首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Hongtao Fan  Weijia Li  Shuang Jin 《Talanta》2009,79(5):1228-35
An aqueous solution containing sodium polyacrylate (PA, 0.0030 M) was used in diffusive gradients in thin-films technique (DGT) to measure DGT-labile Cu2+ and Cd2+ concentrations. The DGT devices (PA DGT) were validated in four types of solutions, including synthetic river waters containing metal ions with or without complexing EDTA, natural river water (Hun River, Shenyang, China) spiked with Cu2+ and Cd2+, and an industrial wastewater (Shenyang, China). Results showed that only free metal ions were measured by PA DGT, recovery = 98.79% for Cu2+ and recovery = 97.80% for Cd2+ in solutions containing only free metal ions, recovery = 51.02% for Cu2+ and recovery = 51.92% for Cd2+ in solution with metal/EDTA molar ratio of 2:1 and recovery = 0 in solutions with metal/EDTA molar ratio of 1:1 and 1:2. These indicated that the complexes of Cu-EDTA and Cd-EDTA were DGT-inert or not DGT-labile. The DGT performance in spiked river water (recovery = 8.47% for Cu2+ and recovery = 27.48% for Cd2+) and in industrial wastewater (recovery = 14.16% for Cd2+) were also investigated. Conditional stability constants (log K) of PA-Cu and PA-Cd complexes were determined as 6.98 and 5.61, respectively, indicating strong interaction between PA and the metals.  相似文献   

2.
Li W  Zhao H  Teasdale PR  Wang F 《Talanta》2005,67(3):571-578
The speciation measurements of trace metals by the diffusive gradients in thin-films technique (DGT) using a poly(4-styrenesulfonate) (PSS) aqueous solution as a binding phase and a cellulose dialysis membrane (CDM) as a diffusive layer, CDM-PSS DGT, were investigated and showed good agreement with computer modelling calculations. The diffusion coefficients of ethylenediaminetetraacetic acid (EDTA) complexes with Cd2+ and Cu2+ were measured and compared with those of the inorganic metal ions. CDM-PSS DGT device was tested for speciation measurement in sample solutions containing EDTA, tannic acid (TA), glucose (GL), dodecylbenzenesulfonic acid (DBS) and humic acid (HA) as complexing ligands forming organic complexes with varying stability constants. Lower percentages of DGT labile copper concentrations over total filterable copper concentrations obtained from the deployments in freshwater sites indicated that copper complexes with organic matter were basically not measured by the devices.  相似文献   

3.
Since its invention in the mid-1990s, the diffusive gradients in thin films (DGT) technique has rapidly become one of the most promising in situ sampling techniques for trace metal measurement in natural waters. We investigated here the possibility of using DGT devices with different binding phases to determine different DGT labile fractions of Cd and Cu in laboratory solutions and in natural waters. Several binding phases were studied, including conventional Chelex 100 resin imbedded polyacrylamide hydrogel (Chelex) and several recently developed binding phases, poly(acrylamide-co-acrylic acid) (PAM-PAA) gel, poly(acrylamidoglycolic acid-co-acrylamide) (PAAG-PAM) gel, Whatman P81 cellulose phosphate ion-exchange membrane (P81), and poly(4-styrenesulfonate) (PSS) aqueous solution. Laboratory testing in metal solutions spiked with EDTA or humic acid suggested that all the DGT devices measured only free metal ions and inorganic metal complexes. Upon field testing at both freshwater and seawater sites it was found that the DGT labile metal concentrations measured by different binding phases can be significantly different, suggesting that the DGT labile metal fractions were dependent on binding strength of the binding phase. By designing binding phases that can compete with different natural water complexing ligands to varying extents, it is possible to use these different DGT devices to measure metal speciation in natural waters.  相似文献   

