首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 828 毫秒
1.
A competitive time-resolved fluoroimmunoassay (TR-FIA) was developed for the determination of 19-nortestosterone (17beta-NT) residues in aquaculture tissues. The limit of detection (LOD) was determined to be 0.08 ng g-1 and the limit of quantification (LOQ) was less than 0.8 ng g-1. The results obtained by the TR-FIA and ELISA showed a good correlation. The established TR-FIA was validated for the determination of incurred aquaculture tissues and confirmed by liquid chromatography tandem mass spectrometry (LC/MS/MS). This proposed technique could be applied to routine residue analysis.  相似文献   

2.
Shen J  Zhang Z  Yao Y  Shi W  Liu Y  Zhang S 《Analytica chimica acta》2006,575(2):262-266
A time-resolved fluoroimmunoassay (TR-FIA) for determination of chloramphenicol (CAP) in shrimp and chicken muscle was developed. The method was based on a direct competitive immunoassay using europium-labeled anti-CAP monoclonal antibody (MAb) and CAP-ovalbumin as coated antigen. The limit of detection was 0.05 ng g−1 and limit of quantification was 0.1 ng g−1. Recoveries ranged from 101.2 to 112.5% for shrimp and 104.9 to 115.3% for chicken muscle at spiked levels of 0.1-5 ng g−1, with intra-assay and inter-assay variations 8.7-14.6 and 9.6-17.8%, respectively. The results obtained by the TR-FIA and ELISA correlated well. The established TR-FIA was validated for the determination of incurred shrimp samples and confirmed by gas chromatography with microcell electron capture detector (GC-μECD).  相似文献   

3.
A simple dry chemistry time-resolved fluorescence immunoassay (TR-FIA) method was developed for the measurement of zeranol in bovine urine samples. The samples were purified by immunoaffinity chromatography and a specificity-enhanced zeranol antibody was employed in the immunoassay. This resulted in a highly selective method, which had only negligible reactivity with Fusarium spp. toxins. The all-in-one-well dry chemistry concept made the assay very simple to use because all the assay-specific reagents were already present in the reaction wells in dry form. Only the addition of diluted sample extract was required to perform the competitive one-step TR-FIA and the results were available in less than 1 h. The analytical limit of detection (mean + 3s) for the immunoassay was 0.16 ng ml(-1) (n = 12) and the functional limit of detection for the whole method, estimated by the analysis of zeranol-free samples, was 1.3 ng ml(-1) (n = 20). The recovery of zeranol at the level of 2 ng ml(-1) was 99% (n = 18) and the within-assay variation ranged between 4.5 and 9.0%.  相似文献   

4.
Gentamicin is a broad-spectrum aminoglycoside antibiotic widely used in veterinary medicine for the treatment of serious infections. The purpose of this study was to develop and validate a method to determine gentamicin residues in edible tissues of swine and calf. Extraction of gentamicin was performed using a liquid extraction with phosphate buffer containing trichloroacetic acid, followed by a solid-phase clean-up procedure on a CBA weak cation-exchange column. Tobramycin was used as the internal standard. After drying of the eluate, the residue was redissolved and further analyzed by reversed-phase liquid chromatography/electrospray ionization tandem mass spectrometry (MS/MS). Chromatographic separation of the internal standard tobramycin and the gentamicin components was achieved on a Nucleosil (5 microm) column using a mixture of 10 mM pentafluoropropionic acid in water and acetonitrile as the mobile phase. The gentamicin components C1a, C2 + C2a and C1 could be identified with the MS/MS detection, and subsequently quantified. The method was validated according to the requirements of the EC at the maximum residue limit (MRL) (100 ng g(-1) for muscle and fat, 200 ng g(-1) for liver and 1000 ng g(-1) for kidney), half the MRL and double the MRL levels. Calibration graphs were prepared for all tissues and good linearity was achieved over the concentration ranges tested (r > 0.99 and goodness of fit <10%). Limits of quantification of 25.0 ng g(-1) were obtained for the determination of gentamicin in muscle, fat, liver and kidney tissues of swine and calf, which correspond in all cases to at least half the MRLs. Limits of detection ranged between 0.5 and 2.5 ng g(-1) for the tissues. The within-day and between-day precisions (RSD) and the results for accuracy fell within the ranges specified. The method was successfully used for the determination of gentamicin in tissue samples of swines and calves medicated with gentamicin by intramuscular injection.  相似文献   

