首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
For the first time, an enzyme-linked immunosorbent assay (ELISA) has been developed and validated for the determination of fluvastatin (FLV) in plasma samples at picogram level. The assay employed a polyclonal antibody that specifically recognizes FLV with high affinity, and FLV conjugate of bovine serum albumin (FLV-BSA) immobilized onto microplate wells as a solid-phase. The assay involved a competitive binding reaction between FLV, in plasma sample, and the immobilized FLV-BSA for the binding sites on a limited amount of the anti-FLV antibody. The bound anti-FLV antibody was quantified with horseradish peroxidase-labeled second anti-rabbit IgG antibody (HRP-IgG) and 3,3′,5,5′-tetramethylbenzidine (TMB) as a substrate for the peroxidase enzyme. The concentration of FLV in the sample was quantified by its ability to inhibit the binding of the anti-FLV antibody to the immobilized FLV-BSA and subsequently the color intensity in the assay wells. The conditions for the proposed ELISA were investigated and the optimum conditions were employed in the determination of FLV in plasma samples. The assay limit of detection was 10 pg mL−1 and the effective working range at relative standard deviations (RSD) of ≤5% was 20-1000 pg mL−1. Analytical recovery of FLV from spiked plasma was 97.1-102.7 ± 2.85-6.25%. The precision of the assay was satisfactory; RSD was 2.46-5.37 and 3.19-6.64% for the intra- and inter-assay precision, respectively. The analytical procedure is convenient, and one can analyze ∼200 samples per working day, facilitating the processing of large-number batch of samples. The proposed ELISA has a great value in routine analysis of FLV for its therapeutic monitoring and pharmacokinetic studies.  相似文献   

2.
This study describes the development and validation of a highly sensitive and specific enzyme immunoassay (EIA) for therapeutic monitoring and pharmacokinetic studies of atorvastatin (ATR). The assay employs a polyclonal antibody that recognizes ATR with high specificity and affinity, and ATR conjugated to bovine serum albumin (ATR-BSA) immobilized onto microwell plates as a solid phase. The assay involved a competitive binding reaction between ATR and the immobilized ATR-BSA for the binding sites on a limiting amount of the anti-ATR antibody. The bound anti-ATR antibody was quantified with horseradish peroxidase-labeled anti-immunoglobulin secondary antibody and 3,3′,5,5′-tetramethylbenzidine as a substrate for the peroxidase enzyme. The concentration of ATR in the sample was quantified by its ability to inhibit the binding of the anti-ATR antibody to the immobilized ATR-BSA and subsequent color development in the assay wells. The conditions for the EIA were investigated and optimized for the determination of ATR in plasma samples. The limit of detection was 0.04 ng mL?1 and the effective working range at relative standard deviations (RSD) of ≤5% was 0.1–10 ng mL?1. Mean analytical recovery of ATR from spiked plasma was 99.3?±?2.8%. The precision of the assay was satisfactory; RSD were 2.7–4.6 and 3.3–5.7% for intra- and inter-assay precision, respectively. The reliability of the EIA was confirmed by HPLC. The EIA is convenient, and one can analyze ~ 200 samples per working day, facilitating the processing of large-number of samples of ATR.  相似文献   

3.
The increasing global adoption of genetically modified (GM) plant derivatives in animal feed has provoked a strong demand for an appropriate detection method to evaluate the existence of transgenic protein in animal tissues and animal by-products derived from GM plant fed animals. A highly specific and sensitive sandwich enzyme immunoassay for the surveillance of transgenic Cry1Ab protein from Bt-maize in the blood plasma of cows fed on Bt-maize was developed and validated according to the criteria of EU-Decision 2002/657/EC. The sandwich assay is based on immuno-affinity purified polyclonal antibody raised against Cry1Ab protein in rabbits. Native and biotinylated forms of this antibody served as capture antibody and detection antibody for the ELISA, respectively. Streptavidin-horseradish peroxidase conjugate and TMB substrate provided the means for enzymatic colour development.The immunoassay allowed Cry1Ab protein determination in bovine blood plasma in an analytical range of 0.4-100 ng mL−1 with a decision limit (CCα) of 1.5 ng mL−1 and detection capability (CCβ) of 2.3 ng mL−1. Recoveries ranged from 89 to 106% (mean value of 98%) in spiked plasma.In total, 20 plasma samples from cows (n = 7) fed non-transgenic maize and 24 samples from cows (n = 8) fed transgenic maize (collected before and, after 1 and 2 months of feeding) were investigated for the presence of the Cry1Ab protein. There was no difference amongst both groups (all the samples were below 1.5 ng mL−1; CCα). No plasma sample was positive for the presence of the Cry1Ab protein at CCα and CCβ of the assay.  相似文献   

