首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Micellar electrokinetic capillary chromatography (MECC) based on sodium cholate (NaCh) and sodium dodecyl sulphate (SDS) was developed for the determination of aromatic amino acids and heterocyclic legume constituents. The influence of temperature, voltage, micellar system, pH, zwitterion and modifier concentrations in the buffer on migration times, peak areas, resolution and number of theoretical plates was investigated. This MECC method makes possible the sensitive determination of the individual compounds with detection limits in the picomole range. Up to 300 000 theoretical plates per metre of capillary were obtained together with satisfactory linearity and repeatability of the NaCh method. The applicability of MECC to samples prepared from plant material, following a fast and simple technique of isolation, purification and group separation, is illustrated by selected examples.  相似文献   

2.
Zhou XM  Liu JW  Zhang ME  Chen SJ 《Talanta》1998,46(4):757-760
The micellar electrokinetic capillary chromatography (MECC) method is reported for the separation of heparin, and for the possibility of direct determination of free heparin in plasma. The conditions for MECC were: pH 8.5, 25 mM sodium dodecyl sulfate (SDS), 25 mM borate buffer, with a 30 cmx50 mum ID fused-silica capillary. The sample was detected with a UV-detector at 270 nm with heparin as external standard. The recovery rate was 95.6-98.7%. This method was linear in the range 80-7000 U l(-1). The within-run and between-run relative standard deviations were lower than 3.1 and 4.5%, respectively. It is suggested that this MECC method may be used to determine blood samples containing high levels of heparin.  相似文献   

3.
Fung YS  Mak JL 《Electrophoresis》2001,22(11):2260-2269
A new analytical procedure using a two-step sample preconcentration (solid-phase extraction (SPE) and field-amplified sample stacking) prior to separation by micellar electrokinetic capillary chromatography was developed for the determination of 14 pesticides such as aldicarb, carbofuran, isoproturon, chlorotoluron, metolachlor, mecoprop, dichlorprop, MCPA, 2,4-D, methoxychlor, TDE, DDT, dieldrin, and DDE in drinking water. Good recoveries of pesticides were obtained using SPE with sample pH adjusted to 2-3. Field-amplified sample stacking was found to give enrichment factors up to 30-fold preconcentration of various pesticides under reversed polarity at -2 kV for 50 s. The optimized background electrolyte (BGE) consisted of 50 mM sodium dodecyl sulfate (SDS), 10 mM borate buffer, 15 mM beta-cyclodextrin (beta-CD), and 22% acetonitrile at pH 9.6, running was under 25 kV and detection at 202 nm. Good linearity was obtained for all pesticides with detection limits down to 0.04-0.46 ng/mL and a working range of 0.1-40 ng/mL. The repeatabilities of migration time and peak area were satisfactory with relative standard deviations (RSDs) between 0.66 and 13.6% and 4.1 and 28%, respectively. All pesticides except dieldrin were found to be detected at concentrations at least tenfold lower than the World Health Organization (WHO) guideline values. The analytical procedure developed offers an economic method for fast screening of multiple pesticide residues in drinking water for health protection. It had been applied to determine carbofuran and MCPA in agricultural run-off water samples, giving satisfactory repeatabilities of 10 and 12%, respectively, with n=5 for the determination of pesticides in contaminated water samples.  相似文献   

4.
A fast and simple micellar electrokinetic capillary chromatographic method was developed for the analysis of piribedil in pharmaceutical formulations. The effects of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, applied voltage and injection time were investigated. Optimum results were obtained with a 50 mM borate buffer at pH 8.0 containing 50 mM SDS by using a fused silica capillary (50 m internal diameter, 72 cm effective length). The sample was injected hydrodynamically for 4 s at 50 mbar pressure and the applied voltage was +30 kV. The detection wavelength was set at 205 nm. Diflunisal was used as an internal standard. The analysis was performed at 25 °C and the total run time was 14 min. The method was suitably validated with respect to linearity range, limit of detection and quantification, precision, accuracy, specificity and robustness. The linear calibration range was 5–100 g mL–1 and the limit of detection was determined as 1 g mL–1. The method developed was successfully applied to the determination of piribedil in pharmaceutical formulations. The results were compared with a spectrophotometric method reported in the literature and no significant difference was found statistically.  相似文献   

