 共查询到20条相似文献,搜索用时 62 毫秒
1.
Tungsten coil atomizer atomic absorption spectrometry (TCAAS) was used to determine Dy and Eu in acid-digested faeces of sheep. These elements were used as markers in animal nutrition studies. Samples were dried, ground and decomposed using a nitric-perchloric acid mixture. The accuracy of the developed method was evaluated by graphite furnace atomic absorption spectrometry (GFAAS). The results obtained for Eu were validated at a 95% confidence level using a paired t-test. The results for Dy were not validated owing to memory effects caused by carbide formation into the graphite tube. This effect did not occur for Eu. The detection limits for Dy and Eu were 6.9 and 2.1 mug l(-1) by TCAAS, and 2.2 and 5.2 mug l(-1) by GFAAS, respectively. Relative standard deviations (R.S.D.; n=5) were 0.7-3.8 and 0.8-5.6% for Dy and Eu by TCAAS and 0.8-5.4 and 0.3-3.8% for Dy and Eu by GFAAS, respectively. The lifetime of the tungsten coil was around 200 heating cycles, which is three-fold higher than graphite tube lifetime. The proposed method can be used to determine the passage rate of feed through animal digestive tract.  相似文献   

2.
Three chemical modifiers ((NH(4))(2)HPO(4), NH(4)H(2)PO(4), and Pd as Pd(NO(3))(2)) were evaluated for the determination of Cd in acid-digested solutions of hair and blood using electrothermal atomic absorption spectrometry in a tungsten coil atomizer (TCA). All modifiers caused some thermal stabilization of Cd when compared to the behavior observed in nitric acid medium. The best effects were observed in 15 mug ml(-)(1) Pd medium; the characteristic mass of Cd was 0.3 pg and the method detection limits were 0.009 mug g(-)(1) in hair and 0.2 mug l(-)(1) in blood. In addition to a slight thermal stabilization effect, Pd also increased the sensitivity for Cd by ca. 40% and the tungsten coil lifetime by 20% (i.e. from 300 to 360 heating cycles), reduced background signals, and eliminated condensed phase interferences caused by concomitants. The accuracy (3.2% as mean relative error in the Pd modifier) was checked for the determination of Cd in acid-digested solutions of certified reference materials of human hair and blood and by recoveries of Cd in spiked hair and blood samples by both TCA and a graphite furnace procedure. All results obtained in chemical modifiers are in agreement at a 95% confidence level.  相似文献   

3.
A method for the determination of lead in blood using a tungsten coil atomizer is described. A 100 μl volume of the whole blood sample is transferred to a sampler cup containing 100 μl of water plus 300 μl of 0.25% v/v Triton X-100. After lysis of blood cells, 500 μl of 10% w/v trichloroacetic acid is added for protein precipitation and 10 μl of the supernatant solution is automatically delivered into the tungsten coil. The furnace heating program is implemented in 41 s. It is shown by the paired t-test that there is no significant difference at the 5% probability level between results obtained by the proposed method and by using a transversely heated graphite atomizer with a longitudinal Zeeman background correction. Accuracy is also assessed by employing reference materials. The proposed tungsten coil procedure presents a characteristic mass of 15 pg Pb and a detection limit of 1.9 μg Pb dl−1.  相似文献   

4.
Electrothermal atomic absorption spectrophotometry of Al in a tungsten coil atomizer was evaluated and applied for its determination in hemodialysis fluid. The system was mounted on a Varian Spectra AA-40 spectrophotometer with continuum background correction and all measurements, in peak height absorbance, were done at 309.3 nm. The purge gas was a mixture of 90% Ar plus 10% H(2). Observation height, gas flow, drying, pyrolysis and atomization steps were optimized. The heating program was carried out by employing a heating cycle in four steps: dry, pyrolysis, atomization and clean. The determination of Al in hemodialysis solutions was performed by using a matrix-matching procedure. Al in hemodialysis solutions was determined by TCA and by electrothermal atomization with a graphite tube atomizer. There is no differences between results obtained by both methods at a confidence level of 95%. The characteristic mass of Al by using the TCA was 39 pg and the detection limit was 2.0 mug l(-1).  相似文献   

