首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Koay ES  Zhu M  Wehr T  Choong ML  Khaw MC  Sethi SK  Aw TC 《Talanta》1998,45(4):673-681
The apolipoprotein E (apo-E) genotype of an individual is of significant relevance in the associated risk of developing cardiovascular disease and late-onset Alzheimer's disease. Detection of the six common apo-E genotypes is based on the restriction fragment length polymorphisms (RFLPs) arising from the abolition or creation of HhaI restriction sites within an amplified target DNA sequence of the apo-E gene. Genomic DNA was extracted from leukocytes, a 230 bp target sequence within the apo-E gene was amplified by polymerase chain reaction (PCR) and digested with HhaI, and the restricted DNA fragments separated by capillary electrophoresis (CE). This was performed on the BioFocustrade mark 3000 automated CE system equipped with an experimental laser-induced fluorescence (LIF) detector (Bio-Rad Laboratories, Hercules, CA), using capillaries (27 cm length, 75 mum i.d.) coated internally with polyaminoacryloylethoxyethanol. The analysis buffer (2xTris borate-EDTA, pH 8.3) was supplemented with a proprietary sieving polymer and 0.05 muM thiazole orange six. Samples were injected electrophoretically. Separations were carried out at 40 degrees C under constant voltage, and the emitted fluorescence detected at 515 nm. Restriction fragment lengths of the cleaved PCR products were estimated from the migration times, with a 20/100 bp ladder (Bio-Rad Laboratories 20/100 bp molecular ruler) serving as reference. Six different reproducible patterns were obtained for the six common apo-E genotypes, with good resolution of the component restriction fragments. The calculated sizes of the separated peaks closely corresponded with the predicted restricted fragment lengths for each specific genotype. We believe this is the first published report demonstrating the feasibility of automating the post-PCR detection of the apo-E RFLPs(2). This methodology overcomes the most labour-intensive step in apo-E genotyping, thus making it amenable to routine clinical application.  相似文献   

2.
Species identification plays an important role in food allergy prevention and food substitution detection that can reduce the commercial value of a product. For these reasons, many molecular methods have been developed to determine species origin; among them, polymerase chain reaction (PCR)-based methods were successfully applied to processed or unprocessed foodstuffs. An updated PCR-RFLP (restriction fragment length polymorphism) method of the cytb gene was developed for the identification of the 4 species of main interest in the dairy industry (Bos, Ovis, Capra, Bubalus). The comparative analysis of the 92 cytb sequences available in the database belonging to the 4 species allowed identification of 2 highly conserved regions, which were used to design 2 oligonucleotides for the PCR amplification of a 275 base-pair (bp) cytb fragment. The in silico analysis allowed identification of a set of species-specific restriction endonucleases (HaeIII, TaqI, and MwoI), which generated easily analyzable species-specific restriction profiles of the 275 bp cytb DNA fragment. The system was developed for both purified DNA and DNA extracted from meat or dairy products and finally tested on mixed samples, indicating its applicability to foodstuffs.  相似文献   

3.
Capillary electrophoresis (CE) is a new, high-resolution tool for the analysis of DNA restriction fragments and DNA amplified by the polymerase chain reaction (PCR). By combining many of the principles of traditional slab gel methods in a capillary format, it is possible to perform molecular size determinations of human and plant PCR amplification products and DNA restriction fragments. DNA restriction fragments and PCR products were analyzed by dynamic sieving electrophoresis (DSE) and capillary gel electrophoresis (CGE). As part of this study, sample preparation procedures, injection modes, and the use of molecular mass markers were evaluated. Optimum separations were performed using the uPage-3 (3% T, 3% C) CGE columns with UV detection at 260 nm. Membrane dialysis and ultrafiltration/centrifugation proved to be nearly equivalent methods of sample preparation. Reproducibility studies demonstrated that blunt-ended, non-phosphorylated markers (specifically allele generated markers) provide the most accurate calibration for PCR product analysis. This study demonstrates that CE offers a high-speed, high-resolution analytical method for accurately determining molecular size and/or allelic type as compared with traditional methodologies.  相似文献   