5.
胶束电动毛细管色谱法测定植物中的水杨酸   总被引:2,自引:1,他引:2  
建立了以胶束电动色谱为分离模式测定植物中水杨酸的新方法。在一定范围内,随着硼酸和甲醇浓度的升高,苯甲酸内标和水杨酸的分离度以近似线性关系升高;随缓冲液pH的升高分离度呈非线性升高;随十六烷基三甲基溴化铵浓度的升高分离度呈非线性下降。在优化的条件下,两可在12min内分离。测定了苹果和梨样品,并做了回收率试验,回收率在97.1%-102%之间。  相似文献   

6.
Pesticide analysis by micellar electrokinetic capillary chromatography   总被引:2,自引:0,他引:2  
On-capillary sample concentration using sample stacking for the improvement of detection limits for various pesticides separated by micellar electrokinetic capillary chromatography was examined. The dependence of the stacking on different parameters was investigated. An approximately 30-fold preconcentration was achieved by applying sample stacking. Employing a two-step enrichment process (solid-phase extraction combined with sample stacking), detection limits were improved and the sample volume for SPE was reduced. In addition, the total time for the analysis was considerably reduced. Detection limits were between 0.01 and 0.1 ng/ml under these enrichment conditions.  相似文献   

7.
A method based on micellar electrokinetic capillary chromatography (MECC) has been developed for the determination of shikimate in water and crude plant extracts. The analytes are separated in a cholate-taurine buffer by MECC at pH 7.3 and measured by direct UV detection at 206 nm. Shikimate showed linearity up to 12.5 mM, with a squared correlation coefficient (r(2)) of 0.9997. The method has concentration limit of detection (cLOD) and concentration limit of quantification (cLOQ) at 24.4 and 67.8 microM, respectively, corresponding to detection in the femtomol range. The number of theoretical plates (N) was estimated to 245,000 for the optimized system using a capillary with an effective length of 560 mm. The method was tested on plant samples by measuring the shikimate content in leaves of rapeseed plants grown in hydroponic solutions containing the herbicide glyphosate, a well-known inhibitor of the shikimate pathway. In crude extracts of these plants, shikimate was found to accumulate in the leaves, confirming earlier reports of shikimate as a potential biomarker for glyphosate treatment. The method now developed was also able to detect shikimate-3-phosphate, but this compound was not accumulated in glyphosate inhibited plants as found for shikimate.  相似文献   

8.
《Analytica chimica acta》2004,519(1):65-71
The separation and determination of two s-triazines and two quats in water samples by MEKC was described. The influence of pH, type and concentration of buffer, concentration and type of surfactant, organic modifier and the added salt on the separation of the two neutral and the two cationic herbicides was studied. Simazine and atrazine (neutral compounds at the working pH) were little influenced by the chemical variables, while the cationic paraquat and diquat were more influenced. In the optimisation on the separation voltage, the total concentration of salt in the run buffer and the repeatability of the separation were taken into consideration. The composition of dissolution, in which the analytes were dissolved, was also studied.A solid-phase extraction method to retain and to elute the four analytes in a single step was also developed. Recoveries between 80 and 95% and R.S.D. between 6 and 10% was obtained in the analysis of a well-water sample spiked with 2 and 5 ppb of triazines and quats, respectively. Detection limits were between 0.6 and 1.9 ppb.  相似文献   

9.
Micellar electrokinetic capillary chromatography (MEKC) was performed at 25 °C and 30 kV (under a pressure of 15 mbar), using 30 mM borate buffer containing 60 mM sodium dodecysulfate (SDS) and 5% (v/v) methanol as background electrolyte (pH 9.0) to determine doxycycline. UV detection was at 350 nm. The method was shown to be specific, accurate (recovery was 100.3 ± 1.0%), linear over the tested range (correlation coefficient 0.9995) and precise (RSD <1.9%). The method was used to determine doxycycline in tablets, capsules and human urine after oral application.  相似文献   

