首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
Narcise CI  Coo LD  Del Mundo FR 《Talanta》2005,68(2):298-304
A flow injection-column preconcentration-hydride generation atomic absorption spectrophotometric (FI-column-HGAAS) method was developed for determining μg/l levels of As(III) and As(V) in water samples, with simultaneous preconcentration and speciation. The speciation scheme involved determining As(V) at neutral pH and As(III + V) at pH 12, with As(III) obtained by difference. The enrichment factor (EF) increased with increase in sample loading volume from 2.5 to 10 ml, and for preconcentration using the chloride-form anion exchange column, EFs ranged from 5 to 48 for As(V) and 4 to 24 for As(III + V), with corresponding detection limits of 0.03-0.3 and 0.07-0.3 μg/l. Linear concentration range (LCR) also varied with sample loading volume, and for a 5-ml sample was 0.3-5 and 0.2-8 μg/l for As(V) and As(III + V), respectively. Sample throughput, which decreased with increase in sample volume, was 8-17 samples/h. For the hydroxide-form column, the EFS for 2.5-10 ml samples were 3-23 for As(V) and 2-15 for As(III + V), with corresponding detection limits of 0.07-0.4 and 0.1-0.5 μg/l. The LCR for a 5-ml sample was 0.3-10 μg/l for As(V) and 0.2-20 μg/l for As(III + V). Sample throughput was 10-20 samples/h. The developed method has been effectively applied to tap water and mineral water samples, with recoveries ranging from 90 to 102% for 5-ml samples passed through the two columns.  相似文献   

2.
A dual-column protocol for the sequential determination of As(III) and As(V) is described using inductively coupled plasma-atomic emission spectrometry (ICP-AES) with ultrasonic nebulization (USN). This procedure employed a 16-way valve containing two different homemade mini columns for selective preconcentration of As(III) and As(V). One column was filled with Muromac A-1, which selectively preconcentrated As(III) at pH 3 after complexation with ammonium pyrrolidine dithiocarbamate (APDC, 0.05%). The effluent of the first column was then passed through the second column, which was filled with an anion-exchange resin to collect As(V). By using 0.6 M sodium hydroxide, both species were eluted sequentially and measured by ICP-AES. Enrichment factors of 136 (17 for micro column x8 for USN) for As(V) and 160 (20 for micro column x8 for USN) for As(III) were achieved with 4 min preconcentration. With the proposed procedure, the detection limits were calculated to be 0.7 micro g L(-1) for As(V) and 0.8 micro g L(-1) for As(III) based on (3 sigma) blank determination ( N=10). The relative standard deviations for 20 micro g L(-1) of As(V) and As(III) were 5.8% and 6.5%, respectively. The recovery for spiked water samples was in the range of 85-112%.  相似文献   

3.
A highly sensitive and simple method has been developed for the determination of As(III), total As, Sb(III) and total Sb in drinking water samples by continuous hydride generation and atomic fluorescence spectrometry (HGAFS). For As determination, water samples aspirated in a carrier of 2 mol l(-1) HCl were merged with a reducing NaBH(4) 3%(m/v) solution, with sample and NaBH(4) flow rates of 12.5 and 1.5 ml min(-1) respectively. The hydride generated in a 170 cm reaction coil was transported to the detector with an Ar flow of 400 ml min(-1), and a limit of detection between 5 and 20 ng l(-1) was obtained. For Sb determination, 2.5 mol l(-1) HCl and 2%(m/v) NaBH(4) were employed, with respective flow rates of 9.7 and 2 ml min(-1). The hydride generated in a 50 cm reaction coil was transported to the detector with an Ar flow rate of 300 ml min(-1), and a limit of detection between 6 and 14 ng l(-1) was obtained. Determination of the total concentration of these elements was obtained after a previous reduction with KI. Recovery studies of different added concentrations of these species in natural water samples were between 93 and 104% for As(III), 96-103% for As(V), 93-101% for Sb(III) and 90-119% for Sb(V).  相似文献   

