1.
In this study positive ESI tandem mass spectra of the [M + H]+ ions of morphinan alkaloids obtained using an ion trap MS were compared with those from a triple quadrupole MS. This allows to assess the differences of the tandem-in-time versus the tandem-in-space principle, often hampering the development of ESI MS/MS libraries. Fragmentation pathways and possible fragment ion structures were discussed. In order to obtain elemental composition, accurate mass measurements were performed. According to the MS/MS fragmentation pathway, the investigated compounds can be grouped into 4 subsets: (1) morphine and codeine, (2) morphinone, codeinone, and neopinone, (3) thebaine and oripavine, (4) salutaridine and salutaridinol. Salutaridinol-7-O-acetate shows a different fragmentation behavior because of the favored loss of acetic acid. Although most fragment ions occur in both ion trap and triple quad tandem mass spectra, some are exclusively seen in either type. For triple quad, quadrupole time-of-flight and FT-ICR MS/MS, the base peak of morphine results from an ion at m/z 165 that contains neither nitrogen nor oxygen. This ion is not found in ion trap MS/MS, but in subsequential MS3 and MS4.  相似文献   

2.
Charged derivatives of peptides are useful in obtaining simpler collision-activated dissociation (CAD) mass spectra. An N-terminal charge-derivatizing reagent capable of reacting with picomole levels of peptide has been recently reported (Huang et al. Anal. Chem. 1997, 69, 137-144) in the contexts of analyses by fast atom bombardment (FAB) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Electrospray ionization (ESI) mass spectrometric investigation of these tris(trimethoxyphenylphosphonium) acetyl derivatives are described in this article, including studies by in-source fragmentation (ISF) and tandem mass spectrometry (MS/MS). Results from ISF are compared with those from MS/MS. Similarities and differences between ESI-ISF, MALDI-post-source decay (PSD), and FAB-CAD data are presented. Differences in fragmentation of these charged derivatives in the triple quadrupole and ion trap mass spectrometers also are discussed. Application of this derivatizing procedure to tryptic digests and subsequent analysis by liquid chromatography-mass spectrometry is also shown.  相似文献   

3.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
Triple quadrupole mass spectrometers are generally considered the instrument of choice for quantitative analysis. However, for the analysis of large peptides we have encountered some cases where, as the data presented here would indicate, ion trap mass spectrometers may be a good alternative. In general, specificity and sensitivity in bioanalytical liquid chromatography/mass spectrometry (LC/MS) assays are achieved via tandem MS (MS/MS) utilizing collision-induced dissociation (CID) while monitoring unique precursor to product ion transitions (i.e. selected reaction monitoring, SRM). Due to the difference in CID processes, triple quadrupoles and ion traps often generate significantly different fragmentation spectra of product ion species and intensities. The large peptidic analytes investigated here generated fewer fragments with higher relative abundance on the ion trap as compared to those generated on the triple quadrupole, resulting in lower limits of detection on the ion trap.  相似文献   

5.
The electrospray ionization (ESI) ion trap and quadrupole time-of-flight (QqToF) mass spectra of heroin and seven related alkaloids, i.e., morphine, codeine, O-6-monoacetylmorphine (6-MAM), thebaine, acetylcodeine, papaverine and narcotine, have been extensively investigated in this work. The ESI mass spectrometric fragmentation pathways of protonated 6-MAM, heroin, acetylcodeine, and thebaine were comprehensively elucidated for the first time with the aid of high-resolution mass spectrometry. It was found that cleavage of the piperidine ring was the featured fragmentation route of six of the compounds, although not of papaverine and narcotine. In addition, a simple high-performance liquid chromatography (HPLC)-based separation method gave baseline resolution of all eight components. This study could play an important role in the screening for these alkaloids in different matrices by HPLC coupled to tandem mass spectrometry (MS/MS).  相似文献   

