首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
Chen YA  King AD  Shih HC  Peng CC  Wu CY  Liao WH  Tung YC 《Lab on a chip》2011,11(21):3626-3633
This paper reports a microfluidic device capable of generating oxygen gradients for cell culture using spatially confined chemical reactions with minimal chemical consumption. The microfluidic cell culture device is constructed by single-layer polydimethylsiloxane (PDMS) microfluidic channels, in which the cells can be easily observed by microscopes. The device can control the oxygen gradients without the utilization of bulky pressurized gas cylinders, direct addition of oxygen scavenging agents, or tedious gas interconnections and sophisticated flow control. In addition, due to the efficient transportation of oxygen within the device using the spatially confined chemical reactions, the microfluidic cell culture device can be directly used in conventional cell incubators without altering their gaseous compositions. The oxygen gradients generated in the device are numerically simulated and experimentally characterized using an oxygen-sensitive fluorescence dye. In this paper, carcinomic human alveolar basal epithelial (A549) cells have been cultured in the microfluidic device with a growth medium and an anti-cancer drug (Tirapazamine, TPZ) under various oxygen gradients. The cell experiment results successfully demonstrate the hyperoxia-induced cell death and hypoxia-induced cytotoxicity of TPZ. In addition, the results confirm the great cell compatibility and stable oxygen gradient generation of the developed device. Consequently, the microfluidic cell culture device developed in this paper is promising to be exploited in biological labs with minimal instrumentation to study cellular responses under various oxygen gradients.  相似文献   

2.
We have developed a microfluidic gradient device for controlling mucin gene expression of NCI-H292 epithelial cells derived from lung tissues. We hypothesized that gradient profiles would control mucin gene expression of lung epithelial cells. However, it was not possible to generate various stable gradient profiles using conventional culture methods. To address this limitation, we used a microfluidic gradient device to create various gradient profiles (i.e. non-linear, linear, and flat) in a temporal and spatial manner. NCI-H292 lung epithelial cells were exposed to concentration gradients of epidermal growth factor in a microfluidic gradient device with continuous medium perfusion. We demonstrated an effect of gradient profiles on mucin expression of lung epithelial cells cultured in the microfluidic gradient device. It was revealed that NCI-H292 lung epithelial cells exposed to the flat gradient profile of the epidermal growth factor exhibited high expression of mucin as compared with cells exposed to non-linear and linear gradient profiles. Therefore, this microfluidic gradient device could be a potentially useful tool for regulating the mucin expression of lung epithelial cells exposed to chemokine gradient profiles.  相似文献   

3.
We have developed a technique for fabricating microfluidic devices from gelatin using a natural crosslinking process. Gelatin, crosslinked with the naturally occurring enzyme transglutaminase is molded to produce microchannels suitable for adherent cell culture and analysis. The autofluorescence of the material was shown to be minimal and within the range of typical background, ensuring utility with analyses using fluorescent dyes and labels would not be affected. Also, normal murine mammary epithelial cells were successfully cultured in the microchannels. The morphology of these adherent epithelial cells was shown to be significantly different for cells grown on rigid tissue culture plastic in either macro- or microscale cultures (even in the presence of a surface coating of gelatin) than those grown on the flexible crosslinked gelatin microchannels. Using these devices, the effects of both the extracellular matrix and soluble factors on cellular behavior and differentiation can be studied in microenvironments that more closely mimic the in vivo environment.  相似文献   

