首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 125 毫秒
1.
Summary Laser microprobe mass analysis (LAMMA) was applied to characterize aerosol particles collected and separated from 16m to 0.06m by a low pressure cascade impactor. Positive ion LAMMA spectra showed characteristic molecular peaks such as PbCl+, a series of Si2O+–Si2O4 + and NaAl2Si2O2 +–NaAl2Si2O5 +, and TiO+ in 0.06–0.12m, 0.5–1m and 4–8m fraction, respectively. In the negative ion LAMMA spectra, it was observed that the fragment peaks of sulfate ions were deficient above 2m and those of nitrate ions were deficient under 2m. LAMMA allows remarkable insights into the chemical nature of aerosol particles.
Charakterisierung luftgetragener Teilchen durch Laser-Microprobe-Massenspektrometrie
Zusammenfassung Laser-Microprobe-Spektrometrie (LAMMS) wurde zur Analyse atmosphärischen Aerosols herangezogen, welches im Korngrößenbereich zwischen 16m und 0.06m mit einem Niederdruckkaskadenimpaktor fraktioniert gesammelt wurde. Positive LAMMS-Spektren zeigten charakteristische molekulare Peaks, wie etwa PbCl+, eine Serie von Si2O+–Si2O4 + und NaAl2Si2O2 +–NaAl2Si2O5 +, sowie TiO+ in der 0,06–0,12-m,- 0,5–1–m- bzw. 4–8-m-Fraktion. In den negativen LAMMS-Spektren konnten über 2m keine Fragmentpeaks für Sulfationen, unter 2m. keine für Nitrationen beobachtet werden. LAMMS ermöglicht eine bemerkenswerte Einsicht in die chemische Natur von Aerosolteilchen.
  相似文献   

2.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

3.
Summary For the trace determination of sodium alkylbenzenesulphonate (ABS) by HPLC the following conditions were employed: Shimadzu ZORBAX SIL Column (5 m, 4.6 mm i.d. x 150 mm) as stationary phase, 0.2% ammoniaethanol (v/v) as mobile phase, UV detector at 225 nm, injection volume 12 l. The chromatograms of ABS were simple and sharp (detection limit of ABS 0.02 g in 12 l of ethanol). The calibration curves of ABS were linear in a concentration range of 0.03 0.3 g in 12 l of ethanol. In the case of linear sodium dodecylbenzenesulphonate positive errors of 1 4% were caused by non-ionic surfactants or laurylsulphate (6 times excess), 10 50% positive errors were caused by 2 6 times excess of household detergents.Standard water samples containing ABS were treated with a weak base anion-exchange resin, the adsorbed ABS were eluted, and then determined either by HPLC or by the methylene blue spectrophotometric method. Recoveries of ABS in water were about 92 107% by HPLC.
Bestimmung von Spuren Natriumalkylbenzolsulfonat mit Hilfe der HPLC. Anwendung auf Wasser
Zusammenfassung Für die Spurenbestimmung von Natriumalkylbenzolsulfonat (ABS) durch HPLC werden die folgenden Bedingungen empfohlen:Shimadzu ZORBAX SIL (5 m, 4,6 mm x 150 mm) als stationäre Phase, 0,2% Ammoniak/Ethanol als mobile Phase, UV-Detektor bei 225 nm, Injektionsvolumen 12 l. Die erhaltenen Chromatogramme sind einfach und scharf (Nachweisgrenze 0,02 g in 12 ml Ethanol). Die Eichkurven sind im Konzentrationsbereich von 0,03–0,3 g in 12 l Ethanol linear. Im Falle des linearen Natriumdodecylbenzolsulfonats werden bei Anwesenheit von nicht-ionischen oberflächenaktiven Substanzen oder von Laurylsulfat in 6fachem Überschuß positiver Fehler von 1–4% erhalten; bei 2–6fachem Überschuß von Haushaltswaschmitteln ergeben sich positive Fehler von 10–50%.Standard-Wasserproben werden zunächst einer Behandlung mit einem Anionenaustauscher unterzogen, die adsorbierten ABS eluiert und durch HPLC oder nach der Methylenblaumethode analysiert. Wiederfindungsraten liegen bei 92–107%.
  相似文献   

4.
    
