首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A novel matrix of isoliquiritigenin (ISL), a flavonoid with a chalcone structure (4,2′,4′-trihydroxychalcone), was demonstrated to be advantageous in the analysis of neutral oligosaccharides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). With ISL as a matrix, adequate signal for an analyte can be obtained in much lower matrix concentrations and laser intensity compared to commonly used MALDI matrices. Four different sample preparation methods were tested, and the dried droplet method exhibited the best performance on MALDI-TOF-MS analysis of oligosaccharides with ISL as a matrix. For the analysis of carbohydrates, compared with popular matrices such as 2,5-dihydroxybenzoic acid (DHB) and 2,4,6-trihydroxyacetophenone (THAP), ISL exhibited outstanding matrix properties as follows: (1) higher homogeneity of crystallization thus allowing automatic data acquisition, (2) better spectral quality in terms of resolution and signal to noise ratio (S N−1), (3) better salt tolerance, (4) higher sensitivity, and (5) enough fragmentation yield to use LIFT-TOF/TOF MS to get richer structural information. In addition, reliable quantitative analysis of oligosaccharides with a good linearity over two concentration orders (1–100 pmol μL−1) and good reproducibility of the signal intensity (RSD less than 15%) were achieved using this matrix. These results give a new outlook on high-speed analysis of neutral carbohydrates by MALDI-TOF MS.  相似文献   

2.
Neutral and acidic oligosaccharides from human milk were analyzed by matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS). These experiments require suitable matrices; their selection and particularly their preparation protocols must be optimized. Important criteria are sensitivity, reproducibility, tolerance against impurities and resolution over a wide mass range. For analytical investigations of these oligosaccharides, containing labile fucosylated and sialylated components, another property of a matrix becomes a significant factor, namely the influence on ion stability and the extent of (metastable) fragmentation. The experience gained with the MALDI/MS of neutral and acidic oligosaccharides is summarized taking into account different intentions of measurement and typical problems, such as impurities after enzymatic treatment. For a rapid screening of an oligosaccharide sample, superior results were obtained with a new preparation technique using 5-chloro-2-mercaptobenzothiazole (CMBT) as the first layer for 2,5-dihydroxybenzoic acid. For structural analysis by post-source decay, CMBT as the first layer for 3-aminoquinoline is a favoured preparation protocol, because extensive fragmentation is achieved. For acidic oligosaccharides, a special preparation protocol makes it possible to determine the number of sialic acids by inducing highly effective cationization. Matrix-assisted laser desorption/ionization mass spectrometry; matrices; oligosaccharides; post-source decay.  相似文献   

3.
Compared to other analytical methods, matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) presents several unique advantages for the structural characterization of degradation products of carbohydrates. Our final goal is to implement this technique as a high-throughput platform, with the aim of exploring natural bio-diversity to discover new carbohydrate depolymerizing enzymes. In this approach, a variety of carbohydrates will be used as enzymes substrates and MALDI-MS will be employed to monitor the oligosaccharides produced. One drawback of MALDI, however, is that the choice of the matrix is largely dependent on the chemical properties of the analyte. In this context, our objective in the present work was to find the smallest set of MALDI matrices able to detect chemically heterogeneous oligosaccharides. This was done through the performance evaluation of more than 40 MALDI matrices preparations. Homogeneity of analyte-matrix deposits was considered as a critical feature, especially since the final objective is to fully automate the analyses. Evaluation of the matrices was done by means of a rigorous statistical approach. Amongst all tested compounds, our work proposes the use of the DHB/DMA ionic matrix as the most generic matrix, for rapid detection of a variety of polysaccharides including neutral, anionic, methylated, sulfated, and acetylated compounds. The selected matrices were then used to screen crude bacterial incubation media for the detection of enzymatic degradation products.  相似文献   

