首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Carsol MA  Volpe G  Mascini M 《Talanta》1997,44(11):2151-2159
Carbon-based screen-printed electrodes are suitable for uric acid detection. Xanthine oxidase (XO) was immobilized either directly on the surface of the electrode or in a reactor with CPG aminopropylsilane in a FIA assembly. Higher reproducibility and lifetime was obtained with the reactor. Optimum conditions were found for the determination of Hypoxanthine (Hx), Inosine (HxR) and Inosine monophosphate (IMP). Calibration curves for IMP, HxR and Hx are linear up to 50 muM with detection limit of 1 muM for 50 mul injection. One assay is completed within 30 s. The reproducibility of 20 muM of Hx was obtained with CV 2%.  相似文献   

2.
A novel flow-injection system is proposed for the rapid measurement of the fish freshness indices K1 and K2: K1=[([HxR+[Hx])×100/([IMP]+[HxR]+[Hx])] and K2=[[Hx]×100/([HxR]+[Hx])], where [IMP], [HxR] and [Hx] are inosine-5′-monophosphate, inosine and hypoxanthine concentrations, respectively. For the estimation of index K1, 5′-nucleotidase immobilized reactor and nucleoside phosphorylase (NP)/xanthine oxidase (XO) coimmobilized reactor were incorporated in series in the flow-injection line made up by a 16-way switching valve with two sample loops. For the estimation of index K2, NP and XO immobilized reactors were also incorporated in the similar flow-line. Two sample portions passed through the flow-line with different residence times so that two peaks were obtained. The first and second peaks obtained in the K1-determining system corresponded to the total of HxR and Hx and the total of Hx, HxR and IMP, respectively. Similarly, the first and second peaks obtained in the K2-determining system corresponded to Hx and the total of Hx and HxR, respectively. Therefore, the indices K1 and K2 can be estimated by
where i1 and i2 present the peak current of the first and second peaks, respectively, and f the ratio of the peak currents of the first and second peaks for a Hx standard solution. A sea bream was selected as a model fish and it was stored at 4 °C after death. A good correlation was found between the index K1 and the storage time over a period of 400 h, with a correlation coefficient of 0.992, but no correlation between the index K2 and the storage time. The measurements could be performed at a rate of 22 samples per hour with satisfactory precision (0.6–1.2% R.S.D.), without calibration for each species, accurate weighing of fish meat and any interferences in fish meat.  相似文献   

3.
《Analytical letters》2012,45(14):2499-2513
Abstract

A dual channel chemiluminescence FIA system for the rapid measurement of the fish freshness index KI where [IMP], [HxR] and [Hx] are, respectively, the inosine 5′-monophosphate, inosine and hypoxanthine contents of fish meat was developed. The system consisted of a pair of chemiluminescence FIAs (CL-FIA); one for the measurement of [IMP] + [HxR] + [Hx], and the other for [HxR] + [Hx]. IMP, HxR or Hx were measured using a reactor comprising immobilized alkaline phosphatase, purine nucleoside phosphorylase (PNP) and xanthine oxidase (XOD). The calibration curves for IMP, HxR or Hx were linear from 0.06 μM to 100 μM for a sample volume of 20 μl. The time for a single KI measurement was less than 1 min. This fish freshness FIA system is rapid, convenient and applicable for fish freshness measurements in real fish samples.  相似文献   

4.
An enzyme biosensor was constructed using a plate platinum electrode and immobilized xanthine oxidase (XOD).Only a very small quantity of enzyme was chemically immobilized on a special silk net.Hydrogen peroxide released during the enzymatic reaction was detected by the electrode at+0.65 V (vs.Ag/AgCl).The electrode was very sensitive to hypoxanthine and its detection limit was 1×10-7 mol/L.When it was applied to the determination of fish freshness,the results agreed well with those obtained by traditional methods-determination of total volatile basic nitrogen (TVB-N) and microbial count.A range for estimating the freshness of river fish was suggested.  相似文献   

5.
Volpe G  Mascini M 《Talanta》1996,43(2):283-289
A simple and rapid procedure for the determination of fish freshness was developed and applied to the determination of the K(1) parameter (freshness indicator): K(1) = ([HXR] + [HX])/([IMP] + [HXR] + [HX]) x 100, where [IMP], [HXR] and [HX] are inosine monophosphate, inosine and hypoxanthine concentrations, respectively. A platinum electrode is used to detect hydrogen peroxide produced by the enzymatic reaction catalysed by xanthine oxidase immobilised on the electrode surface. The determination of inosine and inosine monophosphate was performed by the addition of nucleoside phosphorylase, 5'-nucleotidase or alkaline phosphatase to the buffer solution. Parameters such as type of buffer, amount of enzymes and sample treatment were optimised. With this procedure a linear response was obtained in the concentration range 1 x 10(-6)-2 x 10(-5)mol 1(-1) for hypoxanthine, inosine and inosine monophosphate. The detection limit was 5 x 10(-7) mol 1(-1).  相似文献   

