首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the determination of lead in blood using a tungsten coil atomizer is described. A 100 μl volume of the whole blood sample is transferred to a sampler cup containing 100 μl of water plus 300 μl of 0.25% v/v Triton X-100. After lysis of blood cells, 500 μl of 10% w/v trichloroacetic acid is added for protein precipitation and 10 μl of the supernatant solution is automatically delivered into the tungsten coil. The furnace heating program is implemented in 41 s. It is shown by the paired t-test that there is no significant difference at the 5% probability level between results obtained by the proposed method and by using a transversely heated graphite atomizer with a longitudinal Zeeman background correction. Accuracy is also assessed by employing reference materials. The proposed tungsten coil procedure presents a characteristic mass of 15 pg Pb and a detection limit of 1.9 μg Pb dl−1.  相似文献   

2.
In this work it was evaluated the determination of Cd and Pb in mussels by tungsten coil electrothermal atomic absorption spectrometry (TCA-AAS). A critical and comprehensive study of the effects caused by Pd, Mg, ascorbic acid, and binary mixtures of these compounds on the atomization of Cd and Pb in acid digested solutions of mussels was performed. Palladium and mixtures containing it were useful to increase sensitivity and thermal stability of Cd and Pb. Additionally, the coil lifetime was increased and the background signals were decreased in these modifiers. All these favorable effects were analytically exploited to determine Cd and Pb in samples of mussels. The proposed methodology was validated using two certified reference materials (oyster tissue and mussel). No statistical difference was observed between determined and certified values at a 95% confidence level. Cadmium and Pb in Chilean bivalve mussels were determined by TCA and by graphite furnace-AAS. Again, the results showed statistical agreement.  相似文献   

3.
In this work, the microsampling nature of tungsten coil electrothermal vaporization Ar/H2 flame atomic fluorescence spectrometry (W-coil ETV-AFS) as well as tungsten coil electrothermal atomic absorption spectrometry (W-coil ET-AAS) was used with cloud point extraction (CPE) for the ultrasensitive determination of cadmium in rice and water samples. When the temperature of the extraction system is higher than the cloud point temperature of the selected surfactant Triton X-114, the complex of cadmium with dithizone can be quantitatively extracted into the surfactant-rich phase and subsequently separated from the bulk aqueous phase by centrifugation. The main factors affecting the CPE, such as concentration of Triton X-114 and dithizone, pH, equilibration temperature and incubation time, were optimized for the best extract efficiency. Under the optimal conditions, the limits of detection for cadmium by W-coil ETV-AFS and W-coil ET-AAS were 0.01 and 0.03 μg L−1, with sensitivity enhancement factors of 152 and 93, respectively. The proposed methods were applied to the determination of cadmium in certified reference rice and water samples with analytical results in good agreement with certified values.  相似文献   

4.
Palladium, iridium, and rhodium are evaluated as possible chemical modifiers in the determination of As in digest solutions of biological materials (human hair and clam) by tungsten coil electrothermal atomic absorption spectrophotometry (TCA-AAS). The modifier in solution was applied onto the coil and thermally pre-reduced; the pre-reduction conditions, the amount of modifier, and the thermal program were optimized. Palladium was not satisfactory, whereas Ir and Rh were effective modifiers and rendered better relative sensitivity for As by a factor of 1.4 and 1.9, respectively compared to the case without modifier. Upon optimization of thermal conditions for As in pre-reduced Ir (2.0 µg) and Rh (2.0 µg) modifiers and in the digest solutions of the study matrices, Rh (2.0 µg) was more effective modifier and was selected as such. The mean within-day repeatability was 2.8% in consecutive measurements (25–100 µg L–1) (3 cycles, each of n=6) and confirmed good short-term stability of the absorbance measurements. The mean reproducibility was 4.4% (n=20 in a 3-day period) and the detection limit (3 blank/slope) was 29 pg (n=15). The useful coil lifetime in Rh modifier was extended to 300–400 firings. Validation was by determination of As in the certified reference material (CRM) of Oyster tissue solution with a percentage relative error (E rel%) of 2% and percentage relative standard deviation (RSD%) of 3% (n=4), and by analytical recovery of As spiked in CRM of human hair [94±8% (n=4)]. The methodology is simple, fast (sample readout frequency 21 h–1), reliable, of low cost, and was applied to the determination of As in hair samples of exposed and unexposed workers.  相似文献   