5.
A flow injection system was coupled to a tungsten coil electrothermal atomizer (150 W) for on-line separation and preconcentration of lead based on its electrochemical reduction on the atomizer surface. The electrochemical cell is built up inside the furnace by using a Pt flow-through anode and the atomizer itself as the flow-through cathode. The manifold and the tungsten coil power supply were controlled by a computer running a program written in Visual Basic, which was utilized in synchronism with the original software of the atomic absorption spectrometer. The flow-through anode (50 mm long, 0.7 mm i.d.) was inserted in tip of the autosampler arm by replacing the last section of the PTFE sample delivering tube. The tungsten coil atomizer and the counter electrode were easily connected to a d.c. power supply. An enrichment factor of 25 was obtained for lead after a 120-s electrodeposition for a sample flowing at 1.0 ml min−1. The method detection limit was 0.2 μg l−1 Pb and the R.S.D.<5% (n=10 for 5 μg l−1 Pb). Up to 2% m/v NaCl or KCl and 5% m/v CaCl2 or MgCl2 did not interfere on the separation and atomization of 5 μg l−1 Pb.  相似文献   

6.
A tungsten coil atomic emission spectrometer is described and evaluated. The system employs a single tungsten coil as a combined atomizer and excitation source for the determination of metals by atomic emission spectrometry. The tungsten coil is extracted from a 150 W, 15 V commercial slide projector light bulb. A simple, laboratory constructed, computer-controlled power supply provides a constant current to the coil. A high-resolution Czerny–Turner monochromator with a charge coupled device detector completes the system. Simultaneous, multi-element analyses are possible within a 4 nm spectral window. Eleven test elements are used to characterize the system: Al (396.1 nm), Co (353.0 nm), Cr (427.1 nm), Dy (404.6 nm), Ga (403.3 nm), K (404.4 nm), Mn (403.1 nm), Pb (405.8 nm), Rb (420.2 nm), Sc (404.8 nm), and Yb (398.7 nm). Tungsten coil atomic emission detection limits are reported for these elements for the first time: 0.02 ng Al, 0.7 ng Co, 0.003 ng Cr, 0.01 ng Dy, 0.7 ng Ga, 0.3 ng K, 0.04 ng Mn, 10 ng Pb, 0.07 ng Rb, 1 ng Sc, and 0.003 ng Yb. The precision for the new technique is better than 13% relative standard deviation for all metals at concentrations two orders of magnitude above the detection limit. Aluminum, Cr, Mn, and K are determined in a standard reference material (trace elements in water) after simple dilution with water, and found values varied from certified values by up to 26%. The average tungsten coil lifetime was found to be 265 heating cycles. The elimination of the external radiation source needed for atomic absorption measurements results in an emission system that could be quite portable.  相似文献   

7.
Wu P  Wen X  He L  He Y  Chen M  Hou X 《Talanta》2008,74(4):505-511
A tungsten coil electrothermal vaporizer (W-coil ETV) was coupled to an Ar/H(2) flame atomic fluorescence spectrometer for the determination of eight traditional hydride-forming elements (i.e., As, Bi, Ge, Pb, Sb, Se, Sn, and Te) as well as cadmium without chemical vapor generation. A small sample volume, typically 20muL, was manually pipetted onto the W-coil and followed by a fixed electric heating program. During the vaporization step, analyte was vaporized off the coil surface and swept into the quartz tube atomizer of AFS for further atomization and excitation of atomic fluorescence by a flow of Ar/H(2) gas, which was ignited to produce the Ar/H(2) flame. The tungsten coil electrothermal vaporizer and Ar/H(2) flame formed a tandem atomizer to produce reliable atomic fluorescence signals. Under the optimal instrumental conditions, limits of detection (LODs) were found to be better than those by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma optical emission spectrometry (ICP-OES) for all the nine elements investigated. The absolute LODs are better or equivalent to those by hydride generation atomic fluorescence spectrometry (HG-AFS). Possible scattering interferences were studied and preliminary application of the proposed method was also reported.  相似文献   