4.
So far, there have been only a few matrices reported for detection of polysaccharides with molecular weight higher than 3000 Daltons by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). In this work, we found that 2',4',6'-trihydroxyacetophenone (THAP) is a good matrix for MALDI time-of-flight MS analysis of polysaccharides with broad mass range. Large polysaccharides, dextrans, glycoproteins and polysialic acids have been successfully detected by MALDI-MS with THAP as matrix.  相似文献   

5.
A sample preparation method that is suitable for sensitive detection of underivatized oligosaccharides by matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) has been investigated. As compared with the conventional dried‐droplet or ethanol (EtOH) recrystallization method, superior mass spectra in terms of ion yield and signal‐to‐noise (s/n) ratio were obtained when methanol (MeOH) was used as a solvent for the mixture of matrix and oligosaccharides. Based on these results, a new sample preparation method, named the ‘reverse thin layer method’, was developed. This method comprises two steps: first, complete drying of the oligosaccharide solution on the MALDI target plate; and second, deposition of the matrix dissolved in a small amount of MeOH. Using this method, a relatively homogeneous matrix crystal was generated and higher yields of both positive and negative ions were obtained from oligosaccharides compared with conventional methods. Notably, the method can be applied to various matrices including both solid and liquid matrices. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
This study demonstrates the application of 2,5-dihydrohybenzoic acid/aniline (DHB/An) and 2,5-dihydroxybenzoic acid/N,N-dimethylaniline (DHB/DMA) matrices for automated identification and quantitative analysis of native oligosaccharides by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Both matrices are shown to be superior to pure DHB for native glycans in terms of signal intensities of analytes and homogeneity of sample distribution throughout the crystal layer. On-target formation of stable aniline Schiff base derivatives of glycans in DHB/An and the complete absence of such products in the mass spectra acquired in DHB/DMA matrix provide a platform for automated identification of reducing oligosaccharides in the MALDI mass spectra of complex samples. The study also shows how enhanced sensitivity is achieved with the use of these matrices and how the homogeneity of deposited sample material may be exploited for quick and accurate quantitative analysis of native glycan mixtures containing neutral and sialylated oligosaccharides in the low-nanogram to mid-picogram range.  相似文献   

7.
Highly efficient separation techniques, laser-induced fluorescence (LIF) detection, and different mass-spectrometric (MS) measurements were combined in a multimethodological scheme to perform a comprehensive structural characterization of N-linked oligosaccharides in a murine monoclonal antibody (immunoglobulin G (IgG(kappa))). Monosaccharide compositional analysis was carried out through a capillary electrophoresis (CE)-LIF method, in which the chemically and enzymatically released sugars were fluorescently labeled. This analysis provides a preliminary assessment of certain structures, being followed by CE-LIF and matrix-assisted laser desorption/ionization (MALDI)-MS profiling of the intact glycan structures. Linkages and monosaccharide residues were confirmed by MALDI-MS in conjunction with exoglycosidase digestion. MALDI-MS and CE data were effectively combined to reveal the overall structural diversity of both acidic and neutral glycans. Finally, the sites of glycosylation and site occupancies were deduced through the measurements performed with microcolumn liquid chromatography coupled via electrospray to a quadrupole/time-of-flight instrument.  相似文献   

8.
Mass spectrometry is widely applied in carbohydrate analysis, but still quantitative evaluation of data is critical due to different ionization efficiencies of the constituents in a mixture. Different size and chemical structure of the analytes cause their uneven distribution in droplets (electrospray ionization, ESI) or matrix spots (matrix-assisted laser desorption/ionization, MALDI). In addition, instrumental parameters affect final ion yields. In order to study and optimize the latter, an equimolar mixture of malto-oligosaccharides (DP1-6) was analyzed using varying target masses for ESI as well as different matrices and laser power for MALDI. The sodium adducts and derivatives for positive ion mode (hydrazones with Girard's T Reagent, GT) and negative ion mode (reductively aminated with o-aminobenzoic acid, oABA) were studied. Negatively charged oABA-labeled malto-oligosaccharides turned out to be unsuitable for quantification of the malto-oligomeric composition. Best agreement was achieved when applying target masses in the range of the highest homolog in the mixture in electrospray ionization ion trap (ESI-IT) (1-2% deviation with GT label or as Na(+) adducts). Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) gave best results when the laser power was adjusted significantly over the desorption/ionization threshold (1% deviation with GT label). Both parameters show significant influence on the determined oligomeric composition. Consequently, estimation and even quantitative determination of amounts of oligosaccharides in a mixture can be achieved when the analytes are labeled and the proper instrumental parameters are used.  相似文献   