5.
Terbinafine and N-demethyl terbinafine concentrations were determined simultaneously in rat tissues by a high-performance liquid chromatography method. This method involved the homogenization of tissues (except for skin) followed by a liquid-liquid extraction. Skin samples were dissolved in sodium hydroxide prior to extraction. Terbinafine and its N-demethylated metabolite were assayed using a C(18) reversed-phase column with a mobile phase of acetonitrile and water (40:60) containing ortho phosphoric acid (0.02 M) and triethylamine (0.01 M), and UV detection (at 224 nm). The standard curve for the assay (constructed using clotrimazole as internal standard) was linear over the concentration range 100-3000 ng/g in skin and 10-600 ng/g in all other tissues. The inter- and intra-day precision for both terbinafine and metabolite was between 0.2% and 16%. The limit of quantification was 10 ng/g in all tissues and 100 ng/g in skin. This assay was found to be reliable and reproducible for the determination of terbinafine and N-demethyl terbinafine concentration in all rat tissues and has been used for tissue distribution studies.  相似文献   

6.
A gas chromatography method with microcell electron capture detection was developed for the determination of chloramphenicol residue in fish and shrimp muscle tissues. The tissue samples were extracted with ethyl acetate, defatted with hexane, and derivatized with Sylon BFT [N,O-bis (trimethylsilyl) trifluoroacetamide-trimethylchlorosilane (99 + 1)]. The limit of detection was 0.04 ng/g and the limit of quantitation 0.1 ng/g. Average recoveries were 70.8-90.8% for fish and 69.9-86.3% for shrimp, respectively. The method was validated for the determination of practical samples.  相似文献   

7.
This study describes the development and validation of a time-resolved fluoroimmunoassay (TR-FIA) for screening ractopamine (RAC) in swine tissue. The method is based on the direct competitive-type immunoassay using europium-labeled anti-RAC monoclonal antibody as a tracer and RAC–ovalbumin as a solid-phase antigen. When RAC was spiked at levels of 1–10 μg kg−1, recoveries ranged from 88.2 to 118.5% for swine liver and muscle with coefficients of variation from 7.1 to 20.5%. The detection limit was 0.1 μg kg−1. The proposed TR-FIA method was applied to the determination of RAC in an actual residue study and the applicability was confirmed by liquid chromatography–tandem mass spectrometry.  相似文献   

8.
Headspace solid phase microextraction (HS-SPME) in-situ supercritical fluid extraction (SFE) was investigated for the determination of trace amounts of perfluorocarboxylic acids (PFCAs) in sediments. Quantitation was performed by using gas chromatography coupled to negative chemical ionization-tandem mass spectrometry (GC-NCI-MS/MS). The optimum conditions of HS-SPME following SFE were obtained using 500 μL n-butanol as a derivatization reagent in supercritical carbon dioxide with static extraction for 10 min, then dynamic extraction for 20 min at 30 MPa and 70 °C and simultaneous collected with 100 μm film thickness PDMS fiber. The linear range of proposed method was from 5 to 5000 ng g(-1), with limit of detection ranging from 0.39 to 0.54 ng g(-1) and limit of quantitation ranging from 1.30 to 1.80 ng g(-1). The developed method was successfully applied to analyze PFCAs in sediments from rivers and beach near industrial areas. The concentrations of PFCAs determined are from 282 to 4473 ng g(-1).  相似文献   

9.
Dihydrostreptomycin (DHS) is an aminoglycoside antibiotic used in veterinary medicine in combination with benzylpenicillin for the treatment of bacterial infections in cattle, pigs and sheep. A method to determine its residues in edible tissues of cattle, as well as in milk, was developed and validated. Extraction of DHS from the tissues was performed using a liquid extraction with a 10 mM phosphate buffer containing 2% (w/v) trichloroacetic acid, while milk samples were treated with a 50% (w/v) trichloroacetic acid solution, followed by a solid-phase clean-up procedure on a carboxypropyl (CBA) weak cation exchange column. Ion-pair chromatography, using a mixture of 20 mM pentafluoropropionic acid in water and acetonitrile as the mobile phase, was used to retain DHS and the internal standard streptomycin (STR) on a Nucleosil (5 microm) reversed-phase C18 column. The components were detected and quantified by electrospray ionization (ESI) tandem mass spectrometry. The method could be validated according to EC (European Community) requirements with respect to linearity, trueness and precision, the latter evaluated at the maximum residue limit (MRL) - 1000 ng g(-1) for kidney, 500 ng g(-1) for muscle, liver and fat, and 200 ng g(-1) for milk -, at one-half of the MRL and at one and a half times the MRL. A limit of quantification of 10 ng g(-1) and 1 ng ml(-1) was obtained for all tissues and for milk, respectively, which is far below one-half of the MRL as requested, while the limit of detection was in the low ppb range, varying between 1.9 and 4.2 ng g(-1) for the different tissues tested, and being 0.6 ng ml(-1) for milk. The method was used for the monitoring of DHS residues in incurred tissue and milk samples coming from cattle medicated with DHS in combination with benzylpenicillin by intramuscular injection, in order to evaluate withdrawal times.  相似文献   