5.
The determination of Cr in digest solutions of mussels and non-fat milk powder by tungsten coil electrothermal atomic absorption spectrophotometry (TC-ETAAS) is affected by interferences. This study reports a critical evaluation of chemical modifiers that could be employed to correct these interferences. The chemical modifiers tested were: Mg [as Mg(NO3)2], Pd [as Pd(NO3)2], NH4NO3, ascorbic acid, and mixtures of these compounds. The less effective modifier was NH4NO3. The best effects, considering thermal stabilization and sensitivity, were obtained in mixtures of ascorbic acid plus Mg. Chromium was determined by TC-ETAAS in certified reference materials of mussels and non-fat milk powder, and results were comparable with those obtained by graphite furnace atomic absorption spectrophotometry (GFAAS).  相似文献   

6.
The determination of Cr in digest solutions of mussels and non-fat milk powder by tungsten coil electrothermal atomic absorption spectrophotometry (TC-ETAAS) is affected by interferences. This study reports a critical evaluation of chemical modifiers that could be employed to correct these interferences. The chemical modifiers tested were: Mg [as Mg(NO3)2], Pd [as Pd(NO3)2], NH4NO3, ascorbic acid, and mixtures of these compounds. The less effective modifier was NH4NO3. The best effects, considering thermal stabilization and sensitivity, were obtained in mixtures of ascorbic acid plus Mg. Chromium was determined by TC-ETAAS in certified reference materials of mussels and non-fat milk powder, and results were comparable with those obtained by graphite furnace atomic absorption spectrophotometry (GFAAS). Received: 19 June 1998 / Revised: 11 January 1999 / Accepted: 16 January 1999  相似文献   

7.
Lima EC  Krug FJ  Nóbrega JA  Nogueira AR 《Talanta》1998,47(3):613-623
A method for ytterbium determination in animal faeces by tungsten coil electrothermal atomic absorption spectrometry (TCAAS) was developed. Faeces were dry-ashed in a muffle furnace, the ashes were treated with hydrochloric acid, and 10 mul of sample solution were delivered into 150-W tungsten coil atomizer. A matrix-matching procedure employing a 66-s heating program proved to be efficient for obtaining accurate results. Characteristic mass and detection limit were 7.1 pg and 0.35 mug g(-1) Yb, respectively. The tungsten coil atomizer lifetime exceeded 300 firings with digested solutions and R.S.D. of measurements was 1.9% after ten consecutive injections of 10.0 mug l(-1) Yb. Accuracy of the proposed method was assessed by employing a graphite furnace atomic absorption spectrometric procedure. Application of the paired t-test did not reveal any significant difference for ytterbium contents determined by both methods at 95% confidence level. It was demonstrated that the proposed procedure can successfully be used for evaluation of kinetic passage rate of feed through digestive tract of animals.  相似文献   

8.
A method was developed for the quantitative determination of total vanadium concentration in mussels via electrothermal atomic absorption spectrometry (ETAAS). After the microwave digestion of the samples, a program using temperatures of 1600 °C and 2600 °C for ashing and atomization respectively, without any matrix modifiers, allowed us to obtain results that were satisfactory since they agreed closely with certified reference material values. The detection limit was 0.03 mg kg–1 (dry weight), indicating that the method is suitable for the analysis of mussel samples. This determination was compared with matrix modifiers that have been reported previously. The method was applied to various cultivated and wild mussels from the Galician coast, yielding levels below 1 mg kg–1 (wet weight).  相似文献   