10.
A new micellar electrokinetic capillary chromatography method (MEKC) is proposed for the determination of ibuprofen and tetrazepam in human urine samples over a concentration range of therapeutic interest. A fused silica capillary (60 cm × 75 μm) is used. Ibuprofen and tetrazepam are detected via UV detection at 220 and 228 nm, respectively. Separation is performed at 25 °C and at a separation voltage of 30 kV, with 15 mM borate buffer (pH 10.2) containing 40 mM sodium dodecylsulfate as the electrolyte solution. Under these conditions the analytes were separated in <11 min. Sulfamethazine is used as an internal standard. Prior to determination, the samples are purified and enriched by means of an extraction–preconcentration step with a preconditioned C18 cartridge and by eluting the compounds with methanol. Good linearity, accuracy, precision, robustness and solution stability were achieved for the technique. Detection limits of 200 μg L−1 for ibuprofen and 300 μg L−1 for tetrazepam were obtained. These analytes were then determined in real urine using the technique.  相似文献   

11.
Separation of coumarins by micellar electrokinetic capillary chromatography   总被引:10,自引:0,他引:10  
Nine coumarins were successfully separated simultaneously using micellar electrokinetic capillary chromatography with 4-hydroxybenzoic acid as an internal standard. A carrier composed of buffer solution (20 mM sodium dodecyl sulfate-15 mM sodium borate-15 mM sodium dihydrogenphosphate)-acetonitrile (24:1) was found to be the most suitable electrolyte for this separation. The analysis time (22 min) was shorter than that using high-performance liquid chromatography (47 min). Contents of coumarins in the crude drug of Angelicae Tuhou Radix could be easily determined by the proposed method.  相似文献   

12.
13.
A method for the determination of isoniazid (ISO), pyrazinamide (PYR) and rifampicin (RIF) in pharmaceutical products, by micellar electrokinetic capillary chromatography (MEKC) with ultraviolet detection is described. The influence of pH, concentration of surfactants, buffer and organic solvents, over the separation were studied as experimental variables. The optimal separation was carried out at 30 degrees C and 20 kV, using a 40 mM borate buffer and 100 mM sodium dodecylsulphate (SDS) adjusted to pH 8.5. Under these conditions, the analysis is accomplished in about 8 min. The method was applied to the determination of these compounds in different pharmaceuticals with good results when compared with a reference liquid chromatographic (LC) method.  相似文献   

14.
Shihabi ZK  Hinsdale ME 《Electrophoresis》2006,27(12):2458-2463
A simple and rapid ( approximately 4 min) method for the measurement of iohexol in serum for assessing the glomerular filtration rate is described. It is based on direct serum injection on the capillary by MEKC. The method is linear between 8 and 260 mg/L, with an RSD of peak height of 2.9%. Several simple steps have contributed to an improved daily precision, such as choosing a high pH buffer, increasing the SDS concentration, frequent standardization, and eliminating any sample pretreatment.  相似文献   

15.
《Analytica chimica acta》2004,503(2):271-278
In this work, a capillary electrophoresis (CE) method for the determination of a group of eleven triazine compounds by micellar electrokinetic capillary chromatography (MEKC) with diode array detection was developed. The eleven herbicides studied were: desethylatrazin-2-hydroxy (DEA), simazine, prometon, atrazine, simetryn, ametryn, propazine, prometryn, trietazine, terbutylazine, and terbutryn The separation of these compounds was optimised as a function of buffer concentration and pH, concentration of sodium dodecyl sulphate (SDS) and voltage applied. To increase the selectivity of the separation and the resolution of the solutes, different organic solvents were tested as buffer additives, obtaining the best results when 1-propanol was used. The optimised buffer (24 mM of sodium borate, 18 mM of disodium hydrogen phosphate, 25 mM of SDS, pH 9.5, and 5% of 1-propanol) provides the best separation in terms of resolution and migration time. This method allowed the determination of these compounds at concentrations of 0.05 μg l−1 in ground water samples pretreated using solid-phase extraction (SPE).  相似文献   