9.
Matrix-enhanced surface-assisted laser desorption ionization mass spectrometry imaging (ME-SALDI MSI) has been previously demonstrated as a viable approach to improving MS imaging sensitivity. We describe here the employment of ionic matrices to replace conventional MALDI matrices as the coating layer with the aims of reducing analyte redistribution during sample preparation and improving matrix vacuum stability during imaging. In this study, CHCA/ANI (α-cyano-4-hydroxycinnamic acid/aniline) was deposited atop tissue samples through sublimation to eliminate redistribution of analytes of interest on the tissue surface. The resulting film was visually homogeneous under an optical microscope. Excellent vacuum stability of the ionic matrix was quantitatively compared with the conventional matrix. The subsequently improved ionization efficiency of the analytes over traditional MALDI was demonstrated. The benefits of using the ionic matrix in MS imaging were apparent in the analysis of garlic tissue sections in the ME-SALDI MSI mode.  相似文献   

10.
Single-cell cytoplasm sap (1-10 pL) was extracted by using a pressure probe glass microcapillary tip from tulip leaf and bulb and analyzed by UV-MALDI-TOF MS for free underivatized carbohydrate content. Three matrices including 2,5-dihydroxybenzoic acid (DHB), 2,4,6-trihydroxyacetophenone (THAP), and carbon nanotubes (CNTs) in positive ion mode were selected for analysis because of acceptable carbohydrate-related signal reproducibility. Disaccharide and oligosaccharide (up to 15 Hex when THAP was used, 11 Hex with DHB, and 7 Hex with CNTs) were detected in tulip bulb cell cytoplasm sample. When DHB was used as matrix, neutral carbohydrates were more abundantly detected as sodiated cations; the sugar-related signals, however, appeared as dominant potassiated cations when THAP and CNTs were used. Small amount of monosaccharide was also detected in bulb cell cytoplasm with CNTs as matrix. UV-MALDI-TOF MS of leaf cell extract resulted in high-resolution detection of hexose and disaccharide with DHB, THAP, and CNTs.  相似文献   

11.
An atmospheric pressure (AP) infrared (IR) laser ionization technique, implemented on a quadrupole ion trap mass spectrometer, was used to analyze underivatized, N-linked oligosaccharides in solution. Experiments were conducted on an atmospheric pressure infrared ionization from solution (AP-IRIS) ion source which differed from previous AP IR matrix-assisted laser desorption/ionization (MALDI) interfaces in that the ion source operated in the absence of an extraction electric field with a higher power 2.94 microm IR laser. The general term 'IRIS' is used as the mechanism of ionization differs from that of MALDI, and is yet to be fully elucidated. The AP-IRIS ion source demonstrated femtomole-level sensitivity for branched oligosaccharides. AP-IRIS showed approximately 16 times improved sensitivity for oligomannose-6 and the core-fucosylated glycan M3N2F over optimal results obtainable on a AP UV-MALDI with a 2,4,6-trihydroxyacetophenone matrix. Comparison between IR and UV cases also showed less fragmentation in the IR spectrum for a glycan with a conserved trimannosyl core, core-substituted with fucose. A mixture of complex, high-mannose and sialylated glycans resulted in positive ion mass spectra with molecular ion peaks for each sugar. Tandem mass spectrometry of the sodiated molecular ions in a mixture of glycans revealed primarily glycosidic (B, Y) cleavages. The reported results show the practical utility of AP-IRIS while the ionization mechanism is still under investigation.  相似文献   