4.
Two flow injection inductively coupled plasma atomic emission spectrometric methods for the preconcentration and determination of trace amounts of cadmium in sea-water and waste-water samples are described based on the adsorption of the metal ion on a micro-column placed in the injection valve of the FI manifold and packed with silica gel funtionalised with 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH-gel) and silica gel functionalised with methylthiosalicylate (TS-gel), respectively. Various parameters and chemical variables affecting the preconcentration and determination of this metal by ICP-AES are evaluated. The DPTH-gel preconcentration method has a linear calibration range from 5 to at least 100 ng ml(-1) of cadmium, with a R.S.D. of 1.1% for ten independent analyses of 100 ng ml(-1), a detection limit of 1.1 ng ml(-1) and a throughput of 40 samples per hour using a 60 s preconcentration time. The TS-gel preconcentration method shows a linear range between 10 and 100 ng ml(-1), with a R.S.D. of 2.5% for ten independent analyses of 100 ng ml(-1), a detection limit of 4.3 ng ml(-1) and a sample throughput of 24 samples per hour for a preconcentration time of 120 s. Validation was carried out against a certified reference water sample and by determining the analyte content in spiked synthetic sea-water, sea-water and waste-water.  相似文献   

5.
Gong B  Li X  Wang F  Chang X 《Talanta》2000,52(2):217-223
A novel spherical macroporous epoxy-dicyandiamide chelating resin is synthesized simply and rapidly from epoxy resin and use for the preconcentration and separation of trace Ga(III), In(III), Bi(III), Sn(IV), Pb(II), V(V) and Ti(IV) ions from solution samples. The analyzed ions can be quantitatively concentrated by the resin at flow rate of 3.0 ml min(-1) at pH 3, and can also be desorbed with 10 ml of 4 M HCl+0.2 g thiourea from the resin column with recoveries of 97-100%. The chelating resin is reused for eight times, the recoveries of these ions are still over 92%, and a 100-1000 times of excess of Fe(III), Al(III),Ca(II), Mg(III), Ni(II), Mn(II), Co(II), Cu(II), Zn(II), and Cd(II) cause no interference in the determination of these ions by inductively-coupled plasma atomic emission spectrometry. The capacities of the resin for the analytes are in the range of 0.66-4.20 mmol g(-1). The results show the relative standard deviation for the determination of 50.0 ng ml(-1) Ga(III), In(III), Bi(III), Sn(IV) and Pb(II), 5.0 ng ml(-1) V(V) and Ti(IV) are in the range of 1.2-4.0%. The recoveries of a standard added in real solution samples are between 96 and 100%, and the concentration of each ion in mineral sample detected by the method is in good agreement with the certified value.  相似文献   

6.
A simple method for the elements preconcentration on thin-layer paraffin-treated cellulose filters was proposed. It was found that pyrrolydinedithiocarbamates of As(III), Bi, Cd, Co, Cu, Fe(III), Ni, Pb, Se(IV), V(V) and Zn obtained after mixing of sample (3-5 ml min−1) and reagent (0.7-1.0 ml min−1) streams were quantitatively recovered from 100 ml sample. The sample acidity was adjusted to pH 4.8-5.2 for preconcentration of Cd, Co, Cu, Fe(III), Ni, Pb, V(V) and Zn, and to 2 M HCl for preconcentration of As, Bi and Se. The optimum reagent concentration was found to be 0.1%. The elements were determined on the filters by X-ray fluorescence spectrometry. The detection limits achieved were 0.1-4.0 μg of element on the filter. Relative standard deviation (R.S.D.) was not higher than 0.08 while determining 5-50 μg of elements on filter. Accuracy and precision of the technique proposed were evaluated by the analysis of spiked natural samples.  相似文献   

7.
A simple flow injection spectrophotometric method for the determination of nitrite is described. Nitrite injected into the flow system reacts with thiourea in acidic medium and the generated thiocyanate ion reacts with Fe(III) in the reagent solution to produce a highly colored product. The influences of chemical and physical parameters including reagent concentrations, sample volume injected, flow rates of the carrier and reagent solutions, reaction coil length and reaction temperature, were studied and optimum values of these parameters were established. Under the optimum conditions, the calibration curve for nitrite was linear over the concentration range 0.36 - 90 microg ml(-1) without preconcentration and over the range 3.8 - 500 ng ml(-1) with a simple online preconcentration step using an anion exchange column. The corresponding detection limits were 0.36 micro ml(-1) and 3.8 ng ml(-1), respectively. Up to 25 samples can be analyzed per hour, with an average relative standard deviation of < or = 1.2%. Interferences by various foreign ions were studied and the method was applied to the determination of nitrite in water and spiked water samples.  相似文献   

