 共查询到20条相似文献,搜索用时 15 毫秒
1.
An atmosphere to vacuum interface was designed to exploit the different mobility and momentum characteristics of ions, and charged and neutral particles in electrospray ionization-mass spectrometry. The purpose of this device is to transmit with high efficiency the ions created at atmospheric pressure into the mass analyzer and to deflect the large charged and neutral particles prior to entrance into the vacuum system, thereby maintaining system cleanliness and stability. This interface is particularly suitable for low flow rate electrospray ionization-mass spectrometry where the close proximity of the electrospray emitters to the vacuum entrance, and near total consumption of the entire spray, leads to the production of large quantities of non-desolvated droplets and large charged and neutral particles. The improvement involves the application of potential gradients to a particle discriminator space located between the gas restricting ion entrance orifice of the mass spectrometer and the exit of a heated laminar flow chamber to divert large particles from the gas conductance limiting orifice. A counter-current flow of drying gas is used to deflect neutral particles and solvent vapor. Two stages of desolvation are achieved with the combined effects of the curtain gas and heated laminar flow chamber. This enhances the efficiency of desolvation and ion production, and stabilizes the resulting ion current under a wide variety of solvent compositions. In addition, this system eliminates the problems associated with the boiling of solution in nanospray tips when operated in close proximity to a heated mass spectrometer inlet. The particle discriminator interface gives approximately a 2-fold improvement in ion count rates, and a 3-fold improvement in stability (as measured by the signal relative standard deviation).  相似文献   

2.
黄晓兰  吴惠勤  黄芳  林晓珊  朱志鑫 《色谱》2009,27(3):279-282
采用电喷雾质谱(ESI/MS)技术建立了脂肪醇聚氧乙烯醚硫酸钠(AES)的烷基碳链分布、乙氧基分布及平均EO数、平均相对分子质量的测定方法;采用液相色谱-电喷雾质谱(LC-ESI/MS)测定了AES中的游离十二烷基硫酸钠(SDS)的含量。将本方法应用于实际样品的测定,并与核磁共振法测得的平均EO数进行比较,二者的测定结果相当吻合,从而验证了本法的可靠性。  相似文献   

3.
Simulations show that significant ion losses occur within the commercial electrospray ionization-field asymmetric waveform ion mobility spectrometer (ESI-FAIMS) interface owing to an angular desolvation gas flow and because of the impact of the FAIMS carrier gas onto the inner rf (radio frequency) electrode. The angular desolvation gas flow diverts ions away from the entrance plate orifice while the carrier gas annihilates ions onto the inner rf electrode. A novel ESI-FAIMS interface is described that optimizes FAIMS gas flows resulting in large improvements in transmission. Simulations with the bromochloroacetate anion showed an improvement of ~9-fold to give ~70% overall transmission). Comparable transmission improvements were attained experimentally for six peptides (2+) in the range of m/z 404.2 to 653.4 at a chromatographic flow rate of 300 nL/min. Selected ion chromatograms (SIC) from nano-LC-FAIMS-MS analyses showed 71% (HLVDEPQNLIK, m/z 653.4, 2+) to 95% (LVNELTEFAK, m/z 582.3, 2+) of ion signal compared with ion signal in the SIC from LC-MS analysis. IGSEVYHNLK (580.3, 2+) showed 24% more ion signal compared with LC-MS and is explained by enhanced desolvation in FAIMS. A 3–10 times lower limits of quantitation (LOQ) (<15% RSD) was achieved for chemical noise limited peaks with FAIMS. Peaks limited by ion statistics showed subtle improvement in RSD and yielded comparable LOQ to that attained with nano-LC-MS (without FAIMS). These improvements were obtained using a reduced FAIMS separation gap (from 2.5 to 1.5 mm) that results in a shorter residence time (13.2 ms?±?3.9 ms) and enables the use of a helium free transport gas (100% nitrogen). Graphical Abstract
?  相似文献   