4.
Huang FC  Chen YF  Lee GB 《Electrophoresis》2007,28(7):1130-1137
This study presents a new packaging method using a polyethylene/thermoplastic elastomer (PE/TPE) film to seal an injection-molded CE chip made of either poly(methyl methacrylate) (PMMA) or polycarbonate (PC) materials. The packaging is performed at atmospheric pressure and at room temperature, which is a fast, easy, and reliable bonding method to form a sealed CE chip for chemical analysis and biomedical applications. The fabrication of PMMA and PC microfluidic channels is accomplished by using an injection-molding process, which could be mass-produced for commercial applications. In addition to microfluidic CE channels, 3-D reservoirs for storing biosamples, and CE buffers are also formed during this injection-molding process. With this approach, a commercial CE chip can be of low cost and disposable. Finally, the functionality of the mass-produced CE chip is demonstrated through its successful separation of phiX174 DNA/HaeIII markers. Experimental data show that the S/N for the CE chips using the PE/TPE film has a value of 5.34, when utilizing DNA markers with a concentration of 2 ng/microL and a CE buffer of 2% hydroxypropyl-methylcellulose (HPMC) in Tris-borate-EDTA (TBE) with 1% YO-PRO-1 fluorescent dye. Thus, the detection limit of the developed chips is improved. Lastly, the developed CE chips are used for the separation and detection of PCR products. A mixture of an amplified antibiotic gene for Streptococcus pneumoniae and phiX174 DNA/HaeIII markers was successfully separated and detected by using the proposed CE chips. Experimental data show that these DNA samples were separated within 2 min. The study proposed a promising method for the development of mass-produced CE chips.  相似文献   

5.
Tseng WL  Lin YW  Chen KC  Chang HT 《Electrophoresis》2002,23(15):2477-2484
Microfluidic devices with bubble cells have been fabricated on poly(methyl methacrylate) (PMMA) plates and have been employed for the analysis of DNA using polyethylene oxide (PEO) solutions. First, the separation channel was fabricated using a wire-imprinting method. Then, wires with greater sizes or a razor blade glued in a polycarbonate plate was used to fabricate bubble cells, with sizes of 190-650 microm. The improvements in resolution and sensitivity have been achieved for large DNA (> 603 base pair, bp) using such devices, which depend on the geometry of the bubble cell. The main contributor for optimal resolution is mainly due to DNA migration at lower electric field strengths inside the bubble cell. On the other hand, slight losses of resolution for small DNA fragments have been found mainly due to diffusion, supported by the loss of resolution when separating two small solutes. With a bubble cell of 75 microm (width) x 500 microm (depth), the sensitivity improvement up to 17-fold has been achieved for the 271 bp fragment in the separation of PhiX-174/HaeIII DNA restriction fragments. We have also found that a microfluidic device with a bubble cell of 360 microm x 360 microm is appropriate for DNA analysis. Such a device has been used for separating DNA ranging from 8 to 2176 bp and polymerase chain reaction (PCR) products amplified after 30 cycles, with rapidity and improvements in the sensitivity as well as resolution.  相似文献   

6.
Three methods [capillary electrophoresis (CE)-allele-specific PCR, CE-single-strand conformation polymorphism (SSCP) and CE-cleavase fragment length polymorphism (CFLP)] were developed in order to effect rapid and specific analysis of the vero toxin (VT)1 and VT2 genes of O157. The allele-specific polymerase chain reaction (PCR) method, which utilized specific duplex PCR with specific primers for VT1 and VT2, showed that VT1 and VT2 consisted of 174 and 128 bp, respectively. Subsequent CE analysis was carried out. Separation time was 4 min. SSCP, which utilized one primer set which reacted with both VT1 and VT2 in the PCR method, was followed by CE analysis of secondary structure of single-strand DNA. Two genes could be analyzed in approximately 18 min. CFLP, like SSCP, is a method for detecting mutation-induced changes in secondary structure of single-stranded DNA. The endonuclease cleavase I recognizes and cleaves the 5' side of hairpin loops in self-annealed single-strand DNA of PCR product 169 bp obtained from VT1 and VT2. The produced DNA fragments are analyzed by CE and the electrophelogram reveals a sequence-specific CFLP. Separation time was 6 min. These techniques are suitable for the detection and the identification of O157.  相似文献   

