首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Kara D  Fisher A  Hill SJ 《The Analyst》2005,130(11):1518-1523
An on-line flow injection method for the direct determination of trace elements in environmental samples is described. A mini-column packed with 2,6-diacetylpyridine functionalized Amberlite XAD-4 was used to preconcentrate and separate 8 trace metals (Cd, Co, Cu, Mn, Ni, Pb, U and Zn) from water and extracts from solid samples. The metals were eluted with 0.1 M HNO(3) directly to the detection system (either inductively coupled plasma-mass spectrometry (ICP-MS) or flame atomic absorption spectrometry (FAAS)). As well as demonstrating that the resin could be used to preconcentrate ultra-trace analytes from natural waters, it was also shown to work well at a pH of 5.5. Therefore, after treatment of sample digests with sodium fluoride, samples that contain extremely large concentrations of iron may be analysed for trace analytes without the excess iron overloading the capacity of the resin. To this end, the analytes Cd, Co, Cu and Ni were preconcentrated from acid extracts of certified soil/sediment samples and then eluted with nitric acid to be determined on-line. Limits of detection (3sigma) of Cd = 0.33 microg l(-1), Co = 0.094 microg l(-1), Cu = 0.34 microg l(-1), Mn = 0.32 microg l(-1), Ni = 0.30 microg l(-1), Pb = 0.43 microg l(-1), U = 0.067 microg l(-1) and Zn = 0.20 microg l(-1) for the FI-ICP-MS system and Cd = 22 microg l(-1), Co = 60 microg l(-1), Cu = 10 microg l(-1) and Ni = 4.8 microg l(-1) for the FI-FAAS system were obtained. Analysis of certified reference materials showed good agreement with the certified values using the two methods.  相似文献   

2.
Summary The element contents of Cd, Co, Cu, Mn, Hg, Ni, Pb and Zn of three different types of sewage sludge were certified. The preparation, the homogeneity and the stability are reported. The certified contents as well as values for Cr and Se and for the aqua regia soluble contents of Cd, Cr, Co, Cu, Mn, Ni, Pb and Zn are given.
Zertifizierung von Schwermetallspuren (Cd, Co, Cu, Mn, Hg, Ni, Pb und Zn) in drei Klärschlammproben
Zusammenfassung In drei verschiedenen Klärschlammproben wurden die Elementgehalte an Cd, Co, Cu, Mn, Hg, Ni, Pb und Zn zertifiziert. Es wird berichtet über die Herstellung, Homogenität und Stabilität. Die zertifizierten Gehalte sowie der Gehalt von Cr, Se und der Gehalt an königswasserlöslichem Cd, Cr, Co, Cu, Mn, Ni, Pb und Zn werden angegeben.
  相似文献   

3.
Summary The element contents of Cd, Cu, Hg, Ni, Pb and Zn of three types of soil were certified. The preparation, homogeneity and stability are reported. The certified contents as well as values for Co, Cr, Mn and Se and for the aqua regia soluble contents Cd, Cr, Cu, Mn, Ni, Pb and Zn are given.
Zertifizierung von Schwermetallspuren (Cd, Cu, Hg, Ni, Pb und Zn) in drei Bodenproben
Zusammenfassung In drei verschiedenen Bodenproben wurden die Elementgehalte an Cd, Cu, Hg, Ni, Pb und Zn zertifiziert. Es wird berichtet über die Bereitung, Homogenität und Stabilität. Die zertifizierten Gehalte sowie der Gehalt an Cr, Co, Mn und Se und der Gehalt an königswasserlöslichem Cd, Cr, Cu, Mn, Ni, Pb und Zn werden angegeben.
  相似文献   

4.
A flow injection (FI) on-line preconcentration procedure by using a nanometer-sized alumina packed micro-column coupled to inductively coupled plasma mass spectrometry (ICP-MS) was described for simultaneous determination of trace metals (V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb) in the environmental samples. The effects of pH value, sample flow rate, preconcentration time, and interfering ions on the preconcentration of analytes have been investigated. Under the optimized operating conditions, the adsorption capacity of the nanometer-sized alumina for V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb were found to be 11.7, 13.6, 15.7, 9.5, 12.2, 13.3, 17.1, 17.7 and 17.5 mg g−1, respectively. With 60 s preconcentration time and 60 s elution time, an enrichment factor of 5 and the sampling frequency of 15 h−1 were obtained. The proposed method has been applied to the determination of trace metals in environmental certified reference materials and natural water samples with satisfactory results.  相似文献   