10.
A liquid chromatography (LC) method is presented for the quantitative determination of malachite green (MG) in salmon. MG and leucomalachite green (LMG) residues were extracted from salmon tissue with ammonium acetate buffer and acetonitrile, and then isolated by partitioning into dichloromethane. LMG was quantitatively oxidized to the chromic MG by reaction with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone. Samples were then cleaned up by solid-phase extraction with alumina and propylsulfonic acid phases. Extracts were analyzed for MG by LC with visible detection at 618 nm using isocratic elution and a C18 column. The method was validated in 35 farm-raised salmon (Salmo salar) tissues fortified at 1, 2, 4, and 10 ng/g (ppb) with an average recovery of 95.4% and a relative standard deviation of +/- 11.1%, and in 5 canned salmon (Oncorhynchus gorbuscha) samples fortified at 10 ng/g with an average recovery of 88.9 +/- 2.6%. This study also included the determination of MG and LMG residues in tissues from salmon that had been treated with MG MG was quantitatively determined at the method detection limit of 1 ng/g.  相似文献   

11.
Based on the optimized spectrophotometric determination of pyrogens (of various classes ( p-aminophenol and endotoxins), thermal lensing was applied to the determination of these substances at the submicrogram level. The limit of detection of p-aminophenol, a pyrogenic impurity in pharmaceutical formulations of paracetamol, by reaction with resorcinol in alkaline solutions is 100 ng mL(-1). Phloroglucinol was considered as an analog of resorcinol as a reagent in this reaction. The conditions of spectrophotometric determination of pyrogenic lipopolysaccharides (endotoxins) by ion-pair formation with methylene blue (the limit of detection is 100 ng mL(-1)), by ion-pair formation with Stains-All (1-ethyl-2-[3-(1-ethylnaphtho[1,2-d]thiazolin-2-ylidene)-2-methylpropenyl]naphtho[1,2-d]thiazolium bromide) (the limit of detection is 500 ng mL(-1)), and by reaction of 2-keto-3-deoxyoctonic acid with thiobarbituric acid (the limit of detection is 800 ng mL(-1)) were proposed. The optimized procedure for 2-keto-3-deoxyoctonic acid was applied for thermal lensing that provided a decrease in the limit of detection to 70 ng mL(-1) and was also used for lipopolysaccharide determination in the endotoxin standard from E. coli.  相似文献   

12.
Decanoic acid reverse micelle-based coacervates were proposed for the extraction of bisphenol A (BPA) from canned vegetables and fruits prior to its determination by liquid chromatography and fluorescence detection at lambda(exc) = 276 nm and lambda(em) = 306 nm. The procedure involved the extraction of minute quantities (300-700 mg) of homogenized food sample with an aqueous solution containing 10% of THF and 0.5% of decanoic acid, conditions under which the coacervate (around 340 microL) formed in situ and instantaneously. The overall sample treatment, which included extraction and centrifugation, took about 25-30 min, and several samples could be simultaneously treated using conventional lab equipment. No clean-up or solvent evaporation were required. Extraction efficiencies mainly depended on the decanoic acid and THF concentration in the aqueous solution and were not affected by the pH or the temperature in the ranges studied (1-4 and 20-60 degrees C, respectively). Recoveries in samples ranged between about 81 and 96%. The precision of the method, expressed as relative standard deviation, was about 3% and the quantitation limit was around 9 ng g(-1), which was far below the current specific migration limit (SML) set for BPA by the EU Commission (600 ng g(-1)). The method was successfully applied to the determination of BPA in the solid content of canned fruit salad, peaches in syrup, mango slices, red peppers, sweetcorn, green beans and peas. BPA was present at concentrations in the range from 7.8 to 24.4 ng g(-1) in canned fruits and from 55 to 103 ng g(-1) in canned vegetables.  相似文献   

