首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Wei F  Fan Y  Zhang M  Feng YQ 《Electrophoresis》2005,26(16):3141-3150
A method based on in-tube solid-phase microextraction and capillary zone electrophoresis (CZE) was proposed for simultaneously determining four amphetamines (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, and 3,4-methylenedioxymethamphetamine) in urine. A poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column, which can provide sufficient extraction efficiency, was introduced for the extraction of amphetamines from urine samples. The hydrophobic main chains and acidic pendant groups of the monolithic column make it a superior material for extraction of basic analytes from aqueous matrix. After extraction, the samples were analyzed by CZE. The best separation was achieved using a buffer composed of 0.1 M disodium hydrogen phosphate (adjusted to pH 4.5 with 1 M hydrochloric acid) and 20% methanol v/v, with a temperature and voltage of 25 degrees C and 20 kV, respectively. By applying electrokinetic injection with field-amplified sample stacking, detection limits of 25-34 microg/L were achieved. Excellent method of reproducibility was found over a linear range of 0.1-5 mg/L. Determination of these analytes from abusers' urine sample was also demonstrated.  相似文献   

2.
A method using an online solid-phase extraction (SPE) and ion-pairing liquid chromatography with electrospray tandem mass spectrometry (LC/ES-MS/MS) was developed for determination of amphetamine (Amp), methamphetamine (mAmp), 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxyethylamphetamine (MDEA), and 3,4-methylenedioxymethamphetamine (MDMA) in urine samples. A SPE cartridge column with both hydrophilic and lipophilic functions was utilized for online extraction. A reversed-phase C18 LC column was employed for LC separation and MS/MS was used for detection. Trifluoroacetic acid was added to the mobile phase as an ion-pairing reagent. This method was fully automated and the extraction and analysis procedures were controlled by a six-port switch valve. Recoveries ranging from 85-101% were measured. Good linear ranges (10-500 ng/mL) for Amp and mAmp were determined. For MDA, MDMA and MDEA, dual linear ranges were obtained from 5-100 and 100-500 ng/mL, respectively. The detection limit of each analytical compound, based on a signal-to-noise ratio of 3, ranged from 1-3 ng/mL. The applicability of this newly developed method was examined by analyzing several urine samples from drug users. Good agreement was obtained between the results from this method and a literature GC/MS method.  相似文献   

3.
建立了人体尿液中甲基苯丙胺(MA)、3,4-亚甲二氧基苯丙胺(MDA)、3,4-亚甲二氧基甲基苯丙胺(MDMA)的微波萃取-气相色谱(GC)测定方法。分别考察了萃取溶剂种类、用量、pH值以及萃取温度、时间等因素对萃取率的影响。实验结果表明,尿液中MA,MDA,MDMA的最佳提取条件为:调节尿样pH为12,以环己烷为萃取溶剂,于40 ℃下微波提取10 min。在此条件下MA,MDA,MDMA的平均回收率分别为92.25%,85.94%和91.50%,相对标准偏差分别为5.5%,5.5%和6.1% (n=5),提取液经气相色谱-氢火焰离子化检测器(GC-FID)检测,3种药物与基体得到了很好的分离,对尿液中MA,MDA,MDMA的最低检测限分别为10,20和20 ng/mL。该方法未对药物进行衍生化,是一种快速、准确、灵敏度高的同时测定尿液中MA,MDA,MDMA的方法。  相似文献   

4.
建立了胶束电动毛细管色谱结合电化学安培检测同时分析中药马齿苋中多巴胺和去甲肾上腺素的方法。考察了缓冲液的浓度、pH值、十二烷基硫酸钠(SDS)浓度以及工作电极电势对分离检测的影响。在优化的条件下,多巴胺和去甲肾上腺素在1.0×10-6~5 0×10-4mol/L范围内有良好线性,浓度检测限(S/N=3)分别为8 7×10-7mol/L和4 2×10-7mol/L,质量检测限分别为1 45fmol和0 41fmol。该方法组分定性可靠,不需要衍生处理,选择性好。将该法应用于中药马齿苋样品的分析,获得了较好的结果。  相似文献   