4.
Wang Y  Chen Z  Xiao L  Du Z  Han X  Yu X  Lu Y 《Electrophoresis》2012,33(5):773-779
Cell migration is an early-stage and critical step for cancer metastasis. The most common approach to monitor this process is wound-healing assay. However, this traditional method has some unavoidable limitations. We observed that simply scratching the monolayer of cultured cells might cause local cell damage around the injury line. The cells along the scratched border seemed to be irritated and exhibited abnormal distribution of cytoskeleton reassembly with protruding "cell islands" and "pseudopodia" during wound healing, which might potentially affect the assessment of cell migration behavior. Herein, we applied a microfluidic device that mechanically constrained cells seeded in a designed pattern inside microchannels, and monitored cell movement in a way of mimicking the natural microenvironment of cancerous tissues. We illustrated the capacity of this simple method to probe cellular migration behaviors and to screen some biological active agents that reflected in their influence on cellular motility.  相似文献   

5.
Epithelial‐to‐mesenchymal transition (EMT), a process in which epithelial cells undergo phenotypic transitions to fibrotic cells, is induced by stimulants including transforming growth factor‐beta1 (TGF‐β1). In the present study, we developed a microfluidic gradient device to reproduce EMT in A549 human lung alveolar epithelial cells in response to TGF‐β1 gradients. The device was directly mounted on the cells that had grown in cell culture plates and produced a stable concentration gradient of TGF‐β1 with negligible shear stress, thereby providing a favorable environment for the anchorage‐dependent cells. A549 cells elongated with the characteristic spindle‐shaped morphological changes with upregulation of alpha‐smooth muscle actin, a mesenchyme marker, in a gradient‐dependent manner, suggestive of EMT progression. We observed that at higher TGF‐β1 concentrations ranging from 5 to 10 ng/mL, the cultures in the microfluidic device allowed to quantitatively pick up subtle differences in the EMT cellular response as compared with plate cultures. These results suggest that the microfluidic gradient device would accurately determine the optimal concentrations of TGF‐β1, given that epithelial cells of different tissue origins greatly vary their responses to TGF‐β1. Therefore, this microfluidic device could be a powerful tool to monitor EMT induced by a variety of environmental stresses including cigarette smoke with high sensitivity.  相似文献   

6.
There as an urgent need to quantify the endothelial wound-healing process in response to fluid shear stress to improve the biological and clinical understanding of healing mechanisms, which is of great importance for preventing healing impairment, chronic wounds, and postoperative in-stent restenosis. However, current experimental platforms not only require expensive, cumbersome, and powered pumping devices (to, e.g., generate cell scratches and load shear stress stimulation) but also lack quantitative controls for quantitative analysis. In this paper, a passive pump-assisted microfluidic assay is developed to quantify endothelial wound healing in response to fluid shear stress. Our assay consists of passive constant-flow pumps based on the siphon principle and a three-inlet microfluidic chip for cell wound-healing experiments. We also propose a method for quantitatively adjusting cell scratch size by controlling trypsin flow. Both numerical simulations and fluorescein experiments validate the effectiveness of this method. Moreover, we use the designed microfluidic assay to successfully generate cell scratches, load a 12-h shear stress of 5 dyn/cm2 to the cells, and observe wound healing. The results indicate that the healing of a cell scratch is significantly accelerated under the stimulation of shear stress. In conclusion, our passive pump-assisted microfluidic assay shows versatility, applicability, and the potential for quantifying endothelial wound healing in response to fluid shear stress.  相似文献   

7.
Studies using this micro-system demonstrated significant morphological differences between alveolar epithelial cells (transformed human alveolar epithelial cell line, A549 and primary murine alveolar epithelial cells, AECs) exposed to combination of solid mechanical and surface-tension stresses (cyclic propagation of air-liquid interface and wall stretch) compared to cell populations exposed solely to cyclic stretch. We have also measured significant differences in both cell death and cell detachment rates in cell monolayers experiencing combination of stresses. This research describes new tools for studying the combined effects of fluid mechanical and solid mechanical stress on alveolar cells. It also highlights the role that surface tension forces may play in the development of clinical pathology, especially under conditions of surfactant dysfunction. The results support the need for further research and improved understanding on techniques to reduce and eliminate fluid stresses in clinical settings.  相似文献   