4.
A particle beam interface has been coupled to a quadrupole ion trap mass spectrometer. The system allows the collection of electron ionization mass spectra from analyte in solution. The interface incorporates a pneumatic nebulizer, a heated desolvation chamber, and a three-stage separator region. Additional helium, for improved performance, is added through stage 3. The particles formed in the interface are separated from solvent molecules and are transferred directly to the ion trap where they are expected to collide with the hot hyperbolic surface of the end cap. The end cap serves both as a heated target used to vaporize the particles and as an ion-trapping electrode. Mass analysis is achieved with the mass-selective instability scan supplemented with resonance ejection. Electron ionization spectra from 100 ng of caffeine [molecular weight (MW) = 1941; 1-naphthalenol methylcarbamate (carbaryl) (MW = 2011, 17α-hydroxyprogesterone (MW = 330), and reserpine (MW = 608) are shown using sampling by a segmented flow analysis. Some charge exchange is evident with methanol as well as self-chemical ionization at higher analyte levels. The interface shows a nonlinear caffeine calibration curve for analyte amounts below 30 ng and a more linear response at higher amounts. Caffeine was detected at 25 pmol (5 ng), with a signal-to-noise ratio of 50, 20-μL loop, full scan.  相似文献   

5.
水溶液样品用超声雾化法雾化经加热后用常规冷凝器和浓H_2SO_4吸收法去溶,然后引入微波等离子体。详细考察了载气流量、微波功率和HCl浓度等实验条件的影响和KCl对谱线的增强作用。测定了一些地质样品中的铁,得到了满意的结果。  相似文献   

6.
Akinbo OT  Carnahan JW 《Talanta》1997,45(1):137-146
Results obtained from a preliminary investigation of the performance of a flat sheet membrane desolvator (FSMD) utilizing dual hydrophobic polypropylene membranes with an average pore size of 0.05 mum and a 50 +/- 5 mum thickness are reported. The membranes have a desolvation area of 241 cm(2). The volume-to-surface area ratio is 0.3 cm. Using the FSMD with an ultrasonic nebulizer (USN), aqueous solvent desolvation efficiencies of greater than 99.9% were obtained at all nebulizer gas flow rates investigated (0.8, 1.2, and 1.8 l min(-1)). This efficient desolvation occurred when the countercurrent gas flow rate was equal to or slightly greater than the applied nebulizer gas flow rate. Under these conditions preconcentration factors of 18, 44, and 590 were observed with flows of 0.8, 1.2 and 1.8 l min(-1), respectively. Operating with countercurrent gas flow rates much higher than the nebulizer gas flow rates leads to a significant reduction in analyte flux, thus increasing detection limits. Depending on the nebulizer and countercurrent gas flow rate conditions, the FSMD contributed between 10-40% to the overall analyte loss in the system. The lowest detection limit observed for aqueous copper with the USN-FSMD system is 0.4 ppb at nebulizer and countercurrent gas flow rates of 1.2 and 1.4 l min(-1), respectively. At this nebulizer gas flow rate, replacing the FSMD in the system with a commercial tubular membrane desolvator, MDX100, gave a lowest Cu detection limit of 0.2 ppb at a countercurrent gas flow rate of 1.2 l min(-1). These detection limits represents improvements over the 0.7 and 8 ppb obtained with USN and pneumatic nebulization, respectively.  相似文献   

