1.
A method for identifying carbohydrates (mono-, di- and trisaccharides) in honey is presented. It is based on the separate preparation of both trimethylsilyl ethers and oxime trimethylsilyl ethers of the sugars followed by their gas chromatographic separation on a fused-silica capillary column coated with OV-101 using temperature programming. From the two chromatograms, the number of peaks given by each derivatized sugar, their relative retention times and peak-area ratios are used for identification. The identities of two unidentified trisaccharide peaks are considered. Quantitative applications to honey sugar analysis are discussed.  相似文献   

2.
A gas chromatographic system for the evaluation of linear temperature-programmed retention indices allowing n-alkanes to be adopted as the reference retention markers for any type of analyte, irrespective of the atoms present in their molecules, is described. It is based on the simultaneous use of two different detectors (a flame ionization detector and a specific detector suitable for the sample components), both connected (in parallel) to the same column outlet. The performance of this system has been tested by measuring the retention indices of fifteen chlorinated pesticides under conditions of linear programming temperature, by adopting an electron-capture detector as the specific detector. The reliability of the retention indices thus determined has been proven by verifying that they can be reproduced under different chromatographic conditions.  相似文献   

3.
Summary This paper proposes an optimization model for gas-solid chromatographic separations in a non-linear programming form and an approximate equation of the plate height for the model. A computer-modified mapping procedure is also described for searching the optimum separation conditions. Just five experiments and about 20 minutes of the computer time are needed to establish the optima of column temperature and of the carrier gas linear velocity. The relative deviation between the predicted and the experimental values was found to be within 20% for the plate heights, and within 1.5% for the retention times.  相似文献   

4.
A method for the prediction of the retention time and the resolution of chromatographic peaks in different experimental conditions by starting from few experimental data measured in isothermal and isobaric analyses was published previously. In this paper, the same mathematical model was implemented for calculating the retention times and the column efficiency in programmed pressure runs. Some models originated from the Golay equation and reported in the literature are compared, and a new modified equation for the calculation of the peak width at half height is proposed. The procedure for the prediction of the retention time and the peak width at half height at programmed pressure of the carrier gas and different column temperature and linear gradient by using retention data of different compounds obtained in few isobaric runs is described. The prediction of the retention time and the separation efficiency of compounds with different polarity gave good results for the programmed pressure runs with linear gradient. The effect of the variation of the initial parameters of the experimental analyses and of the mathematical model on the accuracy of the prediction has been evaluated.  相似文献   

5.
Narcotic analgesics of the fentanyl class are characterized by high potency and relatively short duration of action. These compounds nowadays have become a substitute for heroine and are highly addictive for abusers. Herein, we report retention indices of fentanyl and its eighteen analogues relative to the homologous n-alkane series. These values are determined on a moderately polar BP-5 capillary column under programmed temperature and isothermal chromatographic conditions. The analogues differ in the substituent attached to the piperidine ring nitrogen, and retention indices are found to vary according to the nature of the substituent. The effects of chromatographic conditions like temperature programming rate, carrier gas flow rate, and oven temperature are studied. Retention indices are also determined on a non-polar BP-1 column to study the influence of stationary phase polarity. Standard deviation of all the RI values is less than one index unit.  相似文献   

6.
The simultaneous temperature and inlet pressure programming (TPP) in gas chromatographic analysis decreases the retention time and the maximum value of temperature required for the elution of high boiling substances. Therefore, compounds sensitive to thermal degradation can be better analysed and column ageing is reduced. However, the empirical choice of proper analysis conditions requires many preliminary runs; this paper describes a procedure for the theoretical prediction of retention times in TPP using few preliminary runs carried out in isobaric and isothermal conditions. The used program permits the prediction of the retention times of the compounds analysed with any different TPP run carried out within the temperature and pressure ranges investigated with the preliminary runs. The influence of various analytical parameters on the accuracy of the prediction values was investigated. The proposed model also predicts the relative position in the chromatogram of closely eluting peaks and the possible coincidence of retention times or inversion of the elution order with changing temperature. It is also possible to foresee the analytical conditions, which offer a baseline separation of all of the peaks of the sample.  相似文献   

7.
The models proposed by many authors for the prediction of retention times and temperatures, peak widths, retention indices and separation numbers in programmed temperature and pressure gas chromatography by starting from preliminary measurements of the retention in isothermal and isobaric conditions are reviewed. Several articles showing the correlation between retention data and thermodynamic parameters and the determination of the optimum programming rate are reported. The columns of different polarity used for the experimental measurement and the main equations, mathematical models and calculation procedures are listed. An empirical approach was used in the early models, followed by the application of thermodynamic considerations, iterative calculation procedures and statistical methods, based on increased computing power now available. Multiple column arrangements, simultaneous temperature and pressure programming, applications of two-dimensional and fast chromatography are summarised.  相似文献   

8.