5.
In this study, we present a capillary electrochromatographic method for separation of basic compounds of interest in forensic science (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, 3,4-methylenedioxyethylamphetamine, cocaine, codeine, heroin, morphine, and 6-monoacethylmorphine). Several analytical conditions were taken into account to completely separate in the same run the 10 drugs of abuse analyzed. Chromatographic retention, selectivity and efficiency were evaluated in dependence of the type of stationary phase (CN and RP-C18 derivatized silica particles), mobile phase composition, buffer type and pH, sample injection. The optimum separation parameters were set up using a mixture of aqueous sodium phosphate buffer (pH 2.5)/acetonitrile (80/20, v/v) as the mobile phase, 10 kV and 20 °C as applied voltage and capillary temperature, respectively. Under these conditions all the studied analytes were baseline resolved within 20 min. The method performance was investigated in terms of precision, linearity, sensitivity and accuracy to demonstrate the applicability of the developed capillary electrochromatographic system to forensic analysis. Calibration curves provided a good linearity over a working range of 100–1200 ng/mL for all analytes. Limits of detection and quantification were in the range 5–12 ng/mL and 10–30 ng/mL, respectively. Then the method was applied to the analysis of a human urine sample spiked with a basic compounds’ mixture. Urine samples’ pre-treatment was carried out through a solid phase extraction (SPE) procedure on strong cation exchange (SCX) cartridges.  相似文献   

6.
A new and sensitive method for the determination of norepinephrine (NE), synephrine, and isoproterenol was developed by CE separation and indirect electrochemiluminescence detection (ECL) based on their quenching effects on the tris(2,2'-bipyridyl)-ruthenium(II)/tripropylamine (TPA) system. The conditions for CE separation and ECL detection were investigated in detail. Under the optimum conditions, the three analytes were well separated within 9 min. The LODs (S/N = 3) in standard solution are 2.6 x 10(-8) mol/L for NE, 6.6 x 10(-9) mol/L for synephrine and 8.4 x 10(-8) mol/L for isoproterenol, respectively. The precisions of intraday and interday are less than 4.4 and 6.1%, respectively. The LOQs (S/N = 10) in real human urine samples are 2.6 x 10(-7) mol/L for NE, 8.8 x 10(-8 ) mol/L for synephrine, and 8.8 x 10(-7) mol/L for isoproterenol, respectively. The applicability of the proposed method was illustrated in the determination of 20 human urine samples from diabetic patients and healthy persons. The results obtained indicated that the level of NE in patients (mean value 0.41 micromol/L) was higher than that in healthy persons (mean value 0.24 micromol/L).  相似文献   

7.
Methamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA) were extracted from human urine by using microwave-assisted extraction (MAE) followed by gas chromatography analysis with flame ionization detection. In order to improve the extraction efficiency, experimental parameters on the extraction, including extraction solvent and its volume, pH value of sample, extraction time and temperature were investigated. Under the optimal conditions, the average recoveries of MA, MDA and MDMA were 92.25, 85.94 and 91.50%, respectively. And the intra-day and inter-day relative standard deviations were not greater than 6.9%. The results indicate that the developed method is rapid, accurate and sensitive, and can be used for the simultaneous determination of MA, MDA and MDMA in urine for forensic application.  相似文献   

8.
Fang L  Kang J  Yin XB  Yang X  Wang E 《Electrophoresis》2006,27(22):4516-4522
CE with electrochemiluminescence (ECL) detection technique was successfully applied for the chiral separation of a kind of class IA antiarrhythmic racemic drug. To the best of our knowledge, this is the first report of ECL detection used in chiral CE. To get better detection sensitivity and good enantioresolution at the same time, the conditions of capillary inlet and outlet buffer were systematically optimized. Unlike the traditional chiral separation method, the buffers we used in the capillary inlet and outlet differed from each other in terms of buffer pH, ionic strength, type of BGE as well as buffer composition. Under the optimum conditions, baseline enantioseparation and highly sensitive detection of the enantiomers were achieved. Wide linear relationship of each enantiomer was achieved in the range of 5 x 10(-7) to 2 x 10(-5) mol/L with relative coefficients of 0.996 and 0.997, respectively. The detection limits were estimated to be 8 x 10(-8) and 1.0 x 10(-7) mol/L (S/N = 3) for the enantiomers, respectively. In addition, a successful application of this new method to the chiral separation of the racemic drug in spiked plasma samples confirmed the validity and applicability of the chiral CE-ECL method.  相似文献   

9.
Liu YM  Cao JT  Tian W  Zheng YL 《Electrophoresis》2008,29(15):3207-3212
A novel method for the determination of norfloxacin (NOR) and levofloxacin (LVX) was developed by CE separation and electrochemiluminesence detection (ECL). The methods for capillary conditioning and the effect of solvent type were studied. Parameters affecting the CE and ECL were also investigated. Under the optimum conditions, the two analytes were well separated within 9 min. The LODs (S/N = 3) in standard solution are 4.8 x 10(-7) mol/L for NOR and 6.4 x 10(-7) mol/L for LVX, respectively. The precisions of intraday and interday are less than 4.2 and 8.1%, respectively. The LOQs (S/N = 10) in real human urine samples are 1.2 x 10(-6) mol/L for NOR and 1.4 x 10(-6) mol/L for LVX, respectively. The applicability of the proposed method was illustrated in the determination of NOR and LVX in human urine samples and the monitoring of pharmacokinetics for NOR. The recoveries of NOR and LVX at different levels in human urine samples were between 84.3 and 92.3%.  相似文献   