4.
The diffusion gradients in thin films (DGT) method was investigated and used to measure trace metal concentrations in river water. The principle of DGT is that trace metal ions diffuse through a thin polyacrylamide gel film (the diffusion gel layer) and are subsequently immobilised and concentrated on a layer of Chelex-100 resin embedded in another polyacrylamide gel film (the resin gel layer). These layers are mounted in a plastic holder, which exposes a fixed area of the diffusion gel layer to the water being monitored. Replacement of the normal agarose cross-linked diffusion gel with bisacrylamide cross-linked gel altered the ion uptake properties of DGT. The bisacrylamide cross-linked gel weakly, and with little selectivity, bound metal ions prior to their irreversible binding to Chelex-100. Trace metal ion uptake by these DGT devices was thus dependent on ionic strength and temperature, although the ionic strength effect is relatively small for most natural waters and negligible in sea water. The concentrations of Cd, Co, Cu, Ni, Pb, and Zn in the Water of Leith, an urban stream in Dunedin, New Zealand, were measured by DGT and the results compared with total dissolved concentrations of these metals measured in conventional (bottle) samples collected in parallel with the DGT monitoring. Greater than 90% of the total dissolved Cd and Zn; 20-40% of the total dissolved Co, Ni, and Pb; and 5% of the total dissolved Cu was available to the DGT method.  相似文献   

5.
Diffusive gradients in thin films (DGT) and tangential-flow ultrafiltration (TF-UF) were combined for fractionation of Al and Cu in river water containing high content of dissolved organic carbon. A procedure based on ultrafiltration data is proposed to determine diffusion coefficients of the analytes in water samples and model solutions containing both free metal (M) and complex (metal - humic substance). Aiming to evaluate the accuracy of the proposed approach, the DGT results were compared with those from a protocol for determination of labile Al and Cu based on solid phase extraction (SPE). Good agreement between data from DGT and SPE were attained for model solutions. For analysis of real organic-rich water samples, differences between DGT and SPE measurements were consistent with the time-scales of the techniques. The concentration of labile Al determined by DGT were lower than the total dissolved concentrations (determined by inductively coupled plasma mass spectrometry) and exceeded the ultrafiltered concentration, indicating that inorganic Al species (species small enough to pass through 1 kDa membrane) were minor species as compared with Al organic complexes. For both Al and Cu, there were species not measured by DGT as they are not sufficiently labile.  相似文献   

6.
Herein we describe the reversible changing of DNA duplex thermal stability by exploiting transition metal complexation phenomena. A terpyridine ligand was conjugated to the N2'-atoms of 2'-amino-2'-deoxyuridine and its locked counterpart 2'-amino-LNA, and these metal-complexing monomers were incorporated into oligodeoxyribonucleotides. Upon addition of varying amounts of transition metal ions, the thermal stability of DNA duplexes containing these terpyridine-functionalized units in different constitutions was affected to different degrees (DeltaTm values = -15.5 to +49.0 degrees C, relative to the unmodified duplex). The most pronounced effects were observed when two complexing monomers were positioned in opposite strands. Addition of 1 equiv of Ni2+ to such a system induced extraordinary duplex stabilization. Molecular modeling studies suggest, as an explanation for this phenomenon, formation of nickel-mediated interstrand linkages in the minor groove. Addition of an excess of metal ions resulted in largely decreased Tm values. Alternating addition of metal ions and EDTA demonstrated reversibility of metal ion-induced changes in hybridization strength, proving that the described approach provides an efficient method for duplex stability modulation.  相似文献   

7.
Zhang M  Liu YQ  Ye BC 《The Analyst》2012,137(3):601-607
A colorimetric assay has been developed for parallel detection of Cd(2+), Ni(2+) and Co(2+) utilizing peptide-modified gold nanoparticles (P-AuNPs) as a sensing element based on its unique surface plasmon resonance properties. The functional peptide ligand, CALNNDHHHHHH, was self-assembled on gold nanoparticles (AuNPs) to produce P-AuNPs probe. The P-AuNPs probe could be used to simultaneously detect and showed different responses to the three ions Cd(2+), Ni(2+) and Co(2+) in an aqueous solution based on the aggregation-induced color change of AuNPs. The method showed good selectivity for Cd(2+), Ni(2+) and Co(2+) over other metal ions, and detection limit as low as 0.05 μM Cd(2+), 0.3 μM Ni(2+) or 2 μM Co(2+). To simultaneously (or parallel) detect the three metal ions coexisting in a sample, EDTA and imidazole were applied to mask Co(2+) and Ni(2+) for detecting Cd(2+), glutathione and EDTA were applied to mask Cd(2+) and Co(2+) for detecting Ni(2+), and glutathione and imidazole were applied to mask Cd(2+) and Ni(2+) for detecting Co(2+). Finally, the simple and cost-effective probe could be successfully applied for simultaneously detecting Cd(2+), Ni(2+), and Co(2+) in river water. Because this novel P-AgNPs-based probe design offers many advantages, including simplicity of preparation and manipulation compared with other methods that employ specific strategies, the sensing system shows potential application in the developing region for monitoring water quality.  相似文献   