7.
8.
B F Liu  Q G Xie  Y T Lu 《Analytical sciences》2001,17(11):1253-1256
It was demonstrated that a capillary electrophoresis (CE) method with a non-gel sieving solution has been developed to identify the orientation of DNA fragments in recombinant plasmids in molecular biology. The influences of the concentration of sieving polymer HEC, the applied electric field strength and sampling on CE separation were analyzed concerning the optimization of separation. YO-PRO-1 was used as a DNA intercalating reagent to facilitate fluorescence detection. Under the chosen conditions (buffer, 1 x TBE containing 1 microM YO-PRO-1 and 1.2% HEC; applied electric field strength, 200 V/cm; electrokinetic sampling: time, 5 s; voltage, -6 kV), three DNA markers (phi 174/HaeIII, pBR322/HaeIII and lambda DNA/HindIII) were tested for further evaluating the relationship between the DNA size and the mobility. The established CE method conjugated with the enzymatic approach was successfully applied to identifying the DNA orientation of recombinant plasmid in transgene operations of a newly cloned gene from Arabidopsis Thaliana.  相似文献   

9.
毛红霞  黎源倩  裴晓方  何超  渠凌丽 《色谱》2007,25(4):473-477
建立了食品中常见致病菌大肠杆菌O157:H7的uidA基因、沙门菌的invA基因和志贺菌的ipaH基因的多重聚合酶链反应(PCR)产物的毛细管电泳快速检测方法。根据这3种致病菌的特异性基因序列设计多重PCR引物,优化PCR扩增反应体系,采用7.0 g/L 甲基纤维素为筛分介质,毛细管电泳-激光诱导荧光检测法同时检测了3种常见致病菌的PCR扩增产物。在优化的多重PCR反应和毛细管筛分电泳条件下,该方法可以同时检测沙门菌、志贺菌和大肠杆菌O157:H7基因的多重PCR扩增产物,22 min内即可完成3种常见致病菌的毛细管电泳检测。迁移时间的相对标准偏差为1.47%~2.07%。与凝胶电泳法比较,该法简便快速,灵敏度高,可用于多种致病菌脱氧核糖核酸的检测,为食品安全提供了一种可靠的快速检测方法。  相似文献   

10.
Raw and smoked samples of Atlantic salmon (Salmo salar) and rainbow trout (Oncorhynchus mykiss) were identified using polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) of the p53 gene. DNA from S. salar and 0. mykiss was amplified by using primers flanking exons 5 to 6 of the p53 nuclear gene. PCR products of different length were obtained for each species (532 and 518 base pairs, respectively). Sequences of PCR products obtained from S. salar and O. mykiss were compared in the search for polymorphic restriction sites. The restriction fragments obtained with Eco RV, Hinf I, and Taq I endonucleases showed interspecific polymorphism, making it a useful method for identification of Atlantic salmon and rainbow trout.  相似文献   

11.
The rapid development of DNA capillary electrophoresis (CE) technology has increased the demand of new low viscosity sieving matrices with high separation capacity. The high throughput, resolution and automatic operation of CE systems have stimulated the application of the technique to different kinds of DNA analysis, including DNA sequencing, separation of restriction fragments, PCR products and synthetic oligonucleotides. In addition specific methods for PCR-based mutation assays for the study of known and unknown point mutations have been developed for use in CE. The key component for a large scale application of CE to DNA analysis is the availability of appropriate sieving matrices. This article gives an overview of the linear polymers used as DNA separation matrices with particular emphasis on the polymers that combine high sieving capacity, low viscosity and chemical resistance.  相似文献   

12.
The improvement of sensitivity and differentiation in rapidly identifying a small amount of mycobacteria in sputum has significant implications for reducing tuberculosis transmission. We previously applied the conventional PCR and capillary electrophoresis (CE) to establish the restriction fragment length polymorphism (RFLP) pattern of mycobacterial 65-kDa heat shock protein (hsp65) gene from colony specimens. However, the previous analysis did not provide enough sensitivity for sputum specimens in which the limitation of analysis might be hindered by PCR inhibitors and primer-dimers formation during amplification. In the current study, nested PCR (nPCR) had been redesigned for PCR-RFLP analysis (PRA) of mycobacterial hsp65 gene using CE. The results show both Mycobacterium tuberculosis complex and mycobacteria other than tuberculosis could be identified in the presence of PCR inhibitors. The interference due to primer-dimers was also minimized. Based on the Poisson distribution, the repeatability of single DNA molecule detection was greatly affected by sampling probability and might be improved significantly by increasing the sample loading. The PRA using nPCR and CE is not only able to detect the individual mycobacterial DNA molecule but also potentially differentiate the species.  相似文献   