8.
An on-line flow injection-hydride generation/atomic absorption spectrometry method was developed for the preconcentration and selective determination of inorganic arsenic [As(III) and As(V)] and its methylated species. The separation of the arsenic species was performed by an automated pH-selective arsines generation technique, using sodium tetrahydroborate(III) as reductant. Each arsine was cryogenically trapped in a PTFE coil, knotted and sealed inside another wider diameter tube, through which liquid nitrogen was suctioned by negative pressure. Then, based on their different boiling points, the arsine species were selectively liberated by using a heating cycle of microwave radiation, followed by atomic absorption detection. A sample solution aliquot mixed with 1% citric acid was used for the determination of As(III) alone, while a second sample aliquot mixed with 2 mol l(-1) nitric acid was used for the quantitative determination of total inorganic arsenic, monomethylarsonic acid and dimethylarsinic acid. Based on 10 ml sample, the detection limits lie within the range 20-60 ng As l(-1), which are sufficiently low to detect the arsines-forming species in natural waters. These values are negatively affected by the reagents purity and background noise due to flame flickering, but the sensitivity can substantially be improved by increasing sample size or running several consecutive reactions.  相似文献   

9.
A simple procedure was developed for the direct determination of As(III) and As(V) in water samples by flow injection hydride generation atomic absorption spectrometry (FI–HG–AAS), without pre-reduction of As(V). The flow injection system was operated in the merging zones configuration, where sample and NaBH4 are simultaneously injected into two carrier streams, HCl and H2O, respectively. Sample and reagent injected volumes were of 250 μl and flow rate of 3.6 ml min−1 for hydrochloric acid and de-ionised water. The NaBH4 concentration was maintained at 0.1% (w/v), it would be possible to perform arsine selective generation from As(III) and on-line arsine generation with 3.0% (w/v) NaBH4 to obtain total arsenic concentration. As(V) was calculated as the difference between total As and As(III). Both procedures were tolerant to potential interference. So, interference such as Fe(III), Cu(II), Ni(II), Sb(III), Sn(II) and Se(IV) could, at an As(III) level of 0.1 mg l−1, be tolerated at a weight excess of 5000, 5000, 500, 100, 10 and 5 times, respectively. With the proposed procedure, detection limits of 0.3 ng ml−1 for As(III) and 0.5 ng ml−1 for As(V) were achieved. The relative standard deviations were of 2.3% for 0.1 mg l−1 As(III) and 2.0% for 0.1 mg l−1 As(V). A sampling rate of about 120 determinations per hour was achieved, requiring 30 ml of NaBH4 and waste generation in order of 450 ml. The method was shown to be satisfactory for determination of traces arsenic in water samples. The assay of a certified drinking water sample was 81.7±1.7 μg l−1 (certified value 80.0±0.5 μg l−1).  相似文献   

10.
A new po1y(acrylphenylamidrazone phenylhydrazide) chelating fiber is synthesized from polyacrylonitrile fiber and used for preconcentration and separation of trace Ga(III), In(III), Bi(III), V(V) and Ti(IV) from solution (5–50 ng ml−1 Ti(IV) or V(V) and 50–500 ng ml−1 Ga(III), In (III) or Bi(III) in 1000–100 ml of solution can be enriched quantitatively by 0.15 g of fiber at a 4 ml min−1 flow rate in the pH range 5–7 with recoveries >95%). These ions can be desorbed quantitatively with 20 ml of 4 M hydrochloric acid at 2 ml min−1 from the fiber column. When the fiber which had been treated with concentrated hydrochloric acid and washed with distilled water until neutral was reused eight times, the recoveries of the above ions by enrichment were still >95%. Two-hundred-fold to 10 000-fold excesses of Cu(II), Zn(II), Ca(II), Mn(II), Cr(III), Fe(III), Ba(II) and Al(III) caused little interference in the determination of these ions by inductively coupled plasma-atomic emission spectrometers (ICP-AES). The relative standard deviations for enrichment and determination of 50 ng ml−1 Ga, In or Bi and 10 ng ml−1 V or Ti are in the range 1.2–2.7%. The contents of these ions in real solution samples determined by this method were in agreement with the certified values of the samples with average errors <3.7%.  相似文献   