7.
A multi-tube Nafion® membrane dryer used as a part of a desolvation system in conjunction with thermospray nebulization was optimized and characterized with inductively coupled plasma-atomic emission spectrometry (ICP-AES). Either argon or nitrogen could be used as the sweep gas, and optimum conditions were found to be at low temperature and low sweep gas flow rate. Analyte sensitivity was not significantly affected by placing the membrane between the plasma and the nebulizer, although about 20% of the analyte entering the dryer is lost within the dryer. A dual role of the membrane dryer was demonstrated. As a secondary step within the desolvation system, it enabled a high desolvation efficiency of 99.94% for aerosols from 1% (v/v) nitric acid. Plasma solvent load could be reduced to 0.9 mg min−1 with a tap water cooled condenser combined with the membrane dryer, compared to 21 mg min−1 with the normal chilled condenser desolvation system. Meanwhile, the membrane was also found to act as a pulse dampener, eliminating the plasma pulsation in the central channel caused by thermospray nebulization and thus improving the analytical performance of the system. The average relative standard deviations (RSD) with the optimized membrane/thermospray system were 0.83% and 0.60% for the background and analyte signals, respectively, which were reduced by a factor of 1.9 and 2.7 for the background and analyte signals, respectively, compared to thermospray without the membrane desolvation, and were essentially identical to those obtained with pneumatic nebulization sample introduction. The improvements in detection limits with the membrane/thermospray system were 1.2–3.0 times with an average factor of 1.8 compared to thermospray without the membrane dryer, and 18–68 times with an average factor of 39 compared to the standard pneumatic nebulization sample introduction system without a desolvation unit. The detection limits for Mn, Mg, Cr and Cd with the present thermospray/membrane system were comparable to those reported for pneumatic nebulization ICP mass spectrometry.  相似文献   

8.
Organic extractables (substances extracted from materials used in pharmaceutical packaging) are discovered, identified, and quantified via screening of extracts with analytical methods including liquid chromatography with mass spectrometric detection (LC-MS). Because extractables include a large number of diverse compounds that are typically present in plastic extracts at low levels, the LC-MS methods must be broad scope and sensitive. To accomplish these objectives, screening studies typically couple gradient reversed-phase separations with electrospray MS detection (both positive and negative ion modes). While such methods are generally applicable for a number of extractables, they are not optimal for some commonly encountered extractables due to either poor chromatographic performance (e.g., peak tailing) or poor MS response. Modifications to mobile phase composition (e.g., pH adjustment) were examined to improve the performance of an LC-MS screening method. The use of 0.1% acetic acid with 1 mM ammonium acetate (pH 3.6) as the aqueous portion of the mobile phase provided favorable sensitivities for a number of extractables both in positive and negative ion modes. In positive ion mode, the acidic mobile phase improved responses for moderately weak basic compounds by increasing their degree of protonation. For very weak basic compounds such as amides, ammonium ions in the mobile phase promoted proton adduct responses. In negative ion mode, an acidic mobile phase containing acetate anion improved ESI responses for acidic compounds, primarily due to gas phase effects.  相似文献   

9.
A pneumatically-driven, high efficiency nebulizer is explored for helium inductively coupled plasma mass spectrometry. The aerosol characteristics and analyte transport efficiencies of the high efficiency nebulizer for nebulization with helium are measured and compared to the results obtained with argon. Analytical performance indices of the helium inductively coupled plasma mass spectrometry are evaluated in terms of detection limits and precision. The helium inductively coupled plasma mass spectrometry detection limits obtained with the high efficiency nebulizer at 200 μL/min are higher than those achieved with the ultrasonic nebulizer consuming 2 mL/min solution, however, precision is generally better with high efficiency nebulizer (1–4% vs. 3–8% with ultrasonic nebulizer). Detection limits with the high efficiency nebulizer at 200 μL/min solution uptake rate approach those using ultrasonic nebulizer upon efficient desolvation with a heated spray chamber followed by a Peltier-cooled multipass condenser.  相似文献   

10.
Two-dimensional mapping of the excitation temperatures have been carried out in the microwave-induced plasma torch with tangential argon flow. It is detected that the presence of wet aerosols in a nebulizer gas increases axial excitation temperature while desolvation acts in the opposite direction. The influence of low hydrogen concentration in the support gas and potassium in the nebulizer gas on the temperature distribution is studied in detail. The comparison of excitation temperature and electron number density distributions clearly indicates non-equilibrium plasma conditions.  相似文献   

