1.
The aim of our investigation was to carry out quantitative isolation of Cu-thionein (Cu-Th) in human body fluids (urine, plasma and breast milk) in order to determine the level of exposure to heavy metals. In the experiment covalent affinity chromatography with thiol-disulphide interchange gel (CAC-TDI) was used as a solid phase extraction (SPE) support for preconcentration of Cu-thionein (Cu-Th) protein and Cu bonded with MT from water and human fluids samples. The present paper is a continuation of early experiments on the quantitation of Hg-thionein (Hg-Th), Cd-thionein (Cd-Th) and Zn-thionein (Zn-Th) in human body fluids such as urine, plasma and breast milk.  相似文献   

2.
Solvent extraction as a technique for the separation of ionic solutes and the advantages and application of substoichiometric extraction in neutron activation analysis have been discussed. The application of this technique has been elucidated with reference to the determination of Zn, Cd and Hg in environmental samples. The decontamination factor, accuracy, precision, sensitivity and radiochemical purity of the separated fraction have been discussed.  相似文献   

3.
This work reports a study of the chromatographic behaviour of seven carbamate pesticides (aldicarb, carbetamide, propoxur, carbofuran, carbaryl, methiocarb, and pirimicarb) by gas chromatography-mass spectrometry (GC-MS). Variables such as injector temperature, solvent, injection mode, and the degree of ageing of the chromatographic column were studied. One of the aims of this work was to achieve a controlled decomposition of carbamates by a solid-phase microextraction (SPME) preconcentration step with a polyacrylate fibre in order to obtain reproducible chromatographic signals of the degradation products. Optimisation of the SPME process was accomplished by means of experimental design. Several methods using ultrapure water were developed with different preconcentration configurations: SPME-GC-MS, SPE followed by SPME-GC-MS, and SPE plus GC-MS. For all the pesticides studied, method detection limit (MDL) values below 0.1 microg L-1 were reached in at least one of the proposed configurations.  相似文献   

4.
Multiwalled carbon nanotubes (MWCNTs) were used as a novel kind of solid-phase extraction adsorbents in this work as well as an analytical method based on MWCNTs solid-phase extraction (SPE) combined with high-performance liquid chromatography (HPLC) was established for the determination of polycyclic aromatic hydrocarbons (PAHs), some of which belong to typical persistent organic pollutants (POPs) owing to their carcinogenicity and endocrine disrupting activity. Several conditions that probably affected the extraction efficiency including the eluent volume, sample flow rate, sample pH and the sample volume were optimized in detail. The characteristic data of analytical performance were determined to investigate the sensitivity and precision of the method, and the method was applied to the determination of PAHs in environmental water samples such as river water sample, tap water sample and wastewater sample from the constructed wetland effluent. The experimental results indicated that there were excellent linear relationship between peak area and the concentration of PAHs over the range of 0.04-100 microg L(-1), and the precisions (RSD) were 1.7-4.8% under the optimal conditions. The detection limits of proposed method for the studied PAHs were 0.005-0.058 microg L(-1) (S/N=3). The recoveries of PAHs spiked in environmental water samples ranged from 78.7 to 118.1%. It was concluded that MWCNTs packed cartridge coupled with HPLC was an excellent alternative for the routine analysis of PAHs at trace level.  相似文献   

5.
A rapid technique based on dynamic microwave-assisted extraction coupled with on-line solid-phase extraction of high-performance liquid chromatography (DMAE-SPE-HPLC) has been developed. A TM010 microwave resonance cavity built in the laboratory was applied to concentrate the microwave energy. The sample placed in the zone of microwave irradiation was extracted with 95% acetonitrile (ACN) aqueous solution which was driven by a peristaltic pump at a flow rate of 1.0 mL min−1. The extraction can be completed in a recirculating system in 10 min. When a number of extraction cycles were completed, the extract (1 mL) was diluted on-line with water. Then the extract was loaded into an SPE column where the analytes were retained while the unretained matrix components were washed away. Subsequently, the analytes were automatically transferred from the SPE column to the analytical column and determined by UV detector at 238 nm. The technique was used for determination of organochlorine pesticides (OCPs) in grains, including wheat, rice, corn and bean. The limits of detection of OCPs are in the range of 19-37 ng g−1. The recoveries obtained by analyzing the four spiked grain samples are in the range of 86-105%, whereas the relative standard deviation (R.S.D.) values are <8.7% ranging from 1.2 to 8.7%. Our method was demonstrated to be fast, accurate, and precise. In addition, only small quantities of solvent and sample were required.  相似文献   

