首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Ahn B  Lee K  Lee H  Panchapakesan R  Xu L  Xu J  Oh KW 《Lab on a chip》2011,11(22):3915-3918
We present a simple method of guiding, distributing, and storing of a train of shape-dependent droplets by using side flows, cavity guiding tracks, and storage chambers. The squeezing flow makes a train of flattened droplets to align to one side of the wall and the pushing flow guides it to one of the designated guiding tracks. Then the guided droplets move along the guiding track due to the lowered surface energy when they flow along the track. In addition, simultaneous droplet guiding and storing process has been demonstrated. An array of storage chambers placed in each track could store each train containing differently concentrated droplets. The proposed method will be useful for distribution of droplets for further processes or storing for multiplex, large-scale, dynamic assays over time.  相似文献   

2.
We demonstrate that optical tweezers can be used to control and characterize the coagulation and mixing state of aerosols. Liquid aerosol droplets of 2-14 mum in diameter are optically trapped and characterized by spontaneous and stimulated Raman scatterings, which together provide a unique signature of droplet size and composition. From the conventional bright field image, the size of the trapped droplet can be estimated and compared with that determined from stimulated Raman scattering, and the motion of the particle within the trapping plane can be recorded. A maximum of four droplets can be manipulated in tandem by forming multiple optical traps through rapid beam steering. The coagulation of two droplets can be studied directly by controlling two droplets. The limiting conditions under which optical forces and capillary forces dominate the aerosol coagulation event are explored by varying the relative optical trap strengths and characterizing the coagulation of different droplet sizes. Finally, we demonstrate that the coagulation of different aerosol components can be compared and the mixing state of the final coagulated droplet can be investigated. In particular, we compare the outcome of the coagulation of an aqueous sodium chloride aerosol droplet with a second aqueous droplet, with an ethanol droplet or with a decane droplet.  相似文献   

3.
L Xu  H Lee  R Panchapakesan  KW Oh 《Lab on a chip》2012,12(20):3936-3942
We propose a robust droplet fusion and sorting method for two parallel trains of droplets that is relatively insensitive to frequency and phase mismatch. Conventional methods of droplet fusion require an extremely precise control of aqueous/oil flows for perfect frequency matching between two trains of droplets. In this work, by combining our previous two methods (i.e., droplet synchronization using railroad-like channels and manipulation of shape-dependent droplets using guiding tracks), we realized an error-free droplet fusion/sorting device for the two parallel trains of droplets. If droplet pairs are synchronized through a railroad-like channel, they are electrically fused and the fused droplets transit to a middle guiding track to flow in a middle channel; otherwise non-synchronized non-fused droplets will be discarded into the side waste channels by flowing through their own guiding tracks. The simple droplet synchronization, fusion, and sorting technology will have widespread application in droplet-based chemical or biological experiments, where two trains of the chemically or biologically treated or pre-formed droplets yield a train of 100% one-to-one fused droplets at the desired outlet channel by sorting all the non-synchronized non-fused droplets into waste outlets.  相似文献   

4.
The behaviour of droplets entering a microfluidic chamber designed to house microelectrode detectors for real time analysis of clinical microdialysate is described. We have designed an analysis chamber to collect the droplets produced by multiphase flows of oil and artificial cerebral spinal fluid. The coalescence chamber creates a constant aqueous environment ideal for the placement of microelectrodes avoiding the contamination of the microelectrode surface by oil. A stream of alternating light and dark coloured droplets were filmed as they passed through the chamber using a high speed camera. Image analysis of these videos shows the colour change evolution at each point along the chamber length. The flow in the chamber was simulated using the general solution for Poiseuille flow in a rectangular chamber. It is shown that on the centre line the velocity profile is very close to parabolic, and an expression is presented for the ratio between this centre line velocity and the mean flow velocity as a function of channel aspect ratio. If this aspect ratio of width/height is 2, the ratio of flow velocities closely matches that of Poiseuille flow in a circular tube, with implications for connections between microfluidic channels and connection tubing. The droplets are well mixed as the surface tension at the interface with the oil dominates the viscous forces. However once the droplet coalesces with the solution held in the chamber, the no-slip condition at the walls allows Poiseuille flow to take over. The meniscus at the back of the droplet continues to mix the droplet and acts as a piston until the meniscus stops moving. We have found that the no-slip conditions at the walls of the chamber, create a banding effect which records the history of previous drops. The optimal position for sensors is to be placed at the plane of droplet coalescence ideally at the centre of the channel, where there is an abrupt concentration change leading to a response time ?16 ms, the compressed frame rate of the video. Further away from this point the response time and sensitivity decrease due to convective dispersion.  相似文献   