A way of organizing and processing the results from gas–chromatographic experiments to obtain chromatographic retention characteristics for a fixed concentration of sorbate in the gas phase or on the surface of the sorbent is proposed and substantiated. The suitability and expediency of such retention characteristics for describing the sorption properties of inhomogenous sorbents is demonstrated using a wide variety of adsorbents of different natures (activated carbons, swelling and nonswelling polymers, silicas and their silver derivatives) as examples.

  相似文献   

9.
朱秀华 《分析化学》2000,28(8):1013-1016
用气相色谱以程序升温方式分析了重整生成汽油,并将各组分升温保留时间转换为恒温保留指数。以各组分在OV-1和SE-54固定相上,同一柱温下的保留指数差及在各柱上的温度系数为三因素进行斜交因子分析和本征矢量旋转,给出了重整生成汽油样品中烷烃、烯烃、环烷烃、芳烃值,经气相色谱-质谱分析验证了结果的正确性,为重整成成汽油样品中烃的类别分析提供了一种新方法。  相似文献   

10.
11.
用气相色谱以程序升温方式分析了石脑油 ,并将各组分程序升温保留时间转换为恒温保留指数。以各组分在OV -1和SE -54固定相上、同一柱温下的保留指数差及在各柱上的温度系数为3因素进行斜交因子分析和本征矢量旋转 ,给出了石脑油样品的族组成值 ,经色谱 -质谱仪分析验证了结果的正确性 ,为石脑油样品的族组成分析提供了一种新方法。  相似文献   

12.
Savings in analysis time in capillary GC have always been an important issue for chromatographers since the introduction of capillary columns by Golay in 1958. In laboratories where gas chromatographic techniques are routinely applied as an analytical technique, every reduction of analysis time, without significant loss of resolution, can be translated into a higher sample throughput and hence reduce the laboratory operating costs. In this contribution, three different approaches for obtaining fast GC separations are investigated. First, a narrow-bore column is used under conventional GC operating conditions. Secondly, the same narrow-bore column is used under typical fast GC conditions. Here, a high oven temperature programming rate is used. The third approach uses a recent new development in GC instrumentation: Flash-2D-GC. Here the column is placed inside a metal tube, which is resistively heated. With this system, a temperature programming rate of 100°/s is possible. The results obtained with each of these three approaches are compared with results obtained on a column with conventional dimensions. This comparison takes retention times as well as plate numbers and resolution into consideration.  相似文献   

13.
The essential oils extracted from three kinds of herbs were separated by a 5% phenylmethyl silicone (DB‐5MS) bonded phase fused‐silica capillary column and identified by MS. Seventy‐four of the compounds identified were selected as origin data, and their chemical structure and gas chromatographic retention times (RT) were performed to build a quantitative structure–retention relationship model by genetic algorithm and multiple linear regressions analysis. The predictive ability of the model was verified by internal validation (leave‐one‐out, fivefold, cross‐validation and Y‐scrambling). As for external validation, the model was also applied to predict the gas chromatographic RT of the 14 volatile compounds not used for model development from essential oil of Radix angelicae sinensis. The applicability domain was checked by the leverage approach to verify prediction reliability. The results obtained using several validations indicated that the best quantitative structure–retention relationship model was robust and satisfactory, could provide a feasible and effective tool for predicting the gas chromatographic RT of volatile compounds and could be also applied to help in identifying the compound with the same gas chromatographic RT.  相似文献   

14.
通过对部分含氧化合物(醇、酯、醛、酮)在不同固定相不同柱温下的849个样本的气相色谱保留指数值(RI)与其部分参数:拓扑指数(mQ)、定位基参数(Sox)、固定液极性值(CP)及柱温(T)建立定量结构-色谱保留相关(QSRR)模型。分别利用多元线性回归(MLR)、偏最小二乘回归(PLSR)、人工神经网络(ANN)建模,同时采用内部及外部双重验证的办法对所得模型稳定性能进行深入分析和检验,建模计算值、留一法(LOO)交互检验(CV)预测值和外部样本预测值的复相关系数Rcum、QLOO和Rext分别为0.9832、0.9829和0.9836(MLR);0.9832、0.9830和0.9836(PLSR);0.9910、0.9909和0.9900(ANN)。结果表明:所建定量结构保留关系(QSRR)模型具有良好的稳定性和预测能力,较好地揭示了含氧化合物(醇、酯、醛、酮)在不同色谱条件下气相色谱保留指数的变化规律。  相似文献   