8.
Lee JM  Kim JE  Kang E  Lee SH  Chung BG 《Electrophoresis》2011,32(22):3133-3137
We developed an integrated microfluidic culture device to regulate embryonic stem (ES) cell fate. The integrated microfluidic culture device consists of an air control channel and a fluidic channel with 4×4 micropillar arrays. We hypothesized that the microscale posts within the micropillar arrays would enable the control of uniform cell docking and shear stress profiles. We demonstrated that ES cells cultured for 6 days in the integrated microfluidic culture device differentiated into endothelial cells. Therefore, our integrated microfluidic culture device is a potentially powerful tool for directing ES cell fate.  相似文献   

9.
We developed the dual‐micropillar‐based microfluidic platform to direct embryonic stem (ES) cell fate. 4 × 4 dual‐micropillar‐based microfluidic platform consisted of 16 circular‐shaped outer micropillars and 8 saddle‐shaped inner micropillars in which single ES cells were cultured. We hypothesized that dual‐micropillar arrays would play an important role in controlling the shear stress and cell docking. Circular‐shaped outer micropillars minimized the shear stress, whereas saddle‐shaped inner micropillars allowed for docking of individual ES cells. We observed the effect of saddle‐shaped inner micropillars on cell docking in response to hydrodynamic resistance. We also demonstrated that ES cells cultured for 6 days within the dual‐micropillar‐based microfluidic platform differentiated into neural‐like cells. Therefore, this dual‐micropillar‐based microfluidic platform could be a potentially powerful method for screening of lineage commitments of single ES cells.  相似文献   

10.
Blue visible light damage to retinal pigment epithelial cells occurs through a photooxidative mechanism and the resultant damage is hypothesized to induce or exacerbate age-related macular degeneration. The purpose of the present study was to identify changes in the cell growth and the expression of hepatocyte growth factor (HGF) in cultured human retinal pigment epithelium (RPE) cells as a result of both blue and red light irradiation. HGF is a growth factor and neurotrophic factor that stimulates growth of various ocular cells and promotes the survival of RPE and retinal neurons. Early passages of human RPE cells were exposed to blue light (460 nm) and red light (640 nm). Nonirradiated cells were used as controls. After 24 and 48 h, conditioned medium was collected and the amount of HGF was measured by ELISA. Cells were detached from the well and counted. Cell viability was evaluated by trypan-blue exclusion study. Blue light at dosage of 63 J/cm(2) significantly inhibited the growth of RPE cells without affecting of cell viability. Amounts of HGF in the culture medium were significantly inhibited by blue-light irradiation at the dosage from 32 to 63 J/cm(2). Red light at a dose of 174 J/cm(2) causes a nonsignificant inhibition of growth of RPE cells and a slight decrease of secretion of HGF. As HGF promotes survival of RPE cells and retinal neurons, the inhibition of production of HGF by visible light, especially by blue light, may enhance the phototoxic effects of visible light on the RPE and retinal neurons.  相似文献   

11.
Kwon KW  Choi SS  Lee SH  Kim B  Lee SN  Park MC  Kim P  Hwang SY  Suh KY 《Lab on a chip》2007,7(11):1461-1468
A label-free microfluidic method for separation and enrichment of human breast cancer cells is presented using cell adhesion as a physical marker. To maximize the adhesion difference between normal epithelial and cancer cells, flat or nanostructured polymer surfaces (400 nm pillars, 400 nm perpendicular, or 400 nm parallel lines) were constructed on the bottom of polydimethylsiloxane (PDMS) microfluidic channels in a parallel fashion using a UV-assisted capillary moulding technique. The adhesion of human breast epithelial cells (MCF10A) and cancer cells (MCF7) on each channel was independently measured based on detachment assays where the adherent cells were counted with increasing flow rate after a pre-culture for a period of time (e.g., one, two, and four hours). It was found that MCF10A cells showed higher adhesion than MCF7 cells regardless of culture time and surface nanotopography at all flow rates, resulting in label-free separation and enrichment of cancer cells. For the cell types used in our study, an optimum separation was found for 2 hours pre-culture on the 400 nm perpendicular line pattern followed by flow-induced detachment at a flow rate of 200 microl min(-1). The fraction of MCF7 cells was increased from 0.36 +/- 0.04 to 0.83 +/- 0.04 under these optimized conditions.  相似文献   