6.
7.
Fan J  Wu C  Xu H  Wang J  Peng C 《Talanta》2008,74(4):1020-1025
A new material for solid-phase extraction of Pb(II) was prepared using chemically functionalized silica gel with alizarin violet. This material is stable in 6molL(-1) of HCl, 6molL(-1) of H(2)SO(4), common organic solvents and pH 1.0-9.0 aqueous solutions. The influences of analytical parameters including pH of the aqueous solution, amount of the functionalized silica gel, stirring time and flow rates of sample solutions on the quantitative recoveries of Pb(II) were investigated. At the optimum conditions, Pb(II) can be adsorbed with almost 100.0% retention, the adsorption equilibration for Pb(II) was achieved within 15min, and the adsorption capacity of the sorbent for Pb(II) is 3.45mgg(-1) of dry functionalized silica gel. For Pb(II) solution of 10ngmL(-1), the pre-concentration factor is as high as 500, and the recovery is higher than 92%. The new solid-phase extractant has been used for the pre-concentration of low level of Pb(II) in water and soil samples with high recoveries. The standard reference water sample (GSBZ 50009-88(2)) was introduced for accuracy and precision of analytical data.  相似文献   

8.
Herein, a hyphenated system combining a high-throughput solid-phase extraction (htSPE) microchip with inductively coupled plasma-mass spectrometry (ICP-MS) for rapid determination of trace heavy metals was developed. Rather than performing multiple analyses in parallel for the enhancement of analytical throughput, we improved the processing speed for individual samples by increasing the operation flow rate during SPE procedures. To this end, an innovative device combining a micromixer and a multi-channeled extraction unit was designed. Furthermore, a programmable valve manifold was used to interface the developed microchip and ICP-MS instrumentation in order to fully automate the system, leading to a dramatic reduction in operation time and human error. Under the optimized operation conditions for the established system, detection limits of 1.64–42.54 ng L−1 for the analyte ions were achieved. Validation procedures demonstrated that the developed method could be satisfactorily applied to the determination of trace heavy metals in natural water. Each analysis could be readily accomplished within just 186 s using the established system. This represents, to the best of our knowledge, an unprecedented speed for the analysis of trace heavy metal ions.  相似文献   

9.
Chaozhang Huang 《Talanta》2007,73(2):274-281
Mesoporous titanium dioxide as a novel solid-phase extraction material for flow injection micro-column preconcentration on-line coupled with ICP-OES determination of trace metals (Co, Cd, Cr, Cu, Mn, Ni, V, Ce, Dy, Eu, La and Yb) in environmental samples was described. Possessing a high adsorption capacity towards the metal ions, mesoporous titanium dioxide has found to be of great potential as an adsorbent for the preconcentration of trace metal ions in samples with complicated matrix. The experimental parameters including pH, sample flow rate, volume, elution and interfering ions on the recovery of the target analytes were investigated, and the optimal experimental conditions were established. Under the optimized operating conditions, a preconcentration time of 90 s and elution time of 18 s with enrichment factor of 10 and sampling frequency of 20 h−1 were obtained. The detection limits of this method for the target elements were between 0.03 and 0.36 μg L−1, and the relative standard deviations (R.S.D.s) were found to be less than 6.0% (n =7, c =5 ng mL−1). The proposed method was validated using a certified reference material, and has been successfully applied for the determination of the afore mentioned trace metals in natural water samples and coal fly ash with satisfactory results.  相似文献   