5.
An adsorbent calix[4]arene carboxylic acid was employed as the adsorption material for on-line flow injection( FI) micro-column preconcentration coupled with flame atomic absorption spectrometry(FAAS) determination of trace heavy metals(Cu, Pb, Co, Ni and Cd). Parameters such as the pH, loading time and flow rate of sample, and the concentration, volume and flow rate of eluent were optimized. The enrichment factors are 50.0, 56.5, 11.6, 12.1 and 19.1 for Cu, Pb, Co, Ni, and Cd, respectively, and a sample throughput of 20 h-1 was obtained. The limits of detection for Cu, Pb, Co, Ni, and Cd were in a range of 1.56―3.91 μg/L, and the relative standard deviations(RSDs) were less than 2.76%(n=7). Furthermore, the proposed method was successfully applied to the determination of Cu, Pb, Co, Ni, and Cd in certified reference materials and various water samples.  相似文献   

6.
Analysis of heavy metals in atmospheric particulate by ion chromatography   总被引:1,自引:0,他引:1  
Cu, Ni, Zn, Co, Fe+2, Mn, Cd, Fe+3 and Pb are easily separated and detected in isocratic mode by ion chromatography with post-column derivatization using a bifunctional ion-exchange column and an eluent formed by oxalic acid (28 mM) and sodium nitrate (250 mM). The separation is optimised by using a suggested sample solution containing a given concentration of chloride. Detection limits were 10-15 ppb for all the metals except for cadmium and lead, for which detection limits of 30 and 60 ppb were found, respectively. The method was tested on an atmospheric particulate certified sample. The measured values were in good agreement with certified values. Real samples of atmospheric particulate from industrial and urban sites were analysed and the results are discussed.  相似文献   

7.
Prabhakaran D  Subramanian MS 《Talanta》2003,59(6):1227-1236
A new chelating polymeric sorbent was developed by functionalizing Amberlite XAD-16 with 1,3-dimethyl-3-aminopropan-1-ol via a simple condensation mechanism. The newly developed chelating matrix offered a high resin capacity and faster sorption kinetics for the metal ions such as Mn(II), Pb(II), Ni(II), Co(II), Cu(II), Cd(II) and Zn(II). Various physio-chemical parameters like pH-effect, kinetics, eluant volume and flow rate, sample breakthrough volume, matrix interference effect on the metal ion sorption have been studied. The optimum pH range for the sorption of the above mentioned metal ions were 6.0–7.5, 6.0–7.0, 8.0–8.5, 7.0–7.5, 6.5–7.5, 7.5–8.5 and 6.5–7.0, respectively. The resin capacities for Mn(II), Pb(II), Ni(II), Co(II), Cu(II), Cd(II) and Zn(II) were found to be 0.62, 0.23, 0.55, 0.27, 0.46, 0.21 and 0.25 mmol g−1 of the resin, respectively. The lower limit of detection was 10 ng ml−1 for Cd(II), 40 ng ml−1 for Mn(II) and Zn(II), 32 ng ml−1 for Ni(II), 25 ng ml−1 for Cu(II) and Co(II) and 20 ng ml−1 for Pb(II). A high preconcentration value of 300 in the case of Mn(II), Co(II), Ni(II), Cu(II),Cd(II) and a value of 500 and 250 for Pb(II) and Zn(II), respectively, were achieved. A recovery of >98% was obtained for all the metal ions with 4 M HCl as eluting agent except in the case of Cu(II) where in 6 M HCl was necessary. The chelating polymer showed low sorption behavior to alkali and alkaline earth metals and also to various inorganic anionic species present in saline matrix. The method was applied for metal ion determination from water samples like seawater, well water and tap water and also from green leafy vegetable, from certified multivitamin tablets and steel samples.  相似文献   