12.
Oligosaccharides represent complex class of analytes for mass spectrometric analysis due to the high variety of structural isomers concerning glycosidic linkages and possible branching. A systematic study of the negative ion mode matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry of various neutral oligosaccharides under selection of an appropriate matrix, like 2,5‐dihydroxyacetophenone (2,5‐DHAP) is reported here, without commonly used anion dopant strategies. Nevertheless, we were able to generate relevant in‐source decay (ISD) cross‐ring fragment ions, typically obtained in the negative ion mode. Data observed indicate that the intrinsic property of the terminal non‐reduced aldose is crucial for this behavior. A systematic study of the post source decay (PSD) of molecular, pseudomolecular and ISD cross‐ring cleavage precursor ions is reported here. A direct comparison of the positive and negative ion mode MALDI MS1 and PSD behavior of neutral oligosaccharides could also be performed under the use of the same matrix preparation, because 2,5‐DHAP is fully compatible with positive ion mode acquisition. We found that PSD spectra of deprotonated neutral oligosaccharides obtained in the negative ion mode are richer, because they contained both glycosidic and cross‐ring fragment ions. However, we also found that cross‐ring fragment ions are readily produced in the positive ion mode when potassiated precursor ions were selected. In addition, we show evidence that non‐anionic dopants and specific instrumental parameters can also significantly influence the ISD fragmentation. Taken together, our results should increase our understanding of oligosaccharide behavior in the negative ion mode as well as increase our knowledge regarding many aspects of in‐source MALDI chemistry. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
A new multifunctional oligosaccharide label with a 1 degree amino-group was synthesized and characterized. The oligosaccharide label was introduced into several neutral oligosaccharides by reductive amination, and the derivatives were analyzed by matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) and by electrospray ionization (ESI) mass spectrometry. It was demonstrated that the labeling reaction was satisfactory, and that as little as 50 pmol of starting material could be efficiently labeled with minimal loss to side reactions. A mixture of high-mannose N-glycans released from ribonuclease B was labeled. The label did not appear to interfere with structural characterization of the oligosaccharides by mass spectrometry. N-quaternization of the labeled oligosaccharides resulted in significantly increased sensitivity of detection with as little as 100 fmol on the probe detected. Deuterium coding of labeled oligosaccharide mixtures and relative abundance of mixture components was investigated. A protocol for the chromatographic separation of mixtures of labeled oligosaccharides by HPLC was developed and is reported here.  相似文献   

14.
Nitrous acid degradation of heparin followed by high-performance anion-exchange chromatography (HPAEC) separation and ultraviolet matrix assisted laser desorption/ionization time-of-flight (UV-MALDI-TOF) analysis led to the structural determination of six sulfated oligosaccharides. Three different matrices (α-cyano-4-hydroxycinnamic acid (CHCA), nor-harmane, and dihydroxybenzoic acid (DHB)) have been used, and the complementary results obtained allowed in most cases to assign the position of sulfate groups. Based on the different cleavages produced on the purified oligosaccharides in source during the MS analysis by the use of the different matrices, this approach provides a new tool for structural analysis.  相似文献   