10.
A sensitive, economical, and miniaturized self-assembly pipette tip graphene solid-phase extraction (PT-G-SPE) coupled with liquid chromatography fluorescence detection (LC-FD) was developed for rapid extraction and determination of three sulfonamide antibiotics (SAs) in environmental water samples. The PT-G-SPE cartridge, assembled by packing 1.0 mg of graphene as sorbent into a 100 μL pipette tip, showed high adsorption capacity for the SAs owing to the large surface area and unique structure of graphene. The factors that affected the extraction efficiency of PT-G-SPE, including sample volume, pH, sorbent amount, washing solvent and eluent solvent were optimized. Good linearity for SAs was obtained in a range of 2–4000 pg mL−1 with correlation coefficients (r2) ≥ 0.9993. The recoveries of the SAs at three spiked levels ranged from 90.4% to 108.2% with relative standard deviations (RSD) ≤ 6.3%. In comparison with other sorbents such as C18, HLB, SCX, PCX, and multiwalled carbon nanotubes, one advantage of using graphene as sorbent of pipette tip solid-phase extraction (PT-SPE) was that PT-G-SPE could adsorb larger sample volume (10 mL) at a small amount of sorbent (1 mg) and low solvent consumption with good extraction efficiency, which not only increased the fraction of analytes to LC and the sensitivity of SAs determination, but also reduced the cost and pollution.  相似文献   

11.
Atomic spectroscopy is the most popular approach to determine the presence of heavy metals in the environment. Heavy metals are potentially toxic and have various negative effects on many living organisms, including humans. With the rapid increase in the variety of industries and human activities, large amounts of heavy metals are released into the atmosphere, water, and soil. Heavy metal analysis of environmental samples is very important for determining the exposure limits. Environmental samples are highly complex matrices, and various sample preparation techniques have been developed for the extraction of heavy metals from them, including magnetic solid-phase extraction (MSPE). The use of MSPE in heavy metal analysis has recently gained significant attention owing to a number of advantages. MSPE technique overcomes main issues such as phase separation, handling, and column packing. The use of magnetic adsorbents in sample preparation has grown over the past few years, making MSPE a promising technique for sample preparation. The objective of this review article is to provide the latest applications of MSPE coupled with atomic spectroscopy for heavy metal determination in environmental samples. In addition, new magnetic adsorbents and their analytical merits are emphasized.  相似文献   

12.
A simple, rapid, and reliable online methodology for the determination of benzidine and 3,3'-dichlorobenzidine (3,3'-DCB) in natural waters is proposed. The analytes are extracted and preconcentrated from aqueous samples in a small stainless steel precolumn packed with a polymeric PLRP-S phase. The precolumn is further online-analyzed by reversed-phase gradient-elution chromatography with a highly sensitive and selective coulometric detection at E = 700 mV. Recoveries greater than 90% and a relative standard deviation of approximately 5% are achieved with samples spiked at low micrograms-per-liter concentration levels. The detection limits of the method in fortified reagent water samples are 100 ng/L for benzidine and 50 ng/L for 3,3'-DCB.  相似文献   

13.
Ethosuximide (ETX) is a common antiepileptic drug in the first line of absence epilepsy. In this study, for the first time, an economical and efficient electro-membrane (EME) method for determination of ETX in a complex biological matrix using HPLC-UV has been developed. Factors affecting conventional EME were evaluated. 1-Octanol was immobilized in a polypropylene membrane and a voltage of 35 V was applied between two platinum electrodes for 15 min. The pH of acceptor and donor phases for ionization of ETX was adjusted to 13 and 11, respectively. Under optimal microextraction conditions, the enrichment factor was 21.02 and the linear range of ETX was 0.25 to 8.00 μg/mL with an acceptable R2 ≥ 0.9986. Inter-day and intra-day precision and accuracy of the suggested method were calculated with RSD < 9.5% and relative error <7.0%, respectively. The mean relative recovery of ETX in the human saliva and plasma samples was 81.68% and 74.47, respectively; while limit of detection and quantification concentrations were 0.08 and 0.25 μg/mL, respectively. Furthermore, to evaluate the application of the method, plasma and saliva samples of volunteers administering a single dose of ETX were analyzed successfully by EME-HPLC-UV method.  相似文献   