11.
A novel absorbent was prepared by dimercaptosuccinic acid chemically modifying mesoporous titanium dioxide and was employed as the micro-column packing material for simultaneous separation/preconcentration of inorganic arsenic and antimony species. It was found that both trivalent and pentavalent of inorganic As and Sb species could be adsorbed quantitatively on dimercaptosuccinic acid modified TiO2 within a pH range of 4–7, and only As(III) and Sb(III) could be quantitatively retained on the micro-column within a pH range of 10–11 while As(V) and Sb(V) were passed through the micro-column without the retention. Based on this fact, a new method of flow injection on-line micro-column separation/preconcentration coupled to inductively coupled plasma optical emission spectrometry was developed for simultaneous speciation of trace inorganic arsenic and antimony in natural waters. Under the optimized conditions, an enrichment factor of 10 and sampling frequency of 10 h− 1 were obtained with on-line mode. The detection limits of As(III), As(V), Sb(III), and Sb(V) are 0.53, 0.49, 0.77 and 0.71 ng mL− 1 for on-line mode and as low as 0.11, 0.10, 0.15 and 0.13 ng mL− 1 for off-line mode due to its higher enrichment factor (50), respectively. The relative standard deviations of two modes are less than 6.7% (C = 20 ng mL− 1, n = 7). The concentration ratio of lower oxidation states/higher oxidation states changing from 1:10 to 10:1 has no obvious effect on the recoveries of As(III) and Sb(III). In order to validate the developed method, two certified reference materials of GSBZ5004-88 and GBW(E)080545 water sample were analyzed and the determined values are in good agreement with the certified values. The proposed method was successfully applied to the simultaneous speciation of inorganic arsenic and antimony in natural waters.  相似文献   

12.
A rapid and sensitive method has been proposed for the sequential determination of chromium(III) and total chromium in water samples by flame atomic absorption spectrometry combined with a flow injection on-line preconcentration on a double-microcolumn. The chromium(III) and total chromium in samples were retained on a double-microcolumn with a cation exchange resin, respectively, and eluted directly into a nebulizer by 3 mol L(-1) HNO3. The characteristic concentration (gives a derivative absorbance of 0.0044) and the detection limit (3sigma) for chromium were 0.512 microg L(-1) and 0.647 microg L(-1) for a preconcentration time of 1 min, respectively. This is an improvement of 20 and 14-times than those of conventional FI-FAAS. The proposed method allows the determination of chromium in the range of 0-90 microg L(-1) with a relative standard deviation of 3.63% at the 10 microg L(-1) level. The method has been applied for the analysis of chromium in reference water of National Research Center for Certified Reference Materials (GBW08607) and other water samples with satisfactory results.  相似文献   

13.
An ICP-OES method using a new poly-acrylacylisothiourea chelating fiber to preconcentrate and separate trace Ti(IV), V(V) and Bi(III) ions from solution samples is established. The results show that 5–25 ng/ml of Ti or V and 50–250 ng/ml of Bi ions in 200–1000 ml of solution can be enriched quantitatively by 0.05 g of the fiber at pH 3 with recoveries over 97%. These ions can be desorbed quantitatively with 10 ml of 4M HC1O4. 100- to 1000-fold excesses of Fe(III), Al(III), Ca(II), Mg(II), Cu(II), Ni(II) and Mn(II) ions cause little interference. The chelating fiber stored for about 2 years can still be used repeatedly for preconcentration and separation of trace Ti, V and Bi ions from solution with above 95% recovery. The RSDs for enrichment and determination of 5 ng/ml of Ti or V and 50 ng/ml of Bi are in the range 2.5–2.8%. The recoveries of added standard in real waste waters and mineral samples are between 96 and 100%, and the concentration found for each ion in the mineral sample was in good agreement with that measured by ETAAS.  相似文献   