13.
A new analytical method for the determination of piperine and its isomers in egg yolk and albumen is described here. All four isomers were separated by HPLC and detected using UV, DAD and electrochemical detection. The absolute detection limit (UV detection, S/ N=3) of a standard solution of piperine was 370 pg piperine. The correlation coefficients for the linear calibration graphs (concentration range: c=100 ng-10 micro g piperine isomer/mL) are generally better than 0.996. The piperine isomers were characterized and identified by spectroscopy (MS, (1)H-NMR, FT-IR). The method was successfully applied to the determination of piperine deposits in eggs (egg yolk and albumen) after feeding hens with piperine-spiked feed. The detection limit for piperine (24.8(+/-0.2) ng/g egg yolk and 37.9(+/-4.9) ng/g albumen) and the recoveries (70.3(+/-7.7)% (egg yolk) and 75.7(+/-1.9)% (albumen)) of piperine were determined.  相似文献   

14.
A reliable and sensitive capillary gas chromatographic-mass spectrometric method was developed for the detection and determination of diazepam and its major metabolite, N-desmethyldiazepam, in human material. Medazepam served as the internal standard. Quantitative determination was achieved using mass fragmentography with selected ions of m/z 256 for diazepam and m/z 242 for N-desmethyldiazepam and medazepam. The limit of detection was 1 ng/g and the recoveries were 98.54 +/- 3.95% for diazepam and 98.66 +/- 6.48% for N-desmethyldiazepam. The calibration graph was linear over the concentration range from 1.0 ng/g to 1.0 microgram/g for diazepam and N-desmethyldiazepam. Using this method, trace amounts of diazepam and N-desmethyldiazepam were detected in the tissues of an autopsied individual.  相似文献   

15.
The development and validation of an assay for the determination of paclitaxel in human plasma, human brain tumor tissue, mouse plasma and mouse brain tumor tissue is described. Paclitaxel was extracted from the matrices using liquid-liquid extraction with tert-butyl methyl ether, followed by chromatographic analysis using an alkaline eluent. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicate that calibration standards in human plasma can be used to quantify paclitaxel in all tested matrices. In human samples, the validated range for paclitaxel was from 0.25-1000 ng ml(-1) using 200 microl plasma aliquots and from 5 to 5000 ng g(-1) using 50 microl tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma). In mice, the ranges were 1-1000 ng ml(-1) and 5-5000 ng g(-1) using 50 microl of mouse plasma and 50 microl of tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma), respectively. The method can be applied to studies generating only small sample volumes (e.g. mouse plasma and tumor tissue), but also to studies in human plasma requiring a lower limit of quantitation. The assay was applied successfully to several studies with both human and mouse samples.  相似文献   

16.
Zhang B  Xu H  Yu JC 《Talanta》2002,57(2):323-331
A new analytical method has been developed for the determination of total gaseous selenium in the atmosphere by honeycomb denuder collection followed by differential pulse cathodic stripping voltammetry (DPCSV) measurement. Gaseous selenium was collected in a denuder coating solution containing 2% HNO(3) and 2% glycerine. The soluble product, selenious acid, was then extracted by water for DPCSV analysis. The collection efficiency for gaseous selenium was 99.1% at a flow rate of 1 l min(-1) for 3 h. Excellent linearity in DPCSV was maintained up to Se concentration of 40 ng ml(-1). This was equivalent to a working concentration of 220 ng m(-3) of selenium in the atmosphere. A precision of 1.26% RSD (n=5) for 5 ng Se was obtained, and the detection limit (3sigma) and the quantitative determination limit were estimated to be 0.96 and 3.19 ng m(-3). The average recovery of selenium in three standard samples prepared by independent digestion of NIST SRM 1648 (Urban Particulate Matter) using our analytical system was 99.0%. The total content of gaseous selenium in the atmosphere of our laboratories was 3.2-4.4 ng m(-3).  相似文献   