Zusammenfassung Die Trennung von Saccharin und Dulcin erfolgt durch Lösen des Natriumsaccharinats in Wasser und anschließende Extraktion des Saccharins mit Äthylacetat aus der angesäuerten wäßrigen Lösung. Dulcin wird im Rückstand vom Wasserauszug mit Eisessig gelöst. Die Extrakte werden auf mit Kieselgel HF254 beschichteten Platten mit ChloroformEisessig als Fließmittel getrennt chromatographiert und mit kurzwelligem UV-Licht sichtbar gemacht. Auf diese Weise lassen sich noch l g Dulcin und 5 g Saccharin einwandfrei erfassen und im Bereich bis zu etwa 50 g mit einer Genauigkeit von ± 5 g bestimmen.
Summary For the separation of saccharin and dulcin the sodium salt of saccharin is dissolved in water and after acidifying the solution saccharin is extracted with ethyl acetate. The remaining dulcin is dissolved in glacial acetic acid. Of each of these extracts a separate thin-layer chromatogram is prepared using chloroform-glacial acetic acid as solvent. The two sweetening agents can be made visible by UV-light. In this way 1 g of dulcin and 5 g of saccharin are detectable and up to 50 g of both substances can be determined with an accuracy of ± 5 g. Für ihre wertvolle Mithilfe bei der Durchführung der Analysen danken wir Fräulein Marianne Hornschuh herzlich.
  相似文献   

5.
Summary A method has been developed for the semiautomatic potentiometric titration of thiourea with silver nitrate and of silver with thiourea, in the presence of picrate ions, using a picrate ion selective electrode. Thiourea in the range 15–1500g and silver in the range 200–1800g were determined with relative errors and relative standard deviation of about 1%.
Zusammenfassung Eine halbautomatische potentiometrische Titrationsmethode für Thioharnstoff mit Silbernitrat bzw. umgekehrt in Gegenwart von Pikrationen mit Hilfe einer selektiven Pikratelektrode wurde entwickelt. 15–1500g Thioharnstoff bzw. 200–1800g Silber wurden mit einem relativen Fehler und einer relativen Standardabweichung von etwa ±1% bestimmt.
  相似文献   

6.
Summary Studies were conducted on the assay of Sm, Eu, Dy and Er separated from uranium using aqueous standards by electrothermal AAS with Massmann type graphite furnace. The working curves were found to be linear in the ranges Sm (1–10 g/ml), Eu (0.05–0.6 g/ml), Dy (0.1–0.8 g/ml) and Er (0.1–1.0 g/ml). The values obtained for synthetic samples agreed favourably with those obtained by emission spectrographic method. Experiments using pyrolytic carbon coated tubes with and without pretreatment by La, Ta and Y have shown an enhancement with treatment upto a maximum of 15% and improve the memory effect marginally. The effect of Ta treatment was found to be singularly useful in improving the general behaviour of Sm. The interference effects of lanthanides, other than the analyte, were found to be negligible. However, the presence of uranium was found to affect the absorbance. The absorbance of Eu was found to be nearly independent of uranium after an initial increase. On the other hand, the absorbance of other elements studied was found to drastically decrease after an initial enhancement. Detailed investigations of temperature dependence of absorbance were carried out using Eu, Dy and Er. The differences in the behaviour of these elements is attributed to probable differences in the modes of their atomization.
Untersuchung von aus Uran abgetrenntem Samarium, Europium, Dysprosium und Erbium durch elektrothermische Atomabsorptions-Spektralphotometrie
Zusammenfassung Die Untersuchungen wurden mit Hilfe des Graphitrohrofens nach Maßmann durchgeführt. In folgenden Bereichen ergaben sich lineare Eichkurven: Sm 1–10 g/ml, Eu 0,05–0,6 g/ml, Dy 0,1–0,8 g/ml, Er 0,1-1,0 g/ml. Die aus synthetischen Proben erhaltenen Ergebnisse stimmten gut mit den durch Emissionsspektrographie erhaltenen überein. Versuche wurden mit Röhren mit pyrolytischen Kohlenstoffüberzug mit und ohne Vorbehandlung durch La, Ta und Y durchgeführt und ergaben eine bis 15%ige Steigerung durch die Behandlung sowie eine mäßige Besserung des Memoryeffektes. Eine Behandlung mit Ta war besonders für Sm vorteilhaft. Störungen durch andere Lanthanide waren vernachlässigbar. Uran beeinflußte jedoch die Absorption. Im Falle von Eu zeigte sich nach anfänglicher Zunahme fast eine Unabhängigkeit, während bei den anderen untersuchten Elementen nach anfänglicher Zunahme eine beträchtliche Abnahme auftrat. Mit Eu, Dy und Er wurde ebenfalls die Temperaturabhängigkeit der Absorption untersucht. Festgestellte Unterschiede im Verhalten werden auf unterschiedliche Atomisierung zurückgeführt.
  相似文献   