4.
For the detection of the major active component of cannabis, Δ9-tetrahydrocannabinol (THC) in aqueous samples, a homogeneous competitive immunoassay based on fluorescence quenching induced by fluorescence resonance energy transfer (FRET) has been developed. The fluorescence of anti-THC-antibody, labeled with fluorescence dye DY-481XL, can be quenched after its binding to THC-BSA-quencher conjugate (bovine serum albumin coupled with THC and another fluorescence dye, DYQ-661, as quencher). This quenching effect is inhibited when the antibodies bind to free THC in aqueous sample, thus competing for binding sites with the THC-BSA-quencher conjugate. The extent of the inhibition corresponds to the concentration of THC in the samples. The assay principle is simple and the test duration is within 10 min. The detection limit for THC in buffer was 2 ng mL−1. In pooled saliva samples a detection limit of 50 ng mL−1 was achieved.  相似文献   

5.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

6.
A highly sensitive competitive enzyme immunoassay (EIA) has been developed and validated for the determination of the plasma level of 2′-deoxycytidine (dCyd), the potential prognostic marker for breast cancer chemotherapy. This assay employed a monoclonal antibody that recognizes dCyd with a high specificity, and 5′-succinyl-dCyd (5′sdCyd) conjugate of bovine serum albumin (5′sdCyd-BSA) immobilized onto microplate wells as a solid phase. The assay involved a competitive binding reaction between dCyd, in plasma sample, and the immobilized 5′sdCyd-BSA for the binding sites of the anti-dCyd antibody. The bound antibody was quantified with horseradish peroxidase-labeled anti-immunoglobulin second antibody and 3,3′,5,5′-tetramethylbenzidine as a peroxidase substrate. The concentration of dCyd in the sample was quantified by its ability to inhibit the binding of the antibody to the immobilized 5′sdCyd-BSA and subsequently the color formation in the assay. The assay limit of detection was 8 nM and the effective working range at relative standard deviations (R.S.D.s) of ≤10% was 20-800 nM. No cross-reactivity from the structurally related nucleobases, nucleosides, and nucleotides was observed in the proposed assay. Mean analytical recovery of added dCyd was 98-100 ± 3.2-8.2%. The precision of the assay was satisfactory; R.S.D. was 3.4-4.2 and 4.3-8.9% for intra- and inter-assay precision, respectively. The proposed EIA was compared favorably with HPLC method in its ability to accurately measure dCyd spiked into plasma samples. The analytical procedure is convenient, and one can analyze 200 samples per working day, facilitating the processing of large-number batch of samples. The proposed EIA is expected to contribute in further evaluation of dCyd as a prognostic marker for breast cancer chemotherapy and elucidation of the role of dCyd in various biological and biochemical systems.  相似文献   

7.
It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional strip assay for small molecule, the NSI-strip assay was also based on the competitive theory, difference was that the analyte competed three times with the capture reagent for the limited number of antibody binding sites. After the assay, the number of TLs developed in the test zone was inversely proportional to the analyte concentration, thus analyte content levels could be determined by observing the appeared number of TLs. Taking aflatoxin B1 as the model analyte, visual detection limit of the NSI-strip was 0.06 ng mL−1 and threshold concentrations for TL-I–III were 0.125, 0.5, and 2.0 ng mL−1, respectively. Therefore, according to the appeared number of TLs, the following concentration ranges would be detectable by visual examination: 0–0.06 ng mL−1 (negative samples), and 0.06–0.125 ng mL−1, 0.125–0.5 ng mL−1, 0.5–2.0 ng mL−1 and >2.0 ng mL−1 (positive samples). That was to say, compared to traditional strips the NSI-strip could offer more parameter information of the target analyte content. In this way, the NSI-strip improved the qualitative presence/absence detection of traditional strips by measuring the content (range) of target analytes semiquantitatively.  相似文献   