14.
The solid-phase chemiluminescence analysis of gold on the surface of an anion-exchange resin was studied. A method for the fast determination of gold using flow injection was established. The anion-exchange resin was used as an adsorbent of gold ion in the form of AuCl4-. The cation-exchange resin was used for the on-line separation of cations in the matrix. To obtain the best results, the preconcentration and separation conditions, chemiluminescence conditions, interfering ions and their elimination conditions were optimized. The linear range of the calibration curve of AuCl4- is from 0 microg ml(-1) to 5.00 microg ml(-1). The detection limit of AuCl4- is 0.012 microg ml(-1). The method has been used for the determination of gold in geological samples (standard ores). The results are in agreement with certified value of gold standard samples with relative standard deviation from 2.22% to 8.97%. Through the use of flow injection, the preconcentration and separation can be performed automatically.  相似文献   

15.
An analytical method was developed for antimony speciation and antimony(III) preconcentration in water samples. The method is based on the selective retention of Sb(III) by modified Saccharomyces cerevisiae in the presence of Sb(V). Heat, caustic and solvent pretreatments of the biomass were investigated to improve the kinetics and thermodynamics of Sb(III) uptake process at room temperature. Heating for 30 min at 80 degrees C was defined as the optimal treatment. Antimony accumulation by the cells was independent of pH (5-10) and ionic strength (0.01-0.1 mol L(-1)). 140 mg of yeast and 2h of contact were necessary to ensure quantitative sequestration of Sb(III) up to 750 microg L(-1). In these conditions, Sb(V) was not retained. Sb(V) was quantified in sorption supernatant by inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma optical emission spectrometry (ICP-OES). Sb(III) was determined after elution with 40 mmol L(-1) thioglycolic acid at pH 10. A preconcentration factor close to nine was achieved for Sb(III) when 100mL of sample was processed. After preconcentration, the detection limits for Sb(III) and Sb(V) were 2 and 5 ng L(-1), respectively, using ICP-MS, 7 and 0.9 microg L(-1) using ICP-OES. The proposed method was successfully applied to the determination of Sb(III) and Sb(V) in spiked river and mineral water samples. The relative standard deviations (n=3) were in the 2-5% range at the tenth microg L(-1) level and less than 10% at the lowest Sb(III) and Sb(V) tested concentration (0.1 microg L(-1)). Corrected recoveries were in all cases close to 100%.  相似文献   

16.
A precise, accurate automatic preconcentration method for the determination of total arsenic at the ng g(-1) level in wheat flour is proposed. The sensitivity of the method can be increased by a factor of 20 by precipitating As(V) from 10 ml of digested sample using a weakly acid silver solution. The Ag(3)AsO(4) precipitate is dissolved with 0.5 ml of 6 M ammonia and the resulting solution is collected in an autosampler cup of the ETAAS instrument. The limit of detection achieved in the determination of total arsenic using Pd(NO(3))(2) as modifier is 0.3 ng ml(-1). The proposed method avoids spectral interferences from cations as they do not precipitate with silver cation; anions, which are coprecipitated with silver, are tolerated at concentrations up to about 10 000 times that of As(V). The need to determine As at very low levels in wheat samples, where chloride and phosphate can occur at concentrations 50 000 and 300 000 times higher, respectively, that of arsenic, requires additional steps to suppress the interference of both anions.  相似文献   

17.
A new analytical procedure for the speciation of antimony in liver tissues is presented here. For this purpose, a flow injection system has been developed for the treatment of samples and the determination of antimony by hydride generation - atomic absorption spectrometry. The method involves the sequential and the on-line extraction of antimony(III) and antimony(V) from solid lyophilized blood and hamsters liver tissues, with 1.5 mol l(-1) acetic acid and 0.5 mol l(-1) sulfuric acid for Sb(III) and Sb(V), respectively. Reduction of Sb(V) to Sb(III) for stibine generation is effected by the on-line pre-reduction with l-cysteine. The linear ranges were 2.5-20 and 1.0-25 mug l(-1) of Sb(III) and Sb(V), respectively. The detection limits (3sigma) were 1.0 mug l(-1) for Sb(III) and 0.5 mug l(-1) for Sb(V). The relative standard deviation values for fifteen independent measurements were 2.1 and 1.8% for Sb(III) and Sb(V), respectively. The recovery studies performed with samples of cattle liver provided results from 98 to 100% for Sb(III) and from 100 to 103% for Sb(V) for samples spiked with single species. For samples spiked with both Sb(III) and Sb(V), the recovery varied from 97 to 103% for Sb(III) and from 101 to 103% for Sb(V).  相似文献   