7.
Summary A new procedure is proposed for the photometric determination of molybdenum in iron and steels using thiocyanate and tin(II) chloride solution [in glycerol-ethannol (31) or in diethylenglycol] as a reducer and extraction with n-butyl acetate. Beer's law is obeyed between 0.2 and 80 g Mo/ml. The minimum photometric error is 3.2%, the molar absorptivity is 15640 at 470 nm and the best concentration range for determination is between 0.6 and 6 g Mo/ml.
Photometrische Bestimmung von Molybdän in Eisen und Stahl mit Hilfe von Zinn(II)-chlorid in nichtwärigem Medium
Zusammenfassung Das vorgeschlagene Verfahren beruht auf Bildung des Thiocyanatkomplexes unter Verwendung von Zinn(II)-chlorid als Reduktionsmittel [in Glycerin/Äthanol (31) oder Diäthylenglykol]. Als Extraktionsmittel dient n-Butylacetat. Das Beersche Gesetz wird im Bereich 0,2–80 g Mo/l befolgt. Der kleinste photometrische Fehler beträgt 3,2%, die molare Extinktion 15640 bei 470 nm und der optimale Konzentrationsbereich 0,6–6 gMo/l.
Lecture presented at Euroanalysis I Conference, 28. 8. –1. 9. 1972 in Heidelberg, Germany.  相似文献   

8.
Zusammenfassung Die Landolt-Reaktion auf Bromgrundlage des Systems Wasserstoffperoxid—Bromid—Ascorbinsäure—Tolidin wird durch Mo(VI), Fe(III), Cu(II), V(V) und W(VI) katalysiert. Auf dieser Grundlage läßt sich Mo(VI) mit Hilfe der Simultankomparationsmethode bei 65° C in einem Konzentrationsbereich von 1 bis 10g/5 ml und bei 50° C in einem Konzentrationsbereich von 0,1 bis 1g/5 ml mit einem relativen Fehler von ±0.5% bestimmen.
Summary The Landolt reaction on a bromine basis of the system hydrogen peroxide-bromide-ascorbic acid-tolidine is catalyzed by Mo(VI), Fe(III), Cu(II), V(V), and W(VI). On this basis, Mo(VI) can be determined with the aid of the simultaneous comparation method at 65° C in a concentration range from 1 to 10g/5 ml and at 50° C in a concentration range from 0.1 to 1g/5 ml with a relative error of ±0.5%.

Résumé La «réaction de Landolt, avec brome» du système eau oxygénée—bromure—acide ascorbique—tolidine, est catalysée par Mo-VI, Fe-III, Cu-II, V-V et W-VT. On peut donc doser Mo-VI par la méthode de comparaison simultanée à 65° C dans un domaine de concentration de 1 à 10g/5 ml et à 50° C de 0,1 à 1g/5 ml avec une erreur relative de ±0,5%.


Die vorliegende Arbeit sollte Herrn Prof. Dr.E. Schulek zu seinem 70. Geburtstag gewidmet werden. Noch ehe die Publikation möglich war, ist Herr Prof.Schulek am 14. Oktober 1964 leider gestorben.  相似文献   

9.
Zusammenfassung Eine acidimetrische automatisierte Titration von 0,5–10g Kohlenstoff als Kohlendioxid wird vorgeschlagen. Das Kohlendioxid wird in einem Trägergasstrom durch 80 ml einer auf 0° C gekühlten wäßrigen Lösung geleitet, die das Enzym Carboanhydrase und einen sehr verdünnten Veronalpuffer (pH etwa 8) enthält. Das Kohlendioxid wird mit 0,01–n Natronlauge titriert bis zum pH-Sollwert. Durch Beseitigungen mancher Störungsquellen war das Rauschen beschränkt auf 0,4 V. Die Standardabweichung war durchschnittlich geringer als 1% bei einem Blindwert von 0,00g C. Die Dauer der Bestimmung beträgt 6 min.
On the automatic determination of carbon. V
Summary An automated acidimétric titration of 0.5–10g of carbon as carbon dioxide is proposed. The carbon dioxide is swept in a stream of carrier gas through about 80 ml of a solution of the enzyme carbo anhydrase and a very diluted veronal buffer (pH about 8). This solution is cooled to 0° C. The set point titration is carried out using 0.01 N sodium hydroxide. The noise in the signal could be kept below 0.4V. The standard deviation usually was below 1%; the blank was 0.00g C. A determination takes 6 min.
  相似文献   

10.
Zusammenfassung Es wird eine photometrische Bestimmungsmethode beschrieben für Anilin (40–720 g/ml), Monoäthylanilin (90–1650 g/ml) und Diäthylanilin (100–1600 g/ml) mit Natriumchlorit in äthanolisch-wäßrigen Lösungen, sowie für Diäthylanilin (85–1140 g/ml) und Dimethylanilin (30–330 g/ml) neben den primären und sekundären Aminen in essigsaurer Lösung mit demselben Reagens. Das Verfahren liefert gute Ergebnisse.
Summary A photometric procedure is described for the determination of aniline (40–720 g/ml), monoethylaniline (90–1650 g/ml), and diethylaniline (100–1600 g/ml) with sodium chlorite in aqueous ethanolic solutions and of diethylaniline (85–1140 g/ml) and dimethylamline (30 to 330 g/ml) in presence of the primary and secondary amines in acetic acid solution using the same reagent. Good results have been obtained,
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