5.
Niu X  Gulati S  Edel JB  deMello AJ 《Lab on a chip》2008,8(11):1837-1841
A novel method is presented for controllably merging aqueous microdroplets within segmented flow microfluidic devices. Our approach involves exploiting the difference in hydrodynamic resistance of the continuous phase and the surface tension of the discrete phase through the use of passive structures contained within a microfluidic channel. Rows of pillars separated by distances smaller than the representative droplet dimension are installed within the fluidic network and define passive merging elements or chambers. Initial experiments demonstrate that such a merging element can controllably adjust the distance between adjacent droplets. In a typical scenario, a droplet will enter the chamber, slow down and stop. It will wait and then merge with the succeeding droplets until the surface tension is overwhelmed by the hydraulic pressure. We show that such a merging process is independent of the inter-droplet separation but rather dependent on the droplet size. Moreover, the number of droplets that can be merged at any time is also dependent on the mass flow rate and volume ratio between the droplets and the merging chamber. Finally, we note that the merging of droplet interfaces occurs within both compressing and the decompressing regimes.  相似文献   

6.
We present an integrated circuit/microfluidic chip that traps and moves individual living biological cells and chemical droplets along programmable paths using dielectrophoresis (DEP). Our chip combines the biocompatibility of microfluidics with the programmability and complexity of integrated circuits (ICs). The chip is capable of simultaneously and independently controlling the location of thousands of dielectric objects, such as cells and chemical droplets. The chip consists of an array of 128 x 256 pixels, 11 x 11 microm(2) in size, controlled by built-in SRAM memory; each pixel can be energized by a radio frequency (RF) voltage of up to 5 V(pp). The IC was built in a commercial foundry and the microfluidic chamber was fabricated on its top surface at Harvard. Using this hybrid chip, we have moved yeast and mammalian cells through a microfluidic chamber at speeds up to 30 microm sec(-1). Thousands of cells can be individually trapped and simultaneously positioned in controlled patterns. The chip can trap and move pL droplets of water in oil, split one droplet into two, and mix two droplets into one. Our IC/microfluidic chip provides a versatile platform to trap and move large numbers of cells and fluid droplets individually for lab-on-a-chip applications.  相似文献   

7.
Electrically polarizable micro- and nanoparticles and droplets can be trapped using the gradient electric field of electrodes. But the spatial profile of the resultant dielectrophoretic force is fixed once the electrode structure is defined. To change the force profile, entire complex lab-on-a-chip systems must be re-fabricated with modified electrode structures. To overcome this problem, we propose an approach for the dynamic control of the spatial profile of the dielectrophoretic force by interfacing the trap electrodes with a resistor and an inductor to form a resonant resistor–inductor–capacitor (RLC) circuit. Using a dielectrophoretically trapped water droplet suspended in silicone oil, we show that the resonator amplitude, detuning, and linewidth can be continuously varied by changing the supply voltage, supply frequency, and the circuit resistance to obtain the desired trap depth, range, and stiffness. We show that by proper tuning of the resonator, the trap range can be extended without increasing the supply voltage, thus preventing sensitive samples from exposure to high electric fields at the stable trapping position. Such unprecedented dynamic control of dielectrophoretic forces opens avenues for the tunable active manipulation of sensitive biological and biochemical specimen in droplet microfluidic devices used for single-cell and biochemical reaction analysis.  相似文献   