6.
A hypoxanthine biosensor was constructed using immobilized xanthine oxidase and a polarographic electrode. The enzyme was covalently immobilized on a commercially available preactivated nylon membrane. The polarographic electrode detected hydrogen peroxide and uric acid released during the enzymatic reaction. The electrode responded linearly to hypoxanthine concentration in the range 3.6–107 μM. When applied to the determination of hypoxanthine in several fish meats, the results obtained agreed well with those obtained by the conventional enzymatic method. More than 40 assays could be performed with the same membrane and each sample could be assayed in ca. 2–3 min. The biosensor provides a reliable, simple, rapid and economical method for the measurement of hypoxanthine, a useful indicator of fish freshness.  相似文献   

7.
Pesticides are widely used in paddy field to control pests, diseases, weeds and other rice pathogens in minimizing a serious loss in rice production. The presence of pesticide residues and metabolites in rice, water, soil, currently represents a major environmental pollutant issues. It sometime will cause insect pest outbreaks in paddy field. An electrochemical enzyme inhibition sensor using screen-printed carbon working electrode with onboard carbon counter and silver–silver chloride pseudo-reference electrode for insecticides detection is described in this paper (Figure 1). The detection is based on the inhibition of insecticides used in paddy field towards acetyl-cholinesterase enzyme (AChE) with the presence of Acetylthiocholine Iodide (ATCh) substrate on the sensor surface. The mixtures of AChE enzyme (0.02 UmL-1), electron mediator, TCNQ (1mM) and polypyrrole matrix (75 mM) were electro- polymerized on the sensor surface with a constant potential of 1.0V for 20 minutes. The sensor was soaked for 5 minutes with insecticides standard or sample containing insecticides before the electrochemical measurement was taken by adding Acetylthiocholine Iodide substrate in KCl (0.08M, pH 7.5) which acts as the enzyme mediator /substrate system. The current measurement was conducted using chronoamperometry at 100mV vs. on board screen-printed Ag-AgCl pseudo- reference electrode. Comparative analysis of spiked water samples with 0.1ppm pesticides and real samples (paddy) also were conducted using enzyme inhibition sensor and gas chromatography methods. From the data analysis, it showed very comparable results with R2 = 0.96 in the correlation plot for paddy samples samples. This makes the developed sensor a potential tool for the rapid, simple and sensitive detection of insecticides residues in agriculture industry.  相似文献   

8.
We have developed screen-printed carbon electrodes for the determination of putrescine (Put) via the enzyme monoamine oxidase that was immobilized on the surface of the electrode by cross-linking it with bovine serum albumin using glutaraldehyde. A mixture of 5 % of tetrathiofulvalene (TTF) and carbon ink was used for the fabrication of the screen-printed working electrode. Put was amperometrically detected by measurement of the current due to the oxidation of the mediator TTF. The use of TTF lowers the working potential to +250 mV (vs. a screen-printed Ag/AgCl reference electrode). Response is linear in the range from 16 to 101 μM, and the detection limit is 17.2?±?4.6 μM, with a reproducibility of 9.6 % (n?=?4) in terms of relative standard deviation. The effects of potentially interfering biogenic amines such as cadaverine, histamine, spermine, spermidine and tryptamine were also evaluated. The biosensor was successfully applied to the determination of Put in zucchini and anchovies.
Figure
Amperometric determination of putrescine using a biosensor based on the immobilization of monoamine oxidase (MAO) enzyme on a disposable screen-printed carbon electrode modified with tetrathiofulvalene (TTF)  相似文献   

9.
Diffusion coefficient measurements in microfluidic devices   总被引:2,自引:0,他引:2  
A glassy carbon electrode (GCE) modified with Pd/IrO(2) provides excellent electrocatalytic oxidation of hydrogen peroxide. Glucose oxidase (GOD) and xanthine oxidase (XOD) were co-immobilized on the modified electrode with a thin film Nafion coated on the enzyme layer to form a glucose (Glu)/hypoxanthine (Hx) sensor, without interference from electroactive species such as ascorbic acid (AA) and uric acid (UA). Its response was evaluated with respect to the enzyme amount on the electrode, pH and temperature of the electrolyte. The prepared bienzymic biosensor, used as the detector of HPLC gave a detection limit of 1.0x10(-6) mol l(-1) Glu and 2.0x10(-7) mol l(-1) Hx (Hx) with a linear concentration range of 5.0x10(-6)-2.5x10(-3) mol l(-1) and 1.0x10(-6)-5.0x10(-4) mol l(-1), respectively. Coupled with microdialysis, it was used to monitor the concentrations of Glu and Hx in rat brain.  相似文献   