13.
Xu F  Jabasini M  Liu S  Baba Y 《The Analyst》2003,128(6):589-592
On a polymethylmethacrylate (PMMA) microchip, double-stranded DNA fragments with a wide size range from 50 bp to 20 kbp were separated by two polymer solutions. One was a hydroxypropylmethylcellulose-4000 (HPMC-4000) solution of 1.3% (w/v) to separate fragments below 590 bp, and another was a mixed four molecular weight poly(ethylene oxide) solution at a total concentration of 0.1% to separate fragments above 520 bp. The widths at half height (wh) of the fragments had a good relationship with their migration times (tR) in both polymer solutions. Such a relationship was suitable for obtaining the wh values of unresolved peaks, calculating the resolution of two adjacent fragments, and optimizing microchip separation matrices. Based on the relativity, a low viscosity medium containing 2% HPMC-50 and 8% glucose was optimized for high-performance separation of a phiX174 HaeIII restriction fragment digest.  相似文献   

14.
Inexpensive and permanently modified poly(methyl methacrylate)(PMMA) microchips were fabricated by an injection-molding process. A novel sealing method for plastic microchips at room temperature was introduced. Run-to-run and chip-to-chip reproducibility was good, with relative standard deviation values between 1-3% for the run-to-run and less than 2.1% for the chip-to-chip comparisons. Acrylonitrile-butadiene-styrene (ABS) was used as an additive in PMMA substrates. The proportions of PMMA and ABS were optimized. ABS may be considered as a modifier, which obviously improved some characteristics of the microchip, such as the hydrophilicity and the electro-osmotic flow (EOF). The detection limit of Rhodamine 6G dye for the modified microchip on the home-made microchip analyzer showed a dramatic 100-fold improvement over that for the unmodified PMMA chip. A detection limit of the order of 10(-20) mole has been achieved for each injected psiX-174/HaeIII DNA fragment with the baseline separation between 271 and 281 bp, and fast separation of 11 DNA restriction fragments within 180 seconds. Analysis of a PCR product from the tobacco ACT gene was performed on the modified microchip as an application example.  相似文献   

15.
CE fingerprint methods are commonly used in microbial ecology. We have previously noticed that the position and number of peaks in CE-SSCP (single-strand conformation polymorphism) profiles depend on the DNA polymerase used in PCR [1]. Here, we studied the fragments produced by Taq polymerase as well as four commercially available proofreading polymerases, using the V3 region of the Escherichia coli rss gene as a marker. PCR products rendered multiple peaks in denaturing CE; Taq polymerase was observed to produce the longest fragments. Incubation of the fragments with T4 DNA polymerase indicated that the 3'-ends of the proofreading polymerase amplicons were recessed, while the Taq amplicon was partially +A tailed. Treatment of the PCR product with proofreading DNA polymerase rendered trimmed fragments. This was due to the 3'-5' exonuclease activity of these enzymes, which is essential for proofreading. The nuclease activity was reduced by increasing the concentration of dNTP. The Platinum Pfx DNA polymerase generated very few artifacts and could produce 85% of blunted PCR products. Nevertheless, despite the higher error rate, we recommend the use of Taq polymerase rather than proofreading in the framework for molecular fingerprint studies. They are more cost-effective and therefore ideally suited for high-throughput analysis; the +A tail artifact rate can be controlled by modifying the PCR primers and the reaction conditions.  相似文献   

16.
Hsieh MM  Chang PL  Chang HT 《Electrophoresis》2002,23(15):2388-2393
A partially filling technique for the analysis of DNA markers and polymerase chain reaction (PCR) products by capillary electrophoresis in the presence of electroosmotic flow using polymer solutions is presented. Either after or prior to the sample injection, a plug of salts at high pH was hydrodynamically injected. During the separation, poly(ethylene oxide) (PEO) solution entered the capillary. We have found that the position, length, and composition of the plugs affect the sensitivity, resolution, and speed on the analysis of PhiX-174/HaeIII DNA restriction fragments or a DNA mixture (pBR 322/HaeIII digest, pBR 328/BglI digest and pBR 328/HinfI digest) with different degrees. Through careful evaluation of the impact of anions and cations on the analysis of DNA, we have suggested that the optimal condition is applying a plug consisting of 32 mM NaCl and 0.01 M NaOH at 30 cm height for 60 s after sample injection. In the presence of such a plug, PEO adsorption reduces, and thus the separation is faster, as well as the sensitivity improves. Using this condition, the analysis of a DNA mixture (injected at 30 cm for 360 s) containing ten different PCR products amplified after 17 cycles was complete in 25 min. About a 2000-fold improvement in the sensitivity was achieved when compared to that by a conventional method (10 s injection) without applying a plug.  相似文献   