12.
Kim HJ  Huh D  Hamilton G  Ingber DE 《Lab on a chip》2012,12(12):2165-2174
Development of an in vitro living cell-based model of the intestine that mimics the mechanical, structural, absorptive, transport and pathophysiological properties of the human gut along with its crucial microbial symbionts could accelerate pharmaceutical development, and potentially replace animal testing. Here, we describe a biomimetic 'human gut-on-a-chip' microdevice composed of two microfluidic channels separated by a porous flexible membrane coated with extracellular matrix (ECM) and lined by human intestinal epithelial (Caco-2) cells that mimics the complex structure and physiology of living intestine. The gut microenvironment is recreated by flowing fluid at a low rate (30 μL h(-1)) producing low shear stress (0.02 dyne cm(-2)) over the microchannels, and by exerting cyclic strain (10%; 0.15 Hz) that mimics physiological peristaltic motions. Under these conditions, a columnar epithelium develops that polarizes rapidly, spontaneously grows into folds that recapitulate the structure of intestinal villi, and forms a high integrity barrier to small molecules that better mimics whole intestine than cells in cultured in static Transwell models. In addition, a normal intestinal microbe (Lactobacillus rhamnosus GG) can be successfully co-cultured for extended periods (>1 week) on the luminal surface of the cultured epithelium without compromising epithelial cell viability, and this actually improves barrier function as previously observed in humans. Thus, this gut-on-a-chip recapitulates multiple dynamic physical and functional features of human intestine that are critical for its function within a controlled microfluidic environment that is amenable for transport, absorption, and toxicity studies, and hence it should have great value for drug testing as well as development of novel intestinal disease models.  相似文献   

13.
Zheng C  Yu Z  Zhou Y  Tao L  Pang Y  Chen T  Zhang X  Qiu H  Zhou H  Chen Z  Huang Y 《Lab on a chip》2012,12(17):3063-3072
Epigenetic regulation plays an important role in cell migration. Although many methods have been developed to measure the motility of mammalian cells, accurate quantitative assessments of the migration speed of individual cells remain a major challenge. It is difficult for conventional scratch assays to differentiate proliferation from migration during the so-called wound-healing processes because of the long experimental time required. In addition, it is also challenging to create identical conditions for evaluating cell migration by conventional methods. We developed a microfluidic device with precisely created blanks allowing for robust and reproducible cell migration inside accurately-controlled microenvironments to study the regulatory effect of the epigenetic regulator histone deacetylase 7 (HDAC7) on cell migration. Through analyzing time-lapse imaging of the cells migrating into individual blank regions, we can measure the migration speed parameter for human primary cells within a few hours, eliminating the confounding effect of cell proliferation. We also developed an automatic image analysis and a numeric model-based data fitting to set up an integrated cell migration analysis system at single-cell resolution. Using this system, we measured the motility of primary human umbilical vein endothelial cells (HUVECs) and the migration speed reduction due to the silencing of HDAC7 and various other genes. We showed that the migration behaviour of these human primary cells are clearly regulated by epigenetic mechanisms, demonstrating the great potential of this accurate and robust assay in the fields of quantitatively migration studies and high-throughput screening.  相似文献   