11.
In this work a new electrospray system has been developed which employs heat as a means of desolvation and requires no counterflow of heated gas. This article describes the operation and performance of this device, with particular emphasis on the differences between it and those described earlier. Results are presented that illustrate the dependence of signal intensity on ion source and spray chamber temperatures and on the composition and flow rate of mobile phase into the electrospray. Results on proteins electrosprayed from aqueous solutions are presented including a bacterial protease which has a tight tertiary structure. The ability to obtain fragmentation data by collisionally induced dissociation in the interface is also discussed.  相似文献   

12.
This article presents a comparative study of the performance, operational, and instrumental characteristics of AP and vacuum MALDI for the analysis of peptides and protein digests. Spectra generated with the two ion sources were surprisingly similar, both qualitatively and quantitatively, with vacuum MALDI generating ion count rates that were approximately a factor of 2 greater than those generated with AP MALDI on this system. Even though the peptide signals were 2X greater with vacuum MALDI, the background intensities also increased by a similar amount, leading to approximately equivalent signal/background ratios for digests and peptide mixtures. The results suggest that when AP MALDI conditions are properly optimized, the sensitivity can approach that of vacuum MALDI. However, AP MALDI performance is critically affected by source gas flows, potentials, and temperature, making it operationally more complex. In addition, evidence is provided for thermal degradation of samples stored on a target plate within a heated AP MALDI ion source. An improved interface for atmosphere to vacuum ion transfer substantially improved these characteristics.  相似文献   

13.
Manipulation for simplifying or increasing the observed charge state distributions of proteins can be highly desirable in mass spectrometry experiments. In the present work, we implemented a vapor introduction technique to an Agilent Jet Stream ESI (Agilent Technologies, Santa Clara, CA, USA) source. An apparatus was designed to allow for the enrichment of the nitrogen sheath gas with basic vapors. An optical setup, using laser-induced fluorescence and a pH-chromic dye, permits the pH profiling of the droplets as they evaporate in the electrospray plume. Mechanisms of pH droplet modification and its effect on the protein charging phenomenon are elucidated. An important finding is that the enrichment with basic vapors of the nitrogen sheath gas, which surrounds the nebulizer spray, leads to an increase in the spray current. This is attributed to an increase in the electrical conductivity of water-amine enriched solvent at the tip exit. Here, the increased current results in a generation of additional electrolytically produced OH(-) ions and a corresponding increase in the pH at the tip exit. Along the electrospray plume, the pH of the droplets increases due to both droplet evaporation and exposure to basic vapors from the seeded sheath gas. The pH evolution in the ESI plume obtained using pure and basic seeded sheath gas was correlated with the evolution of the charge state distribution observed in mass spectra of proteins, in the negative ion mode. Taking advantage of the Agilent Jet Stream source geometry, similar protein charge state distributions and ion intensities obtained with basic initial solutions, can be obtained using native solution conditions by seeding the heated sheath gas with basic vapors.  相似文献   