17.
Chen S  Zhang J  Chen W  Xu D  Zhou Y 《色谱》2011,29(7):677-680
应用聚合酶链式反应-限制性片段长度多态性分析(PCR-RFLP)和芯片生物分析系统建立了台湾海峡常见石斑鱼和鲷鱼的分子生物学品种鉴定新方法。首先提取鱼的基因组脱氧核糖核酸(DNA)进行细胞色素b基因特定片段的PCR扩增,然后用DdeI、HaeIII和NlaIII 3种限制性内切酶进行酶切,在Agilent DNA 1000芯片上对酶切片段进行分离。该方法成功鉴定了台湾海峡常见的8种石斑鱼品种和5种鲷鱼品种,是一种快速、简便、有效的鱼类品种鉴定分析手段。  相似文献   

18.
Huang MF  Hsu CE  Tseng WL  Lin YC  Chang HT 《Electrophoresis》2001,22(11):2281-2290
Separations of phiX-174/HaeIII DNA restriction fragments have been performed in the presence of electroosmotic flow (EOF) using five different polymer solutions, including linear polyacrylamide (LPA), poly(ethylene oxide) (PEO), hydroxypropylcellulose (HPC), hydroxyethylcellulose (HEC), and agarose. During the separation, polymer solutions entered the capillary by EOF. When using LPA solutions, bulk EOF is small due to adsorption on the capillary wall. On the other hand, separation is faster and better for the large DNA fragments (> 872 base pairs, bp) using derivative celluloses and PEO solutions. Several approaches to optimum resolution and speed by controlling EOF and/or altering electrophoretic mobility of DNA have been developed, including (i) stepwise changes of ethidium bromide (0.5-5 microg/mL), (ii) voltage programming (125-375 V/cm), (iii) use of mixed polymer solutions, and (iv) use of high concentrations of Tris-borate (TB) buffers. The DNA fragments ranging from 434 to 653 bp that were not separated using 2% PEO (8,000,000) under isocratic conditions have been completely resolved by either stepwise changes of ethidium bromide or voltage programming. Compared to PEO solutions, mixed polymer solutions prepared from PEO and HEC provide higher resolving power. Using a capillary filled with 600 mM TB buffers, pH 10.0, high-speed (< 15 min) separation of DNA (pBR 322/HaeIII digest, pBR 328/ Bg/l digest and pBR 328/Hinfl digest) has been achieved in 1.5% PEO.  相似文献   

19.
Forensic DNA profiling uses a series of commercial kits that co‐amplify several loci in one reaction; the products of the PCR are fluorescently labelled and analysed using CE. Before CE, an aliquot of the PCR is mixed with formamide and an internal lane size standard. Using the SGM Plus amplification kit, we have developed two internal non‐amplified controls of 80 bp and 380 bp that are labelled with ROX fluorescent dye and added to the PCR. Combined with two internal amplification controls of 90 bp and 410 bp, they provide additional controls for the PCR, electrokinetic injection, and CE and also function as an internal size standard.  相似文献   

20.
Microfabrication technology was used to develop a system consisting of disposable glass chips containing etched channels, reagents including polymer matrix and size standards, computer-controlled instrumentation for performing electrophoretic separations and fluorescence detection of double-stranded DNA, and software for automated data analysis. System performance was validated for separation and quantitation reproducibility using samples varying in amount and size of DNA fragments, buffer composition, and salt concentrations. Several applications of the microfluidic system for DNA analysis have been demonstrated, such as of polymerase chain reaction (PCR) products, sizing of plasmid digests, and detection of point mutations by restriction fragment length polymorphism (RFLP) mapping.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号