8.
Docekalová H  Divis P 《Talanta》2005,65(5):1174-1178
The diffusive gradient in thin films (DGT) technique was investigated and used to measure mercury concentration in river water. Mercury ions are covalently bound to amide nitrogen groups of commonly used polyacrylamide, which makes this gel unsuitable as a diffusive medium. In contrast, agarose gel was found as the diffusive gel for mercury measurements. Basic performance tests of agarose DGT verified the applicability of Fick's first law for DGT measurements. Two selective resins, Chelex-100 with iminodiacetic groups and Spheron-Thiol with thiol groups were used. The measured diffusion coefficient in agarose gel was close to that in water. The concentration of mercury in Svitava river measured by DGT with Speron-Thiol resin gel was higher (0.0116 ± 0.0009 μg l−1) than those obtained by Chelex-100 (0.0042 ± 0.0005 μg l−1). Different capture efficiencies of two adsorbents enable to estimate fractions of mercury bonded in different complexes in the river water. The concentrations of mercury found by DGT both Chelex-100 and Speron-Thiol resin gels are much lower than that measured directly in the river water (0.088 ± 0.012 μg l−1). This difference indicates that DGT concerns inorganic ions and labile species only, and that it is not able to include inert organic species and colloids.  相似文献   

9.
Cu2+、Pb2+和Ni2+等重金属离子可与水中乙二胺四乙酸、柠檬酸、酒石酸等有机分子形成络合态重金属。相比于游离态离子,络合态重金属具有更高的水溶性和环境毒性,在广泛的pH值范围内稳定存在且形态复杂,难以通过化学沉淀等常规方法高效去除。对近年来基于金属组学方法的水中络合态重金属复杂形态分析方法进行总结,对吸附净化技术在络合态重金属废水处理中的研究进展进行综述,并对上述领域需要解决的问题进行了探讨和展望。  相似文献   

10.
The diffusive gradients in thin films (DGT) technique, using a diffusive gel or a restrictive gel, was evaluated for the determination of labile inorganic and organic species of Al and Cu in model synthetic solutions and river water samples. Experiments were performed both in situ and in the laboratory. In the solutions containing Al ions, the major labile fraction consisted of inorganic species. The organic complex fractions were mainly kinetically inert. For the model Cu solutions, the most labile fraction consisted of inorganic species; however, significant amounts of labile organic complexes of Cu were also present. A comparison was made between the results obtained using restrictive gel DGT and tangential flow ultrafiltration (TF-UF). The Cu fraction determined by restrictive gel DGT (corresponding to the "free" ions plus the labile fraction of small molecular size complexes) was larger than that determined by TF-UF (corresponding to all small molecular size ions), suggesting that the techniques exhibited different porosities for discrimination of inorganic species. For the river water samples analyzed in the laboratory, less than 45% of the analytes were present in labile forms, with most being organic species. For the in situ measurements, the labile inorganic and organic fractions were larger than those obtained in the laboratory analyses. These differences could have been due to errors incurred during sample collection and storage. All results were consistent with those found using two different methods, namely, solid-phase extraction and the DGT technique employing the apparent diffusion coefficient.  相似文献   

11.
The effect of ionic strength, pH and complexing ligands on the dialysis of metal ions, particularly zinc(II), through cellulose acetate membranes, was studied under flow conditions. The dialysis factor, which depends on both the mass transfer and the membrane permeability, was found to be independence of ionic strength in the interaval 0.05–0.3 M and to increase only slightly with pH 4.6 and 7.0. Some common buffer constituents had no effect, but chloride and calcium ions affected the transfer rates. The rate of transfer of the ligands histidine, NTA and EDTA was of the same order of magnitude as that of the metal ions. The transfer rate of the Ni(II)-EDTA complex was the same as that of a mixture of Ni(II) and EDTA. Generally, addition of the chelating agents decreased the metal-ion transfer rates. Partition coefficients between the membrane polymer and the buffers were evaluated and compared with the dialysis factors and there were significant differences with regard to the range of variation, effect of concentration and pH-dependence. The time scale of uptake or release of metal ions by the polymer is much longer than that of a steady-state transfer in dialysis. Partition and dialysis may not be directly related to each other.  相似文献   