8.
An inexpensive, multielement atomic absorption spectrometer utilizing a tungsten coil atomizer has been developed. The novel optical arrangement employs three 60° beam combiners to blend the spectral output from four light sources such as electrodeless discharge lamps, or hollow cathode lamps, and then direct that output over an atomizer. This instrument uses an inexpensive tungsten coil atomizer that is extracted from a standard 150 W projector bulb. The temperature of the coil is computer-controlled by changing the voltage across the coil. A low voltage is first used to dry the sample then a higher voltage is used to atomize the sample. Simultaneous detection of the analyte absorption signals is accomplished using a charge-coupled device. The elements of interest in this study were Cd, Pb, and Cu. Near-line background correction was used to correct for nonspecific analyte absorption.  相似文献   

9.
Summary The possibilities of ET-AAS using the graphite furnace or the tungsten coil atomizer were compared by the trace As, Sb and Sn determination in the chloride-containing solution resulting after gold reduction with hydrazine. It was found that the tungsten coil atomizer tolerates higher concentrations of chloride ions than the conventional graphite furnace.  相似文献   

10.
The direct determination of chromium in urine by electrothermal atomic absorption spectrometry (ETAAS) using graphite tubes modified with tungsten is proposed. Modification of the graphite is made by tungsten electrodeposition over the whole surface atomizer followed by carbide formation by heating the tube inside its own furnace. For tungsten electrocoating, the graphite tube and a platinum electrode were connected to a power supply as cathode and anode, respectively, and immersed in a solution containing 2 mg of W in 0.1% v/v HNO3. Then, 5 V was applied between the electrodes during 20 min for tungsten electrodeposition over the whole atomizer. A SpectrAA 220 Varian atomic absorption spectrometer equipped with a deuterium background corrector was used throughout. Undiluted urine (20 μl) was delivered over the tungsten-treated tube and the chromium-integrated absorbance was measured after applying a suitable heating program with maximum pyrolysis at 1300 °C and atomization at 2500 °C. With electrodeposited tungsten modifier, the tube lifetime increased up to four times when compared to previous published methods for Cr determination in urine by ETAAS, reaching 800 firings. Method detection limit (3 S.D.) was 0.10 μg l−1, based on 10 integrated absorbance measurements of a urine sample with low Cr concentration. Two reference materials of urines (SRM 2670) from National Institute of Standards and Technology (NIST) were analyzed for method validation. For additional validation, results obtained from eight human urine samples were also analyzed in a spectrometer with Zeeman effect background correction.  相似文献   

11.
For electrothermal sample introduction, a commercially available tungsten boat atomizer for atomic absorption spectrometry (AAS) was transferred to a vaporizer for inductively coupled plasma atomic emission spectrometry (ICP-AES). The modification retained as much of the original design of the atomizer as possible, so that the apparatus could be switched easily between conventional tungsten boat furnace (TBF)-AAS and TBF-ICP-AES. By using this system, a procedure for the determination of vanadium and titanium in steel was investigated. The detection limits (S/N=3) of vanadium and titanium were 3.9 and 1.5 ng ml?1, respectively. The relative standard deviations for five replicate determinations were ca. 3% for both elements. The calibration graphs were linear up to 100 μg ml?1 vanadium(V) and 10 μg ml?1 titanium(IV). Results of analyses of some low-alloy steel samples are given.  相似文献   

