several appropriate extraction parameters, the results indicated that the extraction recoveries of polycyclic aromatic hydrocarbons were in the range of 61.6–94.7%, with relative standard deviations between 2.9 and 5.4%, the calibration graph was linear in the concentration range of 1–100 μg/L (r > 0.9991) with limit of detection in the range of 0.15–0.19 μg/L (n = 3). Seawater samples were analyzed as real samples and good recoveries (68.5–99.5%) were obtained at different spiked values.  相似文献   

11.
Silicone rods with a diameter of 1 mm and 10 mm long were used to extract polycyclic aromatic hydrocarbons (PAHs) from water samples and for the rapid screening of highly contaminated waste material. The rods were placed in a 15 ml glass vial for the extraction of the analytes, which involved shaking (300 min−1) the sample for 3 h. After extraction the rods were placed into 250 μl inserts of 2 ml vials filled with 100 μl of an acetonitrile-water mixture (4:1) and desorption was performed with sonication for 10 min. Then the PAHs were determined using LC and fluorescence detection. Recoveries of the rod extraction ranged between 62 and 97% and the detection limits were between 0.1 and 1.2 ng l−1. These results are comparable with those of stir bar sorptive extraction (SBSE). Although the rods are reusable, their low price means they can be discarded if contaminated, eliminating the need for expensive cleaning. One disadvantage compared to SBSE is the longer extraction time needed to reach equilibrium.  相似文献   

12.
For the first time, plastic pellets, a low-cost and easy to reach industrial raw material, are reported as an efficient sorbent material for the laboratory extraction of polycyclic aromatic hydrocarbons (PAHs) from environmental waters. The proposed methodology, termed plastic pellets sorptive extraction (P2SE), consisted of a two-step procedure whereby target analytes were initially adsorbed onto the surface of three low-density polyethylene (LDPE) pellets and then desorbed using microliters of an organic solvent. Interphase mass transfer was greatly accelerated by means of vortex agitation. Organic extracts were analyzed by means of liquid chromatography-fluorescence detection. Different experimental parameters were controlled and the optimum conditions found were: three LDPE pellets (∼80 mg) added to 20 mL aqueous sample (20% w:v NaCl) followed by vortex agitation at 3000 rpm; for desorption, the three LDPE pellets were immersed in 100 μL of acetonitrile and the mixture was shaken at 3000 rpm for 5 min using the vortex agitator. The calculated calibration curves gave high levels of linearity yielding coefficients of determination (r2) greater than 0.9913. The precision of the proposed method was found to be good and the limits of the detection were calculated in the low ng L−1 level. Matrix effects were determined by applying the proposed method to spiked river water, treated municipal wastewater and seawater samples. To compensate for the low recoveries of the more hydrophobic PAHs in spiked effluent wastewater and seawater samples the standard addition methodology was applied. The proposed method was applied to the determination of target pollutants in real seawater samples using the standard addition method. Overall, the performance of the proposed P2SE method suggests that the use of inexpensive and easy to reach sorbent materials for extracting analytes in the laboratory merits more intensive investigation.  相似文献   

13.
14.
An automated, simple and sensitive method based on selective pressurized liquid extraction (SPLE) was developed for the analysis of polycyclic aromatic hydrocarbons in sewage sludge samples. The new sample preparation procedure consists of on-line clean-up by inclusion of sorbents in the extraction cell, and combines elevated temperatures and pressures with liquid solvents to achieve fast and efficient removal of target analytes from complex sewage sludge matrices. The effects of various operational parameters (e.g. sample pretreatment, extraction solvent, temperature, pressure, static time, etc.) on the performance of SPLE procedure were carefully investigated, obtaining the best results when SPLE conditions were fixed at 140 °C, 1500 psi, static time of 5 min and n-hexane as extraction solvent. A new programmed temperature vaporization–gas chromatography–tandem mass spectrometry method based on large volume injection (PTV–LVI–GC–MS/MS) was also developed and analytical determinations were performed by high performance liquid chromatography coupled with fluorescence detection and GC–MS/MS. The extraction yields for the different compounds obtained by SPLE ranged from 84.8% to 106.6%. Quantification limits obtained for all of these studied compounds (between 0.0001 and 0.005 μg g−1, dry mass) were well below the regulatory limits for all compounds considered. To test the accuracy of the SPLE technique, the optimized methodology was applied to the analysis of a certified reference material (sewage sludge (BCR088)) and a reference material (sewage sludge (RTC-CNS312-04)), with excellent results.  相似文献   