14.
The copper(II) isonicotinate (Cu(4-C5H4N-COO)2(H2O)4) coordination polymer was prepared, characterized and explored as sorbent for flow injection solid-phase extraction on-line coupled with high-performance liquid chromatography (HPLC) for determination of trace polycyclic aromatic hydrocarbons (PAHs) in environmental matrices. Naphthalene, phenanthrene, anthracene, fluoranthene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene and benzo(ghi)perylene with various shape, size and hydrophobicity were used as model analytes. The porosity of the coordination polymer allows these guest PAHs molecules to diffuse into the buck structure, and the shape and size of the pores lead to shape- and size-selectivity over the guests. The precolumn packed with the coordination polymer was shown to be promising for solid-phase extraction of PAHs in environmental samples with subsequent HPLC separation and UV detection. With extraction of 50 ml of sample solution, the enhancement factors for the PAHs studied ranged from 200 to 2337, depending on the shape, size and hydrophobic property of the PAHs. The detection limits (S/N = 3) of 2-14 ng l(-1) and the sample throughput of 3 samples h(-1) were obtained. The developed method was applied to the determination of trace PAHs in a certified reference material (coal fly ash) and local water samples.  相似文献   

15.
In this work, a novel method is described for the determination of bromhexine in biological fluids using molecularly imprinted solid-phase extraction as the sample cleanup technique combined with high performance liquid chromatography (HPLC). The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, chloroform as porogen and bromhexine as the template molecule. The novel imprinted polymer was used as a solid-phase extraction sorbent for the extraction of bromhexine from human serum and urine. Various parameters affecting the extraction efficiency of the polymer have been evaluated. The optimal conditions for molecularly imprinted solid-phase extraction (MISPE) consisted of conditioning 1 mL methanol and 1 mL of deionized water at neutral pH, loading of 5 mL of the water sample (25 μg L−1) at pH 6.0, washing using 2 mL acetonitrile/acetone (1/4, v/v) and elution with 3× 1 mL methanol/acetic acid (10/1, v/v). The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of bromhexine. Results from the HPLC analyses showed that the calibration curve of bromhexine using MIP from human serum and urine is linear in the ranges of 0.5-100 and 1.5-100 μg L−1 with good precisions (3.3% and 2.8% for 5.0 μg L−1), respectively. The recoveries for serum and urine samples were higher than 92%.  相似文献   

16.
This paper describes a novel method for sensitive determination of thiamethoxam, imidacloprid and acetamiprid based on solid-phase extraction with multiwalled carbon nanotubes as the packed materials. Factors that maybe influence the enrichment efficiency, such as sample flow rate, sample pH, and sample volume, were investigated in detail. Under the optimized conditions, the detection limits of thiamethoxam, imidacloprid and acetamiprid were 6.1, 5.4 and 6.7 ng L−1, respectively. The experimental results indicated that there was good linearity (R 2>0.9993) over the range of 0.08~100 ng mL−1 and good reproducibility with the relative standard deviations over the range of 0.7~1.1% (n=6). The proposed method has been applied to the analysis of real-world water samples, and satisfactory achievements were obtained. The average spiked recoveries were in the range of 87.5~109.8%. All the results indicated that the proposed method could be used for the simultaneous determination of the three pesticides in environmental water samples at trace levels.  相似文献   

17.
Solid-phase extraction (SPE) along with reversed-phase liquid chromatography (RP-LC) was used for the simultaneous determination of Zr(IV) and Hf(IV) by means of their ternary chelates with fluoride and 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP). The conditions of SPE sorption were examined in detail: type of SPE column, volume of the sample, volume of the eluent, concentrations of metal ions, fluoride salt, chromogenic reagent, organic phase, and pH. It was established that the sorption of Zr(IV) and Hf(IV), as their ternary chelates, on SPE Zorbax SPE C18 (EC) cartridge was the most efficient, when the sample containing metal ion (Zr(IV), Hf(IV), both, up to 2 μg), 5-Br-PADAP 1.5×10−4, NaF 7.5×10−5 mol l−1, methanol 40%, pH 4.5±1 was applied for the SPE sorption. The chelates were discarded from SPE cartridge using acetonitrile/water (99.75+0.25, v/v) eluent containing 3.8×10−4 mol l−1 sodium fluoride and subsequently separated by RP-LC method. The RP-LC separation of both chelates was optimized and Zorbax SB-C18 analytical LC column along with acetonitrile/water (65+35, v/v) eluent containing the 1.5×10−4 mol l−1 sodium fluoride was used. The established SPE/LC conditions allow Zr(IV) 0.08-2.0 μg and Hf(IV) 0.04-2.0 μg determination in a sample volume up to 150 ml. The detection limits, 0.03 μg Hf(IV) and 0.05 μg Zr(IV), were obtained. Recoveries, (94±2)% for Hf(IV) chelate and (106±2)% for Zr(IV) chelate were obtained, when 1 μg of Zr(IV) and Hf(IV) ions were determined by the present SPE/LC method from the sample volume of 100 ml. The established, pre-concentration SPE conditions, along with the LC separation and determination allow the assay of Zr(IV) and Hf(IV) in complicated matrix materials. The present SPE/LC method was applied to the determination of Zr(IV) and Hf(IV) in tap water and reference geological material (rock, NCS DC 73303; certified content: Zr, 27.7×10−3% (w/w) and Hf, 6.5×10−4% (w/w)).  相似文献   