14.
Kim J  Taylor D  Agrawal N  Wang H  Kim H  Han A  Rege K  Jayaraman A 《Lab on a chip》2012,12(10):1813-1822
We describe the development of a fully automatic and programmable microfluidic cell culture array that integrates on-chip generation of drug concentrations and pair-wise combinations with parallel culture of cells for drug candidate screening applications. The device has 64 individually addressable cell culture chambers in which cells can be cultured and exposed either sequentially or simultaneously to 64 pair-wise concentration combinations of two drugs. For sequential exposure, a simple microfluidic diffusive mixer is used to generate different concentrations of drugs from two inputs. For generation of 64 pair-wise combinations from two drug inputs, a novel time dependent variable concentration scheme is used in conjunction with the simple diffusive mixer to generate the desired combinations without the need for complex multi-layer structures or continuous medium perfusion. The generation of drug combinations and exposure to specific cell culture chambers are controlled using a LabVIEW interface capable of automatically running a multi-day drug screening experiment. Our cell array does not require continuous perfusion for keeping cells exposed to concentration gradients, minimizing the amount of drug used per experiment, and cells cultured in the chamber are not exposed to significant shear stress continuously. The utility of this platform is demonstrated for inducing loss of viability of PC3 prostate cancer cells using combinations of either doxorubicin or mitoxantrone with TRAIL (TNF-alpha Related Apoptosis Inducing Ligand) either in a sequential or simultaneous format. Our results demonstrate that the device can capture the synergy between different sensitizer drugs and TRAIL and demonstrate the potential of the microfluidic cell array for screening and optimizing combinatorial drug treatments for cancer therapy.  相似文献   

15.
Hepatocyte growth factor (HGF) has been revealed to exert multipotent activities on a variety of cells. In this study, we investigated whether HGF had a direct neuroprotection on cultured cerebral cortical neurons subjected to hypoxia/reoxygenation (H/R) and explored the intracellular signalings mediated the effects. The decrease in cell viability and increase in number of apoptotic cells resulting from H/R were significantly prevented by HGF pre-treatment. HGF stimulated both ERK1/2 and Akt activities in cortical neurons. Inhibition of ERK activation completely abolished the protective effects of HGF, and inhibition of Akt activation reduced, but did not completely eliminate the HGF mediated neuroprotection. It is suggested that the neuroprotection of HGF depend on ERK1/2 pathway, and, to a lesser extent, PI-3K/Akt pathway. In addition, we found that pre-treatment with HGF remarkably attenuated the decrease in expression of Bcl-2 and Bcl-xL induced by H/R, but failed to affect the amount of Bax. It is likely that Bcl-2 and Bcl-xL contribute to the protective effects of HGF.  相似文献   

16.
Mammalian cells cultured on 2D surfaces in microfluidic channels are increasingly used in drug development and biological research applications. These systems would have more biological or clinical relevance if the cells exhibit 3D phenotypes similar to the cells in vivo. We have developed a microfluidic channel based system that allows cells to be perfusion-cultured in 3D by supporting them with adequate 3D cell-cell and cell-matrix interactions. The maximal cell-cell interaction was achieved by perfusion-seeding cells through an array of micropillars; and 3D cell-matrix interactions were achieved by a polyelectrolyte complex coacervation process to form a thin layer of matrix conforming to the 3D cell shapes. Carcinoma cell lines (HepG2, MCF7), primary differentiated (hepatocytes) and primary progenitor cells (bone marrow mesenchymal stem cells) were perfusion-cultured for 72 hours to 1 week in the microfluidic channel, which preserved their 3D cyto-architecture and cell-specific functions or differentiation competence. This transparent 3D microfluidic channel-based cell culture system also allows direct optical monitoring of cellular events for a wide range of applications.  相似文献   