14.
An ion mobility spectrometer that can easily be installed as an intermediate component between a commercial triple-quadrupole mass spectrometer and its original atmospheric pressure ionization (API) sources was developed. The curtain gas from the mass spectrometer is also used as the ion mobility spectrometer drift gas. The design of the ion mobility spectrometer allows reasonably fast installation (about 1 h), and thus the ion mobility spectrometer can be considered as an accessory of the mass spectrometer. The ion mobility spectrometer module can also be used as an independently operated device when equipped with a Faraday cup detector. The drift tube of the ion mobility spectrometer module consists of inlet, desolvation, drift, and extraction regions. The desolvation, drift and extraction regions are separated by ion gates. The inlet region has the shape of a stainless steel cup equipped with a small orifice. Ion mobility spectrometer drift gas is introduced through a curtain gas line from an original flange of the mass spectrometer. After passing through the drift tube, the drift gas serves as a curtain gas for the ion-sampling orifice of the ion mobility spectrometer before entering the ion source. Counterflow of the drift gas improves evaporation of the solvent from the electrosprayed sample. Drift gas is pumped away from the ion source through the original exhaust orifice of the ion source. Initial characterization of the ion mobility spectrometer device includes determination of resolving power values for a selected set of test compounds, separation of a simple mixture, and comparison of the sensitivity of the electrospray ionization ion mobility spectrometry/mass spectrometry (ESI-IMS/MS) mode with that of the ESI-MS mode. A resolving power of 80 was measured for 2,6-di-tert-butylpyridine in a 333 V/cm drift field at room temperature and with a 0.2 ms ion gate opening time. The resolving power was shown to be dependent on drift gas flow rate for all studied ion gate opening times. Resolving power improved as the drift gas flow increased, e.g. at a 0.5 ms gate opening time, a resolving power of 31 was obtained with a 0.65 L/min flow rate and 47 with a 1.3 L/min flow rate for tetrabutylammonium iodide. The measured limits of detection with ESI-MS and with ESI-IMS/MS modes were similar, demonstrating that signal losses in the IMS device are minimal when it is operated in a continuous flow mode. Based on these preliminary results, the IMS/MS instrument is anticipated to have potential for fast screening analysis that can be applied, for example, in environmental and drug analysis.  相似文献   

15.
ESI and APCI ionization techniques in both negative and positive ion modes were evaluated for simultaneous LC-MS analysis of the four tocopherol homologues (alpha, beta, gamma and delta). The ESI and APCI ionization of tocopherols in positive ion mode was not efficient and proceeded via two competitive mechanisms, with the formation of protonated pseudo-molecular ions and molecular ions, which adversely influenced the repeatability of MS signal. Ionization in negative ion mode in both ESI and APCI was more efficient as it only produced target deprotonated pseudo-molecular ions. The APCI in negative ion mode showed larger linearity range, lower detection limits and was less sensitive to the differences in chemical structure of analytes and nature of applied solvents than negative ion ESI. Negative ion APCI was, therefore, chosen for the development of LC-MS method for simultaneous determination of the four tocopherols in foods. A baseline separation of the tocopherols was achieved on novel pentafluorophenyl silica-based column Fluophase PFP. The use of methanol-water (95:5, v/v) as a mobile phase was preferable to the use of acetonitrile-water due to considerable gain in MS signal. The limits of quantifications were 9 ng/mL for alpha-tocopherol, 8 ng/mL for beta- and gamma- and 7.5 ng/mL for delta-tocopherol when 2 microL was injected. This method was successfully applied to determination of tocopherols in sunflower oil and milk.  相似文献   

16.
微波诱导等离子体原子吸收光谱法测定锰的研究   总被引:1,自引:0,他引:1  
  相似文献   

17.
In recent years, the resolving power of ion mobility instruments has been increased significantly, enabling ion mobility spectrometry (IMS) to be utilized as an analytical separation technique for complex mixtures. In theory, decreasing the drift tube temperature results in increased resolution due to decreased ion diffusion. However, the heat requirements for complete ion desolvation with electrospray ionization (ESI) have limited the reduction of temperatures in atmospheric pressure ion mobility instruments. Micro-electrospray conditions were investigated in this study to enable more efficient droplet formation and ionization with the objective of reducing drift tube temperatures and increasing IMS resolution. For small molecules (peptides), the drift tube temperature was reduced to ambient temperature with good resolution by employing reduced capillary diameters and flow rates. By employing micro-spray conditions, experimental resolution values approaching theoretically predicted resolution were achieved over a wide temperature range (30 to 250 °C). The historical heat requirements of atmospheric pressure IMS due to ESI desolvation were eliminated due to the use of micro-spray conditions and the high-resolution IMS spectra of GLY-HIS-LYS was obtained at ambient temperature. The desolvation of proteins (cytochrome c) was found to achieve optimal resolution at temperatures greater than 125 °C. This is significantly improved from earlier IMS studies that required drift tube temperatures of 250°C for protein desolvation.  相似文献   