15.
Chloride anion attachment has previously been shown to aid determination of saccharide anomeric configuration and generation of linkage information in negative ion post-source decay MALDI tandem mass spectrometry. Here, we employ electron detachment dissociation (EDD) and collision activated dissociation (CAD) for the structural characterization of underivatized oligosaccharides bearing a chloride ion adduct. Both neutral and sialylated oligosaccharides are examined, including maltoheptaose, an asialo biantennary glycan (NA2), disialylacto-N-tetraose (DSLNT), and two LS tetrasaccharides (LSTa and LSTb). Gas-phase chloride-adducted species are generated by negative ion mode electrospray ionization. EDD and CAD spectra of chloride-adducted oligosaccharides are compared to the corresponding spectra for doubly deprotonated species not containing a chloride anion to assess the role of chloride adduction in the stimulation of alternative fragmentation pathways and altered charge locations allowing detection of additional product ions. In all cases, EDD of singly chloridated and singly deprotonated species resulted in an increase in observed cross-ring cleavages, which are essential to providing saccharide linkage information. Glycosidic cleavages also increased in EDD of chloride-adducted oligosaccharides to reveal complementary structural information compared to traditional (non-chloride-assisted) EDD and CAD. Results indicate that chloride adduction is of interest in alternative anion activation methods such as EDD for oligosaccharide structural characterization.  相似文献   

16.
Matrix-assisted laser desorption/ionization hyphenated with quadrupole time-of-flight (QTOF) mass spectrometry (MS) has been used to directly determine the distribution of pharmaceuticals in rat brain tissue slices which might unravel their disposition for new drug development. Clozapine, an antipsychotic drug, and norclozapine were used as model compounds to investigate fundamental parameters such as matrix and solvent effects and irradiance dependence on MALDI intensity but also to address the issues with direct tissue imaging MS technique such as (1) uniform coating by the matrix, (2) linearity of MALDI signals, and (3) redistribution of surface analytes. The tissue sections were coated with various matrices on MALDI plates by airspray deposition prior to MS detection. MALDI signals of analytes were detected by monitoring the dissociation of the individual protonated molecules to their predominant MS/MS product ions. The matrices were chosen for tissue applications based on their ability to form a homogeneous coating of dense crystals and to yield greater sensitivity. Images revealing the spatial localization in tissue sections using MALDI-QTOF following a direct infusion of (3)H-clozapine into rat brain were found to be in good correlation with those using a radioautographic approach. The density of clozapine and its major metabolites from whole brain homogenates was further confirmed using fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) procedures.  相似文献   

17.
We report the development of a new AP visible-wavelength MALDI-ion trap-MS instrument with significantly improved performance over our previously reported system (Int. J. Mass Spectrom. 315, 66–73 (2012)). A Nd:YAG pulsed laser emitting light at 532 nm was used to desorb and ionize oligosaccharides and peptides in transmission geometry through a glass slide. Limits of detection (LODs) achieved in MS mode correspond to picomole quantities of oligosaccharides and femtomole quantities of peptides. Tandem MS (MS/MS) experiments enabled identification of enzymatically digested proteins and oligosaccharides by comparison of MS/MS spectra with data found in protein and glycan databases. Moreover, the softness of ionization, LODs, and fragmentation spectra of biomolecules by AP visible-wavelength MALDI-MS were compared to those obtained by AP UV MALDI-MS using a Nd:YAG laser emitting light at 355 nm. AP visible-wavelength MALDI appears to be a softer ionization technique then AP UV MALDI for the analysis of sulfated peptides, while visible-wavelength MALDI-MS, MS/MS, and MS/MS/MS spectra of other biomolecules analyzed were mostly similar to those obtained by AP UV MALDI-MS. Therefore, the methodology presented will be useful for MS and MSn analyses of biomolecules at atmospheric pressure. Additionally, the AP visible-wavelength MALDI developed can be readily used for soft ionization of analytes on various mass spectrometers.
Figure
?  相似文献   