8.
Fong BM  Tam S  Tsui SH  Leung KS 《Talanta》2011,83(3):1030-1036
A sensitive analytical method for the determination of tetrodotoxin (TTX) in urine and plasma matrices was developed using double solid phase extraction (C18 and hydrophilic interaction liquid chromatography) and subsequent analysis by HPLC coupled with tandem mass spectrometry. The double SPE sample cleanup efficiently reduced matrix and ion suppression effects. Together with the use of ion pair reagent in the mobile phase, isocratic elution became possible which enabled a shorter analysis time of 5.5 min per sample. The assay results were linear up to 500 ng mL−1 for urine and 20 ng mL−1 for plasma. The limit of detection and limit of quantification were 0.13 ng mL−1 and 2.5 ng mL−1, respectively, for both biological matrices. Recoveries were in the range of 75-81%. To eliminate the effect of dehydration and variations in urinary output, urinary creatinine-adjustment was made. TTX was quantified in eight urine samples and seven plasma samples from eight patients suspected of having TTX poisoning. TTX was detected in all urine samples, with concentrations ranging from 17.6 to 460.5 ng mL−1, but was not detected in any of the plasma samples. The creatinine-adjusted TTX concentration in urine (ranging from 7.4 to 41.1 ng μmol−1 creatinine) correlated well with the degree of poisoning as observed from clinical symptoms.  相似文献   

9.
A pretreatment-free immunochromatographic assay for detection of chloramphenicol (CAP) in milk was developed. The assay is based on competition between CAP molecules in the sample and immobilized CAP-protein conjugate for binding to monoclonal anti-CAP antibodies conjugated with colloidal gold particles (average diameter 30 nm). The assay is carried out in the course of sample flowing along test strip with immobilized reactants, and its results can be detected by the naked eye or by a photometric device. Effect of the concentration of immunoreactants on assay characteristics was studied. The assay protocol with maximal sensitivity and reliability was optimized using measured values of brightness of lines. Detection limit for CAP is 10 ng mL−1. Assay duration is 10 min, and it can be carried out at room temperature without any additional devices and reactants. The developed test strip has been applied to CAP detection in dairy products.  相似文献   

10.
A one-step immunochromatographic assay (ICA) was developed for the detection of seven kinds of cephems in milk. Polyclonal antibodies (PcAb) with group-specific to cephems were raised in rabbits after immunization with cephalexin-keyhole limpet hemocyanin (KLH) conjugate. The specificity of anti-sera was determined by indirect competitive enzyme-linked immunosorbent assay (icELISA), and the 50% inhibitions (IC50) of cephalexin and cefadroxil were obtained at 1.5 ng mL−1; IC50 of cefatiofur, cefapirin, cefazolin, cefalothin and cefotaxine were 4, 3.7, 3.2, 4.5 and 5 ng mL−1, respectively. The PcAb against cephems were conjugated to colloidal gold particles as the detection reagent for ICA strips to test for cephems. This method achieved semi-quantitative detection of cephems in <5 min, with high sensitivity to cephalexin and cefadroxil (both 0.5 ng mL−1). At the same time, cefatiofur, cefapirin, cefazolin, cefalothin and cefotaxine were detected at <100 ng mL−1 in spiked processed-milk samples. This method was compared with an enzyme-linked immunosorbent assay by testing 40 milk samples, and the positive samples were validated by a high-performance liquid chromatographic method, with an agreement rate of 100% for both comparisons. In conclusion, the method was rapid and accurate for the multi-residue detection of cephems in milk.  相似文献   

11.
A novel immunoassay format employing direct coating of small molecular hapten on microtiter plates is reported for the detection of atrazine and 2,4-dichlorophenoxyacetic (2,4-D). In this assay, the polystyrene surface of microtiter plates was first treated with an acid to generate -NO2 groups on the surface. Acid treated plates were further treated with 3-aminoprpyltriethoxysilane (APTES) to functionalize the plate surface with amino groups for covalent linkage to small molecular hapten with carboxyl groups. The modified plates showed significantly high antibody binding in comparison to plates coated with hapten-carrier protein conjugates and presented excellent stability as a function of the buffer pH and reaction time. The developed assay employing direct hapten coated plates and using affinity purified atrazine and 2,4-D antibodies demonstrated very high sensitivity, IC50 values for atrazine and 2,4-D equal to 0.8 ng mL−1 and 7 ng mL−1, respectively. The assay could detect atrazine and 2,4-D levels in standard water samples even at a very low concentration upto 0.02 and 0.7 ng mL−1 respectively in the optimum working range between 0.01 and 1000 ng mL−1 with good signal reproducibility (p values: 0.091 and 0.224 for atrazine and 2,4-D, respectively). The developed immunoassay format could be used as convenient quantitative tool for the sensitive screening of pesticides in samples.  相似文献   