8.
Summary The element contents of As, Cd, Co, Cu, Fe, Mn, Hg, Na, Pb und Zn of a fly ash from pulverised coal are certified. The procedures and their results for the homogenisation, the contamination and homogeneity checks and the analytical campaign are reported. The certified mass fractions and indicative values for Cr, Ni, Th, V and water soluble sulphate are given. The work was carried out within the framework of the activities of the Community Bureau of Reference (BCR) of the Commission of the European Communities.
Zertifizierung von Spurengehalten (As, Cd, Co, Cu, Fe, Mn, Hg, Na, Pb und Zn) in einer Flugasche aus Pulverkohle
Zusammenfassung In einer Flugasche aus Pulverkohle wurden die Elementgehalte an As, Cd, Co, Cu, Fe, Mn, Hg, Na, Pb und Zn zertifiziert. Über die Homogenisierung, die Kontrolle der Kontaminierung und Homogenität und die analytischen Ringversuche wird berichtet. Die zertifizierten Gehalte sowie der Gehalt von Cr, Ni, Th, V und wasserlöslichem Sulfat werden gegeben. Die Arbeit wurde ausgeführt im Rahmen des Programms des Referenzbüros der Kommission der Europäischen Gemeinschaften (BCR).
  相似文献   

9.
A rapid method for the determination of Pb, Cd, Cu, Cr, Co, Ni, Mn and Zn in honey and sugars without prior digestion or ashing of the sample was developed, using inductively coupled plasma atomic emission spectrometry (ICP-AES). The critical instrumental parameters such as sample flow rate and radio frequency incident power were thoroughly optimized. The effect of matrix type and its concentration was also examined for glucose/fructose, sucrose and honey matrices. The sensitivity was investigated using calibration curves obtained in presence of the above matrices. The obtained recoveries for Cd, Cu, Cr, Co, Ni and Mn at the μg l−1 level were satisfactory and practically independent of the matrix used for the calibration standards. The recoveries of Pb and Zn were less sufficient. Various commercial samples of honey, sugar, glucose and fructose were analyzed with respect to their toxic metal content. The method can be applied for routine analysis, quality and environmental pollution control purposes at the μg l−1 level of concentration, after suitable dilution of the samples.  相似文献   

10.
Neutron activation analysis methods for the determination of impurities in zirconium cladding material and uranium oxide are described. Detection limits for the elements Al, Cd, Cr, Co, Cu, Hf, Fe, Mn, Ni, W and U in zirconium are below that required by the ASTM B 352-79 standard. The method has been tested on the NIST SRM 360a Zircaloy-2 from which the elements Na, Mg, Al, Ca, V, Cr, Fe, Co, Ni, Cu, Eu and U have been detected. The values for Cr, Fe, Ni and Cu are compared with the certified values. A method for the pre-irradiation separation of the elements Mg, Na, Al, K, Sc, Ca, V, Mn, Cr, Fe, Co, Cu, Zn, Rb, Zr, Cd, Cs, REE and Hf from uranium has been developed. A neutron activation analysis method for the determination of those elements in uranium is described. The method is tested by the analysis of the IAEA reference sample SR-54/64. The elements Al, Mn, V, Cu, Cr, Co, Ni and Fe have been detected and the results compared with the certified values.  相似文献   

11.
Four algae reference materials, IAEA-391, 392, 393 and IAEA-140, prepared by the International Atomic Energy Agency for intercomparison under different preparation conditions were analyzed for 24 elements. Conventional neutron activation analysis (NAA) was used to determine Al, Ca, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Sb, V and Zn and epithermal NAA using BN and Cd as shielding material for I, Br, As, Ni, Mo and Cd. Inductively coupled plasma mass spectrometry (ICP-MS) as a complementary and comparative method was applied to determine Pb, Sn, Ni, Sr, Rb, As, Co, Cr, Cu, Mn, V, Mo and Zn. Two analytical quality control standard reference materials IAEA-V-10 (hay powder) and IAEA-331 (spinach) were analyzed simultaneously with real samples. The results agree quite well with each other and with the certified values.  相似文献   