12.
An experimental design using passive samplers was set up in our laboratories with the aim of preparing a procedure for the assessment of trace metals bioavailability in freshwater sediments. Trace metal (Cd, Cu, Pb, Ni, and Zn) bioavailability in sediment samples were measured by diffusive gradients in thin films (DGT) devices and compared to those simultaneously extracted (SEM) in 1N HCl with acid-volatile sulfide (AVS). During experiments DGT devices were exposed at various times (from 4 to 336 h) in sediments with different physical and chemical properties and metal content, after equilibration with ambient water (1:2) for 24 h. Trace metal were progressively accumulated in DGT units and after at least 24-48 h metal fluxes became constant. No relation was found between metal available fractions measured by DGTs and total concentrations in sediments or pore waters. On the contrary good relations were found between available metals measured by DGT and metals simultaneously extracted (SEM) in HCl 1N with acid volatile sulfide (AVS).  相似文献   

13.
Development of a guanine nanowire (G-wire) that is controllable and can be switched by external signals is important for the creation of molecular electronic technologies. Here, we constructed a G-wire in which the thymines of the main chain of d(G4T4G4) were replaced with 2,2'-bipyridine units, which have two aromatic rings that rotate arbitrarily upon coordination with metal ions. Circular dichroism of the DNA oligonucleotides with or without the 2,2'-bipyridine unit showed that divalent metal ions induce the bipyridine-containing oligonucleotide to switch from an antiparallel to a parallel G-quadruplex. Native polyacrylamide gel electrophoresis showed that the parallel-stranded G-quadruplex DNA had a high-order structure. Circular dichroism and native gel electrophoresis analyses suggested that adding Na2EDTA causes a reverse structural transition from a parallel-stranded high-order structure to an antiparallel G-quadruplex. Moreover, atomic force microscopy showed a long nanowire ( approximately 200 nm) in the presence of Ni2+ but no significant image in the absence of Ni2+ or in the presence of both Ni2+ and Na2EDTA. These observations revealed that the parallel-stranded high-order structure is a G-wire containing numerous DNA oligonucleotide strands bound together via divalent metal ion-2,2'-bipyridine complexes. Finally, we found that alternating addition of Ni2+ and Na2EDTA can cycle the G-wire between the high-order and disorganized structures, with an average cycling efficiency of 0.95 (i.e., 5% loss per cycle). These results demonstrate that a DNA oligonucleotide incorporating the 2,2'-bipyridine unit acts as a G-wire switch that can be controlled by chemical input signals, namely, divalent metal ions.  相似文献   

14.
An electrolyte system, using malic acid as a complexing agent, has been developed to allow the determination of transition metal cations using miniaturised isotachophoresis. The method allowed the simultaneous determination of Mn2+, Cr3+, Fe2+, Co2+, Zn2+ and Ni2+ to be made without interference from other common ions. Limits of detection were calculated to be in the range 0.5-1.0mg l(-1) for Mn2+, Cr3+ Co2+ and Zn2+ and 2.0 mg l(-1) for Fe2+ and 4.7 mg l(-1) for Ni2+. The successful analysis of five industrial samples, containing a range of these metal ions, obtained from metal processing plants were achieved in under 13 min. The separations were performed on a poly(methyl methacrylate) chip with integrated platinum wire conductivity detection electrodes.  相似文献   

15.
The simultaneous determination of metal ions using ethylenediaminetetraacetic acid (EDTA) as a complexing agent and vancomycin as a complex selector was successfully studied by capillary electrophoresis with the U-shaped cell. The partial filling method (counter current mode) was used in order to gain selectivity of the separation, and also to increase the detection sensitivity. The effect of the vancomycin concentration on the separation behavior of free EDTA and metal products, and the effect of the EDTA concentration on the stability of metal-EDTA products were considered. Under the optimal condition, the reproducibilities (RSD) of the migration time and the peak area were less than 3.39% and 9.61%, respectively. With the high sensitivity of the method, Pb(II), Cu(II) and Fe(III) in tap water were successfully determined, and the recoveries were 99 - 105%. The concentrations of these metal ions found in tap water did not exceed the maximum allowed concentrations regulated by the U.S. Environmental Protection Agency.  相似文献   