12.
Generic simple and sensitive universal enzyme immunoassay approach for the determination of small analytes has been developed to avert the problems associated with small molecule immobilization onto solid phases. The developed assay employed a heterogeneous non-competitive binding format. The assay used anti-analyte antibody coupled to polyacrylamide beads as a solid-phase and β-d-galactosidase enzyme-labeled analyte as a label. In this assay, the analyte in a sample was firstly incubated to react with an excess of the antibody-coupled beads, and then the unoccupied antibody binding sites were allowed to react with the enzyme-labeled analyte. Analyte bound to the antibody-coupled beads was separated by centrifugation, and the enzyme activity of the supernatant was measured spectrophotometrically at 420 nm, after reaction with 4-nitrophenyl-β-d-galactopyranoside as a substrate for the enzyme. The signal was directly proportional to the concentration of analyte in the sample. The optimum conditions for the developed assay were established and applied to the determination of tobramycin, as a representative example of the small analytes, in serum samples. The assay limit of detection was 10 ng mL−1 and the effective working range at relative standard deviation of ≤10% was 40-800 ng mL−1. The assay precisions were acceptable; the relative standard deviations were 4.36-5.17 and 5.62-7.40% for intra- and inter-assay precision, respectively. Analytical recovery of tobramycin spiked in serum ranged from 95.89 ± 4.25 to 103.45 ± 4.60%. The assay results correlated well with those obtained by high-performance liquid chromatography (r = 0.992). The assay described herein has great practical value in determination of small analytes because it is sensitive, rapid, and easy to perform in any laboratory. Although the assay was validated for tobramycin, however, it is also anticipated that the same methodology could be used for essentially any analyte for which a selective antibody exists, and an appropriate enzyme conjugate can be made.  相似文献   

13.
An immunoaffinity (IA) sorbent with antibody fragments was prepared for the analysis of opioid peptides by on-line immunoaffinity solid-phase extraction capillary electrophoresis–mass spectrometry (IA-SPE-CE–MS). The antibody fragmentation was evaluated by MALDI-TOF-MS. Fab′ fragments obtained from a polyclonal IgG antibody against Endomorphins 1 and 2 (End1 and End2) were covalently attached to succinimidyl silica particles to prepare the IA sorbent. An IA-SPE-CE–MS methodology was established analyzing standard solutions of End1 and End2 and acceptable repeatability, linearity ranges and LODs (0.5 and 5 ng mL−1, respectively) were obtained. The LOD of End1 was slightly better than that previously obtained using an IA sorbent with intact antibodies (1 ng mL−1). In human plasma samples, End1 and End2 could be detected at 1 and 50 ng mL−1, respectively, which meant an improvement of 100 and 2-fold with regard to the LODs using an IA sorbent with intact antibodies (100 ng mL−1).  相似文献   

14.
Yanyan Lu  Zhi Xing  Po Cao  Xinrong Zhang 《Talanta》2009,78(3):869-1801
A sandwich-type immunoassay linked with inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the detection of anti-erythropoietin antibodies (anti-EPO Abs). Recombinant human erythropoietin (rhEPO) was immobilized on the solid phase to capture anti-rhEPO Abs specifically. After the immunoreactions with Au-labeled goat-anti-rabbit IgG, a diluted HNO3 (2%) was used to dissociate Au nanoparticles which was then introduced to the ICP-MS for measurements. Under the optimized conditions, the calibration graph for anti-EPO Abs was linear in the range of 35.6-500 ng mL−1 with a detection limit of 10.7 ng mL−1 (3σ, n = 9). The relative standard deviation (R.S.D.) for three replicate measurements of 30.9 ng mL−1 of anti-EPO Abs was 8.43%. The recoveries of anti-EPO Abs in sera at the spiking level of 50, 100, 150, 200 and 400 ng mL−1 were 99.2%, 101.5%, 95.0%, 94.0% and 102.9%, respectively. For the real sample analysis, 26 samples from healthy people and 53 samples from patients with rhEPO treatments were studied. One sample from patients showed significantly higher anti-EPO Abs from other samples, indicating a possibility of immune response of this patient.  相似文献   