9.
Three platinum group elements (Pd, Ir and Rh) both in solution and in pre-reduced form, and also combined with Mg(NO3)2 or ascorbic acid, were assessed as possible chemical modifiers on the atomization of As in digest solutions of seafood matrices (clam and fish tissue) by tungsten coil electrothermal atomic absorption spectrometry (TCA-AAS) and compared without a modifier. Of 28 modifier alternatives in study including single form and binary mixtures, and based on maximum pyrolysis temperature without significant As loss and best As absorbance sensitivity during atomization, three modifiers: Rh (0.5 μg), Ir (1.0 μg) and Rh (0.5 μg) + ascorbic acid (0.5 μg), at optimum amounts were pre-selected and compared. The definitive modifier (rhodium (0.5 μg)) was selected by variance analysis. The mean within-day repeatability was 3% in consecutive measurements (25-300 μg l−1) (three cycles, each of n = 6) and showed good short-term stability of the absorbance measurements. The mean reproducibility was 4% (n = 18 in a 3-day period) and the detection limit (3σblank/slope) was 42 pg (n = 16). Quantitation was by standard additions to compensate for matrix effects not corrected by the modifier. Three sample digestion procedures were compared in fish and clam tissue samples: microwave acid digestion alone (A) or combined with the addition of 2% (m/v) K2S2O8 solution followed either by UV photo-oxidation (B) or re-digestion in a thermal block (C). The accuracy was established by determination of As in certified reference material of dogfish muscle (DORM-2). Procedures B and C showed good recoveries (102% (n = 4) and 103% (n = 7), respectively), whereas procedure A was not quantitative (85%). The methodology is simple, fast, reliable, of low cost and was applied to the determination of total As in lyophilized samples of clam and fish collected in the Chilean coast.  相似文献   

10.
A method for the determination of cadmium in slurries of marine sediment using palladium and phosphate as chemical modifier has been optimized. To stabilize the marine sediment slurry, Triton X-100 at 0.1% was used. To obtain a complete pyrolysis of the slurry sample two mineralization steps were used, the first at 480 °C and the second at 600 °C and 700 °C for phosphate and palladium, respectively. The precision and accuracy of the method have been studied by analyzing the Reference Material PACS-1 (marine sediment) of National Research Council Canada. The detection limits (LOD) were 11.9 g kg–1 for phosphate and 42.0 g kg–1 when palladium was used. These methods have been applied to the determination of cadmium in marine sediment samples from the Galicia coast and the results of both methods were compared; no significant differences were found between the two procedures.  相似文献   

11.
In this work, methodologies to determine manganese (Mn) in urine and whole blood by electrothermal atomic absorption spectrometry were developed. The use of Ru, Rh, and Zr as permanent modifiers, Pd as a modifier in solution, and the condition without modifier were investigated for the direct determination of Mn in urine and whole blood samples. The best results for Mn in urine and in whole blood were obtained without modifier use. The analytical characteristic, such as accuracy, precision and limit of detection of the proposed methodology were adequate.  相似文献   

12.
Tungsten coil atomizer atomic absorption spectrometry (TCAAS) was used to determine Dy and Eu in acid-digested faeces of sheep. These elements were used as markers in animal nutrition studies. Samples were dried, ground and decomposed using a nitric-perchloric acid mixture. The accuracy of the developed method was evaluated by graphite furnace atomic absorption spectrometry (GFAAS). The results obtained for Eu were validated at a 95% confidence level using a paired t-test. The results for Dy were not validated owing to memory effects caused by carbide formation into the graphite tube. This effect did not occur for Eu. The detection limits for Dy and Eu were 6.9 and 2.1 mug l(-1) by TCAAS, and 2.2 and 5.2 mug l(-1) by GFAAS, respectively. Relative standard deviations (R.S.D.; n=5) were 0.7-3.8 and 0.8-5.6% for Dy and Eu by TCAAS and 0.8-5.4 and 0.3-3.8% for Dy and Eu by GFAAS, respectively. The lifetime of the tungsten coil was around 200 heating cycles, which is three-fold higher than graphite tube lifetime. The proposed method can be used to determine the passage rate of feed through animal digestive tract.  相似文献   