6.
The use of a new hybrid quadrupole/linear ion trap known as the Q TRAP offers unique benefits as a LC-MS-MS detector for both small and large molecule analyses. The instrument combines the capabilities of a triple quadrupole mass spectrometer and ion trap technology on a single platform. Product ion scans are conducted in a hybrid fashion with the fragmentation step accomplished via acceleration into the collision cell followed by trapping and mass analysis in the Q3 linear ion trap. This results in triple quadrupole fragmentation patterns with no inherent low molecular mass cutoff. In-trap fragmentation is also possible in order to provide triple MS (MS3) capabilities. There are also several scan modes that are not possible on conventional instruments that enable identification of analytes within complex biological matrixes for subsequent high sensitivity product ion scans. This report will describe the new hybrid instrument and the principles of operation, and also provide examples of the unique scan modes and capabilities of the Q TRAP for LC-MS-MS detection in metabolism identification.  相似文献   

7.
In this study, different electrospray ionization mass spectrometric (ESI‐MS) methods were utilized to analyze several pairs of taxane stereoisomers including paclitaxel and 7‐epi‐paclitaxel. Both ESI‐MS and tandem mass spectrometry (MS/MS) techniques provided stereochemically dependent mass spectra in negative‐ion mode, and all studied stereoisomers could be easily distinguished based on their characteristic ions or distinct fragmentation patterns. MS/MS experiments for several taxane analogues at various collision energies were performed to elucidate potential dissociation pathways. The gas‐phase deprotonation potentials were also calculated to estimate the most thermodynamically favorable deprotonation site using DFT B3LYP/6‐31G(d). The results of the theoretical studies agreed well with the fragmentation patterns of paclitaxel and 7‐epi‐paclitaxel observed from MS/MS experiments. In addition, it was found that liquid chromatography (LC)/ESI‐MS was a useful and sensitive technique for assignment of C‐7 taxane stereoisomers from realistic samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
High-performance liquid chromatography-diode array detection (HPLC-DAD), electrospray ionization time-of-flight mass spectrometry (HPLC-ESI-TOF-MS) and electrospray ionization quadrupole ion trap mass spectrometry (HPLC-ESI-MSn) were used for the isolation, identification and structural analysis of water-soluble phenolic and nonpolar diterpenoid constituents in Dan-shen (Radix Salvia miltiorrhizae) which was prepared by sonication in 70% methanol. Mass spectra were obtained by ESI-TOF-MS and electrospray ionization quadrupole ion trap mass spectrometry (ESI-QIT-MS). A formula database of known constituents in Dan-shen was established and most constituents were rapidly identified by HPLC-DAD/ESI-TOF-MS by matching their accurate molecular masses with the formulae of the compounds in the database. Compounds with the same molecular formula could not be differentiated by TOF-MS; however, QIT-MS could differentiate those compounds and elucidate their structures based on their characteristic fragmentation. HPLC-DAD, HPLC/ESI-TOF-MS and HPLC/ESI-MSn provided complementary information for the identification of the constituents in Dan-shen. Forty constituents were identified in 30 min based on their positive and negative ion ESI mass spectra and liquid chromatographic information. Thus the method described is useful for the rapid analysis of multiple constituents in Dan-shen.  相似文献   

9.
This study has elucidated the fragmentation pathway for deprotonated isoflavones in electrospray ionization using MS(n) ion trap mass spectrometry and triple quadrupole mass spectrometry. Genistein-d(4) and daidzein-d(3) were used as references for the clarification of fragment structures. To confirm the relationship between precursor and product ions, some fragments were traced from MS(2) to MS(5). The previous literature for the structurally related flavones and flavanones located the loss of ketene (C(2)H(2)O) to ring C, whereas the present fragmentation study for isoflavones has shown that the loss of ketene occurs at ring A. In the further fragmentation of the [M-H-CH(3)](-*) radical anion of methoxylated isoflavones, loss of a hydrogen atom was commonly found. [M-H-CH(3)-CO-B-ring](-) is a characteristic fragment ion of glycitein and can be used to differentiate glycitein from its isomers. Neutral losses of CO and CO(2) were prominent in the fragmentation of deprotonated anions in ion trap mass spectrometry, whereas recyclization cleavage accounted for a very small proportion. In comparison with triple quadrupole mass spectrometry, ion trap MS(n) mass spectrometry has the advantage of better elucidation of the relationship between precursor and product ions.  相似文献   