18.
A quantitative method was developed for the determination of phosphatidylcholine (PC) species concentration using nanoflow LC-ESI-MS/MS. In this study, a calibration method is developed to determine the effect of PC carbon chain length on MS peak intensity. Using the multiple standard addition method, a relationship between the peak intensities of different PC species from nanoflow LC-MS and carbon chain length is established first using different injection amounts of PC standards. From this relationship, a calibration curve for each carbon chain length can be obtained for the concentration calculation. It was found that the MS peak area of PC species analyzed by nanoflow LC-MS linearly decreased with increased acyl carbon numbers, and that the effect of the degree of acyl chain unsaturation on MS peak intensity was minimized when the injection amount was maintained at less than 1 pmol. The method was applied for the quantitative calculation of 34 PC species from rat liver, which were identified from data-dependent MS/MS analysis during nanoflow LC separation.  相似文献   

19.
A supercritical fluid chromatography interface probe for atmospheric pressure ionisation mass spectrometry (API-MS) with the advantage of convenient switch between ionisation modes [atmospheric pressure chemical ionisation (APCI) and electrospray ionisation (ESI)] has recently been reported [P.J.R. Sj?berg, K.E. Markides, J. Chromatogr. A, 785 (1997) 101]. In order to obtain a stable ion signal and a low minimum detectable quantity, the design of the spray devise has to be optimised. For easy optimisation in the APCI mode, the corona needle was mounted directly on the interface probe. To compensate for the adiabatic cooling of the expanding mobile phase in the APCI mode, a heated region around the restrictor tip was used. In comparison, ESI required no additional heat, which might also prevent fragmentation for thermolabile compounds. As the mobile phase used was neat CO2, a low flow of make-up liquid was utilised in the ESI mode for transfer of the analytes from the expanding CO2 gas to the liquid phase before ionisation. The low make-up liquid flow in the ESI mode was sufficient for preventing the restrictor from becoming blocked. Factors that influence the ion signal intensity and stability have been studied. In APCI mode, corona needle position, nebuliser gas flow and gas additives were studied and in ESI mode, spray capillary assembly dimension and position, liquid flow-rate and composition were studied. The achievable detection limits were in the 50-0.1 pg (i.e., 290 fmol-140 amol) range. The detection limit in APCI mode was improved by a factor of about 20-25 compared to an earlier design [L.N. Tyrefors, R.X. Moulder, K.E. Markides, Anal. Chem. 65 (1993) 2835].  相似文献   

20.
A nebulizer-centric response function model of the analytical inductively coupled argon plasma ion source was used to investigate the statistical frequency distributions and noise reduction factors of simultaneously measured flicker noise limited isotope ion signals and their ratios. The response function model was extended by assuming i) a single gaussian distributed random noise source (nebulizer gas pressure fluctuations) and ii) the isotope ion signal response is a parabolic function of the nebulizer gas pressure.Model calculations of ion signal and signal ratio histograms were obtained by applying the statistical method of translation to the non-linear response function model of the plasma. Histograms of Ni, Cu, Pr, Tl and Pb isotope ion signals measured using a multi-collector plasma mass spectrometer were, without exception, negative skew. Histograms of the corresponding isotope ratios of Ni, Cu, Tl and Pb were either positive or negative skew. There was a complete agreement between the measured and model calculated histogram skew properties.The nebulizer-centric response function model was also used to investigate the effect of non-linear response functions on the effectiveness of noise cancellation by signal division. An alternative noise correction procedure suitable for parabolic signal response functions was derived and applied to measurements of isotope ratios of Cu, Ni, Pb and Tl. The largest noise reduction factors were always obtained when the non-linearity of the response functions was taken into account by the isotope ratio calculation.Possible applications of the nebulizer-centric response function model to other types of analytical instrumentation, large amplitude signal noise sources (e.g., lasers, pumped nebulizers) and analytical error in isotope ratio measurements by multi-collector plasma mass spectrometry are discussed.  相似文献   