12.
In this work, tungsten coil (W-Coil) devices are used as atomizers for electrothermal atomization atomic absorption spectrometry (ETAAS), electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS), and electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES). For most cases in ETAAS and ETA-LEAFS, limits of detection (LODs) using the W-Coil are within a factor of ten of those observed with commercial graphite furnace systems. LOD for Cd by W-Coil AAS is 10 pg, while LODs for As, Se, Cr, Sb and Pb by W-Coil LEAFS are 950, 320, 1400, 330, and 160 fg, respectively. The compact W-Coil device makes it an ideal atomizer for portable atomic spectrometry instrumentation, especially when coupled with a miniature charge coupled device spectrometer. Alternatively, the atomizer can be used as an inexpensive, modular add-on to an existing commercial ICP-AES system; and the thermal separation of Pb with interference elements Al, Mn, and Fe is demonstrated.  相似文献   

13.
电沉积-钨丝电热原子吸收光谱法测定水样中的铅   总被引:1,自引:0,他引:1  
研制了一种便携式钨丝电热原子吸收光谱分析装置,其主要包括:钨丝电热原子化器、多道微型CCD光谱仪、仪器电源系统以及控制系统。并将电沉积分离富集技术与该钨丝电热原子吸收光谱分析仪器结合,完成环境水样中铅的现场分析。并对铅的电沉积条件作了研究,最佳电沉积电位为负650 mV(vs.SCE),方法检出限:0.20μg/L,线性范围:1~15μg/L,对4μg/L Pb标准溶液10次重复测试,RSD为4.4%。  相似文献   

14.
A method for the determination of bismuth in metallurgical materials using hydride generation coupled with a merging zones flow system and atomic absorption spectrometry using a quartz tube atomizer with tungsten coil is proposed. The parameters related to the bismuthine generation, the flow injection system and the use of a tungsten coil were studied and the optimized system shows a wide calibration range and good stability over time, without losses in sensitivity. The analytical curve is linear from 10 to 750 μg l−1 of Bi with R0.999. A detection limit of 1.9 ng Bi and an analytical frequency of 60 determinations per hour were obtained. Five metallurgical reference materials were analyzed with the proposed method after their acid dissolution. The results obtained were in good agreement with certified or recommended values, and the relative standard deviations were lower than 5%.  相似文献   

15.
Chan MS  Huang SD 《Talanta》2000,51(2):373-380
Methods for the direct determination of copper and cadmium in seawater were described using a graphite furnace atomic absorption spectrometer (GFAAS) equipped with a transversely heated graphite atomizer (THGA) and a longitudinal Zeeman effect background corrector. Ammonium nitrate was used as the chemical modifier to determine copper. The mixture of di-ammonium hydrogen phosphate and ammonium nitrate was used as the chemical modifier to determine cadmium. The matrix interference was removed completely so that a simple calibration curve method could be applied. This work is the first one with the capability of determining cadmium in unpolluted seawater directly with GFAAS using calibration curve based on simple aqueous standards. The accuracy of the methods was confirmed by analysis of three kinds of certified reference saline waters. The detection limits (LODs), with injection of a 20-mul aliquot of seawater sample, were 0.06 mug l(-1) for copper and 0.005 mug l(-1) for cadmium.  相似文献   

16.
A new metallic atomization cell is used for trace metal determinations by tungsten coil atomic absorption spectrometry and tungsten coil atomic emission spectrometry. Different protecting gas mixtures are evaluated to improve atomic emission signals. Ar, N2, CO2 and He are used as solvents, and H2 and C2H2 as solutes. A H2/Ar mixture provided the best results. Parameters such as protecting gas flow rate and atomization current are also optimized. The optimal conditions are used to determine the figures of merit for both methods and the results are compared with values found in the literature. The new cell provides a better control of the radiation reaching the detector and a small, more isothermal environment around the atomizer. A more concentrated atomic cloud and a smaller background signal result in lower limits of detection using both methods. Cu (324.7 nm), Cd (228.8 nm) and Sn (286.3 nm) determined by tungsten coil atomic absorption spectrometry presented limits of detection as low as 0.6, 0.1, and 2.2 μg L−1, respectively. For Cr (425.4 nm), Eu (459.4 nm) and Sr (460.7 nm) determined by tungsten coil atomic emission spectrometry, limits of detection of 4.5, 2.5, and 0.1 μg L−1 were calculated. The method is used to determine Cu, Cd, Cr and Sr in a water standard reference material. Results for Cu, Cd and Cr presented no significant difference from reported values in a 95% confidence level. For Sr, a 113% recovery was obtained.  相似文献   