10.
Isopropylthioxanthone (ITX), usually applied as a mixture of 2- and 4-isomers, is a common photo-initiator in UV inks used in paper- or plastic-based packaging materials. In this work a pentafluorophenylpropyl column (HS F5) has been used to achieve the chromatographic separation of the two isomers. A gradient elution with acetonitrile and a 25mM formic acid-ammonium formate at pH 3.75 are required to provide an Rs of 1.3 between the two compounds. The fragmentation pattern of ITX was studied using two mass analyzers, an ion trap (IT) (multi-stage fragmentation) and a triple quadrupole mass analyzer of hyperbolic rods (accurate mass (AM) measurement). The protonated molecule [M+H](+) observed in the mass spectrometry (MS) spectrum lost an isopropyl group, [M+H-C(3)H(6)](+). Later, this ion fragmented, yielding the radical ion [M+H-C(3)H(6)-CHO](+). The elemental composition of these product ions was confirmed by AM measurement. Electrospray ionization (ESI) was used as an ionization source to couple liquid chromatography (LC) to MS. Instrumental quality parameters of three acquisition modes provided by the triple quadrupole mass analyzer were studied and good run-to-run precision (relative standard deviation, RSD, lower than 10%) and limits of detection (LODs) down to 0.8pg injected in the LC-MS/MS system were obtained. Finally the LC-MS/MS method using H-SRM Q1 acquisition mode was used to analyze 2- and 4-ITX in a range of food samples. The use of highly selective selected reaction monitoring (H-SRM on Q1) resulted in improved selectivity without sensitivity loss.  相似文献   

11.
The curcuminoids are a group of diarylheptanoid molecules that possess important pharmacological activities, particularly acting as anti-inflammatory agents. The main purpose of this study was to investigate the fragmentation behavior of the three major curcuminoids in ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS). Both positive and negative mode electrospray ionization in tandem and multidimensional MS(n) experiments in quadrupole ion trap instruments and high-resolution and accurate mass MS and sustained off-resonance irradiation (SORI) MS/MS experiments in a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer were used to elucidate the main fragmentation channels of these compounds. These experiments yielded essentially the same fragmentation results in both ion trap and ICR instruments for all three curcuminoids and for their phenolic monoacetates. Major and diagnostic fragment ions were identified and their origins are proposed.  相似文献   

12.
The performance of three different types of mass spectrometers (MS) coupled to high performance liquid chromatography (HPLC) was compared for trace analysis of perfluoroalkylated substances (PFAS) and fluorotelomer alcohols (FTOHs). Ion trap MS in the full scan and product ion MS2 mode, time-of-flight (TOF) high resolution MS and quadrupole MS in the selected ion mode as well as triple quadrupole tandem MS were tested. Electrospray ionisation in the negative ion mode [ESI-] was best suited for all instruments and compounds. PFAS could only be separated by a buffered mobile phase, but the presence of buffer suppressed the ionisation of FTOHs. Therefore, two independent chromatographic methods were developed for the two compound classes. Mass spectra and product ion spectra obtained by in-source and collision induced dissociation fragmentation are discussed including ion adduct formation. Product ion yields of PFAS were only in the range of 0.3 to 12%, independent from the applied MS instrument. Ion trap MS2 gave product ion yields of 20 to 62% for FTOHs, whereas only 4.1 to 5.8% were obtained by triple quadrupole tandem MS. Ion trap MS was best suited for qualitative analysis and structure elucidation of branched isomeric structures of PFAS. Providing typical detection limits of 5 ng injected in MS2 mode, it was not sensitive enough for selective trace amount quantification. TOF high resolution MS was the only technique combining high selectivity and excellent sensitivity for PFAS analysis (detection limits of 2 to 10 pg), but lacked the possibility of MS-MS. Triple quadrupole tandem MS was the method of choice for quantification of FTOHs with detection limits in the low pg range. It is also well suited for the determination of PFAS, though its detection limits of 10 to 100 pg in tandem MS mode are about one order of magnitude higher than for TOF MS.  相似文献   