8.
We demonstrate the combination of a rails and anchors microfluidic system with laser forcing to enable the creation of highly controllable 2D droplet arrays. Water droplets residing in an oil phase can be pinned to anchor holes made in the base of a microfluidic channel, enabling the creation of arrays by the appropriate patterning of such holes. The introduction of laser forcing, via laser induced thermocapillary forces to anchored droplets, enables the selective extraction of particular droplets from an array. We also demonstrate that such anchor arrays can be filled with multiple, in our case two, droplets each and that if such droplets have different chemical contents, the application of a laser at their interface triggers their merging and a chemical reaction to take place. Finally by adding guiding rails within the microfluidic structure we can selectively fill large scale arrays with monodisperse droplets with significant control over their contents. In this way we make a droplet array filled with 96 droplets containing different concentrations of fluorescent microparticles.  相似文献   

9.
We developed a microfluidic device to form monodisperse droplets with high productivity by anisotropic elongation of a thread flow, defined as a threadlike flow of a dispersed liquid phase in a flow of an immiscible, continuous liquid phase. The thread flow was anisotropically elongated in the depth direction in a straight microchannel with a step, where the microchannel depth changed. Consequently, the elongated thread flow was given capillary instability (Rayleigh-Plateau instability) and was continuously transformed into monodisperse droplets at the downstream area of the step in the microchannel. We examined the effects of the flow rates of the dispersed phase and the continuous phase on the droplet formation behavior, including the droplet diameter and droplet formation frequency. The droplet diameter increased as the fraction of the dispersed-phase flow rate relative to the total flow rate increased and was independent of the total flow rate. The droplet formation frequency proportionally increased with the total flow rate at a constant dispersed-phase flow rate fraction. These results are explained in terms of a mechanism similar to that of droplet formation from a cylindrical liquid thread flow by Rayleigh-Plateau instability. The microfluidic device described was capable of forming monodisperse droplets with a 160-microm average diameter and 3-microm standard deviation at a droplet formation frequency of 350 droplets per second from a single thread flow. The highest total flow rate achieved was 6 mL/h using the present device composed of a straight microchannel with a step. We also demonstrated parallel droplet formation by anisotropic elongation of multiple thread flows; the process was applied to form W/O and O/W droplets. The highly productive droplet formation process presented in this study is expected to be useful for future industrial applications.  相似文献   

10.
The binary coalescence of aqueous droplets has been observed in a single-beam gradient-force optical trap. By measuring the time-dependent intensity for elastic scattering of light from the trapping laser, the dynamics of binary coalescence have been examined and the time scale for equilibration of a composite droplet to ambient conditions has been determined. These data are required for modeling the agglomeration of aqueous droplets in dense sprays and atmospheric aerosol. Elastic-light scattering from optically trapped particles has not been used previously to study the time-resolved dynamics of mixing. It is shown to offer a unique opportunity to characterize the binary coalescence of aqueous droplets with radii from 1 to 6 μm. The study of this size regime, which cannot be achieved by conventional imaging methods, is critical for understanding the interactions of droplets in the environment of dense sprays.  相似文献   

11.
A mathematical model for the desolvation of solvent droplets has been used in conjunction with an existing code for simulation of ICP fundamental parameters. The combination has been used for the calculation of droplet histories and desolvation behavior along the central channel of an ICP. Calculations have been performed for droplets of various sizes and under a variety of ICP operating conditions. As central-channel gas flow rate increases, the point of complete desolvation of the droplet shifts upward in the plasma, away from the load coil. This relationship is fairly linear. As forward power increases, the point of complete desolvation moves down in the discharge, closer to the load coil. This is approximately an inverse relationship. Finally, simulation of behavior for a log-normal size distribution of a large number of droplets (108) shows that the number of surviving droplets falls sigmoidally with height above the load coil. For most nebulizer/spray chamber systems, the desolvation process is complete at a well-defined height in the plasma.  相似文献   

12.
The miniaturization of analytical techniques is a general trend in speciation analytics. We have developed a new analytical technique combining high pressure liquid chromatography (HPLC) with laser-induced breakdown spectroscopy (LIBS). This enables a molecule-specific separation followed by an element-specific analysis of smallest amounts of complex samples. The liquid flow coming from a HPLC pump is transformed into a continuous stream of small droplets (diameter 50–100 μm, volume 65–500 pl) using a piezoelectric pulsed nozzle. After the detection of single droplets with a droplet detector, a Q-switched Nd:YAG Laser is triggered to emit a synchronized laser pulse that irradiates a single droplet. The droplets are evaporated and transformed to the plasma state. The spectrum emitted from the plasma is collected by a spherical mirror and directed through the entrance slit of a Paschen–Runge spectrometer equipped with channel photomultipliers. The spectrometer detects 31 elements simultaneously covering a spectral range from 120 to 589 nm. Purging the measurement chamber with argon enables the detection of vacuum–UV lines. Since the sample is transferred to the plasma state without dilution, very low flow rates in the sub-μl/min range can be realised.  相似文献   