12.
Cheng F  Xianbao W  Wuming Z  Xingyao Z 《Talanta》1999,50(2):253-259
A chromatographic method for the determination of transition metals in human hair samples is described. The method involves the separation of Cu, Pb, Zn, Ni, Co, Cd and Mn in a C18 column coated with sodium hexadecane-sulfonate (SHS) and spectrophotometric detection (520 nm) after post-column reaction of the eluted metals with 4-(2-pyridylazo)-resorcinol (PAR). The eluent was a 100 mM tartrate solution adjusted to pH 3.1 with a 2 M sodium hydroxide solution (flow-rate=1.0 ml min(-1)). A good separation of the eluted metals (specially for Cu/Pb and Zn/Ni) has been achieved. The detection limits, expressed as mug l(-1), were 2.2 (Cu), 8.0 (Pb), 2.8 (Zn), 1.5 (Ni), 1.5 (Co), 12.0 (Cd), and 1.4 (Mn). A microwave-assisted closed vessel acid digestion procedure with HNO(3)+HClO(4) (4+1 ml) was used for the hair samples solubilisation. Nineteen hair samples were analysed with the proposed method. The results were in good agreement with those obtained by atomic absorption spectrometry (AAS).  相似文献   

13.
A silica-based inorganic sorbent was synthesized by the thermal decomposition of ammonium heptamolybdate on silica and applied for the preconcentration and simultaneous determination of Cd, Co, Cr, Cu, Fe, Mn, Ni, and Pb in river water samples using a column system with flame atomic absorption spectrometry. Attenuated total reflection-Fourier transformation infrared spectroscopy, scanning electron microscopy, and electron dispersive spectroscopy were used for sorbent characterization. The effects of pH, sample volume, eluent type, eluent concentration, eluent volume, sample flow rate, and matrix ions (Al, Bi, Ca, Mg, and Zn) on the recovery of the metals in model solutions were investigated. The adsorption capacities (µmol g?1) of SiO2-MoO3 were 88.96 (Cd), 169.69 (Co), 153.85 (Cr), 188.88 (Cu), 179.05 (Fe), 163.81 (Mn), 136.31 (Ni), and 38.61 (Pb). The detection limits of the method were 9.09, 10.82, 10.77, 49.57, 31.64, 6.40, 8.86, 19.15?µg L?1 for Cd, Co, Cr, Cu, Fe, Mn, Ni, and Pb, respectively, with a preconcentration factor of 25. The developed method was used for the determination of the target metals in real samples and the recoveries for spiked samples were found to be from 91.2% to 102.9%.  相似文献   

14.
CCD-ICP-AES内标法同时测定化肥中12种有害元素   总被引:1,自引:0,他引:1  
研究了采用CCD-ICP-AES同时测定化肥中As、Cd、Co、Cr、Cu、Hg、Mo、Ni、Pb、Sb、Se和Zn等12种有害元素的方法.采用微波消解法处理样品,加入Y作为内标,消除了化肥基体对测定结果的干扰效应.方法对化肥中各元素的测定回收率在81.6%~120%之间,测定精密度在0.7%~13.8%之间.用该法测定了两种国家标准物质.  相似文献   

15.
A new chelating resin, poly(diacetonitrile methacrylamide-co-divinylbenzene-co-vinylimidazole), was synthesized and characterized by infrared spectroscopy, scanning electron microscopy, thermogravimetric analysis, and elemental analysis. The novel resin was used for the first time as a chelating adsorbent for the preconcentration of Cd, Co, Cr, Cu, Mn, Ni, Pb, and Zn from various samples by flame atomic absorption spectrometry. The adsorption capacities of the resin were 29.3, 31.6, 29.3, 27.3, 35.5, 31.7, 39.8, and 32.3?mg?g?1 for Cd, Co, Cr, Cu, Mn, Ni, Pb, and Zn, respectively. The detection limits of the metal ions were from 0.42 to 3.21?µg?L?1. A preconcentration factor of 30 for all metal ions was obtained. The precision of the method as the relative standard deviation was less than or equal to 2.6%. The described method was validated with certified reference materials and fortified real samples. The method was used for the determination of the analytes in well water and wastewater.  相似文献   

16.
Analytical results are reported for the determination of inorganic species in water and sediments sampled in the Senio river ecosystem. The species determined are Cu, Pb, Cd, Zn, Co, Cr, Ni, Fe, Mn, Hg, F-, Cl-, Br, NO3-, SO4-, Na+, K+, Ca++, Mg++, NH4+ in integrated water, and Cu, Pb, Cd, Zn, Co, Cr, Ni, Fe, Mn, Hg in sediments. For all the elements, in addition to detection limits, precision and accuracy are given: the former, expressed as relative standard deviation (sr), and the latter, expressed as relative error (e), were good, being in all cases lower than 6%. Limitedly to Cu, Pb, Cd and Zn a critical comparison with voltammetric measurements is also discussed.  相似文献   