13.
In the present study, a methodology based on liquid chromatography with diode array detection (HPLC/DAD) coupled to an electrospray ionization (ESI) interface and a triple quadrupole mass spectrometer for the simultaneous identification of phenolic compounds in fruit juices has been developed. 72 available phenolic compound standards from diverse families present in fruits have been studied in order to analyze their fragmentation pattern. As a result, a general strategy for the characterization of unknown phenolic compounds in fruit juices was designed: (i) taking into account its UV–visible spectrum and elution order, assign the unknown polyphenol to a polyphenol class, (ii) identify the quasi-molecular ion using positive and negative MS spectra, being supported by adducts generated with solvent or sodium and molecular complexes, (iii) determinate the pattern of glycosylation in positive mode using ESI(+)-CID MS/MS product ion scan experiments, selecting the quasi-molecular ion as precursor ion, and finally, (iv) study the identity of the aglycone through ESI(+)-CID MS/MS product ion spectra from the protonated aglycone, [Y0]+. This strategy was successfully employed for the characterization of known and unknown phenolic compounds in juices from 17 different fruits.  相似文献   

14.
Two mass spectrometers, in parallel, were employed simultaneously for analysis of triacylglycerols in canola oil, for analysis of triolein oxidation products, and for analysis of triacylglycerol positional isomers separated using reversed-phase high-performance liquid chromatography. A triple quadrupole mass spectrometer was interfaced via an atmospheric pressure chemical ionization (APCI) interface to two reversed-phase liquid chromatographic columns in series. An ion trap mass spectrometer was coupled to the same two columns using an electrospray ionization (ESI) interface, with ammonium formate added as electrolyte. Electrospray ionization mass spectrometry (ESI-MS) under these conditions produced abundant ammonium adduct ions from triacylglycerols, which were then fragmented to produce MS/MS spectra and then fragmented further to produce MS/MS/MS spectra. ESI-MS/MS of the ammoniated adduct ions gave product ion mass spectra which were similar to mass spectra obtained by APCI-MS. ESI-MS/MS produced diacylglycerol fragment ions, and additional fragmentation (MS/MS/MS) produced [RCO](+) (acylium) ions, [RCOO+58](+) ions, and other related ions which allowed assignment of individual acyl chain identities. APCI-MS of triacylglycerol oxidation products produced spectra like those reported previously using APCI-MS. APCI-MS/MS produced ions related to individual fatty acid chains. ESI-MS of triacylglycerol oxidation products produced abundant ammonium adduct ions, even for those molecules which previously produced little or no intact molecular ions under APCI-MS conditions. Fragmentation (MS/MS) of the [M+NH(4)](+) ions produced results similar to those obtained by APCI-MS. Further fragmentation (MS/MS/MS) of the diacylglycerol fragments of oxidation products provided information on the oxidized individual fatty acyl chains. ESI-MS and APCI-MS were found to be complementary techniques, which together contributed to a better understanding of the identities of the products formed by oxidation of triacylglycerols.  相似文献   

15.
Three liquid chromatography-electrospray ionisation (LC-ESI) MS systems are evaluated for the analysis of heterocyclic amines (HAs). The electrospray sources and analysers (ion trap, single quadrupole and triple quadrupole) have been compared in terms of performance and quality parameters. In all cases, a C8 reversed-phase column and (acetic acid-ammonium acetate 30 mM pH 4.5)-acetonitrile (ACN) as mobile phase were used. Ionisation source parameters, post-column addition and working conditions for each acquisition mode (full scan, product ion scan, selected ion monitoring, and multiple reaction monitoring) were optimised for each instrument. The MS-MS spectra obtained with the ion trap and the triple quadrupole systems were very similar in both fragment ions and relative abundances, except for carbolines that showed adduct formation in the ion trap. Quality parameters were established and good precision (relative standard deviations (R.S.D.) < 12%) and very low limits of detection were obtained, mainly when using the triple quadrupole (< 9 pg injected). The content of HAs in a lyophilised beef extract was determined using the three instruments in order to compare their applicability for routine HAs analysis.  相似文献   

16.
Anabolic steroids are structurally similar compounds, and their product-ion spectra obtained by tandem mass spectrometry under electrospray ionization conditions are quite difficult to interpret because of poly-ring structures and lack of a charge-retaining center in their chemical structures. In the present study, the fragmentation of nine anabolic steroids of interest to the racing industry was investigated by using triple quadrupole mass spectrometer, Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer, and a linear ion trap instrument. With the aid of an expert system software (Mass Frontier version 3.0), accurate mass measurements, and multiple stage tandem mass spectrometric (MS(n)) experiments, fragmentation pathways were elucidated for boldenone, methandrostenolone, tetrahydrogestrinone (THG), trenbolone, normethandrolone and mibolerone. Small differences in the chemical structures of the steroids, such as an additional double-bond or a methyl group, result in significantly different fragmentation pathways. The fragmentation pathways proposed in this paper allow interpretation of major product ions of other anabolic steroids reported by other researchers in a recent publication. The proposed fragmentation pathways are helpful for characterization of new steroids. The approach used in this study for elucidation of the fragmentation pathways is helpful in interpretation of complicated product-ion spectra of other compounds, drugs and their metabolites.  相似文献   