13.
We study the effects of Marangoni stresses on the flow in an evaporating sessile droplet, by extending a lubrication analysis and a finite element solution of the flow field in a drying droplet, developed earlier. The temperature distribution within the droplet is obtained from a solution of Laplace's equation, where quasi-steadiness and neglect of convection terms in the heat equation can be justified for small, slowly evaporating droplets. The evaporation flux and temperature profiles along the droplet surface are approximated by simple analytical forms and used as boundary conditions to obtain an axisymmetric analytical flow field from the lubrication theory for relatively flat droplets. A finite element algorithm is also developed to solve simultaneously the vapor concentration, and the thermal and flow fields in the droplet, which shows that the lubrication solution with the Marangoni stress is accurate for contact angles as high as 40 degrees. From our analysis, we find that surfactant contamination, at a surface concentration as small as 300 molecules/microm(2), can almost entirely suppress the Marangoni flow in the evaporating droplet.  相似文献   

14.
Because of capillary forces, sessile droplets usually fuse instantaneously after contact. We find however a delay of the droplet fusion by many seconds if the droplets consist of different but completely miscible liquids. After the initial contact, the main bodies of the droplets remain separated, connected only through a shallow conduit with a flow from the low to the high surface tension liquid. Sporadically, this connecting film can thicken with turbulent or pulsating flows. The droplets will finally fuse when the flow has sufficiently reduced the difference in composition and surface tension. We present calculations which explain this delayed droplet fusion with the compensation of the fusion-promoting capillary pressure by a droplet-separating dynamic pressure caused by the flow between the droplets. Droplets with high contact angles fuse instantaneously. In this case, no separation-stabilizing dynamic pressure can build up because the interdroplet flow becomes turbulent.  相似文献   

15.
Li ZG  Ando K  Yu JQ  Liu AQ  Zhang JB  Ohl CD 《Lab on a chip》2011,11(11):1879-1885
A method for on-demand droplet fusion in a microfluidic channel is presented using the flow created from a single explosively expanding cavitation bubble. We test the technique for water-in-oil droplets, which are produced using a T-junction design in a microfluidic chip. The cavitation bubble is created with a pulsed laser beam focused into one droplet. High-speed photography of the dynamics reveals that the droplet fusion can be induced within a few tens of microseconds and is caused by the rapid thinning of the continuous phase film separating the droplets. The cavitation bubble collapses and re-condenses into the droplet. Droplet fusion is demonstrated for static and moving droplets, and for droplets of equal and unequal sizes. Furthermore, we reveal the diffusion dominated mixing flow and the transport of a single encapsulated cell into a fused droplet. This laser-based droplet fusion technique may find applications in micro-droplet based chemical synthesis and bioassays.  相似文献   

16.
《Electrophoresis》2018,39(4):597-607
We report herein a novel microfluidic particle concentrator that utilizes constriction microchannels to enhance the flow‐focusing performance of induced‐charge electroosmosis (ICEO), where viscous hemi‐spherical oil droplets are embedded within the mainchannel to form deformable converging‐diverging constriction structures. The constriction region between symmetric oil droplets partially coated on the electrode strips can improve the focusing performance by inducing a granular wake flow area at the diverging channel, which makes almost all of the scattered sample particles trapped within a narrow stream on the floating electrode. Another asymmetric droplet pair arranged near the outlets can further direct the trajectory of focused particle stream to one specified outlet port depending on the symmetry breaking in the shape of opposing phase interfaces. By fully exploiting rectification properties of induced‐charge electrokinetic phenomena at immiscible water/oil interfaces of tunable geometry, the expected function of continuous and switchable flow‐focusing is demonstrated by preconcentrating both inorganic silica particles and biological yeast cells. Physical mechanisms responsible for particle focusing and locus deflection in the droplet‐assisted concentrentor are analyzed in detail, and simulation results are in good accordance with experimental observations. Our work provides new routes to construct flexible electrokinetic framework for preprocessing on‐chip biological samples before performing subsequent analysis.  相似文献   