13.
A flow injection system coupled to a tungsten coil electrothermal atomizer has been developed for on-line separation and preconcentration, using lead as a model element. The system utilizes three-way solenoid valves for sampling, buffering, washing and reconditioning solution management, and the resin column is inserted in the tip of the autosampler arm of a Varian GTA-96. The solenoid valves and tungsten coil power supply were controlled by a computer program written in Visual Basic, interfaced with the built-in Varian software. The system performance was tested by loading the resin column with the sample flowing at 3 ml min−1 for 60 s. Elution was performed automatically by sampling 20 μl of the eluent from a sample cup of the autosampler, and this aliquot was delivered into a 150 W tungsten coil. With Chelex-100 resin, the separation of concomitants was tested with lead in the presence of as much as 1000 mg l−1 of Ca, Mg, Na or K. The model system presented an enrichment factor of 64 at a sampling rate of 30 samples per hour.  相似文献   

14.
电沉积-钨丝电热原子吸收光谱法测定水样中的铅   总被引:1,自引:0,他引:1  
研制了一种便携式钨丝电热原子吸收光谱分析装置,其主要包括:钨丝电热原子化器、多道微型CCD光谱仪、仪器电源系统以及控制系统。并将电沉积分离富集技术与该钨丝电热原子吸收光谱分析仪器结合,完成环境水样中铅的现场分析。并对铅的电沉积条件作了研究,最佳电沉积电位为负650 mV(vs.SCE),方法检出限:0.20μg/L,线性范围:1~15μg/L,对4μg/L Pb标准溶液10次重复测试,RSD为4.4%。  相似文献   

15.
This work describes an analytical procedure for vanadium determination in human hair slurries by electrothermal AAS using longitudinal heating (LHGA) and transversal heating (THGA) graphite furnace atomizers. The samples were powdered using cryogenic grinding and the hair slurries containing 0.2% (m/v) were prepared in three different media for determination of vanadium: 0.14 mol L−1 HNO3, 0.1% (v/v) Triton X-100 and 0.1% (v/v) water soluble tertiary amines (CFA-C, pH 8). The limits of detection (LOD), limits of quantification (LOQ), and characteristic masses obtained were 0.28, 0.95 μg L−1 and 35 pg (LHGA) and 0.34, 1.13 μg L−1 and 78 pg (THGA), respectively. The accuracy of the analytical results obtained by the proposed procedure in both equipments was confirmed by a paired t-test at the 95% confidence level and compared with a conventional procedure based on acid digestion.  相似文献   

16.
17.
The applicability of a DETATA sorbent to the preconcentration of lead and cadmium followed by the determination of these elements in urine using atomic absorption spectrometry with electrothermal atomization was demonstrated. After preconcentration by a factor of 10, the limits of detection were 0.01 and 0.2 μg/L for cadmium and lead, respectively. The accuracy of the results was supported by the analysis of Seronorm Trace Elements Urine (Batch no. 101021).  相似文献   