18.
Cysteine sulfonic acid-containing peptides, being typical acidic peptides, exhibit low response in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. In this study, matrix conditions and the effect of diammonium hydrogencitrate (DAHC) as additive were investigated for ionization of cysteine sulfonic acid-containing peptides in MALDI. A matrix-free ionization method, desorption/ionization on porous silicon (DIOS), was also utilized to evaluate the effect of DAHC. When equimolar three-component mixtures of peptides carrying free cysteine, cysteine sulfonic acid, and carbamidomethyl cysteine were measured by MALDI using a common matrix, alpha-cyano-4-hydroxycinnamic acid (CHCA), no signal corresponding to cysteine sulfonic acid-containing peptide could be observed in the mass spectrum. However, by addition of DAHC to CHCA, the peaks of cysteine sulfonic acid-containing peptides were successfully observed, as well as when using 2,4,6-trihydroxyacetophenone (THAP) and 2,6-dihydroxyacetophenone with DAHC. In the DIOS mass spectra of these analytes, the use of DAHC also enhanced the peak intensity of the cysteine sulfonic acid-containing peptides. On the basis of studies with these model peptides, tryptic digests of oxidized peroxiredoxin 6 were examined as a complex peptide mixture by MALDI and DIOS. In MALDI, the peaks of cysteine sulfonic acid-containing peptides were observed when using THAP/DAHC as the matrix, but this was not so with CHCA. In DIOS, the signal from cysteine sulfonic acid-containing peptides was suppressed; however, the use of DAHC significantly enhanced the signal intensity with an increase in the number of observed peptides and increased signal-to-noise ratio in the DIOS spectra. The results show that DAHC in the matrix or on the DIOS chip decreases discrimination and suppression effects in addition to suppressing alkali-adduct ions, which leads to a beneficial effect on protonation of peptides containing cysteine sulfonic acid.  相似文献   

19.
Matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) is an excellent analytical technique for rapid analysis of a variety of molecules with straightforward sample pretreatment. The performance of MALDI‐TOF MS is largely dependent on matrix type, and the development of novel MALDI matrices has aroused wide interest. Herein, we devoted to seek more robust MALDI matrix for herbal saponins than previous reported, and ginsenoside Rb1, Re, and notoginsenoside R1 were used as model saponins. At the beginning of the present study, 2,5‐dihydroxybenzoic acid (DHB) was found to provide the highest intensity for saponins in four conventional MALDI matrices, yet the heterogeneous cocrystallization of DHB with analytes made signal acquisition somewhat “hit and miss.” Then, graphene oxide (GO) was proposed as an auxiliary matrix to improve the uniformity of DHB crystallization due to its monolayer structure and good dispersion, which could result in much better shot‐to‐shot and spot‐to‐spot reproducibility of saponin analysis. The satisfactory precision further demonstrated that minute quantities of GO (0.1 μg/spot) could greatly reduce the risk of instrument contamination caused by GO detachment from the MALDI target plate under vacuum. More importantly, the sensitivity and linearity of the standard curve for saponins were improved markedly by DHB‐GO composite matrix. Finally, the application of detecting the Rb1 in complex biological sample was exploited in rat plasma and proved it applicable for pharmacokinetic study quickly. This work not only opens a new field for applications of DHB‐GO in herbal saponin analysis but also offers new ideas for the development of composite matrices to improve MALDI MS performance.  相似文献   

20.
Mechanistic arguments relative to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) address observations that predominately singly charged ions are detected. However, recently a matrix assisted laser ablation method, laserspray ionization (LSI), was introduced that can use the same sample preparation and laser as MALDI, but produce highly charged ions from proteins. In MALDI, ions are generated from neutral molecules by the photon energy provided to a matrix, while in LSI ions are produced inside a heated inlet tube linking atmospheric pressure and the first vacuum region of the mass spectrometer. Some LSI matrices also produce highly charged ions with MALDI ion sources operated at intermediate pressure or high vacuum. The operational similarity of LSI to MALDI, and the large difference in charge states observed by these methods, provides information of fundamental importance to proposed ionization mechanisms for LSI and MALDI. Here, we present data suggesting that the prompt and delayed ionization reported for vacuum MALDI are both fast processes relative to producing highly charged ions by LSI. The energy supplied to produce these charged clusters/droplets as well as their size and time available for desolvation are determining factors in the charge states of the ions observed. Further, charged droplets/clusters may be a common link for ionization of nonvolatile compounds by a variety of MS ionization methods, including MALDI and LSI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号