17.
The purpose of this article is to investigate the effects of channel sizes on the traffic of S/W compound droplets through a vertical channel. Compared with the horizontal channel, a vertical channel can effectively inhabit the contact of compound droplets with the channel wall, thus improving the survival rate. It is also found that the effects of tube length on droplet traffic are always dependent on the oil phase flow rate. In a short tube (L?=?2.0?cm), the survival rate increases as the oil phase flow rate increases. This may be due to significant prevention of coalescence among S/W compound droplets under a high oil phase flow rate. However, in a long tube (L?=?7.5?cm), the survival rate decreases with increasing oil phase flow rate, because disturbance of a water droplet can peel off the water phase coated on the surface of the solid particles. During the traffic process, the distance between water droplets and S/W compound droplets decreases linearly with time because of the larger diameter of the compound droplets. These study results can provide a useful guide for the preparation of high-throughput S/W compound droplets in a controllable and reproducible manner.  相似文献   

18.
A levitation device for charged particles has been used to position a single isolated droplet at a time at atmospheric pressure near the sampling orifice of a vacuum chamber. Following a brief desolvation period (550 ms), a series of coluomb fission events were initiated. Several atmospheric pressure electrode designs were evaluated with respect to guiding the progeny droplets/ions, to the sampling orifice. The best design tested consisted of a series of four annular electrodes of decreasing radius positioned above the levitation ring electrodes, and, on average, 40 ions were counted per single isolated droplet. The ion utilization (charge detected versus charge in the original droplet) with this electrode design has been estimated to be 5 x 10(-6), a substantial improvement over the current utilization measured to be < or = 1 x 10(-9) with a conventional electrospray ion source using the same vacuum apparatus.  相似文献   

19.
Passive microfluidic channel geometries for control of droplet fission, fusion and sorting are designed, fabricated, and tested. In droplet fission, the inlet width of the bifurcating junction is used to control the range of breakable droplet sizes and the relative resistances of the daughter channels were used to control the volume of the daughter droplets. Droplet fission is shown to produce concentration differences in the daughter droplets generated from a primary drop with an incompletely mixed chemical gradient, and for droplets in each of the bifurcated channels, droplets were found to be monodispersed with a less than 2% variation in size. Droplet fusion is demonstrated using a flow rectifying design that can fuse multiple droplets of same or different sizes generated at various frequencies. Droplet sorting is achieved using a bifurcating flow design that allows droplets to be separated base on their sizes by controlling the widths of the daughter channels. Using this sorting design, submicron satellite droplets are separated from the larger droplets.  相似文献   

20.
Sakakihara S  Araki S  Iino R  Noji H 《Lab on a chip》2010,10(24):3355-3362
The enzyme assay in a femtoliter chamber array is a simple and efficient method for concentrating the reaction product; it greatly improves the detection sensitivity down to the single-molecule level. However, in previous methods, controlling the initiation and termination of the reaction in each chamber is difficult once enclosed. Furthermore, the recovery of the enzyme and product is also difficult. To overcome these drawbacks, we developed a femtoliter droplet array in which the individual droplets are fixed on the substrate and are directly accessible from outside. A hydrophilic-in-hydrophobic micropatterned surface was used for the preparation of the droplets. When the aqueous solution on the surface is exchanged with oil, the hydrophilic surface retains the aqueous solution, and more than 10(6) dome-shaped droplets that are usable for further assay can be prepared simultaneously. The curvature radius of the droplet obeys the Young-Laplace equation, and the volume can be precisely controlled by the micropipette, which applies pressure into the droplet. Changing the pressure makes the addition, collection, and exchange of the aqueous content for individual droplets possible. Using these advantages, we successfully measured the kinetic parameters of the single-molecule enzyme β-galactosidase and rotary motor protein F(1)-ATPase enclosed in a droplet.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号