17.
This paper describes a gradient-generating microfluidic platform for optimizing proliferation and differentiation of neural stem cells (NSCs) in culture. Microfluidic technology has great potential to improve stem cell (SC) cultures, whose promise in cell-based therapies is limited by the inability to precisely control their behavior in culture. Compared to traditional culture tools, microfluidic platforms should provide much greater control over cell microenvironment and rapid optimization of media composition using relatively small numbers of cells. Our platform exposes cells to a concentration gradient of growth factors under continuous flow, thus minimizing autocrine and paracrine signaling. Human NSCs (hNSCs) from the developing cerebral cortex were cultured for more than 1 week in the microfluidic device while constantly exposed to a continuous gradient of a growth factor (GF) mixture containing epidermal growth factor (EGF), fibroblast growth factor 2 (FGF2) and platelet-derived growth factor (PDGF). Proliferation and differentiation of NSCs into astrocytes were monitored by time-lapse microscopy and immunocytochemistry. The NSCs remained healthy throughout the entire culture period, and importantly, proliferated and differentiated in a graded and proportional fashion that varied directly with GF concentration. These concentration-dependent cellular responses were quantitatively similar to those measured in control chambers built into the device and in parallel cultures using traditional 6-well plates. This gradient-generating microfluidic platform should be useful for a wide range of basic and applied studies on cultured cells, including SCs.  相似文献   

18.
A novel method for studying unlabeled living mammalian cells based on their autofluorescence (AF) signal in a prototype microfluidic device is presented. When combined, cellular AF detection and microfluidic devices have the potential to facilitate high-throughput analysis of different cell populations. To demonstrate this, unlabeled cultured cells in microfluidic devices were excited with a 488 nm excitation light and the AF emission (> 505 nm) was detected using a confocal fluorescence microscope (CFM). For example, a simple microfluidic three-port glass microstructure was used together with conventional electroosmotic flow (EOF) to switch the direction of the fluid flow. As a means to test the potential of AF-based cell sorting in this microfluidic device, granulocytes were successfully differentiated from human red blood cells (RBCs) based on differences in AF. This study demonstrated the use of a simple microfabricated device to perform high-throughput live cell detection and differentiation without the need for cell-specific fluorescent labeling dyes and thereby reducing the sample preparation time. Hence, the combined use of microfluidic devices and cell AF may have many applications in single-cell analysis.  相似文献   

19.
We report a functionalisation strategy which is able to generate Ricinus communis agglutinin I (RCA 120) modified PMMA microfluidic device for binding and culturing living cells. The functionalisation is achieved by standard amine-aldehyde (Schiff base) reaction through the cross-linker, glutaraldehyde. To prove the ability of the RCA 120 modified PMMA surface, the PC 12 cell line (rat pheochromocytoma cells) has been captured and cultured by the microfluidic device. In the presence of tunicamycin, the dose/time-dependence on decreasing of binding affinity of RCA 120 modified device with PC 12 cell is also observed. The experimental results demonstrate that the lectin-functionalized microfluidic device can be employed as efficient cell culturing platform, and has a great promise of being used as a powerful tool for monitoring the interaction of drug with living cell.  相似文献   

20.
Digital microfluidics (DMF) is a technology that facilitates electrostatic manipulation of discrete nano- and micro-litre droplets across an array of electrodes, which provides the advantages of single sample addressability, automation, and parallelization. There has been considerable interest in recent years in using DMF for cell culture and analysis, but previous studies have used immortalized cell lines. We report here the first digital microfluidic method for primary cell culture and analysis. A new mode of "upside-down" cell culture was implemented by patterning the top plate of a device using a fluorocarbon liftoff technique. This method was useful for culturing three different primary cell types for up to one week, as well as implementing a fixation, permeabilization, and staining procedure for F-actin and nuclei. A multistep assay for monocyte adhesion to endothelial cells (ECs) was performed to evaluate functionality in DMF-cultured primary cells and to demonstrate co-culture using a DMF platform. Monocytes were observed to adhere in significantly greater numbers to ECs exposed to tumor necrosis factor (TNF)-α than those that were not, confirming that ECs cultured in this format maintain in vivo-like properties. The ability to manipulate, maintain, and assay primary cells demonstrates a useful application for DMF in studies involving precious samples of cells from small animals or human patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