10.
This paper describes a highly sensitive HPLC method for the simultaneous determination of 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), amphetamine (AP) and methamphetamine (MP) in human hair samples. The amphetamines investigated were derivatized with the fluorescent reagent, DIB-Cl to yield highly fluorescent DIB-derivatives, which were then analyzed by HPLC with fluorescence detection at excitation and emission wavelengths of 325 nm and 430 nm, respectively. The separation was achieved on an ODS column with an isocratic mobile phase composed of acetonitrile-methanol-water (30:40:30, v/v/v). The limits of detection for the four compounds obtained by the proposed method ranged from 11 to 200 pg/mg. The method was successfully applied to the determination of MDMA and MDA in hair samples obtained from MDMA abuser.  相似文献   

11.
Capillary zone electrophoresis was employed for the determination of diclofenac sodium using an end-column amperometric detection with a carbon fiber microelectrode, at a constant potential of 0.83 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 4.90 x 10(-3) mol/l Na2HPO4-3.10 x 10(-3) mol/l NaH2PO4 (pH 7.0) for the buffer solution, 10 kV for the separation voltage, 5 kV and 10 s for the injection voltage and the injection time, respectively. The limit of detection is 2.5 x 10(-6) mol/l or 5.2 fmol (S/N=2). The relative standard deviation is 0.8% for the migration time and 4.7% for the electrophoretic peak current. The method was applied to the determination of diclofenac sodium in human urine.  相似文献   

12.
Monitoring of amphetamines and designer drugs in human urine is a timely topic in clinical toxicology, surveillance of drug substitution, forensic science, drug testing at the workplace, and doping control. Confirmation testing of urinary amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA, Ecstasy) and 3,4-methylenedioxyamphetamine (MDA) by capillary electrophoresis (CE) combined with atmospheric pressure electrospray ionization and ion trap mass spectrometry (MS) is described. Using an aqueous pH 4.6 buffer composed of ammonium acetate/acetic acid, CE-MS and CE-MS2 provided data that permitted the unambiguous confirmation of these drugs in external quality control urines. Furthermore, other drugs of abuse present in alkaline urinary extracts, including methadone and morphine, could also be monitored. The data presented illustrate that the sensitivity achieved with the benchtop MS is comparable to that observed by CE with UV absorption detection. CE-MS2 is further shown to be capable of identifying comigrating compounds, including the comigration of amphetamine with nicotine.  相似文献   

13.
A simple, reliable and reproducible method, based on capillary zone electrophoresis with amperometric detection, has been developed for the determination of idarubicin in human urine. A carbon disk electrode was used as working electrode. The optimal conditions of separation and detection were pH 5.6 phosphate buffer (0.20 mol/L), 22 kV for the separation voltage and 1.00 V (vs. Ag/AgCl, 3 mol/L KCl) for the detection potential. The linear range was from 4.0 x 10(-7) to 2.0 x 10(-5) mol/L with a regression coefficient of 0.9986, and the detection limit was 8.0 x 10(-8) mol/L. The method was directly applied to the determination of idarubicin in spiked human urine without any other sample pretreatment except filtration, and the assay results were satisfactory.  相似文献   

14.
A new ionization method, named surface-activated chemical ionization (SACI), was employed for the analysis of five amphetamines (3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyethylamphetamine (MDE), amphetamine and methamphetamine) by ion trap mass spectrometry. The results so obtained have been compared with those achieved by using atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) using the same instrument, clearly showing that SACI is the most sensitive of the three. The limit of detection and linearity range for SACI were compared with those obtained using APCI and ESI, showing that the new SACI approach provides the best results for both criteria. SACI was used to analyze MDA, MDMA MDE, amphetamine and methamphetamine in four urine samples, and the quantitation results are compared with those achieved using ESI.  相似文献   