15.
Y?ld?z Uluda? 《Talanta》2010,82(1):277-383
A simple and sensitive sensor method for cancer biomarkers [prostate specific antigen (PSA) and PSA-alpha 1-antichymotrypsin (ACT) complex] analysis was developed, to be applied directly with human serum (75%) by using antibody modified quartz crystal microbalance sensor and nanoparticles amplification system. A QCM sensor chip consisting of two sensing array enabling the measurement of an active and control binding events simultaneously on the sensor surface was used in this work. The performance of the assay and the sensor was first optimised and characterised in pure buffer conditions before applying to serum samples. Extensive interference to the QCM signal was observed upon the analysis of serum. Different buffer systems were then formulated and tested for the reduction of the non-specific binding of sera proteins on the sensor surface. A PBS buffer containing 200 μg mL−1 BSA, 0.5 M NaCl, 500 μg mL−1 dextran and 0.5% Tween 20, was then selected which eliminated the interfering signal by 98% and enabled the biomarker detection assay to be performed in 75% human serum. By using Au nanoparticles to enhance the QCM sensor signal, a limit of detection of 0.29 ng mL−1 PSA and PSA-ACT complex (in 75% serum) with a linear dynamic detection range up to 150 ng mL−1 was obtained. With the achieved detection limit in serum samples, the developed QCM assay shows a promising technology for cancer biomarker analysis in patient samples.  相似文献   

16.
Electro membrane extraction (EME) as a new microextraction method was applied for extraction of sodium diclofenac (SDF) as an acidic compound from wastewater, urine, bovine milk and plasma samples. Under applied potential of 20 V during the extraction, SDF migrated from a 2.1 mL of sample solution (1 mM NaOH), through a supported liquid membrane (SLM), into a 30 μL acceptor solution (10 mM NaOH), exist inside the lumen of the hollow fiber. The negative electrode was placed in the donor solution, and the positive electrode was placed in the acceptor solution. 1-octanol was immobilized in the pores of a porous hollow fiber of polypropylene as SLM. Then the extract was analyzed by means of high-performance liquid chromatography (HPLC) with UV-detection for quantification of SDF. Best results were obtained using a phosphate running electrolyte (10 mM, pH 2.5). The ranges of quantitation for different samples were 8–500 ng mL−1. Intra- and inter-day RSDs were less than 14.5%. Under the optimized conditions, the preconcentration factors were between 31 and 66 and also the limit of detections (LODs) ranged from 2.7 ng mL−1 to 5 ng mL−1 in different samples. This procedure was applied to determine SDF in wastewater, bovine milk, urine and plasma samples (spiked and real samples). Extraction recoveries for different samples were between 44–95% after 5 min of extraction.  相似文献   

17.
A liposome immune lysis assay for enrofloxacin in carp and chicken muscle   总被引:1,自引:0,他引:1  
A homogenous complement-mediated liposome immune lysis assay (LILA) was developed for the determination of enrofloxacin (ENRO) in carp and chicken muscle. ENRO was covalently coupled to DPPE, and then immobilized onto the surface of liposomes by reverse-phase evaporation method. The performed liposome would be specifically lysed by the sequential additions of anti-ENRO monoclonal antibody (MAb) and guinea pig complement. Through a competitive assay format, the performed liposome can be used to detect ENRO in a range of 5.0-20 ng mL−1 in assay buffer. The limit of detection of ENRO in carp and chicken muscle was 1 ng g−1 and the limit of quantification was 2 ng g−1. Recoveries ranged from 58.3% to 65.2% for carp and 55.6-63.8% for chicken muscle at spiked levels of 2-8 ng g−1, with intra-assay and inter-assay variations 5.6-12.3% and 7.1-19.2%, respectively.  相似文献   