15.
Continuous ultrasound-assisted extraction of nitropolycyclic aromatic hydrocarbons from soil prior to their individual separation and determination by gas chromatography (GC) with MS-MS detection is presented here. A multivariate optimisation of the variables affecting the continuous extraction step (namely, probe position, ultrasound radiation amplitude, percentage of duty cycle of ultrasonic exposure, sonication time, total extractant volume, extractant flow rate and temperature of the water-bath in which the extraction cell was placed) was performed. The method was compared with the reference EPA method 3540 using natural contaminated soils. Similar efficiencies were obtained but with a drastic reduction of both the extraction time (10 min versus 24 h) and the extractant volume (less than 10 ml versus 100 ml) by the proposed method. Detection limits of low picogram were obtained, with repeatability and reproducibility between 4.21-5.70 and 5.20-7.23%, respectively.  相似文献   

16.
Summary The recorveries of volatile polycyclic aromatic hydrocarbons in HPLC analysis may be enhanced if a long-chain alcohol, e.g. 1-hexanol or 1-octanol, is used as keeper in the solvent-evaporation step. Even under the harsh conditions of the vacuum-concentrator centrifuge, recoveries of more than 90% were achieved for 14 of the 15 PAH tested. The use of liquid-liquid extraction (LLE) eliminates the problem of adsorption of highly condensed aromatics by the wall of the sampling bottle. The combination of LLE with vacuum-controlled rotary evaporation and use of a keeper yielded overall recoveries between 50 and 130%, for most substances close to 100%, from tap water spiked with trace concentrations. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996  相似文献   

17.
Extraction vessels of different length, internal diameter and volume were tested to evaluate the effect of vessel geometry on the recovery of polycyclic aromatic hydrocarbons (PAHs) from certified sediment by pressurised hot water extraction (PHWE). Pressurised hot water extractions were performed at 300 °C with both liquid water (pressure 250 kg cm–2) and steam (pressure 50 kg cm–2). In addition, the effects on the recoveries of sediment packing and water flow direction were examined in two vessels. The geometry of the vessel, the packing of the sediment and the flow direction of the water had only minor effect on the recoveries.  相似文献   

18.
Lubov Oliferova  Yury Zolotov 《Talanta》2007,72(4):1386-1391
Naphthalene, biphenyl, acenaphtene, anthracene and pyrene were extracted from water samples using inner walls of polytetrafluoroethylene capillary. Optimum conditions for sorption, desorption and heart-cutting of the analyte zone were found. Combined on-line solid-phase extraction and HPLC method for determination of these compounds was proposed. Limits of detection were: (μg L−1): 0.4 (naphthalene), 0.3 (biphenyl), 0.6 (acenaphtene), 0.2 (anthracene) and 0.1 (pyrene).  相似文献   

19.
To detect, identify, and quantify the polycyclic aromatic hydrocarbons (PAHs) released into the environment, the PAHs need to be isolated from the soil matrix. In this work, a modified quick, easy, cheap, efficient, rugged and safe (QuEChERS) method with ionic liquid was combined with liquid chromatography to identify 16 selected PAHs in soil. Ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim]PF6) was applied as an extractant component to enhance the process. The [Hmim]PF6 content in acetonitrile (ACN) was optimized. The [Hmim]PF6 modified QuEChERS method has the advantages defined by its name and a similar recovery to other extraction methods reported in the literature. Adding [Hmim]PF6 may eliminate the co-extract proportion and achieve a more effective extraction. Compared with ACN alone, the matrix effect (ME) of ACN containing 5% [Hmim]PF6 was reduced by approximately 35%. Additionally, the ME of using ACN containing [Hmim]PF6 without a clean-up procedure was similar to that of using ACN followed by a clean-up procedure. The recoveries of the QuEChERS method implemented with [Hmim]PF6 ranged from 75.19% to 100.98%. The limits of detection (LOD) and limits of quantification (LOQ) ranged from 0.86 to 4.51 µg/kg and from 2.87 to 15.13 µg/kg, respectively.  相似文献   

20.
Summary In the gas chromatographic determination of polycyclic aromatic hydrocarbons (PAHs), internal standards (ISs) are frequently used in order to correct for losses and fluctuating experimental parameters. In this study eight monofluorinated PAHs (F-PAHs) are used to this end. Analysis was by means of large-volume injection-gas chromatography with mass spectrometric detection (LVI-GC-MS). Relevant experimental results and performance data are presented, and it is demonstrated that the use of at least one F-PAH as IS improves the repeatability dramatically. As a brief application, F-PAHs were used as ISs for the trace-level determination of PAHs in soil, after extraction by means of pressurized liquid extraction (PLE) and liquid partitioning (LP). The suitability of the approach was demonstrated with naphthalene and pyrene as test compounds.  相似文献   