15.
通过对184个烯烃类化合物在不同固定相不同柱温下的617个样本的气相色谱保留指数值(RI)与其部分参数:拓扑指数(mQ)、偶极矩(DPL)、固定液极性值(CP)及柱温(T)建立定量-色谱保留相关(QSRR)模型.分别利用多元线性回归(MLR)、偏最小二乘回归(PLSR)、人工神经网络(ANN)建模,同时采用内部及外部双重验证的办法对所得模型稳定性能进行深入分析和检验,建模计算值、留一法(LOO)交互检验(CV)预测值和外部样本的复相关系数Rcum,QLOO和Rext分别为0.999 2,0.998 4和0.999 2(MLR);0.999 0,0.998 0和0.999 1(PLSR);0.999 4,0.998 7和0.999 2(ANN).结果表明:所建定量结构保留关系(QSRR)模型具有良好的稳定性和预测能力,较好地揭示了烯烃类化合物在不同固定相不同柱温上气相色谱保留指数的变化规律.  相似文献   

16.
A procedure was developed for determination of metal traces in polypropylene on chromatographic sorbents and phases of various polarities. The thermal stability of volatile aluminum, chromium, and gallium acetylacetonates under the conditions of gas chromatography was studied. The influence exerted on the determination process by the column material, temperature, and polarity of phases was examined.  相似文献   

17.
Increasing the interlaboratory reproducibility of gas chromatographic retention indices requires avoiding measurements distorted by overloading effects. Several criteria of evaluating the limits of the mass overloading of gas chromatographic systems are compared and reconsidered. The criteria mostly appropriate for practical purposes are based on (i) the dependences of factors of peak broadening (ratio of peak height and its width) vs. amount of analyte injected into the chromatographic column and (ii) the dependence of parameters characterizing the peak distortion (asymmetry factor) vs. the amount of analyte. Both these criteria provide mutually comparable evaluations of the overloading limits for analytes of different polarity. At the same time, the dependence of retention indices vs. amounts of analyte injected in the chromatographic column cannot be recommended for overloading control, because the parameters of the corresponding linear regressions indicate temperature dependence. The interpretation of certain gas chromatographic anomalies requires the correct evaluation of overloading limits. For example, the unusual temperature dependence of retention indices of polar analytes on non‐polar stationary phases and the dependence of retention indices on ratio of amounts of target analytes and reference compounds.  相似文献   

18.
Molander P  Olsen R  Lundanes E  Greibrokk T 《The Analyst》2003,128(11):1341-1345
The impact of column inner diameter on chromatographic performance in temperature gradient liquid chromatography has been investigated in the present study. Columns with inner diameters of 0.32, 0.53, 3.2 and 4.6 mm were compared with respect to retention and efficiency characteristics using temperature gradients from 30 to 90 degrees C with temperature ramps of 1, 5, 10 and 20 degrees C min(-1). The columns were all of 15 cm length and were packed with 3 microm Hypersil ODS particles. Alkylbenzenes served as model compounds, and the mobile phase consisted of acetonitrile-water (50:50, v/v). The study revealed that the column ID is not a critical limiting factor when performing temperature programming in LC, at least for columns narrower than 4.6 mm inner diameter in the temperature interval 30-90 degrees C. The retention times for all components on all columns were highly comparable, with similar peak profiles without any signs of peak splitting. The use of mobile phase pre-heating when using the larger bore columns was avoided by starting the temperature gradients close to ambient. However, the relative apparent efficiency was inversely proportional to column inner diameter, making the capillary columns generally more functional towards temperature gradients than the larger bore columns with respect to chromatographic efficiency. In addition, the capillary columns possessed higher robustness towards temperature programming than the conventional columns.  相似文献   

19.
Linear-elution strength theory and temperature-programmed gas chromatography is evaluated as a rapid method for predicting isothermal retention factors and column selectivity. Retention times for a wide range of compounds are determined at the program rates of 3 and 12 °C/min for the temperature range 60 to 160 °C on three open-tubular columns (DB-1701, DB-210 and EC-Wax) and used to predict isothermal retention factors for each column over the temperature range 60 to 140 °C. The temperature-program predicted isothermal retention factors are compared with experimental values using linear regression and the solvation parameter model. It is shown that isothermal retention factors predicted by the linear-elution-strength model only approximately represents the experimental data. The model fails to predict the slight curvature that exists in most plots of the experimental retention factor (log k) as a function of temperature. In addition, regression of the temperature-program predicted isothermal retention factors against the experimental values indicates that the slopes and intercepts deviate significantly from their target values of one and zero, respectively, in a manner which is temperature dependent. The temperature-program predicted isothermal retention factors result in system constants for the solvation parameter model that are different to those obtained from the experimental retention factors. These results are interpreted as indicating that linear-elution-strength theory predicts retention factors that fail to accurately model stationary phase interactions over a wide temperature range. It is concluded that temperature-program methods using linear-elution-strength theory are unsuitable for constructing system maps for isothermal separations.  相似文献   

20.