10.
A simple and automated methodology for a sensitive electrochemical detection of enzyme immunoassays that employ alkaline phosphatase (AP) as label has been developed. A flow injection system with programmable pump, valve and cell functions, amperometric detection of indigo and screen-printed electrodes (SPEs) are responsible for the advantages of this methodology. Amperometric detection at a low potential of indigo, the product of the enzymatic hydrolysis of the substrate 3-indoxyl phosphate (IP), is combined with a flow injection system. This incorporates in the flow cell a disposable screen-printed board provided with a graphite working electrode. No electrode pretreatment is necessary to obtain reproducible signals. The system was applied to the determination by an enzyme-linked immunosorbent assays (ELISA) of pneumolysin (PLY), a toxin related to respiratory infections. Linear calibration curves for low and high concentration ranges were obtained. These were also performed in a proteic matrix and linearity was also obtained.  相似文献   

11.
The development of a carbon paste-tetrathiafulvalene amperometric enzyme electrode for the determination of glucose in flowing streams is described. The enzyme electrode is operated in a flow-through detector based on the wall-jet configuration under flow injection (FI) and steady-state (SS) conditions. Under FI conditions, high precision (0.6%) and sample throughput (120 samples h-1) are possible. Moreover no pre-conditioning of the electrode is required. The flow system is suitable for the determination of glucose in whole blood without sample dilution. With proper orientation of the jet with respect to the enzyme electrode, high accuracy can be obtained under SS conditions.  相似文献   

12.
We report on the amperometric determination of sulfite using screen-printed carbon electrodes (SPCEs) modified with gold and silver nanoparticles that were deposited on the electrode to improve the capabilities of detection. The electrode is fairly selective and responds to sulfite with an oxidation current (at 300 mV and pH 6) in the 9.80 to 83.33 μM concentration range. The precision in terms of repeatability and reproducibility is 14.4 % and 10.7 % in the case of SPCEs modified by gold nanoparticles. The method was applied to the determination of sulfite in drinking water, pickle juice and vinegar. Recoveries ranged from 96 % to 104 %.
Figure
Amperometric determination of sulfite using a sensor based on the immobilization gold nanoparticles on a disposable screen-printed carbon electrode  相似文献   

13.
A multielectrode enzyme sensor for the simultaneous determination of adenosine-5′-phosphate (AMP), inosine-5′-phosphate (IMP), inosine (HXR) and hypoxanthine (HX)in fish meat was developed by assembling four enzyme sensors for AMP, IMP, HXR and HX in a flow cell. These compounds were determined from oxygen consumption according to the following reactions: AMP AD IMP NT HXR NP, PO3?4 HX XO, O2 Uric acid where AD is AMP deaminase, NT is 5′-nucleotidase, NP is nucleoside phosphorylase and XO is xanthine oxidase. Enzymes were covalently bound to a membrane prepared from cellulose triacetate, 1,8-diamino-4-aminomethyloctane and glutaraldehyde. Sensors for HX, HXR, IMP and AMP were prepared by attaching membranes of XO, XONP, XO NPNT, and of XONPNT and AD, respectively, to four oxygen electrodes. Samples extracted from sea bass, bream, flounder, abalone and arkshell were analyzed within 5 min, from the simultaneous response curves of the four electrodes. Results obtained by the multisensor system were in good agreement with those determined by each single electrode.  相似文献   

14.
The analytical performance of amperometric microcells with different electrode geometries is compared for enzyme activity measurements. The microcells were fabricated with thin film photolithography or thick film screen-printing in four different designs. The cells made with the thin film process used flexible substrate with microelectrode array or a circular, disk-shaped working electrode. The screen-printed working electrodes had semicircle or disk shape on ceramic chips. Putrescine oxidase (PUO) activity measurement was used as a model. The determination of PUO activity is important in the clinical diagnosis of premature rupture of the amniotic membrane. An electropolymerized m-phenylenediamine size-exclusion layer was used to eliminate common interferences. The size exclusion layer revealed also to be advantageous in protecting the electrodes from fouling by putrescine (enzyme substrate). The electrode fouling of bare electrodes was insignificant for screen-printed electrodes, but very severe for electroplated platinum working electrodes. The microelectrode array electrodes demonstrated smaller RSD and higher normalized sensitivities for hydrogen peroxide and PUO activity. All the other electrodes were demonstrating comparable analytical performances.  相似文献   