18.
A preconcentration and determination methodology for vanadium at trace levels in parenteral solutions was developed. Cloud point extraction was successfully employed for the preconcentration of vanadium prior to inductively coupled plasma atomic optical emission spectrometry (ICP-OES) coupled to a flow injection (FI) system. The vanadium was extracted as vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol [V-(5-Br-PADAP)] complex, at pH 3.7 mediated by micelles of the nonionic surfactant polyoxyethylene (5.0) nonylphenol (PONPE 5.0). The extracted surfactant-rich phase (100 mul) was mixed with 100 mul of ethanol and this final volume injected into ICP-OES for the vanadium determination. Under these conditions, the 50 ml sample solution preconcentration allowed raising an enrichment factor of 250-fold; however, it was possible to obtain a theoretical enrichment factor of 500-fold. The lower limit of detection (LOD) obtained under the optimal conditions was 16 ng l(-1). The precision for 10 replicate determinations at the 2.0 mug l(-1) V level was 2.3% relative standard deviation (RSD), calculated with the peak heights. The calibration graph using the preconcentration system for vanadium was linear with a correlation coefficient of 0.9996 at levels near the detection limits up to at least 50 mug l(-1). The method was successfully applied to the determination of vanadium in parenteral solution samples.  相似文献   

19.
A simple and accurate flow injection analysis system coupled with spectrophotometric detector was developed for preconcentration and determination of europium(III) in aqueous samples. The developed flow system includes a europium preconcentration step in a column packed with Amberlite XAD-4 resin impregnated with nalidixic acid at pH 7.0. The europium complex was desorbed from the resin by 0.1 mol L?1 HCl and mixed with arsenazo-III solution (0.05 % solution in 0.1 mol L?1 HCl) and taken to the flow through cell of spectrophotometer where its absorbance was measured at 661 nm. The optimum preconcentration system, chemical and FIA variables were investigated. The preconcentration factors obtained were 115 and 500, detection limits of 0.43 and 0.1 μg L?1, sample throughputs of 40 and 10 were obtained for preconcentration time of 60 and 300 s respectively. The proposed system showed good precision and accuracy with relative standard deviation of 1.5 %. The method has been applied to the determination of europium(III) in real water samples and certified reference material IAEA-SL-1 (Lake sediment).  相似文献   

20.
The water-soluble polymers poly(ethylenimine), quaternized poly(ethylenimine), and poly-4-vinyl-(N-benzyltrimethyl) ammonium chloride were found to be able to change the kinetics of the reaction of cobalt with nitroso-R-salt and the optical density of the cobalt complex formed. The optimum pH range for the complex formation was a wide range from 1 to 10 and at pH 2 the reaction developed instantly. The calibration graph was linear in the range 0.005-2 mug ml(-1). The effective molar absorptivity coefficient of the complex was equal to (2.8+/-0.08)10(3). A spectrophotometric determination method for cobalt with nitroso-R-salt in the presence of water-soluble polymers (before and after membrane preconcentration) and a colorimetric flow injection method were developed. For the flow injection-based spectrophotometric determination, the calibration graph was linear in the concentration range of 0-4.0 mug ml(-1) cobalt with a regression coefficient of 0.9992. The relative standard deviation (R.S.D.) for the determination of 1.0 mug ml(-1) cobalt was 0.9% (ten replicate injections), and at all concentration measured, the R.S.D. of the data was below 5.0%. The proposed FI procedure was applied to river water samples after membrane preconcentration of cobalt. The limit of detection was 4 ng ml(-1).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号