15.
Liu J  Yang X  Wang E 《Electrophoresis》2003,24(18):3131-3138
Capillary electrophoresis (CE) with tris(2,2'-bipyridyl) ruthenium (II) (Ru(bpy)3(2+)) electrochemiluminescence (ECL) detection technique was developed for the analysis of four polyamines (putrescine (Put), cadaverine (Cad), spermidine (Spd), and spermine (Spm)) analysis. The four polyamines contain different amine groups, which have different ECL activity. There are several parameters which influence the resolution and ECL peak intensities, including the buffer pH and concentrations, separation voltage, sample injection, electrode materials, and Ru(bpy)3(2+) concentrations. Polyamines are separated by capillary zone electrophoresis in an uncoated fused-silica capillary (50 cmx25 micro m (ID) filled with acidic phosphate buffer (200 mmol/L phosphate, pH 2.0) - 1mol/L phosphoric acid (9:1 v/v) and a separation voltage of 5 kV (25 micro A), with end-column Ru(bpy)3(2+) ECL detection. A 5 mmol/L Ru(bpy)3(2+) solution plus 200 mmol/L phosphate buffer (pH 11.0) is added into the reagent reservoir. The calibration curve is linear over a concentration range of two or three orders of magnitude for the polyamines. The analysis time is less than 25 min. Detection limits for Put and Cad are 1.9x10(-7) mol/L and 7.6x10(-9) mol/L for Spd and Spm, respectively. Intraday and interday relative standard deviations of ECL peak intensities are less than 8%. The main advantages of this CE-ECL detection technique for polyamines analysis presented herein are the omission of chemical derivatization of the analytes and the high selectivity.  相似文献   

16.
Cao W  Liu J  Yang X  Wang E 《Electrophoresis》2002,23(21):3683-3691
A new end-column electrochemiluminescence (ECL) detection technique coupling to capillary electrophoresis (CE) is characterized. A 300 microm diameter Pt working electrode was used to directly couple with a 75 microm inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy) 3 2+ showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy) 3 2+ in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 microm capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 220-260 microm. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 microm capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 x 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 x 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-8) mol/L.  相似文献   

17.
A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d5 was used as an internal standard. The linear ranges were 0.01-5.0 μg mL−1 for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 μg mL−1 for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation ≧0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 μg mL−1 of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio ≧ 3) in urine was 5 ng mL−1 for MA and MDMA and 10 ng mL−1 for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation.  相似文献   

18.
An electrogenerated chemiluminescence (ECL) method for the determination of pethidine, atropine, homatropine and cocaine is described. The optimum conditions were found to be similar for all of these compounds although the ECL emission intensity for cocaine was an order of magnitude lower than for pethidine due to their different chemical structures. Linear calibrations were obtained for all the compounds at pH 10 in borate buffer (0.05 mol l-1) at 1.3 V. Limits of detection of 6.8 x 10(-8), 2.2 x 10(-7), 3.2 x 10(-7) and 6.5 x 10(-7) mol l-1, respectively, were achieved for pethidine, atropine, homatropine and cocaine in standard solutions. Solid-phase extraction was used to separate the drugs from their matrix and the method was applied to the determination of spiked urine samples. The limits of quantitation for pethidine, atropine, homatropine and cocaine in urine were 1.0 x 10(-6), 2.0 x 10(-6), 2.0 x 10(-6) and 4.0 x 10(-6) mol l-1, respectively, with recoveries of between 90 and 110%.  相似文献   

19.
A novel and sensitive method for the simultaneous determination of enoxacin and ofloxacin has been established using capillary electrophoresis (CE) coupled with electrochemiluminescence (ECL) detection based on the ECL enhancement of tri(2,2‐bipyridyl)ruthenium(II). The conditions for sample solvent type, CE separation and ECL detection were investigated systematically. The analytes were well separated and detected within 7 min. The limits of detection (S/N = 3) of enoxacin and ofloxacin are 9.0 × 10?9 and 1.6 × 10?8 mol/L, respectively. The precisions (RSD%) of intraday and interday are less than 2.1 and 4.0%, respectively. The limits of quantitation (S/N = 10) of enoxacin and ofloxacin are 3.2 × 10?7 and 5.4 × 10?7 mol/L in human urine samples and 4.1 × 10?7 and 6.9 × 10?7 mol/L in human serum samples, respectively. The recoveries of enoxacin and ofloxacin at different concentration levels in human urine, serum and eye drop samples are between 94.0 and 106.7%. The proposed method was successfully applied to the determination of the enoxacin and ofloxacin in human urine, serum and eye drop samples and the monitoring of pharmacokinetics of ofloxacin in human body. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
M Jin  Q Dong  R Dong  W Jin 《Electrophoresis》2001,22(13):2793-2796
Capillary zone electrophoresis was employed for the determination of pyruvate in human sweat using electrochemical detection with a carbon fiber microdisk bundle electrode at a constant potential of 1.60 V vs. saturated calomel electrode. The optimum separation conditions are 3.6 x 10(-3) mol/L Na2HPO4-1.4 x 10(-3) mol/L NaH2PO4 (pH 7.2) for the buffer solution, and 18 kV for the separation voltage. The limits of detection of pyruvate are 8.0 x 10(-6) mol/L or 24 fmol (S/N = 3) for the injection voltage of 6 kV and the injection time of 10 s. The relative standard deviation is 2.0% for the migration time and 5.7% for the electrophoretic peak current. The method was applied to determining pyruvate in human sweat.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号