18.
A carboxylated graphene oxide/polyvinyl chloride (CGO/PVC) material was prepared as a sorbent for the selective extraction of sulphonamides from complex sample. After being dispersed in buffer solution, sample was transferred into the prefabricated solid-phase extraction (SPE) column, which integrated extraction and cleanup into one single-step. A multi-response optimization based on the Box-Behnken design was used to optimize factors affecting extraction efficiency. Compared with the commonly commercial sorbents including MCX, WCX and C18, CGO/PVC hybrid material had higher extraction selectivity and capacity to sulphonamides. The limits of detection and quantification for seven target compounds were in the range of 3.4–7.1 μg/L and 11.4–23.7 μg/L, respectively. The self-assembly SPE cartridge was successfully used to enrich seven analytes in anti-acne cosmetics prior to ion chromatography detection with good recoveries of 87.8–102.0% and relative standard deviations of 1.2–6.4%, implying that this method was suitable for routine analysis of cosmetics.  相似文献   

19.
Mixed hemimicelles solid-phase extraction (SPE) based on cetyltrimethylammonium bromide (CTAB)-coated nano-magnets Fe3O4 was investigated for the preconcentration of four chlorophenols (CPs) in environmental water samples prior to HPLC-spectrophotometry determination in this paper. By the rapid isolating (about 5 min) of Fe3O4 nanoparticles (NPs) through placing a Nd-Fe-B strong magnet on the bottom of beaker, the time-consuming preconcentration process of loading large volume sample in conversional SPE method with a column can be avoided. The unique properties of Fe3O4 NPs such as high surface area and strong magnetism were utilized adequately in the SPE process. This novel separation method produced a high preconcentration rate and factor. A comprehensive study of the adsorption conditions such as the Fe3O4 NPs zeta-potential, CTAB added amounts, pH value, standing time and maximal extraction volume was also presented. Under optimized conditions, four analytes of 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (TCP) and pentachlorophenol (PCP) were quantitatively extracted. The method was then used to determine four CPs in five real environmental water samples. High concentration factors (700) were achieved for each of the analytes, with observed detection limits ranging between 0.11 and 0.15 microg L(-1). The accuracy of method was evaluated by recovery measurements on spiked samples. Good recovery results (83-98%) with satisfactory relative standard deviation (RSD) were achieved. It is important to note that satisfactory preconcentration factors and extraction recoveries for the four CPs were obtained with only a little amount of Fe3O4 NPs (0.1g) and CTAB (60 mg). To the best of our knowledge, this was the first time a mixed hemimicelles SPE method based on Fe3O4 NPs magnetic separation had been used for the pretreatment of environmental water samples.  相似文献   

20.
A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N-oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for use in pharmacokinetic studies. ENO is light-sensitive and the use of a fully on-line process increased the reliability of the assay. Plasma samples previously mixed with neostigmine bromide to prevent in vitro degradation, and tacrine as internal standard (IS), were directly injected into the SPE/LC/ESI-MS/MS system. MS software piloted the overall system. MS/MS detection of ENO and the IS was performed in the positive ion ESI mode using multiple reaction monitoring. The linear calibration curve for ENO ranged from 25 pg ml(-1) to 12.5 ng ml(-1). The limit of quantitation was 25 pg ml(-1) with 250 microl of plasma injected. Precision, accuracy and stability tests were within the acceptable range and just one analyst is required to analyze 50 unknown samples a day five days per week, from the preparation of the samples (i.e. thawing and centrifugation) to data processing. A pilot pharmacokinetic study in three healthy volunteers treated with 4.5 mg of ENO (Génésérine3((R))) showed that the method was suitable for pharmacokinetic studies in humans.  相似文献   