18.
Pereira LA  Amorim I  da Silva JB 《Talanta》2006,68(3):771-775
A procedure for the determination of cadmium, chromium, and lead in marine sediment slurries by electrothermal atomic absorption spectrometry is proposed. Slurry was prepared by mixing 10 mg of ground sample with particle size smaller than 50 μm completed to the weight of 1.0 g with a 3% nitric acid and 10% hydrogen peroxide solution. The slurry was maintained homogeneous with an aquarium air pump. For cadmium, the best results were obtained using iridium permanent with optimum pyrolysis and atomization temperatures of 400 and 1300 °C, respectively, a characteristic mass, mo (1% absorption), of 2.3 pg (recommended 1 pg). Without modifier use, zirconium, ruthenium, and rhodium mo were 3.4, 4.1, 4.6, and 4.8 pg, respectively. For chromium, the most sensitive condition was obtained with zirconium permanent with optimum pyrolysis and atomization temperatures of 1500 and 2500 °C, mo of 6.6 pg (recommended 5.5 pg); and without modifier use, rhodium, iridium, and ruthenium mo were 5.3, 8.8, 8.8, and 8.9 pg, respectively. For lead, the best modifier was also zirconium, mo of 8.3 pg for the optimum pyrolysis and atomization temperatures of 600 and 1400 °C, respectively, (recommended mo of 9.0 pg). For iridium, ruthenium, without modifier, and rhodium, mo were 14.7, 15.5, 16.5, and 16.5 pg, respectively. For all the modifiers selected in each case, the peaks were symmetrical with r2 higher than 0.99. Being analyzed (n = 10), two marine sediment reference materials (PACS-2 and MESS-2 from NRCC), the determined values, μg l−1, and certified values in brackets, were 2.17 ± 0.05 (2.11 ± 0.15) and 0.25 ± 0.03 (0.24 ± 0.01) for cadmium in PACS-2 and MESS-2, respectively. For chromium in PACS-2 and MESS-2 the values were 94.7 ± 5.6 (90.7 ± 4.6) and 102.3 ± 10.7 (106 ± 8), respectively. Finally, for lead in PACS-2 and MESS-2, the results obtained were 184 ± 7 (183 ± 8) and of 25.2 ± 0.40 (21.9 ± 1.2), respectively. For cadmium and lead in both samples and chromium in PACS-2, calibration was accomplished with aqueous calibration curves. For chromium in MESS-2, only with the standard addition technique results were in agreement with the certified ones. The limits of detection (k = 3, n = 10) obtained with the diluents were 0.1, 3.4, and 3.6 μg l−1 for cadmium, chromium, and lead, respectively.  相似文献   

19.
Permanent chemical modifiers have been shown to prolong graphite tube lifetime while reducing the furnace cycle time, thus improving cost-effectiveness. In this work, iridium is used as a permanent chemical modifier for the first time in the determination of selenium by tungsten-coil atomic absorption spectrometry (W-Coil AAS). The iridium modifier is thermally coated onto the tungsten coil. After coating, the coil can be used for 300–400 firings without further application of the modifier. Thermal treatment with iridium permits operating with higher pyrolysis temperature and coil lifetime is extended up to 1600 firings. The sensitivity and linearity of the method is improved, and the analytical procedure allows the use of analyte solutions containing up to 8% nitric acid. The short-term stability of the absorbance measurements is demonstrated by the reproducibility in the measurements of a Se amount (6 ng) 30 times higher than the limit of detection (0.2 ng). A 7% relative standard deviation (R.S.D.) was observed for 10 consecutive measurements of 6 ng Se. The long-term stability is almost as good: less than 9% R.S.D. over a 3-week period and 1500 firings. The surface of the tungsten-coil treated with iridium is examined before and after intensive use by scanning electron microscopy. Finally, the thermal treatment of the tungsten-coil with iridium appears to delay the appearance of selenium atoms by approximately 0.2 s although the integrated absorbance measurements are unaffected. The magnitude of delay decreases with coil age.  相似文献   

20.
超声辅助萃取-钨丝电热原子吸收光谱法测定痕量镉   总被引:5,自引:2,他引:3  
镉对人体和动植物而言是一种非必需的元素,当其含量超过一定浓度就会产生毒性.由于镉在生物体内的半衰期长达1年之久,一旦进入生物体就不易排出.因此,测定食物样品中的镉对保证人类和动物的健康有重要的意义[1].  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号