17.
In this work, a sensitive and simple method for the determination of tellurium was developed by hyphenation of electrically heated quartz tube atomic absorption spectrometry and tellurium hydride trapping on platinum-coated tungsten coil. With a mixture of Ar and H2, tellurium hydride was transported to tungsten coil for trapping at 390 °C and releasing at 1200 °C. A limit of detection (LOD, 3σ) of 0.08 ng mL− 1 was obtained with 1 min trapping (1.5 mL sampling volume), and enhancement factor was 28 compared to conventional hydride generation atomic absorption spectrometry. The LOD was better or at least comparable to literature levels involving on-line trapping and some other sophisticated instrumental method such as graphite furnace atomic absorption spectrometry (GF-AAS) and inductively coupled plasma mass spectrometry (ICP-MS), and it can be further lowered down to 0.03 ng mL− 1 by increasing the trapping time to 4 min. The platinum coating was stable for 300 firings without sensitivity loss. Interference and its alleviation were studied in detail. The proposed method was applied to the determination of tellurium in several geological standard reference materials, and the results were found in good agreement with the certified values.  相似文献   

18.
A continuum-source tungsten coil electrothermal atomic absorption spectrometer has been assembled, evaluated, and employed in four different applications. The instrument consists of a xenon arc lamp light source, a tungsten coil atomizer, a Czerny-Turner high resolution monochromator, and a linear photodiode array detector. This instrument provides simultaneous multi-element analyses across a 4 nm spectral window with a resolution of 0.024 nm. Such a device might be useful in many different types of analyses. To demonstrate this broad appeal, four very different applications have been evaluated. First of all, the temperature of the gas phase was measured during the atomization cycle of the tungsten coil, using tin as a thermometric element. Secondly, a summation approach for two absorption lines for aluminum falling within the same spectral window (305.5-309.5 nm) was evaluated. This approach improves the sensitivity without requiring any additional preconcentration steps. The third application describes a background subtraction technique, as it is applied to the analysis of an oil emulsion sample. Finally, interference effects caused by Na on the atomization of Pb were studied. The simultaneous measurements of Pb and Na suggests that negative interference arises at least partially from competition between Pb and Na atoms for H2 in the gas phase.  相似文献   

19.
Peng Wu  Rui Liu  Xiandeng Hou 《Talanta》2009,77(5):1778-635
Flame furnace atomic absorption spectrometry (FF-AAS) is a newly developed flame atomic absorption spectrometric technique based on arranging a flame furnace onto the top of the flame burner head. In this fundamental investigation, 25 elements were carefully tested by using either thermospray FF-AAS or tungsten coil electrothermal vaporization FF-AAS, of which 15 volatile and semi-volatile elements (Cd, Tl, Ag, Pb, Zn, Hg, Cu, Sb, Bi, Te, In, As, Se, Sn and Au) exhibited better limits of detection compared to those by conventional FAAS; however, non-volatile or refractory elements (Fe, Co, Ni, Cr, Mn, Pd, Pt, Al, Be and V) showed inferior sensitivities by the proposed methods.  相似文献   

20.
涂钨石墨管石墨炉原子吸收光谱法测定人参中锗   总被引:1,自引:0,他引:1  
石墨炉原子吸收法测定锗的问题主要是样品原子化前会形成易挥发的GeO,影响分析灵敏度。有关测锗的报道见文献。本工作应用CCl_4萃取和水反萃取,涂钨石墨管石墨炉原子吸收测定人参中锗,获得满意的结果。  相似文献   