17.
The synthesis and evaluation of a molecularly imprinted polymer (MIP) as a selective matrix solid-phase dispersion (MSPD) sorbent, coupled with high-performance liquid chromatography for the efficient determination of chloramphenicol (CAP) in fish tissues are studied. The polymer was prepared using CAP as the template molecule, vinylpyridine as the functional monomer and ethylene glycol dimethacrylate as the cross-linking monomer, and sodium dodecyl sulfate as the surfactant in the presence of water as a solvent by miniemulsion polymerization. The CAP-imprinted polymers and nonimprinted polymers (NIPs) were characterized by Fourier transform IR spectroscopy, scanning electron microscopy, and static adsorption experiments. The CAP-imprinted material prepared showed high adsorption capacity, significant selectivity, and good site accessibility. The maximum static adsorption capacity of the CAP-imprinted and the NIP material for CAP was 78.4 and 59.9 mg g(-1), respectively. The relative selectivity factors of this CAP-imprinted material were larger than 1.9. Several parameters influencing the MSPD process were optimized. Finally, the CAP-imprinted polymers were used as the sorbent in MSPD to determine CAP in three kinds of fishes and resulted in satisfactory recovery in the range 89.8-101.43%. CAP-imprinted polymer as a sorbent in MSPD is better than C18 and attapulgite in terms of both recovery and percent relative standard deviation. The baseline noise was measured from a chromatogram of a blank fish sample which was treated after the MSPD procedure using CAP-imprinted polymer as a sorbent. Signal values of 3 times the noise (signal-to-noise ratio of 3) and 10 times the noise (signal-to-noise ratio of 10) were used to calculate the limit of detection and the limit of quantitation of the calibration curve. The limit of detection for CAP was 1.2 ng g(-1) and the limit of quantitation was 3.9 ng g(-1).  相似文献   

18.
It is generally supposed that the preconcentration procedure is used for the determination of metal concentrations under the sensitivity of the measurement method. This study showed that preconcentration is also need for the beryllium (Be) concentration over the sensitivity of atomic absorption spectrometry. For this purpose, a simple and selective method for the determination of Be in solid samples is modified. The method is based on the preconcentration of the complexes of beryllium-acetylacetone plus morin, oxine, PAN and PAR on activated carbon at different pH values. The adsorbed beryllium was eluted with aqua regia and measured by flame atomic absorption spectrometry (FAAS). Recoveries of up to 85% were achieved. For removing chemical interferences and applying the method to Be determination in solid samples, the masking studies and reproducibility were examined. The detection limit was found to be 0.12 ng mL(-1). The relative sandard deviations (RSD) were found to be 8% for 60 mL of 10.0 ng mL(-1) using 10 replicate enrichment procedures. Beryllium concentrations in the studied solid samples were found in the range of 0.28 - 3.95 mg kg(-1).  相似文献   

19.
A fast high-performance liquid chromatography method has been devised for the determination of ochratoxin A (OTA) in Italian salami in the low part-per-trillion (pg/g) level. The samples were extracted with ethyl acetate and purified by immunoaffinity column (IAC). The IAC eluate could be directly injected or previously concentrated 10-fold. Recovery at 0.5 and 1 ng/g was 77 +/- 4%. The between-day coefficient of variation measured over 5 days on samples spiked at 1 ng/g was 8%. The developed method required a relatively small volume of non-halogenated organic solvent and the whole procedure was simpler and faster compared to other existing procedures. The limit of detection was 0.06 ng/g that could be even lowered using a preconcentration step. A total of 30 salami samples were analysed using this procedure; the most contaminated sample was found to have OTA concentration at 0.4 ng/g level.  相似文献   

20.
This study describes the development of a sensitive liquid chromatography-electrospray-tandem mass spectrometry method for the simultaneous determination of benzyl butyl phthalate (BBP) and its major metabolites, monobenzyl phthalate (MBzP) and monobutyl phthalate (MBuP), in rat plasma, urine, and 10 different tissues. The method was validated with regard to the specificity, linearity, precision, accuracy, lower limit of quantification (LLOQ), recovery, and stability by using the matrix-matched quality control samples. The assay achieved LLOQ of 1 ng/ml of BBP for plasma and urine, 4 ng/g for kidney and liver, 10 ng/g for fat, and 20 ng/g for all other tissues. For MBzP and MBuP, the assay achieved LLOQ of 5 ng/ml for plasma and urine, 10 ng/g for fat, and 20 ng/g for all other tissues. The disposition of BBP was characterized by a large volume of distribution (71.1–82.9 l/kg) and a high clearance (838.7–871.0 ml/min/kg). It was extensively metabolized to MBzP and MBuP, with their levels consistently exceeding the BBP levels. The distribution of BBP, MBzP, and MBuP to tissues of kidney, liver, stomach, small intestine, large intestine, spleen, brain, testis, thyroid, and fat was determined under steady-state conditions. For BBP, the steady-state tissue-to-plasma partition coefficient (K p) was the highest for fat (25.0) followed by small intestine (2.6), thyroid (2.0), and stomach (1.1). In contrast, for MBzP and MBuP, it was the highest for kidney (2.0 and 4.3, respectively) and liver (4.3 and 2.1, respectively) but was less than unity for all other tissues. The developed assay method and findings of this study may be useful to evaluate the exposure and toxic potential of BBP and its metabolites in risk assessment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号