17.
Summary The analytical performance of an on-line oxine-cellulose microcolumn preconcentration system coupled to simultaneous ICP was investigated. Different factors including the pH of the sample solution, the flow rates of sample loading and eluation, the acidity of eluent and different eluents were investigated and optimized. In comparison with continuous aspiration, the signal enhancement factors of eleven elements (Zn, Cu, Ni, V, Cr, Fe, Mn, Co, Pb, Cd and Al) were in the range of 6.4 to 13.5 for peak height (0.5 s) and 3.7 to 5.8 for peak area (15 s), respectively. The influences of matrix ions, such as Ca, Mg, Fe, Cu and NaCl were studied. Performance was demonstrated by simultaneous determination of seven (Zn, Cu, Ni, V, Cr, Fe, Mn) elements in a number of CRMs. Most results were satisfactory, except for iron and chromium. The possible reasons were discussed. Co, Pb, Cd and Al were not available in the simultaneous instrument. Therefore, only the analytical performance was measured for these elements by the sequential instrument.On leave from Shanghai Institute of Metallurgy, Academia Sinica, Shanghai, China 200050  相似文献   

18.
This paper describes a simple procedure for the direct analysis and determination of multiple elements in dried blood samples on a filter membrane using laser ablation coupled with inductively coupled plasma mass spectrometry (LA-ICP-MS). With this technique, we simultaneously quantified 13 elements in whole blood: Be, Mn, Co, Ni, Tl, Bi, Sb, Pb, Cu, Zn, Ba, Mg, and Cd. The measured accuracies was in agreement with the Seronorm CRM certified values, except for Mn, Zn, Ba and Cd, which presented absolute differences higher than the expanded uncertainty for these elements. The within-run precision was less than 5.7% (relative standard deviation, RSD), except for the analyses of Be, and Mn (8.6% and 11.1%, respectively). The reproducibility (between-run precision) was calculated in terms of the RSD obtained for 12 analyses (i.e., four replicates of each sample in three analytical runs). Apart from Be, Mn, and Zn, the reproducibilities of all the elements listed above ranged between 4.0% and 8.5%. In contrast, for Cd, the concentration obtained was significantly different from the certified value; analyses of this element exhibited low reproducibility. Applying the matrix-matched calibration method, the accuracy for Cd measured was in agreement with both SRM966 and BCR 635; thus, matrix-matched calibration is a practical means of overcoming matrix-enhancement effects for the quantification of Cd. Sample throughput (ca. 5 min per sample) made it possible to rapidly screen a larger number of samples relative to other techniques that require time-consuming sample preparation steps (e.g., removal of a portion of the solid sample or digestion).  相似文献   

19.
Tropolone-5-sulfonic acid was used to separate and collect trace elements as their complexes onto an anion-exchange resin in photon-activation of biological materials. Retention behaviour of the anionic complexes of Cr, Mn, Fe, Co, Ni, Cu, Zn, and Pb on Dowex 1-X8 resin was examined with respect to pH, amount of resin, concentration of the ligand, and coexisting salt anions, using radioisotope tracers. Under optimum conditions, Cr, Mn, Co, Ni, Zn and Pb were collected from the irradiated samples of NBS-SRM Orchard Leaves, NBS-SRM Spinach, green tea and black tea on the marcket. The analytical results agreed with certified values and the reproducibility was good.  相似文献   

20.
We present a new multielement masking method using magnesium hydroxide coprecipitation for the selective determination of Pb by differential pulse anodic stripping voltammetry (DPASV). The recovery of Pb in the masking method was over 95%, while interfering ions (Cd(2+), Co(2+), Cu(2+), Fe(3+), Mn(2+), and Ni(2+)) could be removed at 100% from the analytical sample. A linear regression was obtained in the Pb concentration from 10 to 1000 microg kg(-1) in the existence of 100 microg kg(-1) of the interfering ions. When this method was applied to the determination of Pb in a natural water-standard reference material (NIST 1640), the determined value for Pb in this work (25.4 +/- 4.1 microg kg(-1)) almost agreed with the certified value (27.89 +/- 0.14 microg kg(-1)).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号