16.
The membrane electrode based on a synthetic chalcocite (Cu(2)S) single crystal responds primarily to the activity of copper(I) ions in solution. The experimental selectivity coefficient with respect to copper(II) ions is in good agreement with the value calculated on the basis of solubility products of both sulphides. The electrode has been calibrated with metal-ion buffers containing a strongly complexing ligand. TETREN, and can be used as an indicator in titrations of copper with EDTA and TETREN. Comparison of an experimental titration curve with one calculated with the aid of the program HALTAFALL showed good agreement in the case of TETREN, but there were discrepancies for the EDTA titration, which are attributed to the presence and complexation of copper(I) ions. The electrode has also been applied in metal titrations with Cu(2+) as indicator ion, though the potential changes observed were smaller than predicted. All titrations showed errors less than 1%.  相似文献   

17.
THREEPROM  Jirasak  SOM-AUM  Waraporn  林金明 《中国化学》2006,24(12):1747-1753
A new separation system of capillary electrophoresis for the simultaneous determination of metals by using ethylenediamine tetraacetic acid (EDTA) as complexing agent and employing vancomycin as complex selector was described. The Z-shape cell capillary electrophoresis was used to enhance the sensitivity for the determination of the complexes of Cu(Ⅱ), Ni(Ⅱ), Co(Ⅱ) and Fe(Ⅲ) with EDTA. The partial filling method (co-current mode) was used in order to increase the selectivity of the electrophoretic method, meanwhile vancomycin was not present at the detector path during the detection of metal-EDTA complexes. The vancomycin concentration, phosphate concentration and pH of the buffer strongly influenced mobility, resolution and selectivity of the studied analytes. Under the optimal condition, the relative standard deviations (n=5) of the migration time and the peak area were less than 3.14% and 7.35%, respectively. Application of the Z-shape cell capillary electrophoresis method with UV detection and vancomycin loading led to the reliable determination of these metal ions in tap water and the recoveries were 97%-101%. The detection limits based on a signal to noise ratio of 3 : 1 were found in the range of 2-10 μg·L^-1.  相似文献   

18.
A new preconcentration method was developed for the determination of trace amounts of Cu(II), Fe(III), Pb(II), Ni(II), and Cd(II) on a double-walled carbon nanotube disk. 4-(2-Thiazolylazo) resorcinol was used as a complexing reagent. The effects of parameters, including pH of the solutions, amounts of complexing reagent, eluent type, sample volume, flow rates of solutions, and matrix ions were examined for quantitative recoveries of the studied analyte ions. The retained metal ions were eluted by 2 M HNO3. The LOD values for the analytes were in the range of 0.7-4.4 microg/mL. Natural water samples and standard reference materials were analyzed by the presented method.  相似文献   

19.
The diffusive gradients in thin films technique (DGT) was used for uranium measurements in water. DGT devices with Dowex resin binding phase (Dow DGT) were tested in synthetic river water, which gave 84% response to total uranium concentration. The devices were also deployed in natural river water and compared to devices with other types of binding phases, Chelex 100 resin beads imbedded in polyacrylamide hydrogel (Chelex DGT) and DE 81 anion exchange membrane (DE DGT), deployed in the same location at the same time. The measurement by Dow DGT was the lowest among the different types of the DGT devices, 45% of total uranium, while measurement by DE DGT was the highest, 98% of total uranium. The results achieved by the three types of DGT devices were explained by three DGT working mechanisms, equilibrium between complexes of resin/uranyl carbonates and complexes of resin/competitive ligands in water, effective reduction of uranyl carbonate concentration by the binding phase and dissociation of UO2(CO3)22− and UO2(CO3)34− within the diffusive layer in a DGT device. It is hoped that by deploying the DGT devices with different binding phases in natural waters, additional information on uranium speciation could be obtained.  相似文献   

20.
This work investigated the application of diffusive gradients in thin films technique (DGT) to uranium speciation measurements in natural water. Two binding phases were examined, a commercially available affinity membrane, Whatman DE 81 (DE 81), with amino binding functional groups and the conventionally used Chelex 100 beads imbedded polyacrylamide hydrogel (Chelex) with iminodiacetate functional groups. The DGT devices assembled with the binding phases of DE 81 (DE 81 DGT) and Chelex gel (Chelex DGT) were tested both in synthetic river water solutions and in local river water. DE 81 DGT and Chelex DGT measured 80% and 75% of the total uranium in synthetic river water solution, respectively, and measured 73% and 60% of the total uranium in St. Lawrence River, Canada, respectively. The binding properties of the DE 81 membrane and Chelex gel for uranium, and the diffusion of uranyl complexes in the polyacrylamide gel (PAM) were also studied.  相似文献   