18.
Two novel enzyme immunoassays of fentanyl have been developed using Horseradish Peroxidase (HRP) as an enzyme, 3,3′,5,5′tetramethylbenzidine (TMB) and luminol as its colorimetric and its chemiluminescence substrate, respectively. A fentanyl polyclonal antibody was used as a capture antibody for fentanyl and fentanyl-bovine serum albumin (BSA) conjugate. The latter was first biotinylated and then bound by streptavidin labeled with HRP, resulting in the development of two novel competitive immunoassays. The detection limits were 0.045 and 0.0048 ng ml−1 for spectrophotometric and chemiluminescence detection, respectively, and were much lower than existing HRP-fentanyl based kits. Intra- and inter-assay CVs were 2.6-4.5 and 5.4-11.2%, respectively, at concentrations of 0.050-5.000 ng ml−1 for the colorimetric assay, whilst for the chemiluminescent assay intra- and inter-assay CVs were 3.7-6.2 and 6.2-12.3%, respectively, for the linear range of the assay at concentrations of 0.008-0.800 ng ml−1. The methods in this study were developed in order to measure maternal and neonatal fentanyl plasma samples during cesarean section, after the application of a novel subarachnoid analgesia technique. The 28 maternal and neonatal plasma samples were measured by both assays, providing data for subarachnoid administration of fentanyl that had never been presented before.  相似文献   

19.
This study aimed at developing competitive enzyme-linked immunosorbent assays (ELISAs) for the organophosphorus (OP) insecticide fenitrothion using a monoclonal antibody. The hapten used to obtain the antibody had an ideal structural feature that allowed minimal functional group sacrifice. By using the antibody and a coating antigen, a competitive indirect ELISA was developed, which showed an IC50 of 14 ng mL−1 with a detection limit of 3.0 ng mL−1. A competitive direct ELISA using an enzyme tracer was also developed, which showed an IC50 of 17 ng mL−1 with a detection limit of 1.6 ng mL−1. The antibodies in both assays showed negligible cross-reactivity with the metabolites of fenitrothion and other OP pesticides except with the insecticides parathion-methyl and parathion-ethyl. Recoveries of fenitrothion from fortified rice and lettuce samples were determined and the bias in the recovery values was rationalized by using the standard curves obtained in the matrix extract.  相似文献   

20.
The use of Sudan I as an additive in food products has been prohibited in the European Union and many other countries. In this study, a highly sensitive and specific monoclonal antibody (mAb)-based indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of Sudan I in food samples was developed. The hapten derivative with a three-carbon-atom length of carboxylic spacer at the azobound para-position was synthesized and coupled to carrier proteins. The hapten-bovine serum albumin (BSA) conjugate was used as an immunogen, while the hapten-ovalbumin (OVA) conjugate was applied as a coating antigen. The mAb against Sudan I was produced by hybridoma technique and the corresponding ELISA was characterized in terms of sensitivity, specificity, precision and accuracy. At optimal experimental conditions, the standard curve was constructed in concentrations of 0.1-100 ng mL−1. The values of IC50 for nine standard curves were in the range of 1.1-2.0 ng mL−1 and the LOD at a signal-to-noise ratio of 3 (S/N = 3) was 0.07-0.14 ng mL−1. The cross-reactivity values of the mAb with Sudan II, III and IV were 9.5%, 33.9% and 0.95%; no cross-reactivity was found with other six edible colorants: Lemon yellow, Bright blue, Indigotin, Kermes, Amarant and Sunset yellow, indicating the assay displays not only high sensitivity but also high specificity as well. The organic solvent effect on the assay was tested. It was observed that the ELISA was tolerated to 30% of methanol and 10% of acetonitrile without significant loss of IC50 value. Six food samples were spiked with Sudan I and the methanolic extracts after appropriate dilution were analyzed by ELISA. Acceptable recovery rates of 88.2-110.5% and coefficients of variation of 2.5-17.4% were obtained. The ELISA for nine spiked samples was confirmed by high-performance liquid chromatography (HPLC) with a high correlation coefficient of 0.9840 (n = 9). The mAb-based ELISA proven to be a feasible quantitative/screening method for Sudan I analysis in food samples with the properties of high sensitivity, specificity, simplicity of sample pretreatment, high sample throughput and low expense.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号