16.
Guan Y  Chu Q  Fu L  Ye J 《Journal of chromatography. A》2005,1074(1-2):201-204
A new and efficient method for the determination of antioxidants [Propyl gallate (PG), tert-butylhydroquinone (TBHQ), butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT)] in cosmetics has been established by using micellar electrokinetic capillary chromatography with electrochemical detection (MECC-ED). Under the optimum conditions of the method, all analytes were successfully separated within 13 min at the separation voltage of 18 kV in a 20 mmol/L borate running buffer (pH 7.4) containing 25 mmol/L sodium dodecyl sulfate. The excellent linearity was obtained in the concentration range from 5.0 x 10(-4) to 2.0 x 10(-6) mol/L and the detection limits (S/N = 3) of PG, TBHQ, BHA, and BHT range from 3 x 10(-7) to 3 x 10(-6) mol/L.  相似文献   

17.
胶束电动毛细管色谱法检测红曲米中的莫纳可林K   总被引:2,自引:1,他引:2  
张良  许杨  李燕萍 《色谱》2010,28(4):393-396
建立了测定红曲米中莫纳可林K含量的胶束电动毛细管色谱(MEKC)方法。考察了运行缓冲液的种类、pH及其浓度、有机添加剂、十二烷基硫酸钠(SDS)的浓度和分离电压等实验条件对电泳分离效果及检测灵敏度的影响。在优化的实验条件下,以20 mmol/L硼砂(pH 10.6,含10%(体积分数)乙醇和40 mmol/L SDS)作为缓冲溶液,莫纳可林K能在23 min内实现很好的基线分离,线性范围为5.00~100.00 mg/L,线性相关系数为0.9976,检出限(以信噪比(S/N)为3计)为0.13 mg/L,加标回收率为98.5%~99.5%。精密度和稳定性试验中,峰面积和迁移时间的相对标准偏差均小于3%,表明重复性良好。该方法简便、快速、灵敏,可用于红曲米中莫纳可林K含量的测定。  相似文献   

18.
Micellar electrokinetic capillary chromatography (MEKC) has been developed as a promising method for the determination of lignans in plant samples. The separation conditions have been optimized with respect to the different parameters including sodium dodecyl sulfate (SDS) and acetonitrile concentration, pH of the background electrolyte, separation voltage, and capillary temperature. The background electrolyte consisting of 40 mM SDS and 35% acetonitrile in 10 mM tetraborate buffer (pH 9.3) was found to be the most suitable electrolyte for this analysis. The applied voltage of 28 kV (positive polarity) and the capillary temperature 25 degrees C gave the best separation of lignans. The interday reproducibility of the peak areas and the migration times was below 2.0%. The results of MEKC analyses were compared with those obtained by capillary electrochromatography (CEC) and reversed-phase high-performance liquid chromatography (RP-HPLC). The possibilities of using this method for the determination of lignans in drug and in serum samples were also tested.  相似文献   

19.
Summary Computer-assisted procedures for the one-parameter optimization of the surfactant concentration and the concentration of urea or D-glucose as modifiers in micellar electrokinetic capillary chromatography have been developed. These procedures permit a rapid optimization of one parameter on the basis of only two experiments. Predicted values are compared to empirically obtained optimum values. The influence of the modifier concentration on the critical micelle concentration of sodium dodecyl sulfate was experimentally determined in buffers commonly employed in micellar electrokinetic chromatography. The alteration of retention factors of solutes caused by the influence of urea addition on the critical micelle concentration of sodium dodecyl sulfate was calculated under the assumption of constant distribution coefficients and compared to experimentally obtained values. It was demonstrated that the addition of urea or of D-glucose does not alter the phase ratio substantially.  相似文献   

20.
A simple and reliable method for determination of quercetin glycosides and free quercetin in buckwheat flower, leaves, stems and achenes was developed. The method consists of flavonoid extraction from freeze‐dried homogenous material in 50% v/v methanol solution and in presence of an antioxidant, cleaning of extract and analyte isolation using SPE. Analytical step uses capillary micellar electrokinetic chromatography. The working ranges, LOD and LOQ, recovery, precision and measurement uncertainty were calculated. The method is suitable for samples from buckwheat. The highest content of rutin was found in flowers of both kinds of buckwheat (99 400 mg/kg in F. esculentum, 108 000 mg/kg in F. tataricum). The free quercetin occurs in flowers and achenes of F. esculentum, whereas flowers and achenes of F. tataricum contained quercitrin.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号