17.
The fragmentation mechanism of simvastatin and lovastatin was investigated using both triple quadrupole and ion trap mass spectrometers. The elimination of the ester side-chain followed by dehydration and dissociation of the lactone moiety were observed as the main fragmentation pathways for both compounds. Another major fragmentation process was a C==C double-bond facilitated rearrangement. Our tandem mass spectrometric (MS/MS) data suggested that the beta-hydroxy group was involved in the fragmentation by interacting with the carboxyl group generated from the ring opening of the lactone. As a result, a facile neutral loss of 60 Da (CH(3)COOH or a combination of CH(2)==C==O and H(2)O) was detected. MS/MS studies of the structural analogs also provided evidence that the dehydration of the beta-hydroxy lactone generated preferentially the beta,gamma-unsaturated lactones.  相似文献   

18.
The use of electrospray ionization (ESI) quadrupole ion trap mass spectrometry and reversed-phase high-performance liquid chromatography (HPLC) for the characterization of 2-aminobenzamide (2AB)-labeled oligosaccharides and N-linked protein oligosaccharide mixtures is described. The major signals were obtained under these conditions from the [M+Na]+ ions for all 2AB-derivatized oligosaccharides. Under collision-induced dissociation, sodiated molecular species generated in the ESI mode yield simple and predictable mass spectra. Tandem mass spectrometry (MS/MS) experiments with orders higher than two offer a number of ways to enhance MS/MS spectra and to derive information not present in MS and MS2 spectra. Information on composition, sequence, branching and, to some extent, interglycosidic linkages can be deduced from fragments resulting from the cleavage of glycosidic bonds and from weak cross-ring cleavage products. Reversed-phase HPLC and derivatization by reductive amination using 2-aminobenzamide were finally applied to characterize a glycan pool enzymatically released from glycoproteins.  相似文献   

19.
Liquid chromatography coupled to negative electrospray ionization (ESI) tandem mass spectrometry (MS/MS) employing a triple quadrupole mass spectrometer was used in the structural determination of acylated flavonoid-O-glycosides and methoxylated flavonoids occurring in Tagetes maxima. The compounds were identified by experiments in full scan mode (MS), and tandem mass experiments (MS/MS) of precursor ion scan, product ion scan, and neutral loss scan modes. In order to characterize the aglycones of the flavonoid glycosides, in-source fragmentation of the deprotonated molecule [M-H]- followed by product ion scan of the resulting aglycone [A-H]- were performed. This combined approach allowed the identification of 51 phenolic compounds, including flavonoid-O-glycosides acylated with galloyl, protocatechuoyl, coumaroyl or caffeoyl groups, methoxylated flavonoids, and hydroxycinnamic acid and phenolic acid derivatives, none of them previously reported in Tagetes maxima.  相似文献   

20.
Capillary liquid chromatography (LC) using a 320 microns column and a flow rate of 10 microL/min has been coupled to an ion trap mass spectrometer using electrospray ionisation (ESI) to enable the rapid and effective identification of metabolites in urine, following oral administration of a novel human neutrophil elastase inhibitor, GW311616. Metabolites were identified from their mass (MS) spectra and tandem (MS/MS) mass spectra using minimal sample (1 microL of urine) and no sample pretreatment. Sensitivity assessment has shown that both molecular weight and structural information is obtainable on as little as 5 pg of compound, making the capillary LC/ion trap system as described an ideal analytical tool for the detection and characterisation of low level metabolites in biofluids (particularly when sample volume is limited). This level of detection was unattainable using a triple quadrupole mass spectrometer operating in full-scan mode, although 200 fg on column was detected using selected reaction monitoring target analysis.  相似文献   