15.
The analytical performance of amperometric microcells with different electrode geometries is compared for enzyme activity measurements. The microcells were fabricated with thin film photolithography or thick film screen-printing in four different designs. The cells made with the thin film process used flexible substrate with microelectrode array or a circular, disk-shaped working electrode. The screen-printed working electrodes had semicircle or disk shape on ceramic chips. Putrescine oxidase (PUO) activity measurement was used as a model. The determination of PUO activity is important in the clinical diagnosis of premature rupture of the amniotic membrane. An electropolymerized m-phenylenediamine size-exclusion layer was used to eliminate common interferences. The size exclusion layer revealed also to be advantageous in protecting the electrodes from fouling by putrescine (enzyme substrate). The electrode fouling of bare electrodes was insignificant for screen-printed electrodes, but very severe for electroplated platinum working electrodes. The microelectrode array electrodes demonstrated smaller RSD and higher normalized sensitivities for hydrogen peroxide and PUO activity. All the other electrodes were demonstrating comparable analytical performances.  相似文献   

16.
Shi G  Liu M  Zhu M  Zhou T  Chen J  Jin L  Jin JY 《The Analyst》2002,127(3):396-400
A novel hypoxanthine (Hx) microsensor was constructed. In this work, Nafion xanthine oxidase (XOD) and Au colloid were immobilized onto the surface of a Pt microelectrode. The enzyme biosensor displayed a quick and sensitive response to Hx. Under physiological conditions, a low detection limit, with high selectivity and sensitivity for Hx determination were obtained. The oxidation current [investigated using current-time (I-t) plots] was linear with Hx concentration ranging from 2.0 x 10(-7) to 2.0 x 10(-5) mol L(-1) with a calculated detection limit of 1.0 x 10(-7) mol L(-1) (S/N of 3). The biosensor should be promising for in vivo measurement of Hx without interferences and fouling. The change of Hx concentration in cardiac myocytes stimulated by L-arginine (L-Arg) and acetylcholine (Ach) was also studied.  相似文献   

17.
Huang  Xiaojia  Zhu  Xiangyu  Pei  Miao 《Mikrochimica acta》2018,185(4):1-8
Microchimica Acta - The authors describe a highly sensitive method for the aptamer (Apt) based impedimetric determination of cocaine. The surface of a screen-printed electrode (SPE) was modified...  相似文献   

18.
A screen-printed electrode (SPE) was fabricated for the determination of 1-(ethoxycarbonyl)pentadecyltrimethylammonium bromide (Septonex) based on the use of Septonex-tetraphenylborate as the electroactive substance, and o-nitrophenyloctylether (o-NPOE) as the plasticizing agent. The electrode passes a near-Nernstian cationic slope of 59.33 ± 0.85 mV from activity between pH values of 2 to 9 with a lower detection limit of 9×10(-7) M and response time of about 5 s and exhibits an adequate shelf-life of 6 months. The method was applied for the determination of Septonex in pharmaceutical preparations. A percentage recovery of 99.88% was obtained with RSD=1.24%. The electrode was successfully applied in the determination of Septonex in laboratory-prepared samples by direct potentiometric, calibration curve and standard addition methods. Potentiometric titration of Septonex with sodium tetraphenylborate and phosphotungstic acid as a titrant was monitored with the modified screen-printed electrode as an end-point indicator electrode. Selectivity coefficients for Septonex relative to a number of potential interfering substances were determined. The sensor was highly selective for Septonex over a large number of compounds. Selectivity coefficient data for some common ions show negligible interference; however, cetyltrimethylammonium bromide and iodide ions interfere significantly. The analytical usefulness of the proposed electrode was evaluated by its application in the determination of Septonex in laboratory-prepared pharmaceutical samples with satisfactory results. The results obtained with the fabricated sensor are comparable with those obtained by the British Pharmacopeia method.  相似文献   

19.
A disposable, screen-printed electrode based on the immobilization of catalase or tyrosinase was developed to construct biosensors for the amperometric determination of azide. The determination principles for azide by these two methods are based on inhibiting the enzymatic consumption of an electrode-detectable substance (hydrogen peroxide or catechol) on an enzyme-immobilized electrode. Both of these methods show a sensitive detection range and a short measuring time.  相似文献   

20.
Cubukçu M  Timur S  Anik U 《Talanta》2007,74(3):434-439
A composite electrode was prepared by modifying glassy carbon microparticles with gold nanoparticles (Au-nps) and xanthine oxidase enzyme (XOD) for xanthine (X) and hypoxanthine (Hx) detection. After the optimization of the system for X, the biosensor was characterized for X and Hx. A linearity was obtained in the concentration range between 5.00 × 10−7 and 1.00 × 10−5 M for X with equation of y = 0.24x + 0.712 and 5.00 × 10−6 to 1.50 × 10−4 M for Hx, with equation of y = 0.014x + 0.575, respectively. Obtained results were compared to X and/or Hx biosensors including/not including Au-np in the structure. The developed system was also applied for detection of Hx in canned tuna fish sample and very promising results were obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号